• Title/Summary/Keyword: Heat-flow analysis

Search Result 2,055, Processing Time 0.031 seconds

An Analysis of Low-level Stability in the Heavy Snowfall Event Observed in the Yeongdong Region (영동지역 대설 사례의 대기 하층 안정도 분석)

  • Lee, Jin-Hwa;Eun, Seung-Hee;Kim, Byung-Gon;Han, Sang-Ok
    • Atmosphere
    • /
    • v.22 no.2
    • /
    • pp.209-219
    • /
    • 2012
  • Extreme heavy snowfall episodes have been investigated in case of accumulated snowfall amount larger than 50 cm during the past ten years, in order to understand the association of low-level stability with heavy snowfall in the Yeongdong region. In general, the selected 4 events have similar synoptic setting such as the Siberian High extended to East Sea along with the Low passing by the southern Korean Peninsula, eventually inducing easterly in the Yeongdong region. Specifically moist-adiabatically neutral layer has been observed during the heavy snowfall period, which was easily identified using vertical profiles of equivalent potential temperature observed at Sokcho, whereas convective unstable layer has been formed over the East sea due to relatively warm sea surface temperature (SST) about $8{\sim}10^{\circ}C$ and lower temperature around 1~2 km above the surface, obtained from RDAPS. Difference of equivalent potential temperature between 850 hPa and surface as well as difference between air and sea temperatures altogether gradually increased before the snowfall period. Instability-induced moisture supply to the atmosphere from the East sea, being cooled and saturated by the upper cold surge, would make low-level ice cloud, and eventually move inland by the easterly flow. Heavy snowfall will be enhanced in association with low-level convergence by surface friction and upslope wind against Taebaek mountains. This study emphasizes the importance of low level stability in the Yeongdong region using the radiosonde sounding and RDAPS data, which should quantitatively be examined through numerical model as well as heat and moisture supply from the ocean.

Actual Energy Consumption Analysis on Temperature Control Strategies (Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control) of Secondary Side Hot Water of District Heating System (지역난방 2차측 공급수 온도 제어방안(설정온도 제어, 외기온 보상제어, 외기온 예측제어)에 따른 에너지사용량 실증 비교)

  • Cho, Sung-Hwan;Hong, Seong-Ki;Lee, Sang-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.137-145
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side of District Heating System (DHS) with different hot water supply temperature control methods are compared. Three methods are Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Prediction Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side of the system, the results show that Outdoor Temperature Prediction Control method saves more energy. In general, Outdoor Temperature Prediction Control method lowers the supply temperature of hot water, and it reduces standby losses and increases overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, Outdoor Temperature Prediction Control method saves about 7.1% in comparison to Outdoor Temperature Reset Control method and about 15.7% in comparison to Set-point Control method. Also, it is found that at when partial load condition, such as daytime, the fluctuation of hot water supply temperature with Set-point Control is more severe than Outdoor Temperature Prediction Control. Therefore, it proves that Outdoor Temperature Prediction Control is more stable even at the partial load conditions.

Development of a Computer Program for Thermal Sizing of a Copper Bonded Steam Generator (구리밀봉 증기발생기의 열적크기 계산을 위한 프로그램 개발)

  • 김의광;김연식;어재혁;김성오;백병준
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.84-92
    • /
    • 2003
  • A one-dimensional thermal-hydraulic analysis computer program is developed for thermal sizing of a copper bonded steam generator. It is assumed that the conduction heat transfer of copper region between the hot side and the cold side tube is one-dimensional and its thermal resistance is derived as a function of a tube pitch. The flow regions of the water/steam side are divided into four regions: subcooled, saturated, film boiling, and super-heated. The number of tube selected ranges from 250 to 3500 and the pitch to tube diameter (P/D) ratios are 1.4, 1.6 and 1.8 for the parametric study calculation. The calculation results showed that when the number of tube was 2500, the length of the heating tube was about 12 m and the outside diameter of the steam generator was about 3 m. If the P/D ratio increases, the thermal resistance of copper component also increases, however the length of the heating tube is not so much increased.

