• Title/Summary/Keyword: Heat-up time

Search Result 574, Processing Time 0.031 seconds

The Study on Clinical Characteristics of Taeeumin Dry-Heat Symptomatic Patten (태음인(太陰人) 조열병증(燥熱病證)의 임상적 특징에 대한 연구(硏究))

  • Kim, Yun-Hee;Kim, Sang-Hyuk;Jang, Hyun-Su;Hwang, Min-U;Lee, Jun-Hee;Lee, Eui-Ju;Koh, Byung-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.21 no.1
    • /
    • pp.85-98
    • /
    • 2009
  • 1. Objective The object of this study was to understand the clinical characteristics of the Taeeumin Symptomatic Pattem. 2. Methods The patients visiting the department of Sasang Constitution of Traditional Korean Medicine clinic from June to November of 2008 were used in this study. Those who showed a favorable turn after over ten days of medication and who showed up for at least two follow-up sessions were chosen among first-time visitors. Of these, 75 patients identified and verified to be of the TE type were chosen for the study sample. The Taeeumin were verified into two groups according to clinical symptoms into Exterior Cold Disease and Interior Heat Disease groups, of which the Interior Heat Disease group was further subdivided into the Galgeun-medicament group and the Cheongshimyeonja-tang group, based on questionnaire results. The Exterior Cold Disease group was set as the control group in order to contrast and compare it with the study group, the Interior Heat Disease group. 3. Results and Conclusions The questionnaire items shown to differentiate the Exterior Cold Symptomatic Patterm and the Interior Heat Symptomaic Pattern (indicating Heat-affceted Liver Symptomatic Pattern) were related to "dryness of stool," "dark urine colorm," "dryness of nose," and "dryness of lips." The items shown to differentiate the Galgeun-medicament group and the Cheongshimyeonja-tang group (of the Dry - Heat Symptomatic Pattern) were related to "nausea," "stifling sensations and palptation," "disturbed sleep," and "dizziness." Therefore, the sleep pattern, palpitation, dizziness, and nausea can be said to be indicators of the Interior Heat Symptomatic Pattern, and Dry-Heat symptoms are better distinctions between the Chongshimyeonja-tang group and the Galgeun-medicament group than Heat-affected Liver symptoms.

  • PDF

Peel Strength Analyses of Copper/Epoxy System (구리/에폭시 계의 필 접착력 분석)

  • 최광성;유진;이호영
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.4
    • /
    • pp.238-252
    • /
    • 1996
  • In order to study the effect of interface oxides on the adhesion strength of the copper/epoxy system, copper foils were immersed in black oxide or brown oxide forming solutions before lamination with epoxy prepregs, and variation of peel strength with the treatment time were investigated. Results showed that peel strength decreased rapidly up to 1 minute of treatment lime and remained constant in the case of the black oxide treated specimens, which was accompanied by the thickening of $Cu_2O$ at the Copper/Epoxy interface during the period. In contrast, peel strength increased rapidly up to 1 minute of treatment time and remained constant in the case of the brown oxide treated specimens, which could be ascribed to the thickening of CuO. Subsequent heat treatments of the Copper/Epoxy laminations at $120^{\circ}C$ in air showed that peel strength remained constant in the case of the black oxide treated specimens but decreased gradually in the case of the brown oxide treated specimens. Following XPS analyses revealed that the latter was possibly caused by the coalescence of CuO at the Copper/Epoxy interface into $Cu_2O$.

  • PDF

Shape-Stabilized Phase Change Materals : Frozen Gel from Polypropylene and n-Octadecane For Latent Heat Storage

  • Son, Tae-Won;Kim, Tae-Hun;Kim, Bong-Shik;Kim, Byung-Giu
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.375-375
    • /
    • 2006
  • The preparation methods are to be used as "melting method" and "absorption method", respectively. The reaction mixture in the reaction container was heating up the reaction mixture to $200^{\circ}C$ for 2 hour. The mixing time of lab scale preparation should be provided quit long, instead of the short working time in a compounder vessel. And The PP-PCM mixture in the reaction container was heating up the mixture around $60-80^{\circ}C$ for 2 hour. A melting method of frozen gel with 50/50 weight ratio of polypropylene-normal octadecane was prepared by adding PP chip and normal octadecane. An absorption method of frozen gel with 70/30 weight ratio of PP 4.8-normal n-octadecane was prepared by adding PP powder and normal octadecnae.

