• Title/Summary/Keyword: Heat-Sink

Search Result 563, Processing Time 0.027 seconds

Multi-unit Level 2 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Cho, Jaehyun;Han, Sang Hoon;Kim, Dong-San;Lim, Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1234-1245
    • /
    • 2018
  • The risk of multi-unit nuclear power plants (NPPs) at a site has received considerable critical attention recently. However, current probabilistic safety assessment (PSA) procedures and computer code do not support multi-unit PSA because the traditional PSA structure is mostly used for the quantification of single-unit NPP risk. In this study, the main purpose is to develop a multi-unit Level 2 PSA method and apply it to full-power operating six-unit OPR1000. Multi-unit Level 2 PSA method consists of three steps: (1) development of single-unit Level 2 PSA; (2) extracting the mapping data from plant damage state to source term category; and (3) combining multi-unit Level 1 PSA results and mapping fractions. By applying developed multi-unit Level 2 PSA method into six-unit OPR1000, site containment failure probabilities in case of loss of ultimate heat sink, loss of off-site power, tsunami, and seismic event were quantified.

Analysis on Infrared Stealth Performance of Metal Nano-coating on Radome Surface (레이돔 표면에 금속 나노코팅을 적용한 적외선 저피탐 성능특성 연구)

  • Lee, Yongwoo;Chang, Injoong;Nam, Juyeong;Bae, Hyung Mo;Cho, Hyung Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.251-258
    • /
    • 2022
  • Infrared stealth technology used in aircraft is applied to reduce the infrared signal by controlling surface temperature and emissivity using internal heat sink, low emissivity material or metamaterial. However, there is one part of the aircraft where the use of this technology is limited, and that is the radome. Especially, radome should have transmittance for the specific radio frequency, therefore, common stealth technology such as emissivity control surfaces cannot be applied to radome surface. In this study, we developed metal nano-coating for infrared stealth which is applicable to radome surface. We designed slot-type pattern for frequency selective transmission in X-band, and also controlled thickness of metal nano-coating for long wavelength infrared emissivity control. As a result, our infrared stealth surface for radome has 93.2 % transmittance in X-band and various infrared emissivities from 0.17 to 0.57 according to nano-coatings thickness. Also, we analyzed infrared signature of radome through numerical simulation, and finally reduced contrast radiant intensity by 97.57 % compared to polyurethane surface.

Thermal Conductivity Measurement of Rock Cores from Ulleung Island Using PEDB System at Room Temperature (상온 환경에서 PEDB를 이용한 울릉도 시추코어의 열전도도 예비 측정)

  • Lee, Sang Kyu;Lee, Tae Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.3
    • /
    • pp.121-130
    • /
    • 2016
  • Several factors are discussed that should be considered in measuring thermal conductivity of rock cores with a PEDB (potable electronic divided bar) system, which is relatively accurate and easy to operate, and can measure the thermal conductivity of rock cores for various diameters. Then the system is applied to measure thermal conductivity of 70 rock cores from Ulleung Island. Air temperature affects most on the thermal conductivity measurements, so that it is very important to minimize the temperature change during the measurement. Other factors such as the temperature of heat source, averaging time window on the thermal conductivity measurements do not affect much compared to air temperature. Slightly higher thermal conductivity is measured when using the thermal contact paste between the sample and heat source or heat sink. Especially, rock cores with irregular surface showed bigger difference. Repeatability showed less than ${\pm}0.3%$ for standard samples and less than ${\pm}4%$ for rock samples, respectively, when the room temperature changes within $1^{\circ}C$ during the measurements. Thermal conductivity of the rock cores from Ulleung Island roughly increases as depth increases but does not show any dependency on the rock types.

Performance Analysis on the Multi Stage Reheater Regeneration Cycle for Ocean Geothermal Power Generation (해양지열발전용 다단재열재생사이클 성능해석)

  • Lee, Ho Saeng;Cha, Sang Won;Jung, Young Kwon;Kim, Hyeon Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.2
    • /
    • pp.116-121
    • /
    • 2014
  • In order to study the improvement of the multi stage regeneration cycles, muti-stage processes were applied to the cycles, respectively or together. The kinds of the cycles are multi stage reheater cycle (MS) and multi stage reheater regeneration cycle (MSR). Working fluid used was R134a and R245fa. Temperature of the heat source was $65^{\circ}C$, $75^{\circ}C$, and $85^{\circ}C$, and temperature of the heat sink was $5^{\circ}C$. Optimization simulation was conducted for improving the gross power and efficiency with multi stage reheater regeneration cycle for ocean thermal energy conversion(OTEC) with changing of a heat source, kind of the working fluid, and type of the cycle. Performance analysis of the various components was simulated by using the Aspen HYSYS for analysis of the thermodynamic cycle. R245fa shows better performance than R134a. This paper showed the most suitable working fluid with changing of a heat source and the kinds of working cycle. Compared to each other, MS showed better performance at gross power and MSR showed higher cycle efficiency.

