• 제목/요약/키워드: Heat-generating

검색결과 291건 처리시간 0.026초

채널 유동장 내에 배열된 전자부품의 강제대류 냉각특성에 관한 연구(II) -레이놀즈 수의 영향(히트싱크가 부착되지 않은 경우)- (Cooling Characteristics on the Forced Convection of an Array of Electronic Components in Channel Flow (II) - The Effect of the Reynolds Number (without the Heat Sink) -)

  • 김광수;양장식
    • 설비공학논문집
    • /
    • 제18권6호
    • /
    • pp.509-517
    • /
    • 2006
  • Present study is concerned with an experimental study on the cooling characteristics of heat-generating components arranged in channels which are made by printed circuit boards. To estimate the thermal performance of the heat-generating components arranged by $5\times11$ in channel flow, three variables are used: the inlet velocity, the height of channel, and row number of the component. The cooling characteristics of the heat-generating components such as the surface temperature rise, the adiabatic temperature rise, the adiabatic heat transfer coefficient, and the effect of thermal wake are compared with the result of the experiment and the numerical analysis. The experimental result is in a good agreement with the numerical analysis. The heat transfer coefficient increases as the Reynolds number increases, while the thermal wake function calculated for each row decreases as the Reynolds number increases. In addition, it is found that Nu-Re correlation equation is Identical to the previous studies, and the empirical correlation equation between the thermal wake function and Re is presented.

저발열 결합재 및 W/B 변화에 따른 저열콘크리트의 공학적 특성 (Engineering properties of low heat concrete depending On low heat binder and the change in W/B)

  • 곽용진;손호정;김경민;박상준;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.69-70
    • /
    • 2012
  • This paper is to investigate the engineering properties of the concrete incorporating different types of low heat generating binders subjected to various W/B. As expected, it is found that increase of W/B resulted in a decrease of hydration heat and compressive strength. It also showed that the application of high early strength and low carbon type mixture had favorable strength development at early and later age, while hydration heat showed rather higher than existing low heat mixture.

  • PDF

마이크로 강섬유와 MWCNT를 혼입한 전도성 모르타르의 발열성능, 휨강도 및 미세구조 분석 (Analysis of Heat-generating Performance, Flexural Strength and Microstructure of Conductive Mortar Mixed with Micro Steel Fiber and MWCNT)

  • 최범균;허광희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권3호
    • /
    • pp.47-58
    • /
    • 2024
  • 본 연구에서는 마이크로 강섬유와 다중벽 탄소나노튜브(multi-walled carbon nanotube, MWCNT)를 혼입한 전도성 모르타르의 발열성능, 휨강도 및 미세구조를 분석하기 위해 실험적으로 수행하였다. 전도성 모르타르 발열성능 및 휨강도 시험에서 MWCNT의 혼입 농도는 시멘트 중량 대비 0.0wt%, 0.5wt% 및 1.0wt%로 선정하였으며, 마이크로 강섬유는 부피 대비 2.0vol%로 혼입하였다. 발열성능 실험은 다양한 인가전압 (DC 10V, 30V, 60V) 및 상이한 전극간격 (40 mm, 120 mm)을 매개변수로 수행하였으며, 양생 재령 28일에서 휨강도를 측정하여 일반 모르타르와 비교, 분석하였다. 더 나아가, 전계방사 주사전자현미경(field emission scanning electron microscope, FE-SEM)을 이용하여 전도성 모르타르의 표면 형상과 미세구조를 분석하였다. 그 결과 MWCNT의 혼입 농도와 인가전압이 증가할수록 발열성능이 향상되었으며, 전극간격이 좁을수록 발열성능이 더욱 향상되는 것으로 나타났다. 하지만 MWCNT의 혼입 농도를 1.0wt%까지 추가하더라도 발열성능은 크게 향상되지 못하였다. 휨강도 시험결과, PM 시편과 MWCNT를 혼입한 시편을 제외한 모든 시편의 평균 휨강도가 4.5 MPa 이상으로 나타나 마이크로 강섬유 혼입에 따른 높은 휨강도를 보였다. FE-SEM 이미지 분석을 통해 시멘트 매트릭스 내 마이크로 강섬유와 MWCNT 입자 사이에 전도성 네트워크가 형성되는 것을 확인하였다.

스크레퍼형 슬러리아이스 제빙기의 열전달 특성 연구 (A Study on the Heat Transfer Characteristics of Slurry Ice Generator using Scraper)

  • 김종하;윤재호;김민준;김규진;조형석;안성국
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.144-149
    • /
    • 2006
  • In this study ice making characteristics are experimentally investigated for the ice slurry generating system which is pneumatically operated. The experimentations are conducted under the various test conditions such as chilled water inlet temperature, aqueous solution concentration, flow rate of cooling water, scraper pitch and frequency of cylinder stroke. For the above experimental conditions, ice making characteristics of the slurry ice generating system are evaluated in terms of the overall heat transfer coefficient, heat transfer rate and the amount of slurry ice generation. And the experimental results show that the heat transfer rate of the system increases as the flow rate of cooling water solution increases and the concentration of ethylene glycol and inlet temperature of chilled water decreases.