A Study on Optimum Shape of Shield Gas Nozzle for Bead Shape Control in TIG Welding using Gas Force (Ⅰ) - Design and Performance Analysis of Venturi Nozzle - (TIG용접에서 가스력을 이용한 비드형상제어를 위한 실드가스 노즐의 최적 형상에 관한 연구 (I) - 벤투리노즐의 설계 및 성능분석 -)

  • Ham, Hyo-Sik;Seo, Ji-Seok;Choi, Yoon-Hwan;Lee, Yeon-Won;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.29 no.3
    • /
    • pp.51-57
    • /
    • 2011
  • Bead shape control with gas force process has been developed to overcome the concave back bead in pipe orbital welding. However, It is impossible to make a convex back bead using the existing gas nozzle, because it has high gas-consuming and low gas force. The purpose of this paper, to develop optimum shape of nozzle which to reduce the consumption of gas, maximizing the shield gas force with low cost and high productivity coincide the Green welding. In this paper venturi-type nozzle was designed by using the Venturi meter and compared velocity, pressure, arc shape in the flat position with existing CP-nozzle. As a result, Venturi-type nozzle's maximum velocity and pressure was improved at the same flow rate. Also heat input was increased by the arc contraction in the flat position.

Anaysis of Small-sized Power Connectors for Mobile Device Batteries (모바일기기 배터리용 초소형 파워 커넥터 해석)

  • Lee, Keun-Myoung;Oh, Ung;Yoo, Sung-Kyu;Song, Byeong-Suk
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.101-109
    • /
    • 2015
  • As the number of smartphone users grows, number of applications and the expected overall functionality in a smartphone grow simultaneously. With ever-so increasing expectations comes intense competition to squeeze in myriads of functions in a limited space that is only getting 'slimmer' by the year. In order to achieve this, companies often decrease the size of components in smartphones - battery connectors in particular. While they may fit, smaller battery connectors have their disadvantages due to the heat generated by the high current flow in the circuits. In collaborating with Korea's leading battery connector manufacturers, this research presents current issues and design concepts that should be considered when engineers design power connectors based on their electrical and thermal analysis.

Analysis of Flame Shape in Flare Stack (플레어스택의 화염 형상 분석)

  • Lee, Heon-Seok;Kim, Bum-Su;Jung, Sang-Yong;Yoo, Jin-Hwan;Park, Chul-Hwan;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.49-53
    • /
    • 2009
  • Relief systems can improve the process safety because it has the function for the prevention of overpressure. Flare stacks is necessary to avoid explosion, radiation, or toxicity by waste-gas emitted from relief system. Safe combustion is one of the important factors to improve safety and the quantity and velocity emitted is ruled in the API code 521. Due to the pressure of released gas and mass flow, a flame from flare stack is similar to jet fire. In this study, we have investigated the effect of flame form on complete combustion and heat emission. API code was similar to jet fire model in flame length, the flame had an effect on the ground.

  • PDF

Histone Deacetylase Inhibitor Trichostatin A Enhances Antitumor Effects of Docetaxel or Erlotinib in A549 Cell Line

