• 제목/요약/키워드: Heat transfer plate

검색결과 822건 처리시간 0.03초

콜로게이트 열교환기와 평판형 열교환기의 열전달특성에 관한 실험적 연구 (Experimental Study on the Heat Transfer Characteristics in Corrugated and Flat Plate Type Heat Exchanger)

  • 박정훈;정용기;전충환;장영준;임혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.37-42
    • /
    • 2003
  • An experiment was performed to study heat transfer characteristics between corrugated heat exchanger and flat plate type one. While heat capacity(13.86kW) was provided constantly and the flow speed was varied from 2.8 to 17.9m/s, The temperature and the pressure drop were measured. Furthermore, Heat transfer coefficient, Colburn factor and Nusselt number were calculated using them. With increase of the flow speed for both exchangers, the coefficient and the pressure drop increased, but Colburn factor decreased. The coefficient, pressure drop and Colburn factor of the corrugated type were all higher than those of the flat one, which is due to the flow interruption with recirculation and reattachment of the corrugated type. The empirical correlations of Nusselt number were suggested for the tested two heat exchangers.

  • PDF

과도열전도를 갖는 평판핀에서의 강제대류 열전달 (Forced Convection Heat Transfer in a Plate Fin With Transient Heat Conduction)

  • 조진호;이상균
    • 오토저널
    • /
    • 제9권4호
    • /
    • pp.69-76
    • /
    • 1987
  • A conjugate conduction-convection analysis has been made for a plate fin which exchanges heat with its fluid environment by forced convection. The analysis is based on a one- dimensional model for the plate fin whereby the transient heat conduction equation for the fin is solved simultaneously with the conservation equations for mass, momentum, and energy in the fluid boundary layer adjacent to the fin. The forced convection heat transfer coefficient is not specified in advance but is one the results of the numerical solutions. Numerical results of the overall heat transfer rate, the local heat transfer coefficient, the local heat flux, the fin efficiency and the fin surface temperature distribution for Pr=0.7 are presented for a wide range of operating conditions.

  • PDF

2차원(次元) 충돌분류(衝突噴流)의 열전달(熱傳達) 증진(增進)에 관(關)한 실험적(實驗的) 연구(硏究) (사각(四角) Rib폭(幅)의 효과(效果)) (Augmentation of Heat Transfer by two Dimensional Impinging Air Jet (Effect of Square Rib Width))

  • 이용화;이관석;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.350-356
    • /
    • 1988
  • The impinging air jet system is still being used in the various fields with its inherent merits, that is, the easiness in engineering application and high heat transfer coefficients at stagnation point. The purpose of this study is augmentation of heat transfer without additional power in the rectangular air jet which impinges vertically to the heating surface. As a method of passive heat transfer augmentation in a two-Dimensional impinging jet, the transverse-repeated surface roughness of square cross-section is used. This paper deals with the experimental study on the characteristics of heat transfer at the x-direction in between nozzle exit and heating surface of flat plate, and that of ribbed plate. And this study also investigates the effect of square rib widths. The integral average heat transfer coefficient of ribbed plate is about 2.2 times larger than that of flat plate.

  • PDF

용접식 판형 열교환기의 성능에 관한 실험적 연구 (Experimental study on the performance of a brazed plate heat exchanger)

  • 김종하;윤재호;권오경;김종훈;류해성;이창식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.477-482
    • /
    • 2001
  • An experimental study on the performance evaluation of a brazed plate heat-exchanger with 10RT of normal cooling capacity has been carried out. In the present study, a brazed type plate heat exchanger was tested at a chevron angle $25^{\circ}$ with refrigerant R-22. Mass flux was ranged from $23\;to\;58kg/m^{2}s$ in condensation, and from $22\;to\;53kg/m^{2}s$ in evaporation. The heat transfer coefficient and pressure drop increased with the mass flux increases. The water side pressure drop increased with the cooling water flow rate and chilled water flow rate increases, while mass flux has little affect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

  • PDF

발포알루미늄 다공핀의 열유동특성 (Flow and Heat Transfer Characteristics of Aluminum Foam Porous Fins)

  • 김서영;백진욱;강병하
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.511-518
    • /
    • 2000
  • The present experimental study investigates the impact of porous fins on the pressure drop and heat transfer characteristics in plate-fin heat exchangers. Systematic experiments have been carried out in a simplified model of a plate-porous fin heat exchanger at a controlled test environment. Comparison of performance between the porous fins and the conventional louvered fins has been made. The experimental results indicate that friction and heat transfer rate are significantly affected by permeability as well as porosity of the porous fin. The porous fins used in the present study show a similar air-side performance to the louvered fin. The correlations of friction and modified j-factor are also given for the design of the plate-porous fin heat exchanger.

