• 제목/요약/키워드: Heater System

검색결과 656건 처리시간 0.029초

카본 발열체의 온도 및 전기적 특성에 관한 연구 (A Study on the Temperature and Electrical Characteristics of Carbon Heater)

  • 김진화;심규진;공태우;정효민;정한식
    • 동력기계공학회지
    • /
    • 제10권1호
    • /
    • pp.71-76
    • /
    • 2006
  • This paper aims to study several type heaters which are mica heater, film heater, quartz heater and rod heater and to get an temteraturel and electrical characteristics. These four type heaters have a merit in many fields than present electric heater with nichrome wire. Carbon and mica plate heater have higher heat efficiency and less electromagnetic waves. Also it has been reported that far infrared ray emission from this heater is good for our health. Additionally heating element is thin and lighter plate. For these reasons, they will be widely used to various application such as room-heating or manufacturing goods. Experimental result confirmed that when 220V current authorized, the temperature, electric current, electric power and the resistance rise to stationary state in early stage. Moreover, the temperatures and electric characteristics show a good stability.

  • PDF

연료전지 자동차용 TMS 히터 개발 (Development of Thermal Management System Heater for Fuel Cell Vehicles)

  • 한수동;김성균;김치명;박용선;안병기
    • 한국수소및신에너지학회논문집
    • /
    • 제23권5호
    • /
    • pp.484-492
    • /
    • 2012
  • The TMS(Thermal Management System) heater in a fuel cell vehicle has been developed to prevent a decline of fuel cell durability and cold start durability. Main functions of the COD(Cathode Oxygen Depletion) heater are depletion of oxygen in a cathode as heat energy and consumption of electric power for rapid warming up of a fuel cell stack. This paper covers subjects including the design specification of a heater, heater controller for detection of overheat and reliability assessment including coolant pressure cycle test of a heater. To verify the design concept, burst pressure and deformation analysis of plastic housing were carried out. Also, temperature distribution analysis of heater surface and coolant inside of housing were carried out to verify the design concept. By designing the plastic housing instead of a steel housing, the 30% weight lightening and 50% cost reduction were attained. A module-based design of a TMS system including a heater or reducing the watt density of a heater is a problem to be solved in the near future work.

원적외선 면상발열체에 의한 온실 난방시스템의 열특성 분석 (Thermal Energy Characteristics for Greenhouse Heating System with Far-Infrared Heater)

  • 노정근;김희준;리혁;한충수;조성찬
    • Journal of Biosystems Engineering
    • /
    • 제31권6호
    • /
    • pp.529-534
    • /
    • 2006
  • The greenhouse heating system with far-infrared heater was built to analyze various thermal characteristics, such as greenhouse air temperature, soil temperature, energy flow, energy consumption in far-infrared heater, and other factors, which could be used in comparison with other greenhouse heating system in this study. The results showed that the inside air temperature of the far-infrared greenhouse heating system was $5^{\circ}C$ higher than that of hot air heating system. Heat loss of daytime was found to be larger than that of night time as much as 44.8% for the heating system with far-infrared heater. In the heating system with far-Infrared heater, when the lowest ambient temperature was -8 $\sim$ -7$^{\circ}C$, the air temperature of greenhouse was 12 $\sim$ 15$^{\circ}C$, thus the far-infrared heating system was shown to be feasible for heating system. Energy consumption of far-infrared heating system was shown to be less than that of hot air heating system.

고온초전도자석 충전용 히터트리거 스위칭 시스템에 관한 연구 (A Study on the Heater-Triggered Switching System for Charging of a HTS Magnet)

  • 배덕권;안민철;최석진;김영식;김호민;이찬주;윤용수;이상진;신철기
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.76-79
    • /
    • 2001
  • The heater-triggered switching system for charging of a high temperature superconductor(HTS) is prepared by simulation and investigated its characteristic by experiment. heater-triggered switching system consists of two nickel-chrome alloy heater, an electromagnet and YBCO bulk HTS. There are three important parameters to generate the pumping-current in this system. The timing sequential control of two heters and electromagnet is an important factor to generate pumping-current in the YBCO bulk HTS. Thermal analysis of the switching part in YBCO bulk HTS according to the heater input current was carried out. Electromagnet of 0.6[T] and DC heater input current of 2.3[A] were optimally derived. In this experiment, the maximum pumping current is reaches about 12[A].

  • PDF

적외선 패널히터의 온도분포 측정 (Measurement of Temperature Distribution in the Infrared Panel Heater)

  • 이공훈;하수석;김욱중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1178-1183
    • /
    • 2004
  • Temperature distribution and heating characteristic of the panel heater for infrared heating have been investigated. The temperature variation with time is firstly measured with the thermocouple to figure out the response time of the heater to the power input. The heater reaches faster to the steady state in comparison to the ceramic heater. The infrared thermal imaging system is utilized to investigate the temperature distribution over the heater surface. The measured thermal images show that the thermal boundary layer induced by the free convection near the heater surface affects the temperature distribution on the surface. The images also show the fairly good uniformity of the temperature distribution in the core region of the surface.