Errors in Net Ecosystem Exchanges of CO2, Water Vapor, and Heat Caused by Storage Fluxes Calculated by Single-level Scalar Measurements Over a Rice Paddy (단일 높이에서 관측된 저장 플럭스를 사용할 때 발생하는 논의 이산화탄소, 수증기, 현열의 순생태계교환량 오차)

  • Moon, Minkyu;Kang, Minseok;Thakuri, Bindu Malla;Lee, Jung-Hoon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.3
    • /
    • pp.227-235
    • /
    • 2015
  • Using eddy covariance method, net ecosystem exchange (NEE) of $CO_2$ ($F_{CO_2}$), $H_2O$ (LE), and sensible heat (H) can be approximated as the sum of eddy flux ($F_c$) and storage flux term ($F_s$). Depending on strength and distribution of sink/source of scalars and magnitude of vertical turbulence mixing, the rates of changes in scalars are different with height. In order to calculate $F_s$ accurately, the differences should be considered using scalar profile measurement. However, most of flux sites for agricultural lands in Asia do not operate profile system and estimate $F_s$ using single-level scalars from eddy covariance system under the assumption that the rates of changes in scalars are constant regardless of the height. In this study, we measured $F_c$ and $F_s$ of $CO_2$, $H_2O$, and air temperature ($T_a$) using eddy covariance and profile system (i.e., the multi-level measurement system in scalars from eddy covariance measurement height to the land surface) at the Chengmicheon farmland site in Korea (CFK) in order to quantify the differences between $F_s$ calculated by single-level measurements ($F_s_{-single}$ i.e., $F_s$ from scalars measured by profile system only at eddy covariance system measurement height) and $F_s$ calculated by profile measurements and verify the errors of NEE caused by $F_s_{-single}$. The rate of change in $CO_2$, $H_2O$, and Ta were varied with height depending on the magnitudes and distribution of sink and source and the stability in the atmospheric boundary layer. Thus, $F_s_{-single}$ underestimated or overestimated $F_s$ (especially 21% underestimation in $F_s$ of $CO_2$ around sunrise and sunset (0430-0800 h and 1630-2000 h)). For $F_{CO_2}$, the errors in $F_s_{-single}$ generated 3% and 2% underestimation of $F_{CO_2}$ during nighttime (2030-0400 h) and around sunrise and sunset, respectively. In the process of nighttime correction and partitioning of $F_{CO_2}$, these differences would cause an underestimation in carbon balance at the rice paddy. In contrast, there were little differences at the errors in LE and H caused by the error in $F_s_{-single}$, irrespective of time.

Visualization and 3D Numerical Analysis of the Circulation Flow of the Neutron Moderator in a Heavy-Water Nuclear Reactor (가압중수형 원자로의 중성자 감속재 순환 유동가시화와 삼차원 전산해석)

  • Eom, Tae-Kwang;Lee, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.189-196
    • /
    • 2012
  • The heavy moderator acts as the ultimate heat-sink in an operating CANDU reactor. HUKINS has been developed to investigate moderator flow patterns. HUKINS consists of a 38.4-mm-thick cylindrical shell with a 0.95 m inner diameter and 88 sus-tubes that produce a total heat of 10 kW. A chemical visualization method was selected to estimate the occurrence of typical moderator flow patterns. Momentum-dominated flow, mixed flow, and buoyancy-dominated flow are detected under conditions of a heat load of 7.7 kW and input mass flow rates of 4, 7, and 11 L/min. The experimental results are similar to the results of a CFD simulation that consisted of approximately 1.9 million grids and was conducted using the k-${\varepsilon}$ turbulence model. Therefore, both the present experiments and simulations using HUKINS, a 1/8-scale model, represent all three important flow patterns expected in the real CANDU6 reference reactor. Thus, it has been demonstrated that HUKINS could be useful in the study of CANDU6 moderator circulation.

