• Title/Summary/Keyword: Heat-setting

Search Result 377, Processing Time 0.064 seconds

Temperature Control Improvement of Pressure Heating Roller for Flexible Flat Cable Production (Flexible Flat Cable 생산성 향상을 위한 가압용 히팅롤러의 온도제어개선)

  • Kim Jae Hak;Lee Ho Jung;Chun Keyoung Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.155-163
    • /
    • 2005
  • Pressure heating rollers with temperature control were mounted to a flat cable laminating machine (FCLM). Pressure heating rollers should be heated up to the setting temperature $(175^{\circ}C)$ and kept on to producing good quality flexible flat cables (FFC). Existing Pressure heating rollers took more than 70minutes to the setting temperature and did not keep on the setting temperature in production. Temperature controller, electric power controller, material and diameter of rollers and heat capacities were changed to improve the temperature control of the pressure heat rollers for better production of the FFC. Thus, the reaching time to the setting temperature (RT), temperature stability time (TST) and temperature hunting (TH) were measured and compared with the existing pressure rollers case. The RT of A roller was shortened by 50minutes, and B roller was shortened by 15minutes. The TST of A roller was shortened by 13minutes, and B roller was shortened by 15minutes. The THs of both A and B rollers were settled up to ${\pm}5^{\circ}C$. Finally, the productivity of the FCLM and the quality of the FFC were increased.

Investigation on the Applicability for Method of Setting Time Difference by Super Retarding Agent for Reducing Hydration Heat of Transfer Girder Mass Concrete (전이보 매스콘크리트의 수화열저감을 위한 초지연제 응결시간차 공법의 적용가능성에 대한 검토)

  • Yoon Seob;Hwang Yin Seong;Baik Byung Hoon;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.128-131
    • /
    • 2004
  • This paper is to investigate the mock up test results of mass concrete for transfer girder using setting time difference with super retarding agent(SRA) to reduce hydration heat. According to test results, the temperature history of plain concrete without placing lift had a steep rising curvature, and plain concrete had a big temperature difference between surface and middle section of mass concrete, which may result in occurrence of temperature crack. However, considering placing method B, because setting time of middle section concrete was retarded with an increase in SRA contents, higher hydration heat temperature was observed at surface section concrete compared with that at middle section concrete at early age, which can lower the possibility of hydration heat crack. In case of placing method C, although peak temperature of hydration heat was much lower, at early age, high crack occurrence possibility of the hydration heat attributable to the big temperature difference between middle section and bottom section of concrete was expected at bottom section concrete. Therefore, the structure above the ground like transfer girder is not applicable to consider the placing method C.

  • PDF

Field Application of the Mass Concrete Utilizing Combined Method for Temperature Crack Reduction (온도균열 저감공법을 복합사용한 매스콘크리트의 현장적용)

  • Han, Sang-Yoon;Lee, Chung-Sub;Baek, Dae-Hyun;Jang, Duk-Bae;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.37-39
    • /
    • 2010
  • In this study, with new office construction site of S Construction company as subject, to solve all the problems according to reduced hydration heat and temperature crack of mass concrete used mat foundation and placing time difference, low heat combination of coarse particle cement and fly-ash and setting time difference applied AE water reducing agent, and to prevent the early frost damage caused by low outdoor temperature, a heat insulation method using double bubble sheet was conducted. As a result, it was found that hydration heat and setting time difference was reduced by applying a low heat combination and setting time difference construction method, and that the high insulation capability of the double bubble sheet was able to not only prevent the early frost damage but also reduce temperature difference between the central part and the upper part of mass concrete.

  • PDF

A COMPARISON OF THE SETTING CHARACTERISTICS BETWEEN RESIN-MODIFIED GLASS-IONOMERS AND COMPOMERS (Resin-Modified Glass-Ionomer와 Compomer의 경화 반응 특성의 비교에 관한 연구)

  • Ko, Yong-Joon;Yoo, Hyeon-Mee;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.123-132
    • /
    • 2000
  • To overcome problems of conventional glass ionomers, resin components have been added to glass ionomers. On a continuum between glass ionomers and composites are a variety of blends, employing different proportions of acid-base and free radical reactions to bring about cure. Popular groups defined between the ends are resin-modified glass-ionomers(RMGIs), polyacid-modified composite resins(Compomers) and ionomer modified resins. These groups show different clinical properties, and in selecting these materials for a restoration, one should sufficiently understand these different setting properties. In this study, some difference in the setting characteristics of different groups of hybrid ionomers were examined. Two RMGIs (Fuji2 LC,GC / Vitremer, 3M), three Compomers (Dyract AP, Dentsply / F2000, 3M / Elan, Kerr) were involved in this study. The identification of the setting characteristics of different groups was achieved by a two-stage study. First, thermal analysis was performed by a differential scanning calorimeter, and then the hardness of each group at different depth and time were measured by a micro-hardness tester. Thermal analysis was performed to identify the inorganic filler content and to record the heat change during setting process. The setting process was progressed for each material by chemical set mode and light-cured mode. In the hardness test, samples of materials were prepared with a 6mm-diameter metal ring, and the hardness was measured at the top, and 1mm, 2.5mm, 4mm below at just after a 40 second-cure, and after 10 minutes, 24 hours, and 7 days. Statistical analysis was performed by Mann-Whitney rank sum test to assess significant differences between set modes and types of materials, and by ANOVA and T-test to evaluate the statistical meanings of data at different times and depths of each materials. Followings are findings and conclusions derived from this study. Thermal analysis; 1. Compomers show no evidence of chemical setting while RMGIs exhibit heat output during the process of chemical setting. 2. Heat of cure of RMGIs exceed Compomers. 3. The net heat output of RMGIs through light-cured mode is higher than through chemically set mode. Hardness test; 1. Initial hardness of RMGIs immediately after light cure is relatively low, but the hardness increases as time goes by. On the contrary, Comomers do not show evident increase of the hardness following time. 2. Compomers show a marked decrease of setting degree as the depth of the material increases. In RMGIs, the setting degree at different depths does not significantly differ.