  • PDF

Bi-2223 팬케익부하 충전용 히터-트리거 스위칭 장치의 설계 및 제작 (Design and Fabrication of Heater-triggered Switching System for the Charging of Bi-2223 Pancake Load)

  • 김영식;윤용수;배덕권;안민철;임대준;김호민;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.43-48
    • /
    • 2004
  • This paper deals with design and fabrication of heater-triggered switching system for the high-Tc superconducting (HTS) power supply with series-connected double-pancake load. Amongst all components, heater triggering is the most important element for the performance of HTS power supply. To fabricate the optimal heater-triggered system, its characteristics have been analysed through the simulation and expriment. The thermal analysis of switching parts of the Bi-2223 solenoid according to the heater input was carried out. Based upon the analysis, 8A electromagnet current and 1.5A DC Heater current were optimally derived, and 8s and 20s for the pumping period were selected in this experiment. In the experiment. the maximum pumping current reached about 24A with Bi-2223 pancake load of 6mH.

실증연구를 위한 주택용 태양열 온수기 모니터링 시스템 개발 (The Development of monitoring system for demonstration research of solar hot water heater for dwellings)

  • 양동조;김재열;한재호;송경석;김우진
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.156-161
    • /
    • 2004
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF

재열기를 사용한 고성능 VI 사이클 열펌프의 난방 성능 특성에 관한 연구 (A Study on the Characteristics of Heating Performance of High-Performance Heat Pump with VI cycle using Re-Heater)

  • 이진국;최광환
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.69-75
    • /
    • 2015
  • In this study, the characteristics of heating performance of a high-performance air-cooled heat pump with vapor-injection(VI) cycle using re-heater was investigated experimentally. Devices used in the experiment is consist of a VI compressor, condenser, oil separator, refrigerant (economizer outlet refrigerant) re-heater, economizer, evaporator. And R410A was used as a working fluid. The experiment was conducted with two cycles(cycles A and B) for investigating heating performance. In case of cycle B, heat exchange was conducted by re-heater between outlet refrigerant of compressor and suction refrigerant of the VI system(Fig.1, re-heater). But the re-heater was not used in case of cycle A. As a result of this experiment, discharge temperature of refrigerator in compressor was shown higher value, when the cycle B was conducted, because of the heat exchange between suction refrigerant of VI cycle and outlet refrigerant of compressor in the re-heater than cycle A that was not use re-heater. it means that liquid hammer and the decrement of heating performance can be decreased by using re-heater. Also, Heating coefficient of performance(COPh) was shown about 2.98 in Cycle B which was 4% higher than Cycle A and from these results, It was confirmed that the improvement of the heating performance of heat pump with VI cycle can be achieved by applying re-heater.

다파장 IR-heater를 이용한 재작업 장치 설계 (Design of Rework Device using Multi-wave IR-heater)

  • 조도현
    • 전자공학회논문지 IE
    • /
    • 제47권1호
    • /
    • pp.6-11
    • /
    • 2010
  • 본 논문은 다파장 IR-heater를 이용하여 전자부품을 솔더령 하거나 또는 회로기판으로부터 분리를 하는 전자회로기판 수리장치에 관한 설계를 다룬다. 이 IR 수리 장치는 IR-heater를 이용하여 납땜의 용융온도 설정에 따라 안정한 온도 제어 아래 목표 영역의 온도를 중가시킨다. 이렇게 설계된 시스템은 PCB와 실장된 소자에 어떠한 열 손상을 주지 않는다. 그 성능융 실험을 통해 평가한다.

램제트 엔진의 지상시험용 Vitiated Air Heater의 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of the Vitiated Air Heater in the Ramjet Engine Ground-Testing)

  • 윤현진;손창현;이충원
    • 한국추진공학회지
    • /
    • 제3권4호
    • /
    • pp.51-57
    • /
    • 1999
  • Ramjet 엔진에서 Ramjet 입구의 초음속 유동에 의한 압축과정은 연소기내로 유입되는 공기의 온도를 상승시킨다. 따라서 고도와 비행조건에 따라 변하는 실제비행조건을 모사하기 위해서는 공기의 온도와 속도를 정확하게 제어할 필요가 있다. 본 연구에서는 Vitiated Air Heater를 제작하여 공기, 수소, 산소의 안을 변화시키면서 Vitiated Air Heater 연소가스(Vitiated Air)의 온도분포와 속도분포, 그리고 연소가스 성분을 측정함으로써 Vitiated Air Heater의 성능을 평가하였다. 그 결과 Ramjet 엔진의 지상실험범위에 요구되는 Ramjet 연소기 입구의 유입 속도범위(80~120 ㎧)와 온도범위(400~800 K)를 만족하였으며, 균일한 속도 및 온도분포로 대기공기와 같은 산소성분비를 가지는 Vitiated hir를 얻을 수 있었다.

  • PDF