Bibliographical study on the Jiu Qi(九氣) shown at Ju Tong Lun(擧痛論) in Shao Wen(素問) Huang Ti Nei Ching(黃帝內經) (${\ll}$소문(素問).거통론(擧痛論)${\gg}$에 나타난 구기(九氣)에 대(對)한 고찰(考察))

  • Kim, Bo-Kyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.11 no.1
    • /
    • pp.145-167
    • /
    • 2000
  • Jiu Qi(九氣) was shown at Ju Tong Lun(擧痛論) in Shao Wen(素問) Huang Ti Nei Ching(黃帝內經), and is nine important factors that affect the function of human body. Jiu Qi concludes endogenous, exogenous, non-endo-exogenous factors. I do the bibliographical study on the Jiu Qi, the results were as follows; 1. The Qi of Jiu Qi has two opposite meanings. one is genuine vital energy(正氣), and the other is the factors causing abnormal state in vital energy. Jiu Qi is nine factors concluding coldness-heat(exogenous factors). six emotional factors(endogenous factor), overworking(non -endo-exogenous factor). 2. Anger may lead to abnormal rising of vital energy. Anger causes Qi of the liver to go perversely upward, and perverted flow of exuberant Qi of the liver lead to dysfunction of the spleen, so resulted in hematemesis, diarrhea, indigestion. 3. Joy can promote the harmony of vital energy and blood, so do the circulation of nutrient and defensive energy in physiological state. But an excessive joy may lead to the sluggishness of vital energy. 4. The lung keeps the pathway of air unconstructed, disseminates vital energy, cleanses the inspired air and keeps vital energy flowing downward. Sorrow affects on the function of the lung and the heart, so could result in obstruction of the circulation of nutrient and defensive energy. An excessive sorrow after stagnation may lead to the consumption of vital energy. 5. Fear makes vital energy and essence of the kidney sink to inward and downside, makes Yang-Qi can't go upward, so causes obstruction of triple wanner. An excessive fear can obstructs the ascending of Yang-Qi, so may lead to the abnormal falling of vital energy. 6. Coldness makes the sweat pore be contracted, so obstructs the circulation of triple warmer, causes sluggishness of defensive energy or Qi of the internal organ. 7. Heat makes the sweat pore be open, much amount of sweat is excreted with Yang-Qi, defensive energy, vital energy. Heat may consume vital energy. 8. Sudden fright affects on spirits of the heart and liver, causes disorder of the mental faculties and separation of blood and vital energy. Fright may lead to disorder of Qi. 9. Overwork concludes overfatigue and exhaustion caused by intemperance in sexual life. Overwork renders vital energy consumed, and hence results in lassitude and listlessness. 10. Thinking affects on the function of the heart and the spleen. Over thinking may lead to depression of vital energy. Through the bibliographical study on Jiu Qi, I got smallest amount of it, and this must be more investigated correlating with clinical study.

  • PDF

A Study about medical doctors of the school of Seowon (서원학파(西源學派) 의가(醫家)에 관(關)한 연구(硏究))

  • Yoon, Chang-Yeol
    • Journal of Korean Medical classics
    • /
    • v.26 no.3
    • /
    • pp.1-9
    • /
    • 2013
  • Objective : In South Song era, Choe Ga-eon(崔嘉彦) built Seowonam(西源庵), lived as a hermit and communicated with Juja(朱子) in LuShan(廬山), JiangXi province(江西省), JiuJiang city(九江市). Maekgyeol(脈訣) written by him significantly influenced the forthcoming medical doctors, who took over his studies and were called the school of Seowon. Little information about his life and his successors encouraged this study. Method : The core contents of Maekgyeol(脈訣), his life based on Waryongamgi(臥龍庵記) and Seowongamgi(西源庵記) written by Juja(朱子) and his successors on the basis of various medical books were investigated. Result : The Seowonam(西源庵) is located at the entrance of xiufeng Scenic spot(秀峰景區) which is 6km west from center of Xingzi county(星子縣), JiangXi province(江西省), JiuJiang city(九江市). The points of Maekgyeol(脈訣) are inferring the symptom of wind, energy, cold and heat by categorizing seven exterior and eight interior pulse into four pulses of float, sink, slow and quick and diagnosing a disease of three warmer and the five viscera and the six entrails by subordinating four pulses to Chon, Gwan, and Cheok(寸關尺). By writing the book of Sawonron(四原論) he clarified the clinical point, pulse, disease, symptom, treatment with learning the cause of a disease through pulse, understanding the symptom through a disease, and giving a remedy through a symptom. Then he communicated with Juja(朱子) assigned to NanKangJun(南康軍) as a ruler. He helped Juja(朱子) to build Waryongam(臥龍庵) and Juja(朱子) wrote Seowonamgi(西源庵記) for him. Conclusion : The members of medical doctors of the school of Seowon were Choe Ga-eon(崔嘉彦) and his follower Yu Gae(劉開), Yugae's disciple Eom Yong-hwa(嚴用和) and Ju Jong-yang(朱宗陽) and Ju Jong-yang's disciple Jang Do-jung(張道中). They, who were famous for pulse, had contributed to advancing study of pulses in the field of oriental medicine.

