• Title/Summary/Keyword: Heater Power

Search Result 473, Processing Time 0.027 seconds

Fabrication and Gas Sensing Characteristics of $MoO_3$ Thin Film Sensor ($MoO_3$ 박막센서 제조 및 가스감지특성)

  • Hwang, Jong-Taek;Jang, Gun-Eik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.826-829
    • /
    • 2002
  • $MoO_3$ thin films were deposited on electrode and heater screen-printed alumina substrates in en atmosphere by RF reactive sputtering. The deposition was performed at $300^{\circ}C$ with 350W of a forward power in an $Ar-O_2$ atmosphere. The working pressure was maintained at $3{\times}10^{-2}$mtorr and all deposited films were annealed at $500^{\circ}C$ for 5hours. The surface morphology of films was observed by using a SEM and crystalline phases were analyzed by XRD. The sensing properties were investigated in term of gas concentration under exposure of reducing gases such as $H_2$, $NH_3$ and CO.

  • PDF

COMPUTATIONAL ANALYSIS OF AN ELECTRO-THERMAL ICE PROTECTION SYSTEM IN ATMOSPHERIC ICING CONDITIONS (대기 결빙 조건에서의 전기열 방식 결빙보호 시스템에 관한 전산해석)

  • Raj, L.P.;Myong, R.S.
    • Journal of computational fluids engineering
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • Atmospheric icing may have significant effects not only on safety of aircraft in air, but also on performance of wind turbine and power networks on ground. Thus, ice protection measure should be developed to protect these systems from icing hazards. A very efficient method is the electro-thermal de-icing based on a process by which ice accretion is melted and blown away through aerodynamic forces. In this computational study, a state-of-the-art icing code, FENSAP-ICE, was used for the analysis of electro thermal de-icing system. Computational results including detailed conjugate heat transfer analysis were then validated with experimental data. Further, the computational model was applied to the DU21 airfoil section of NREL 5MW wind turbine with calculated heater parameters.

Variable Orifice De-super Heater for LNG Carrier or Power Plant (LNG선용 / 발전설비용 가변 오리피스형 과열도)

  • Choi, Du-Yeal;Lee, Joung-Soo;Choi, Hyun-Kue;Choi, Soon-Ho
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.210-211
    • /
    • 2005
  • Desuperheater is a passive device to control the temperature of steam in various plants. However, in spite of its simple structure, the accurate prediction of a desuperheater is very difficult because there are many designed factors for the design of a desuperheater. In this study, the theory of heat transfer phenomena in a desuperheater was developed and the various design factors are evaluated. As a results, we confirmed that the droplet size of 30 - 200 is best effective for the performance of a desuperheater.

  • PDF

Building Energy Management System Coupling with Renewable Energy System

  • Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.34 no.9
    • /
    • pp.705-709
    • /
    • 2010
  • Buildings nowadays are increasingly expected to need higher and more economic performance requirements. Energy consumption in buildings accounts for over 30% of total energy use. The Building Energy Management System (BEMS) and renewable energy (RE) technologies are considered as a potential measure to improve energy efficiency and reduce use of grid-power. It is, however, a challenge to utilise the intermittent energy supply of RE in building energy systems. This paper presents an experimental study on a RE-embedded BEMS. A control algorithm for the RE-embedded BEMS was designed to maximise the utilisation of RE and eventually to reduce electrical utility bill. The proposed system is tested at a laboratorial chamber with an air conditioner, fan and heater. The contribution of RE in building energy system is discussed to this end.

A Study for the Performance Improvement by Fumigation LPG on Diesel Engine using a Used Frying Oil (폐식용유를 사용한 디젤기관에서의 LPG 공급에 의한 성능개선에 관한 연구)

  • 조기현;황의현;백태실;정형길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.16-24
    • /
    • 2000
  • In this study, using frying oil, performance of engine and emission concentration were compared with the case of using diesel oil. And results are as follows. 1. Engine torque and brake horse power indicate nearly same value as the case of using diesel fuel. 2. Temperature of exhaust gas was increased with as high engine speed and load. 3. To reduce concentration of hydrocarbon, it is effective to operate using used frying oil in low engine speed and load, and adding LPG in high engine speed and load. 4. Concerning with concentration of carbon mono oxide and smoke emission, it was assured, that as engine load increased, lower concentration emitted in case of utilizing mixed fuel than that of utilizing pure diesel fuel.

