• Title/Summary/Keyword: Heat-setting

Search Result 377, Processing Time 0.024 seconds

Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design (온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.204-211
    • /
    • 2019
  • The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to $16.3^{\circ}C$ and $14.6^{\circ}C$ during the experiment, respectively. The average water temperature in heating pipes was $52.3^{\circ}C$ and $45.0^{\circ}C$, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of $5.71{\sim}7.49W/m^2^{\circ}C$. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.

The Behavior of Chill Layers with Temperature Variation of Shot Sleeve in Aluminum Diecasting Process (알루미늄 다이캐스팅 공정에서 사출 슬리브 온도변화에 따른 파단칠층의 거동)

  • Park, Jin-Young;Kim, Eok-Soo;Park, Ik-Min
    • Journal of Korea Foundry Society
    • /
    • v.25 no.4
    • /
    • pp.168-172
    • /
    • 2005
  • In this study, the effects of chill layers occurred in shot sleeve on the molten metal filling were analyzed through computer simulation and the behavior of chill layers with temperature variation of shot sleeve set from 200 to $280^{\circ}C$ was also investigated. The simulation results showed the chill layers set in the in-gates during the injection process change the main filling direction and cause turbulent flow pattern, resulting in porosities inside the castings. The amount of chill layers with the increasing temperature of shot sleeve was considerably reduced. And particularly, at the setting temperature of $280^{\circ}C$ by heat control unit, the big reduction in chill layers, excellent trimmed surface and the highest densification were achieved, suggesting that as the optimal sleeve condition in diecasting, especially for the highly complex parts like valve body.

Blast Furnace Slag Powder High Volume Substitution Mortar Quality Increase Due To Changes in Desulfurized Plaster Processing Method (탈황석고의 처리방법 변화에 의한 고로슬래그 미분말 다량 치환 모르타르의 품질향상)

  • Song, Yuan-Lou;Park, Yong-Jun;Kim, Sang-sup;Lee, Dong-Yun;Jang, Duk-Bae;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.55-56
    • /
    • 2015
  • In this research the processing method of Desulfurized Plaster is changed to cyclotomy, 0.3mm sieve analysis and 500℃ heat exposure, and by changing the mix rate of the binding agent to 0~20%, it was applied to mortar that used natural aggregate and blast furnace slag for testing. The test results showed that the sieve analysis and high heat exposure of the flow and air volume increased according to the increase of mixing rate of FGD while the cyclotomy decreased. The setting time accelerated as the mixing rate of FGD increased, and the compression strength increased to its maximum when the mixing rate of FGD was right around 10%, and especially showed a high trend with cyclotomy and sieve analysis.

  • PDF

Influence on Compressive Strength and Drying Shrinkage of Concrete with Urea-Water Soluble Sulfur Admixture (요소-수용성 유황 혼화제가 콘크리트 압축강도 및 건조수축에 미치는 영향)

  • Park, Jae Kyu;Han, Sang Hoon;Hong, Ki Nam;Cho, Yong In;Chai, Yuzhe
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.74-81
    • /
    • 2016
  • This paper presents an experimental study to ivestigate mechanical property of concretes according to addition of urea and urea-water soluble sulfur contents. Urea was added at 5~20% replacement by weight of water, and water soluble sulfur was used at 2%, 4% replacement by weight of cement. The setting times, the hydration heat, the compressive strength, and the drying shrinkage, were measured on concretes with single and binary admixtures. From the test result, it was confirmed that the hydration heat of urea-water soluble sulfur was lower than that of normal concrete by $10.1^{\circ}C$, and the drying shrinkage of urea-water soluble sulfur concrete was more excellent than normal concrete. In the case of urea of 5%, Compressive strength were improved with an increase of water soluble sulfur contents. The urea-water soluble sulfur used in this research can be used as improvement materials for drying shrinkage and compressive strength.

The Planning of Micro-climate Control by Complex Types (단지 유형에 따른 도시의 미기후 조절 계획에 관한 연구)

  • Jeong, Juri;Chung, Min Hee
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.49-54
    • /
    • 2017
  • Purpose: Temperature in urban areas increase much more than suburban areas and it is called urban heat island (UHI) phenomenon. There are several solutions to control UHI phenomenon such as green roof system, water space construction, and cool roof system. However, application of green roof system and cool roof system to some of the buildings which compose the city has a critical limit. Therefore, in order to diminish the temperature rising and UHI phenomenon due to climate change of the city, it needs to approach from the viewpoint of site or city, rather than the viewpoint of individual buildings. This study is aims at analyzing UHI phenomenon by characteristics of surface materials and suggesting the solutions to reduce UHI phenomenon by types of complex. Method: Literature reviews were conducted to analyze the cause, mitigating plan, and recent trends of UHI phenomenon. For the simulation analysis, the type of complex was classified 3 representative complex. Based on measured reflectivity, simulation about UHI phenomenon was conducted by setting 4 strategies; albedo of roof, road pavement, green roof system, and vegetating around buildings. Result: As the results of simulating the UHI reduction factor by types of complex, it showed that the effect of temperature reduction on the building roof layer is more effective than adjusting the reflectivity of buildings such as green roof system, planting near the buildings in both the detached house complex, apartment complex, and commercial complex.

