• Title/Summary/Keyword: Heat-Bridge

Search Result 181, Processing Time 0.024 seconds

New Key-Segment Closing Method Using Thermal Effect for Partially Earth-Anchored Cable-Stayed Bridges (온도 효과를 이용한 일부 타정식 사장교의 키-세그먼트 폐합법)

  • Won, Jeong Hun;Yoon, Ji Hyun;Cho, Kwang Il;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.121-129
    • /
    • 2008
  • study proposes a new key-segment closing method using thermal effect as a substitute to the process of set-back and reset-back for the FCM construction of a partially earth-anchored cable-stayed bridge. The proposed method is to artificially heat up the inside of girders located in the main span before closing the key-segment in a cantilever state. Then, the heat is removed after finishing the closure in a continuous bridge state. Using the changes in boundary conditions and structural systems, the proposed method can generate new member forces that reflect the advantage of the partially earth-anchored cable system. From the construction sequence analysis, it is found that the proposed method increases the efficiency of a partially earth-anchored cable-stayed bridge by reducing the compressive axial forces on the girders.

The Prediction of Temperature in Composite Box Girder Bridges (합성 박스형 교량의 온도 예측)

  • Chang, Sung Pil;Im, Chang Kyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.431-440
    • /
    • 1997
  • The paper describes a theoretical model for the prediction of bridge temperatures from meteorological data measured at bridge site and local meteorological center together with existing finite element heat transfer theory and solar radiation transfer theory to determine the time dependent temperature distribution of bridge. In this analytical model, the most adequate equation for the calculation of solar radiation on the bridge surface, which is dominant in day time is described based on the results of several experimental studies for the solar energy. The validity of this model is tested against field data obtained from long term experimental program on Sadang Viaduct in Seoul. Also, this paper describes the linear correlation between design variables and meteorological data to establish analytical criteria for the prediction of the average temperature, which are responsible for the longitudinal deformation of the bridges and of the vertical differential temperature profiles. which are responsible for the bending deformations from the long term experimental results.

  • PDF

Field Application of Low Heat Concrete Using Strontium Hydroxide Based Latent Heat Material (스트론튬계 잠열재를 사용한 저발열 콘크리트의 현장적용 평가)

  • Khil, Bae Su;Yun, Hyun Do;Jeong, Ok Ran
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.218-226
    • /
    • 2011
  • Low heat concrete using strontium hydroxide based latent heat material was manufactured in ready-mixed concrete batcher plant and its fundamental properties were tested. As a result of B/P test, its applicability to the construction site was verified. After B/P test, low heat concrete using strontium hydroxide based latent heat material was applied to the real construction site of bridge footing. Through the analysis and the actual measurement of the hydration heat of the concrete footing, the reduction effect of hydration heat and thermal crack was confirmed.

Weld Defect Formation Phenomena during High Frequency Electric Resistance Welding

  • Choi, Jae-Ho;Chang, Young-Seup;Kim, Yong-Seog
    • Journal of Welding and Joining
    • /
    • v.19 no.3
    • /
    • pp.267-273
    • /
    • 2001
  • In this study, welding phenomena involved in formation of penetrators during high frequency electric resistance welding were investigated. High speed cinematography of the process revealer that a molten bridge between neighboring skelp edges forms at apex point and travels along narrow gap toward to welding point at a speed ranging from 100 to 400 m/min. The bridge while moving along the narrow gap swept away oxide containing molten metal from the gap, providing oxide-free surface for a forge-welding at upsetting stand frequency of the budge formation, travel distance and speed of the bridge were affected by the heat input rate into strip. The travel distance and its standard deviation were found to have a strong relationship with the weld defect density. Based on the observation, a new mechanism of the penetrator formation during HF ERW process is proposed.

  • PDF

An Analysis of Optimized Position of the Fiber Optic Sensor Istalled near the Bridge Wire of Electro-explosive Device (전기기폭장치의 발열선에 설치되는 광섬유 센서의 최적위치 분석)

  • 김응조;윤기은;최태인;윤태훈;김재창
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1111-1117
    • /
    • 1999
  • In order to measure the temperature of bridge wire, the explosive material is removed from EED and a fiber optic temperature sensor is installed near the bridge wire. Using the heat transfer theory, the optimum position of the fiber optic sensor in the EED is determined and the temperature-distance equation is derived from test result. The measuring technique can be utilized to the real electromagnetic radiation hazard test.

  • PDF

ZVS Resonant Energy Unbalance Problem & Solution of ZVS Full-bridge Converter (ZVS Full-bridge 컨버터의 ZVS 공진 에너지 불평형 문제와 해결 방법)

  • Lee Dong-Youn;Lee Il-Oun;Cho Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.364-367
    • /
    • 2001
  • ZVS Full-bridge converter is widely used in medium power level(1-3kW). ZVS can be designed within a limited load range and ZVS failure at light load condition is assumed to be acceptable within the given efficiency and thermal constraints. However, unbalanced ZVS resonant energy caused by dc blocking capacitor may alleviate the switching loss problem at light load condition. ZVS resonant energy is unbalanced by do blocking capacitor. This problem causes loss and heat concentration of a switch leg, In this paper, this problem is analyzed, and a novel control method is proposed to solve the problem.