  • PDF

용접식 판형 열교환기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of a Brazed Plate Heat Exchanger)

  • 김종하;권오경;윤재호;이창식
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.83-90
    • /
    • 2002
  • An experimental study on the performance evaluation of a brazed plate heat exchanger with 10USRT of normal cooling capacity has been carried out. In the present study, a brazed plate heat exchanger was tested at a chevron angle $25^{\circ}$with refrigerant R-22. Refrigerant mass flux was ranged from 23 to 58 kg/$m^2$s in condensation, and from 22 to 53 kg/$m^2$s in evaporation. The heat transfer coefficients and pressure drops are increased as the mass flux increases. The water side pressure drop is increased as the cooling water flow rate and chilled water flow rate increase, while mass flux has little effect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

루우버핀 열교환기의 핀피치가 공기측 열전달에 미치는 영향 (Effect of Fin Pitch on Air Side Heat Transfer in Louvered-Fin Heat Exchanger)

  • 장봉주;김선정
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.31-38
    • /
    • 2000
  • In order to study on influence of fin pitch and shape of heat exchanger on the elevation of heat transfer efficiency, we make models of louvered fin type heat exchanger which was given a transformation of fin pitch in louvered fin type heat exchanger which are of en used now. And the influence of fin pitch on pressure drop and characteristics of heat transfer was experimented and analysed when air velocity and fin pitch was a variable. The results of experiment shows below. Pressure drop shows larger in louvered fin type heat exchanger than in plate fin type heat exchanger, size of pressure drop shows like this order that fin space is 4mm, 5mm, 6mm. Mean heat transfer coefficient shows higher in louvered fin type heat exchanger than in plate fin type heat exchanger, size of mean heat transfer coefficient by fin space shows same in both case in louvered fin type heat exchanger and plate fin type like this order that fin space is 4mm, 5mm, 6mm.

  • PDF

비대칭 엇갈림 배열로 구성된 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 특성 해석 (Analysis of Convective Heat Transfer Characteristics for the Compact Heat Exchanger with Flat Tubes and Plate Fins Having a Non-symmetric Staggered Arrangements)

  • 모정하;이상호
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.318-325
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchanger with flat tubes and continuous plate fins having a symmetric and non-symm etric staggered arrangements. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous experimental results. In order to investigate the flow and heat transfer features by periodic boundary conditions, the three blocks were used. Predicted heat transfer coefficients between the three blocks are similar while there are relatively differences, compared with the experimental data. From the calculated results a correlation for Colburn j factor in the compact heat exchanger system is suggested. The predicted results in this study can be applied to the optimal design of air conditioning system.

원형관-평판휜 형상의 밀집형 열교환기 내 공기 측대류열전달특성에 대한 수치해석 (Numerical Analysis for the Air-Side Convective Heat Transfer Characteristics in a Compact Heat Exchanger with Circular Tubes and Continuous Plate Fins)

  • 모정하;이상호
    • 대한기계학회논문집B
    • /
    • 제31권12호
    • /
    • pp.994-1001
    • /
    • 2007
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in a compact heat exchanger with circular tubes and continuous plate fins. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous experimental correlations. Three models of standard and RNG $k-{\varepsilon}$, and Reynolds stress are applied for turbulence model applicability. Predicted heat transfer coefficient from the models of standard and RNG $k-{\varepsilon}$ are very close to those of the heat transfer correlations while there are relatively large difference, more than 17 percentage in the result from the Reynolds stress model. From the calculated results a correlation for Colburn j factor in the compact heat exchanger system is suggested.

연소실 냉각을 위한 충돌제트/유출냉각기법에서 유출판에서의 열전달특성 (Heat Transfer Characteristics on Effusion Plate in Impingement/Effusion Cooling for Combustor)

  • 이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.435-442
    • /
    • 2000
  • The present study is conducted to investigate the local heat/mass transfer characteristics for flow through perforated plates. A naphthalene sublimation method is employed to determine the local heat/mass transfer coefficients on the effusion plate. Two parallel perforated plates are arranged for the two different ways: staggered and shifted in one direction. The experiments are conducted for hole pitch-to-diameter ratios of 6.0, for gap distance between the perforated plates of 0.33 to 10 hole diameters, and for Reynolds numbers of 5,000 to 12,000. The result shows that the high transfer region is formed at stagnation region and at the mid-line of the adjacent impinging jets due to secondary vortices and flow acceleration to the effusion hole. For flows through the perforated plates, the mass transfer rates on the surface of the effusion plate are about six to ten times higher than for effusion cooling alone (single perforated plate). More uniform and higher heat/mass transfer characteristic is obtained in overall region with small gap between two perforated plates.