  • PDF

Minimization of Energy Consumption for Amine Based CO2 Capture Process by Process Modification

  • Sultan, Haider;Bhatti, Umair H.;Cho, Jin Soo;Park, Sung Youl;Baek, Il Hyun;Nam, Sungchan
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.13-18
    • /
    • 2019
  • The high energy penalty in amine-based post-combustion CO2 capture process is hampering its industrial scale application. An advanced process is designed by intensive heat integration within the conventional process to reduce the stripper duty. The study presents the technical feasibility for stripper duty reduction by intensive heat integration in CO2 capture process. A rigorous rate-based model has been used in Aspen Plus® to simulate conventional and advanced process for a 300 MW coal-based power plant. Several design and operational parameters like split ratio, stripper inter-heater location and flowrate were studied to find the optimum values. The results show that advanced configuration with heat integration can reduces the stripper heat by 14%.

Control of ITO/PET Thin Films Depending on the Ratio of Oxygen Partial Pressure in Sputter (스퍼터의 산소분압비율에 의존한 ITO/PET박막의 조절)

  • 김현후;신재혁;신성호;박광자
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.6
    • /
    • pp.671-676
    • /
    • 1999
  • ITO (indium tin oxide) thin films on PET (polyethylene terephthalate) substrate have been deposited by a dc reactive magnetron sputtering without heat treatments such as substrate heater and post heat treatment. Each sputtering parameter during the sputtering deposition is an important factor for the high quality of ITO thin films deposited on polymeric substrate. Particularly, the material, electrical and optical properties of as-deposited ITO oxide films are dominated by the ratio of oxygen partial pressure. As the experimental results, the excellent ITO films are prepared on PET substrate at the operating conditions as follows : operating pressure of 5 mTorr, target-substrate distance of 45mm, do power of 20~30W, and oxygen gas ratio of 10%. The optical transmittance is above 80% at 550 nm, and the sheet resistance and resistivity of films are 24 Ω/square and $1.5\times$10$^{-3}$ Ωcm, respectively.

  • PDF

Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas (혹한기 지역에서의 자연순환형 태양열 시스템 동파방지)

  • Kwon, Jae-Wook;Kim, Jong-Hyun;Hong, Hi-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

Design and Fabrication of a Conductively Cooled Cryostat by Cryocooler (냉동기 부착형 전도냉각식 Cryostat의 설계 및 제작)

  • Bae, Joon-Han;Sim, Ki-Deck
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1921-1924
    • /
    • 2007
  • In order to measure the superconducting transition temperature, the critical current and the alternating current(AC) loss on short samples of high temperature superconductor, a cryocooler cooled cryostat has been designed and built. Two closed-cycle coolers provide cooling with an ultimate sample temperature below 16K. Temperature regulation is provided by 50W of electrical heater that opposes the cooling power from the cold heads. Temperature control feedback is by means of a cernox temperature sensor co-located with the heaters on the second stage of the cold head. Additional temperature sensors are located on the sample mount(B1), on the CVI cold head(B2) and on the Dakin cold head(B3). AC losses on the sample high temperature superconductor were measured at 30K so that the developed device performance was evaluated. In this paper, the design, fabrication and test results on the cryocooler cooled cryostat are presented.

A Study on Cartridge heater design for heating Hotplate to uniform surface temperature (핫플레이트를 균일온도로 가열하기 위한 카트리지히터 제작에 관한 연구)

  • Hong, Jae-Tack;Choi, Shin-Hyeong;Lee, Bong-Seob;Lee, Jin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.440-441
    • /
    • 2018
  • 본 연구에서는 핫플레이트를 균일한 표면 온도로 가열시키기 위한 카트리지 히터의 설계를 시도하였다. 이를 위하여 1. 표면 전력밀도 및 전열선 전력밀도에 따른 발열온도 측정 실험 2. 카트리지 히터의 분할 영역과 전열선 권선 비율에 따른 온도 측정 실험을 실시하여 온도분포형 카트리지 히터의 설계 사양을 선정하였다. 또한 이렇게 설계한 카트리지 히터를 직접 제작하여 기존의 표준형 카트리지 히터와의 성능 비교 측정 실험을 실시하여, 본 연구에서 제시한 방법으로 제작한 카트리지 히터의 표면 온도 균일도가 우수함(표면 온도차 ${\leq}1.25[^{\circ}C]$)을 증명하였다.

  • PDF