  • PDF

Field Measurement of Hydration Heat and Field Aaaplication of Pipe Cooling System (수화열 계측 및 파이프쿨링 시공 사례)

  • 최계식;양주경;최영돈;최고일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.381-386
    • /
    • 1994
  • Recently, the design and construction of massive concrete structures are increased. But, the temperature rise within a large concrete mass make the construction of massive concrete structures be very difficult. Therefore, in Seohae Grand Bridge Project, the field measurement of hydration heat for the massive concrete footings(11$\times$22$\times$4m) was carried out. It was shown to be possible to construct the massive concrete footing successfully by application of pipe cooling system. And the measurement results showed that standard code for concrete practice was very conservative.

  • PDF

An Experimental Study on the Thermal Performance of a Concentric Annular Heat Pipe

  • Boo Joon Hong;Park Soo Yong;Kim Do Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1036-1043
    • /
    • 2005
  • Concentric annular heat pipes (CAHP) were fabricated and tested to investigate their thermal characteristics. The CAHPs were 25.4 mm in outer diameter and 200 mm in length. The inner surface of the heat pipes was covered with screen mesh wicks and they were connected by four bridge wicks to provide liquid return path. Three different heat pipes were fabricated to observe the effect of change in diameter ratios between 2.31 and 4.23 while using the same outer tube dimensions. The major concern of this study was the transient response as well as isothermal characteristics of the heat pipe outer surface, considering the application as uniform heating device. A better performance was achieved as the diameter ratio increased. For the thermal load of 180 W, the maximum temperature difference on the outer surface in the axial direction of CAHP was $2.3^{\circ}C$ while that of the copper block of the same outer dimension was $5.9^{\circ}C.$ The minimum thermal resistance of the CAHP was measured to be $0.004^{\circ}C/W.$ In regard to the transient response during start-up, the heat pipe showed almost no time lag to the heat source, while the copper block of the same outer dimensions exhibited about 25 min time lag.

Common-Mode Current Cancellation Scheme of Half-Bridge Switch-Mode Converter for DC Motor Drive

  • Srisawang, Arnon;Panaudomsup, Sumit;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1876-1879
    • /
    • 2003
  • Due to the conventional half-bridge switch-mode converters for dc motor drive have been usually using unbalanced circuit topologies which generate common-mode currents through parasitic capacitors distributed between the ground and the dc motor frame such as the heat-sink of switching devices or the frame of the dc motor. This paper describes methods that cancel common-mode current generated in half-bridge switch-mode converters by using circuit balancing technique. The circuit balancing is to make the noise pickup or occurring in both conductor lines, signal and return pathes, is equal in amplitude and opposite in phase so that it will be canceled out in the ground plane. The common-mode current cancellation in the proposed converter is confirmed by experimental results.

  • PDF

Descriptive study on the procedure of dental prostheses at the dental laboratory in Seoul (치과기공소의 보철 기공물 제작 과정에 사용되는 재료 및 방법에 관한 실태조사 연구)

  • Hwang, Kyung-Sook
    • Journal of Technologic Dentistry
    • /
    • v.16 no.1
    • /
    • pp.57-77
    • /
    • 1994
  • The purpose of this study is to investigate the extent to which dental laboratories use proper materials, procedures, devices, and equipments to fabricate crown & bridge, PFM(Porcelain Fused to Metal) crown & bridge, partial denture, complete denture, and other prosteses. 100 laboratories in Seoul were selected for this investigation. Questionnaires were constructed focusing on five topocs:crown & bridge, PFM crown & bridge, partial denture, complete denture, and other prostheses. The results from this survey were as follows : 1. Most dental laboratories used old, inexpensive, and familiar materials rather than newly developed ones. 2. Most of the dental technicians did not stick to the standard procedures of handling materials, but to their own experiences. 3. Newly developed equipments to fabricate dental prostheses were possessed by nearly 30% dental laboratories. 4. About 80% of dental laboratories were using the procedures they had learned in the school : die trimming for accurate crown margin and softening heat treatment after RPD gold casting. But less than 30% of laboratories were shown to follow the boxing procedure to produce master cast and laboratory remounting in the process of complete denture. The findings show that dental laboratory procedures to fabricate dental prostheses are incomplete and inaccurate in some instances. So, further studies are neededs to clarify the causes of some inaccurate procedures, the better and more equipments should be supplied to produce the more accurate dental posthesis, and more efforts at enancing the appropriate use of dental materials and procedures should be made.

  • PDF