Effect of Bead Surface Treatments and Bead Shapes on the Drawing and Friction Characteristics in Drawbead Forming of Sheet Metal (판재의 드로우비드 성형시 비드표면처리와 비드형상이 인출 및 마찰특성에 미치는 효과)

  • Lee, Dong-Hwal;Ryu, Jong-Soo;Chung, Woo-Chang;Moon, Young-Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.2
    • /
    • pp.105-111
    • /
    • 2005
  • In sheet metal forming, drawbeads are often used to control uneven material flow, which may cause defects such as wrinkles, fractures, surface distortion and springback. Appropriate setting and adjusting of the drawbead force is one of the most important parameters in sheet forming process control. Therefore in this study, drawbead test was performed at various bead surface treatment conditions to clarify the frictional characteristics between sheet and drawbead. Furthermore, the differences in drawing force between circular and rectangular shape beads have also been measured to estimate the effectiveness of bead shape on the material flow control. The results show that drawing and friction characteristic were strongly influenced by surface treatments of bead and bead shapes.

A study on the optimum control of refrigerator with on-off control system (On-off 제어계통을 갖는 냉동기의 최적제어에 관한 연구)

  • Ha, J.S.;Kim, W.N.;Kim, K.K.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.317-327
    • /
    • 1985
  • In the case of temperature control of air conditioning and refrigerating system, it is possible to operate the system continuously by controlling the cooling capacity of refrigerating machines. But on-off control system has been adopted for refrigerating system which has more large capacity than that required to remove the generated heat. In this on-off control system, it can be considered that there exists some optimum condition for the refrigerating capacity, operating cycle, running hour, and the temperature difference between thermostat setting value and real one. In this paper, an equation was derived to express the temperature variation of the refrigerated object (Nybrine) and later two evaluating functions were derived. One is for the temperature difference and another is for operating cycle and running hour. The weighted sum of these two functions is defined as the criterion function for the evaluation of the control performance of the system, and then the optimum running condition is investigated in the sense of minimizing the criterion function. Experiments showed that the heat balance equation derived for the temperature variation and the estimation of the time constant of the refrigerated system are appropriate. By conclusion, if a proper weighting factor D is selected, the optimum conditions exist for the refrigerating capacity, running hour, and operating cycle in the on-off temperature control of the refrigerating system.

  • PDF

Experiments on Operation Characteristics of In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열 시스템의 운전특성 실험)

  • Choe, In-Su;Kim, Jae-Dol;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.653-659
    • /
    • 2001
  • This paper is concerned with the development of a new method for making and separating ice in-water and saving floated ice by installing an evaporation panel in an ice storage tank. The new method shows very good heat transfer efficiency than that of the convectional method. It is because the evaporation panel is directly contacted with water in the storage tank. The experiments were performed by varying inlet and outlet refrigerant temperatures of its evaporator. From the experimental results, the operating characteristics of in-water harvest-type ice storage system were investigated by measuring temperature and pressure at each point of the ice storage system and power required to operating compressor respect to the changes of the inlet and outlet refrigerant temperature of evaporator. It can be think that defrost frequency decreased and heavy ice created as the refrigerant temperature of evaporator outlet and defrost setting temperature is low so gotten result can effect to release efficiency. Also, consumption power, condensing heat quantity, refrigerating capacity and performance efficiency decreased as time goes by. Therefore, these results provide the basic data for system optimization, performance improvement and the possibility of application to other fields.

Durability of High Early Strength Concrete Using Fine Particles Cement (미립자 시멘트를 이용한 조강 콘크리트의 내구성 검토)

  • Kim, Yong-Jic;Park, Sang-Joon;Kim, Kyoung-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.757-763
    • /
    • 2011
  • In order to secure the effective high early age strength of the concrete, the study was carried out with a goal of functional improvement of cement. This study was carried out as a follow up for the previous study, which analyzed the high early age strength and durability of concrete mixed with fine particle cement (FC) during cement production. The experimental results showed that the target range for each mix was satisfied at fresh state of concrete. Also, when mixed with fine particles cement, the setting time improved. Additionally, compressive strength and heat of hydration increased and remained same, respectively. Especially, the durability remained same even when mixed with fine particle cement.

Fundamental Characteristics the Concrete According to Mixing Methods and Unit Water Content of Ternary Blended Cement (3성분계 시멘트의 단위수량 및 혼합방식에 따른 콘크리트의 기초특성)

  • Lee, Il-Sun;Hong, Seak-Min;Baek, Dae-Hyun;Kim, ki-hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.133-136
    • /
    • 2009
  • This study analyzes the mixing and basic characteristics of concrete according to the unit quantity and mixing method of ternary blended cement and the results of this study can be summarized as follows. In the case of the premixed cement (hereafter referred as POBF) of POBF135, it satisfies the target level of fluidity and air content in which it shows relatively small bleedings even though it represents the latest initial and final setting. Also, although the POBF135 represents small initial strength, it shows an increase in the strength according to the increase in aging. In addition, it shows the lowest temperature in the POBF135. As a result, it can be seen that the POBF135 indicates the most optimal mixing subject to considering the aspect of fluidity, compressive strength, and heat of hydration in general figures.

  • PDF