Effects of Fe, Mn Contents on the Al Alloys and STD61 Steel Die Soldering (Al 합금과 STD61강의 소착에 미치는 첨가원소 Fe, Mn의 영향)

  • Kim, Yu-Mi;Hong, Sung-Kil;Choi, Se-Weon;Kim, Young-Chan;Kang, Chang-Seog
    • Korean Journal of Materials Research
    • /
    • v.22 no.4
    • /
    • pp.169-173
    • /
    • 2012
  • Recently, various attempts to produce a heat sink made of Al 6xxx alloys have been carried out using die-casting. In order to apply die-casting, the Al alloys should be verified for die-soldering ability with die steel. It is generally well known that both Fe and Mn contents have effects on decreasing die soldering, especially with aluminum alloys containing substantial amounts of Si. However, die soldering has not been widely studied for the low Si aluminum (1.0~2.0wt%) alloys. Therefore, in this study, an investigation was performed to consider how the soldering phenomena were affected by Fe and Mn contents in low Si aluminum alloys. Each aluminum alloy was melted and held at $680^{\circ}C$. Then, STD61 substrate was dipped for 2 hr in the melt. The specimens, which were air cooled, were observed using a scanning electron microscope and were line analyzed by an electron probe micro analyzer. The SEM results of the dipping soldering test showed an Al-Fe inter-metallic layer in the microstructure. With increasing Fe content up to 0.35%, the Al-Fe inter-metallic layer became thicker. In Al-1.0%Si alloy, the additional content of Mn also increased the thickness of the inter-metallic layer compared to that in the alloy without Mn. In addition, EPMA analysis showed that Al-Fe inter-metallic compounds such as $Al_2Fe$, $Al_3Fe$, and $Al_5Fe_2$ formed in the die soldering layers.

Transient Performance Analysis of the Reactor Pool in KALIMER-600 with an Inertia Moment of a Pump Flywheel (펌프 회전차의 관성모멘트 제공에 의한 KALIMER-600 원자로 풀 과도 성능 분석)

  • Han, Ji-Woong;Eoh, Jae-Hyuk;Lee, Tea-Ho;Kim, Seong-O
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.418-426
    • /
    • 2009
  • The effect of an inertia moment of a pump flywheel on the thermal-hydraulic behaviors of the KALIMER-600(Korea Advanced LIquid MEtal Reactor) reactor pool during an early-phase of a loss of normal heat sink accident was investigated. The thermal-hydraulic analyses for a steady and a transient state were made by using the COMMIX-1AR/P code. In the present analysis a quarter of the reactor geometry was modeled in a cylindrical coordinate system, which includes a quarter of a reactor core and a UIS, a half of a DHX and a pump and a full IHX. In order to evaluate the effects of an inertia moment of the pump flywheel, a coastdown flow whose flow halving time amounts to 3.69 seconds was supplied to a natural circulation flow in the reactor vessel. Thermal-hydraulic behaviors in the reactor vessel were compared to those without the flywheel equipment. The numerical results showed a good agreement with the design values in a steady state. It was found that the inertia moment contributes to an increase in the circulation flow rate during the first 40 seconds, however to a decrease of it there after. It was also found that the flow stagnant region induced by a core exit overcooling decelerated the flow rate. The appearance of the first-peak temperature was delayed by the flow coastdown during the initial stages after a reactor trip.