  • PDF

An Influence of Groundwater Flow on Performance of Closed Borehole Heat Exchangers (Part-2) (지하수류가 밀폐형 천공 지중 열교환기 성능에 미치는 영향(2))

  • Hahn, Jeongsang;Kiem, Youngseek;Lee, Juhyun;Lee, Byoungho;Hahn, Chan
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.114-127
    • /
    • 2016
  • An increase of groundwater flux in BHE system creates that ground temperature (locT) becomes lower in summer and higher in winter time. In other words, it improves significantly the performance of BHE system. The size of thermal plume made up by advection driven-flow under the balanced energy load is relatively small in contrast to the unbalanced energy load where groundwater flow causes considerable change in the size of thermal plume as well ground temperature. The ground temperatures of the up gradient and down gradient BHEs under conduction only heat transport are same due to no groundwater flow. But a significant difference of the ground temperature is observed between the down gradient and up gradient BHE as a result of groundwater flow-driven thermal interference took placed in BHE field. As many BHEs are designed under the obscure assumption of negligible groundwater flow, failure to account for advection can cause inefficiencies in system design and operation. Therefore including groundwater flow in the design procedure is considered to be essential for thermal and economic sustain ability of the BHE system.

Evaluation of Thermal Characteristics in Association with Cement Types in Massive Concrete Structure (매스콘크리트 구조물에서의 시멘트 종류별 수화발열 특성 평가)

  • 김상철;강석화;김진근
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.6
    • /
    • pp.3-12
    • /
    • 1999
  • The larger, loftier and more highly strengthened the recent structures become, the greater attention is paid to the problem of thermal crack occurrence associate with hydration heat. As one of methods to solve the problem, a care has been taken to the improvement of construction such as the application of pre-cooling or pipe-cooling, adjustment of concrete block size, concrete placement timing, joint arrangement and so on. But it is expected that a proper selection of cement shall additionally contribute to the control of thermal cracks. In this study, thus, we selected 4 types of cements such as Type V for anti-sulphate, blast furnace cements (slag content of 45% and 65% respectively)and ternary blended low heat cement, and carried out mock-up tests. In every assigned time, temperatures and thermal stresses were measured and calculated from raw data. As a result of measurement, it was found that the magnitude of hydration heat is in order of blast furnace slag cement. Type V and ternary blended low heat cement. Results of thermal stresses were same as the order of temperature. In addition, thermal stresses calculated from the data of strain gauges showed almost similar to those measured from effective stress gauges only when strain values were adjusted properly in accordance with initial time of stress appearance. Theoretical results agreed well with the measured values comparatively, but showed slight differences. It is inferred that these differences shall be reduced if more tests capable of evaluating thermal characteristics of concrete are carried out.

Heat transfer characteristics with materials of the filler and flow path in vehicle washer heater system (차량워셔액 가열시스템에서 충전재 및 유로의 재질에 따른 열전달 특성 연구)

  • Cha, Woo Sub;Kim, Tae Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2628-2634
    • /
    • 2014
  • Vehicle washer heater system is more widely adopted to defrost a window or to clear the windshield glass in winter season. The washer heater system should be designed to heat up washer fluid rapidly to the target temperature for only a short time. A numerical analysis has been carried out to analyze the heat transfer characteristics with materials of inside parts in vehicle washer heater system with filler and flow path. ANSYS - FLUENT software is employed for the analysis. The axial symmetry model is three-dimensional and unsteady. It applies to the coupled method which is one of pressure based. Through this result, it was obtained to find the optimal material condition for the filler and flow path in washer system. For material of filler, the air with lower density was heated more rapidly rather than silicon carbide(SiC). For material of flow path, copper with the heat transfer coefficient of approximately four times greater than the nickel gives us higher efficiency. That is the reason why the heating time of methanol was reduced to make uniform temperature in washer heater system.