  • PDF

發熱核 주위의 수령圓環 에서의 자연대류 (Natural Convection in a Horizontal Cylindrical Annulus Enclosing Heat Generating Core)

  • 장근식;오세윤
    • 대한기계학회논문집
    • /
    • 제9권5호
    • /
    • pp.663-676
    • /
    • 1985
  • 수평원통형의 복합유동층에서의 층류자연대류를 수치적으로 연구하였다. 외측의 동심원환이 내 의 발열유체로 형성된 원통형 핵을 둘러싸고, 그 사이에 두께가 유한하거나 두께를 무시할 수 있 는 간막이 벽이 존재한다. 유동특성과 열전달에 관한 매개변수적 고찰을 시행하거나 직경비, Prandt1수, 발열강도에 기준을 둔 Rayleigh수 등의 영향을 이해하게 되었다. 간막이 벽의 두께나 열전도의 효과도 제한된 범위 안에서 고려하였다.

스크레이퍼형 아이스슬러리 제빙기의 열전달 특성 연구 (A Study on the Heat Transfer Characteristics of Ice Slurry Generator with Scraper)

  • 김민준;김종하;윤재호;박일환;조형석;안성국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1974-1979
    • /
    • 2007
  • In this study, Ice slurry generator heat transfer characteristics are experimentally investigated for the ice slurry generating system with scraper which is pneumatically operated. The ice slurry generator has the same shape as the vertical double tube type heat exchanger. Refrigerant is flowing in the outside tube and ethylene glycol solution in the inside tube. Refrigerant and solution water are parallel flow type which entering bottom of generator and leaving top of generator. The experimentations are conducted under the various test conditions such as compressor speed and cooling water temperature. For the above experimental conditions, heat transfer characteristics of the ice slurry generating system are evaluated in terms of the overall heat transfer coefficient and the heat transfer rate. And the experimental results show that the heat transfer rate of the system is increased as the compressor speed increases and the cooling water temperature decreases.

  • PDF

시설원예용 대온도차 지열원 히트펌프 운전비용 효과 분석 (Operating Cost Analysis of a High Temperature Ground Source Heat Pump System for a Greenhouse)

  • 강신형;박승병;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권1호
    • /
    • pp.17-22
    • /
    • 2016
  • It is very important to obtain a out-of season production in horticultural greenhouses corresponding with higher crop prices. A ground source heat pump system has been highly spotlighed as an energy efficient heating system for the greenhouse. This paper investigated the operating cost of the ground source heat pump system with the variation of generating temperature and designing methods for heating system of the greenhouse. Even though the COP of the ground source heat pump system decreased with an increment of generating temperature in heating mode, the operating cost could be reduced. By adopting the high temperature heat pump system and heat storage tank, it could be achieved to save energy and reduce the operating time of auxiliary oil heating system for producing good plant-growth in the greenhouse.

기포 펌프를 적용한 흡수식 열펌프용 고온 재생기의 작동 특성 실험 (Experiments on a Regenerator with Thermosyphon for Absorption Heat Pumps)

  • 박찬우;정종수;남평우
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.463-472
    • /
    • 1996
  • Experiments were carried out to study the operation characteristics of a regenerator with a thermo-syphon pump and a surface-flame burner for a lithium bromide (LiBr)-water absorption heat pump. A cylindrical-shape metal-fiber burner and commercial grade propane were used. The emission of carbon monoxide and nitric oxide was measured by a combustion gas analyzer. Ther regeneration rate of water vapor as a refrigerant was measured. It could be as a reference value showing the performance of the regenerator. The circulation rate of the LiBr-water solution was also measured from both the tanks for the weak-and the strong-solution. Using a refractometer, the LiBr concetration in the solution was calculated from the measured refractory index of the solution. Temperature of the solution and the condensed water was recorded at several points in the experimental apparatus with thermocouples, using a personal computer. This data collecting system for measuring temperature was calibrated with a set of standard thermometers. The generating rate of water vapor as refrigerant increased linearly with heat supplied. It was about 4.0g/s with the heat supplied at a rate of 16,500kcal/h. The circulation rate of LiBr solution also increases with the heat supplied. The difference in LiBr concentrations between the weak and the strong solution was in the range of 1 to 5% when the concentration of the strong solution was about 60%. It was dependent upon both the heat supplied and the circulation rate of the solution. The initial concentration and the level of the LiBr solution in the regenerator were measured and recorded before experiments. The effect of them on the generating rate of water vapor and the circulation rate of the solution was also studied. The generating rate of water vapor was not strongly dependent upon both the level of the LiBr solution and the initial LiBr concentration. However, the concentration difference of the solution increases with the initial level of the LiBr solution.

  • PDF

DEVELOPMENT OF HIGH EFFICIENCY COGENERATION SYSTEM USING BIOGAS FOR THE LOWER POLLUTION OF THE ENVIRONMENTAL

  • Park, J.S.;Ishii, K.;Terao, H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.670-675
    • /
    • 2000
  • The purpose of the study is development and investigation about basic performance of the system operation on a dual fueled cogeneration system(CGS), which is operated with biogas and gas oil. As often seen in dual fueled CGS performance, the electric generating efficiency was obtained about 26□. Methane contained in the biogas could not bum completely at lower load, and it was discharged into exhaust gas. Considerable amount of the methane burned in the exhaust pipe, and the heat recovery ratio was 42□ on heat balance. As a result, the total heat efficiency, which is a summation of generating efficiency and heat recovery efficiency reached to about 70□. The supply of biogas into the engine reduces smoke density and NOx concentration in exhaust gas. At lower load, methane burned slowly and large portion of it was discharged without burning. Therefore the measures are desirable that promotes combustion of methane at lower load.

  • PDF