  • Zhang, Qun-Cheng;Jiang, Shu-Juan;Zhang, Song;Ma, Xiao-Bin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.7
    • /
    • pp.3471-3476
    • /
    • 2012
  • Background and Objective: Histone deacetylase (HDAC) inhibitors represent a promising class of potential anticancer agents for treatment of human malignancies. In this study, we investigated the effect of trichostatin A (TSA), one such HDAC inhibitor, in combination with docetaxel (TXT), a cytotoxic chemotherapy agent or erlotinib, a novel molecular target therapy drug, on lung cancer A549 cells. Methods: A549 cells were treated with TXT, erlotinib alone or in combination with TSA, respectively. Cell viability, apoptosis, and cell cycle distribution were evaluated using MTT (3- (4, 5-dimethylthiazol-2-yl) -2, 5-diphenyltetrazolium bromide) assay, Hochst33258 staining and flow cytometry. Moreover, immunofluorescent staining and Western blot analysis were employed to examine alterations of ${\alpha}$-tubulin, heat shock protein 90 (hsp90), epidermal growth factor receptor (EGFR), and caspase-3 in response to the different exogenous stimuli. Results: Compared with single-agent treatment, co-treatment of A549 cells with TSA/TXT or TSA/erlotinib synergistically inhibited cell proliferation, induced apoptosis, and caused cell cycle delay at the $G_2/M$ transition. Treatment with TSA/TXT or TSA/erlotinib led to a significant increase of cleaved caspase-3 expression, also resulting in elevated acetylation of ${\alpha}$-tubulin or hsp90 and decreased expression of EGFR, which was negatively associated with the level of acetylated hsp90. Conclusions: Synergistic anti-tumor effects are observed between TXT or erlotinib and TSA on lung cancer cells. Such combinations may provide a more effective strategy for treating human lung cancer.

Boundary Element Analysis of Thermal Stress Intensity Factors for Cusp Crack in Transient State (천이상태에 있는 커스프균열에 대한 열응력세기계수의 경계요소 해석)

  • 이강용;홍정균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1700-1710
    • /
    • 1992
  • The boundary element method is applied to determine thermal stress intensity factors for a cusp crack in transient state. In the steady temperature field, numerical values of thermal stress intensity factors for a Grifith crack and a symmetric lip cusp crack in a finite body are in good agreement within .+-. 5% with the previous solutions. In transient state, the numerical values of thermal stress intensity factors for the Griffith crack are also in good agreement with the pervious solutions. In both steady and transient states, those for the symmetric lip cusp crack with the crack surface insulated or fixed to the constant temperature are calculates for various effective crack lengths, configuration parameters and uniform heat flow angles. The variations of the thermal boundary conditions of the crack surface have a effect on stress intensity factors. The signs on the values of thermal stress intensity factors can be changed in time variation.

Experimental Study of a Recuperator with Offset Strip Fins (오프셋 스트립 휜을 가지는 리큐퍼레이터에 대한 실험적 연구)

  • Kim, Taehoon;Do, Kyu Hyung;Han, Yong-Shik;Choi, Byung-Il;Kim, Myungbae
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.72-78
    • /
    • 2015
  • In the present study, a recuperator to improve the thermal efficiency of a micro gas turbine is considered. The counter flow plate-fin heat exchanger with offset strip fins is chosen as the type of the recuperator. From the optimization study as varying design parameters of the recuperator determined from the ideal cycle analysis, the internal structure of the recuperator is determined. The recuperator is made from stainless steel 304. In order to evaluate performance of the recuperator, experimental investigation is performed. The effects of inlet temperature of hot-side of the recuperator on the thermal performance of the recuperator are investigated. As a result, effectiveness of the recuperator obtained from the experiments is well consistent with that obtained from the correlations.

Experimental and Numerical Research on the Airflow Inside Asymmetric Nasal Cavities (비대칭 비강 내 공기유동에 관한 실험 및 수치해석적 연구)

  • Kim, Sung-Kyun;Park, Joon-Hyung;Leim, Huynh Quang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.749-754
    • /
    • 2010
  • Knowledge of the characteristics of airflow in nasal cavities is essential to understand the physiological and pathological aspects of nasal breathing. In our laboratory, a series of experimental investigations on the nasal airflow was conducted; airflow in models of normal and deformed nasal cavities under both constant and periodic flow conditions was studied by PIV. Some of the patients with asymmetric nasal cavities experience pain or discomfort, while other patients with asymmetric nasal cavities do not experience pain. Airflows inside asymmetric nasal cavities with and without obstructions due to a bent nasal septum are investigated both experimentally by PIV and numerically by using the general-purpose FVM code in order to determine the reason for the above-mentioned discrepancy. The comparisons between two cases are tried. Heat and humidity distribution are investigated numerically.