Validation of spent nuclear fuel decay heat calculation by a two-step method

  • Jang, Jaerim;Ebiwonjumi, Bamidele;Kim, Wonkyeong;Park, Jinsu;Choe, Jiwon;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.44-60
    • /
    • 2021
  • In this paper, we validate the decay heat calculation capability via a two-step method to analyze spent nuclear fuel (SNF) discharged from pressurized water reactors (PWRs). The calculation method is implemented with a lattice code STREAM and a nodal diffusion code RAST-K. One of the features of this method is the direct consideration of three-dimensional (3D) core simulation conditions with the advantage of a short simulation time. Other features include the prediction of the isotope inventory by Lagrange non-linear interpolation and the use of power history correction factors. The validation is performed with 58 decay heat measurements of 48 fuel assemblies (FAs) discharged from five PWRs operated in Sweden and the United States. These realistic benchmarks cover the discharge burnup range up to 51 GWd/MTU, 23.2 years of cooling time, and spanning an initial uranium enrichment range of 2.100-4.005 wt percent. The SNF analysis capability of STREAM is also employed in the code-to-code comparison. Compared to the measurements, the validation results of the FA calculation with RAST-K are within ±4%, and the pin-wise results are within ±4.3%. This paper successfully demonstrates that the developed decay heat calculation method can perform SNF back-end cycle analyses.

Transcriptional Response of Major Antioxidant Enzyme Genes to Heat Stress in Mud Loach (Misgurnus mizolepis) (고온 스트레스에 대한 미꾸라지(Misgurnus mizolepis) 항산화 효소 유전자들의 발현 특징)

  • Cho Young-Sun;Lee Sang-Yoon;Bang In-Chul;Kim Dong-Soo;Nam Yoon-Kwon
    • Journal of Aquaculture
    • /
    • v.19 no.3
    • /
    • pp.157-165
    • /
    • 2006
  • Expression of major antioxidant enzyme (AOE) including Cu/Zn superoxide dismutase (Cu/Zn-SOD), catalase (CAT), glutathione-S-transferase (GST) and 3 glutathione peroxidase isotypes (GPXs) at mRNA levels during heat stress was examined in mud loach (Misgurnus mizolepis) liver. Based on the semi-quantitative RT-PCR, real-time RT-PCR and/or northern dot blot hybridization, the antioxidant enzyme genes were generally up-regulated during elevation of water temperature from $23^{\circ}C$ up to $32^{\circ}C$. GPXs and SOD displayed the most significant elevation of mRNA levels (up to 3 and 2 folds, respectively) while CAT showed the steady-state expression irrespective of thermal conditions. GST represented the relatively moderate response (1.3-fold increase) in its transcription to thermal stress. The transcriptional activation of AOE genes was not significant at the treatment temperature lower than $29^{\circ}C$. Increased mRNA levels of GPX (extracellular form) and SOD genes in the fish exposed to $32^{\circ}C$ was readily detectable 1 day after exposure to heat stress.

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

Dissolution Behavior of Complex Carbonitrides in a Microalloyed Steel (Microalloyed 강에서 복합 탄질화물의 재용해 거동)

  • Jung, Jae-Gil;Park, June-Soo;Ha, Yang-Soo;Lee, Young-Kook;Bae, Jin-Ho;Kim, Kisoo
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.6
    • /
    • pp.287-292
    • /
    • 2008
  • Dissolution behavior of complex carbonitrides in a Nb-Ti-V microalloyed steel was quantitatively examined by electrical resistivity, transmission electron microscopy (TEM), and optical microscopy. The electrical resistivity increased with solution treatment temperature up to $1250^{\circ}C$ for a holding time of 15 min. But, an increasing rate of electrical resistivity with temperature was obviously decreased above $1150^{\circ}C$. As the solution treatment temperature increases, irregular shaped Nb-rich carbonitrides disappear and cuboidal Ti-rich carbonitrides are observed. Abnormal grain growth occurs above $1250^{\circ}C$ for a holding time of 15 min. The optimal solution treatment temperature of a Nb-Ti-V microalloyed steel was determined as $1200^{\circ}C$ for a holding time of 15 min.