  • PDF

Effect of heat setting on physical properties of dyeable polypropylene(DPP) fabric (가염형 폴리프로필렌직물의 열처리에 따른 물성변화)

  • Lee, Sin-Hui;Kim, Eun-Mi
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2008.04a
    • /
    • pp.37-39
    • /
    • 2008
  • The purpose of this study is to improve the defects of DPP fabric by heat setting and to describe the change of physical properties of DPP fabrics. The thermosetting was carried out in autoclave from 100 to 140$^{\circ}C$ temperature range for 10min.. In this study, we investigated the effect of the thermosetting temperatures on the structural, thermal, mechanical properties and dyeability of DPP fabrics. The melting peak of multi peak changed to single peak with an increased thermosetting temperatures. The melting energy(J/g), the tensile strength and elongation were found to increase with increasing temperature of heat setting. The diffraction peak at Bragg angle(2${\theta}$) about 13.8$^{\circ}$ were very strong, and diffraction intensity, d-spacing and half-width decreased with increasing thermosetting temperatures. On the other hand, the dyeability(K/S) and crease recovery decreased with an increasing thermosetting temperatures.

  • PDF

Dyeing and Heat Setting Properties of Low Melting PET Fiber (저온융착사를 이용한 섬유의 염색성 및 열처리 특성)

  • Hwang, Se-Jeong;Choi, Hyun-Seuk;Kim, Dong-Kwon;Chong, In-Sik;Kim, Sung-Gun
    • Textile Coloration and Finishing
    • /
    • v.21 no.3
    • /
    • pp.37-42
    • /
    • 2009
  • The low melting PET yarn has sheath/core structure: sheath portion consists of low melting point PET and core portion is regular PET. Dyeing properties of fabric made from low melting PET yarn were investigated at different dyeing temperatures. It was found that the exhaustion yield on the low melting PET fabric was higher than on regular PET fabric. The total K/S value of the dyed low melting PET fabric increased as heat setting temperature increased above $150^{\circ}C$ because the sheath portion of the low melting yarn melted. Although fastness to light of the low melting PET fabric was similar to regular PET fabric, fastness to washing was inferior to regular PET fabric by 1 grade.

Improvement in the Color Fastness of Cotton Fabrics Dyed with Kale-Extracted Colorants (케일 추출 색소로 염색된 면직물의 염색견뢰도 향상)

  • Lee, Yeonjoo;Kwak, Sukyung;Jang, Jinho
    • Textile Coloration and Finishing
    • /
    • v.31 no.4
    • /
    • pp.225-232
    • /
    • 2019
  • The colorants of kale powders were optimally extracted using an 1:1 mixture solvent of ethanol and DMSO at 105℃ for 30 minutes obtaining a high yield of 359.7㎍/mL chlorophylls. Low color fastness of the dyed fabrics with the extracts, particularly against washing and solar radiation, can be overcome by the combined treatments of chitosan, heat setting and tannic acid. Washing fastness to color change was improved from rating 1-2 up to 5 due to the enhanced electrostatic interactions between the colorants and the positive glucosamine unit of the chitosan in the cationized cotton. In addition, the tannic acid treatment contributed to the additional increase in color fastness after the sequential treatments of chitosan pretreatment, dyeing and heat setting.

Influence of Limestone Powder on the Hydration of Cement Contained much Chloride (석회석 미분말이 염소고함유시멘트의 수화반응에 미치는 영향)

  • Jeong, Chan-Il;Lee, Eui-Hak;Lee, Kyung-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.9 s.292
    • /
    • pp.537-543
    • /
    • 2006
  • Length change, hydration heat, setting time and compressive strength of OPC were measured by adding KCl and replacing limestone powder so as to examine the influence of limestone powder on hydration of the OPC contained much chloride. In general, the chloride modified cement was high in heat of hydration, short in its setting time, low in its fluidity and low in its strength at 28 days due to the sudden hydration in its initial stage. As a result of the experiment, it has been demonstrated that heat of hydration, became low as one replaced limestone powder to the chloride modified cement, and the fluidity and shrinkage rate of mortar decreased without change in setting time; furthermore, the compressive strength at 28 days was improved.

The Effect of Aftertreatment Conditions on the Dyeability of PET Filament (Poly(ethylene terephthalate) filament의 후처리 조건이 염색성에 미치는 영향)

  • Lee, Dae-Soo;Han, Myeong-Hee
    • Textile Coloration and Finishing
    • /
    • v.2 no.3
    • /
    • pp.1-7
    • /
    • 1990
  • The crystallinity and dyeability of PET filament were studied when the conditions of drawing and heat-setting were varied. The crystaltinity of PET filament was increased as the drawing ratio and heatsetting temperature were increased. The dye uptake and dyeing rate of PET filament were decreased as the drawing ratio was increased. With increasing the heat-setting temperature, however, the dye uptake and dyeing rate were decreased at an early stage, showing the minimum at $160^{\circ}C-180^{\circ}C$ and then increased above that temperature. The thermal shrinkage of PET filament was decreased as the drawing ratio was increased, while increasing as the heat-setting temperature was increased.

  • PDF

A Fundamental Study on the Control of Hydration Heat of Mass Concrete Using Setting Time Difference (응결시간차를 활용한 매스콘크리트의 수화열 조정에 관한 기초적 연구)

  • 배정렬;윤치환;김기철;한민철;오선교;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.41-45
    • /
    • 2002
  • Placing lift is applied to place mass concrete in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF