• 제목/요약/키워드: Heat radiation efficiency

검색결과 160건 처리시간 0.031초

200kW 탑형 태양열발전시스템에서 사용되는 Heliostat의 집열특성 분석 (Analysis of Energy Concentration Characteristics of Heliostat used in 200kW Tower Type Solar Thermal Power Plant)

  • 박영칠
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.80-88
    • /
    • 2011
  • Heliostat in the tower type solar thermal power plant is a sun tracking mirror system to reflect the solar energy to the receiver and the optical performance of it affects to the efficiency of whole power plant most significantly. Thus a solid understanding of heliostat's energy concentration characteristics is the most important step in designing of the heliostat field and the whole power plant. The work presented here is the analysis of energy concentration characteristics of heliostat used in 200kW solar thermal power plant, where the receiver located at 43m high in tower has $2{\times}2$m rectangular shape. The heliostat reflective surface is formed by 4 of $1{\times}1$m flat plate mirror facet and the mirror facet is mounted on the spherical frame. The direct normal incident radiation models in vernal equinox, summer solstice, autumnal equinox and winter solstice are first derived from the actually measured data. Then the intercept ratio, heat flux distribution and total energy collected at the receiver for the heliostats located in the various places of the heliostat field are investigated. Finally the effect of mirror facet installation error on the optical performance of the heliostat is analyzed.

Analysis of Diesel Combustion Flames with Highly Oxygenated Fuels

  • Kim Bong-Seock;Ogawa Hideyuki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.662-670
    • /
    • 2005
  • With highly oxygenated fuels the smoke emissions decreased sharply and linearly with increases in the fuel oxygen content and entirely disappeared at an oxygen content of $38wt-\%$ even at stoichiometric mixture conditions The NOx also decreased monotonically with increases in oxygen content. and thermal efficiency slightly improved because of a reduction in cooling loss and improvement in the degree of constant volume combustion. The mechanisms of the significant reductions in emissions and improvement in engine performance were analyzed with a bottom view type DI diesel engine. Together with direct flame images, flame images were taken through an optical fetter passing only two wavelengths for use in 2-D two-color analysis. The results showed that luminous flame decreased significantly with increases in oxygen content and was not detected for neat dimethoxy methane(DMM). The decrease in flame luminosity with highly oxygenated fuels corresponds with decreases in soot and cooling losses, including those due to heat radiation. The 2-D two-color flame analysis indicated that the high temperature flame and high KL factor areas apparently decreased with increasing fuel oxygen content. These results correspond strongly with decreases in NOx. smoke. and cooling loss with increases in oxygen content.

수치모델을 이용한 고온 태양열 집열기의 열성능 분석 (Characteristic of a Spiral type Receiver for a Dish type solar thermal system using a Numerical model)

  • 김태준;김재익;이진규;이주한;서태범
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.786-791
    • /
    • 2009
  • This study focus on verification of the thermal efficiency of volumetric air receiver with $5kW_{th}$ Dish-type solar thermal system for high temperature uses by using numerical analysis compare with experimental data including shape change of absorber, direction of inlet and outlet. Porous material for radiation-thermal conversion used in former researches are substituted with the stainless steel wall installed along the spiral shaped flow path. Temperature variation and the flow change at the inside of the absorber has been analyzed by Star-ccm+ Version 3.02. Using the numerical model, the heat transfer characteristics of spiral type receiver for dish-type solar thermal systems are known and the thermal performance of the receiver can be estimated.

  • PDF

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF

한국형 달 탐사용 원자력전지의 열제어 구조 연구 (Study on the Thermal Design of Nuclear Battery for Lunar Mission)

  • 홍진태;손광재;김종범;박종한;안동규;양동열
    • 한국정밀공학회지
    • /
    • 제33권4호
    • /
    • pp.271-277
    • /
    • 2016
  • For a stable electric power supply in the space, nuclear batteries have been used as the main power source in a spacecraft owing to their long lifetime and high reliability. In accordance with the plan for lunar mission in Korea, nuclear batteries will supply electricity to the rover that needs to be developed. According to the information about the estimated payload, Korea Atomic Energy Research Institute started with the conceptual design based on the previous studies in USA and Russia. Because a nuclear battery converts the decay heat of the radioisotope into electricity, thermal design, radiation shield, and shock protection need to be considered. In this study, two types of nuclear batteries, radial type and axial type, were designed according to the alignment of the thermoelectric module. Heat transfer analyses were performed to compare their thermoelectric efficiency, and test mockups were fabricated to evaluate their performances.

HPT 방식의 온열침대 디자인 개발에 관한 연구 (A Study on Thermo-Bed Design Development of HPT System)

  • 이봉규
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.72-81
    • /
    • 2011
  • These days, beds have been developed not as furniture to sleep in but Healthcare Furniture. The function of heating, non-electronic-waves and far-infrared rays have been added. Also, eco-friendly materials such as stone, mud, rubber and wood are combined to them together with the radiation-heating method using heat conduction through electronic coil and hot water circulation. Modern people suffer from stress and fatigue. The hot issue is "health." Focused on the health, the development of design for beds considering the influence electronic waves, anions, deep sleep and the density of toxic materials have on human bodies has become urgent. In this study, the trend, specification and efficiency of the functional health-related electronic coil technology are analyzed. Through the analysis, the environmental standards are set. According to them, technology, eco-friendly materials and additional functions for the development of the design are considered. Also, the government is promoting the IEC international standardization for the Korean traditional floor heating style beds. In preparation for that, we adopted new HPT method technology. It enables non-electronic-waves, low electricity and stable temperature maintenance control for the warm top and the cool bottom. Also, the head boards and the frames of the beds can be separated. Through this separation, the beds can be easily moved or installed. Eco-friendly materials such as Hinoki cypress wood and red clay and the existing tables function are combined to the head boards so they can be used as drawers and display shelves. If they are used as separate items, they can be used as covers. This is how we suggest the design for the heating beds.

  • PDF

함정용 LED 투광등 설계 및 제작 (Design and Fabrication of a LED Floodlight for Naval Vessels)

  • 김세진;길경석;김동건;김일권;송동영
    • 한국전기전자재료학회논문지
    • /
    • 제26권10호
    • /
    • pp.771-777
    • /
    • 2013
  • This paper dealt with the development of a LED floodlight for naval vessels to replace the conventional floodlight using an incandescent and a halogen lamp. We found a technical solution for current problems of conventional lights and also improved optical characteristics by developing a LED floodlight which has a typical long-lived light source with high efficiency. To satisfy the requirements specified in Korea Standard Vessels (KS V), the optical structure was designed with selected LED package and lens. A LED module was composed of 10 LEDs in series for stable luminous output, and an aluminium heat sink was adopted for effective heat-radiation design. The LED floodlight was fabricated as a module type so that it can easily replace the conventional light source. The power consumption of the prototype floodlight was only a tenth of a conventional one with the same optical performance. Also, a test showed the floodlight satisfied the electrical, optical and environmental requirements of the standards.

입자 가속기용 수냉식 고전력 증폭기 구현 (Implementation of An Water-Cooled High Power Amplifier for Particle Accelerator)

  • 윤영철;김영
    • 한국항행학회논문지
    • /
    • 제21권1호
    • /
    • pp.66-71
    • /
    • 2017
  • 본 논문은 입자 가속기에 이용되는 165 MHz, 5 kW 고전력 증폭기의 제작에 대한 내용을 서술하였다. 이 고전력 증폭기 구성은 주 증폭기를 구동할 수 있는 드라이브 증폭기 모듈, 16개의 600 W 클래스 AB 푸쉬풀 증폭기 모듈 그리고 이 모듈 출력을 분배 또는 결합하기 위해 집중소자 LC로 구현한 입출력의 윌킨슨 결합기로 구성되어 있다. 그리고 정상적인 출력과 부하에서 반사되는 전력을 감시하여 증폭기를 보호하기 위한 방향성 결합기가 구성되어있으며, 600 W 주 증폭기는 입력전원에 의해서 발생되는 열을 방출시키기 위해서 방열판 밑에 물을 통과시키는 관을 넣어 방열하는 워터 쿨링 방법을 사용하였다. 여기서 구현된 증폭기는 중심주파수 165 MHz에서 포화 전력레벨이 5.0 kW 출력레벨에서 62.5 %의 효율을 얻었다.

대형 코어 폴리머 광도파로를 이용한 가변 광감쇠기 설계 (Design of Variable Optical Attenuators Incorporating Large Core Polymer Waveguides)

  • 조수홍;오민철
    • 한국광학회지
    • /
    • 제16권3호
    • /
    • pp.254-260
    • /
    • 2005
  • 높은 재현성과 함께 효율적인 수동 정렬을 위하여 제안된 대형코어 단일모드 폴리머 광도파로를 이용하여 제작 가능한 폴리머 광도파로 소자인 가변 광감쇠기를 제안하고 삼차원 빔전파 방법을 이용하여 소자의 동작 특성을 파악하고 최적 구조를 설계하였다. 소자의 표면에 집적된 박막 전극 히터에서 발생하는 열로 인해 폴리머 광도파로에서 발생하는 굴절률 분포 변화를 수치해석적으로 구하였으며 이 결과를 이용하여 삼차원 빔전파 해석을 수행하였다. 대형코어 광도파로가 가지는 작은 굴절률 대비로 인해 효과적인 광감쇠 현상을 작은 온도 변화로부터 얻을 수 있음을 확인하였다. 일반 광도파로 VOA에서 섭씨 150도 이상의 온도 변화가 필요한 반면 대형 코아 광도파로 VOA는 섭씨 70도 정도의 온도 변화 만으로도 20 dB 이상의 감쇠를 얻을 수 있었다. 대형코아 광도파로가 가지는 장점인 높은 정렬오차 허용범위와 더불어 낮은 구동전압으로 동작하는 장점을 함께 가지는 가변 광감쇠기 설계를 완성하였다.

Effect of multiple-failure events on accident management strategy for CANDU-6 reactors

  • YU, Seon Oh;KIM, Manwoong
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3236-3246
    • /
    • 2021
  • Lessons learned from the Fukushima Daiichi nuclear power plant accident directed that multiple failures should be considered more seriously rather than single failure in the licensing bases and safety cases because attempts to take accident management measures could be unsuccessful under the high radiation environment aggravated by multiple failures, such as complete loss of electric power, uncontrollable loss of coolant inventory, failure of essential safety function recovery. In the case of the complete loss of electric power called station blackout (SBO), if there is no mitigation action for recovering safety functions, the reactor core would be overheated, and severe fuel damage could be anticipated due to the failure of the active heat sink. In such a transient condition at CANDU-6 plants, the seal failure of the primary heat transport (PHT) pumps can facilitate a consequent increase in the fuel sheath temperature and eventually lead to degradation of the fuel integrity. Therefore, it is necessary to specify the regulatory guidelines for multiple failures on a licensing basis so that licensees should prepare the accident management measures to prevent or mitigate accident conditions. In order to explore the efficiency of implementing accident management strategies for CANDU-6 plants, this study proposed a realistic accident analysis approach on the SBO transient with multiple-failure sequences such as seal failure of PHT pumps without operator's recovery actions. In this regard, a comparative study for two PHT pump seal failure modes with and without coolant seal leakage was conducted using a best-estimate code to precisely investigate the behaviors of thermal-hydraulic parameters during transient conditions. Moreover, a sensitivity analysis for different PHT pump seal leakage rates was also carried out to examine the effect of leakage rate on the system responses. This study is expected to provide the technical bases to the accident management strategy for unmitigated transient conditions with multiple failures.