• Title/Summary/Keyword: Heat pump system simulation

Search Result 253, Processing Time 0.022 seconds

A Characteristics Simulation of Heat Pump System for Sewage Water as a Heat Source (하수열원 열펌프 시스템의 성능 시뮬레이션)

  • Park, Il-Hwan;Chang, Ki-Chang;Lee, Young-Soo;Yoon, Hyung-Kee;Baek, Young-Jeen
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.280-286
    • /
    • 2008
  • In this study, characteristics simulation of heat pump system is investigated for heating and cooling using sewage water as a heat source. A simulation program for preestimate operation characteristics of heat pump system is developed. The performance of this system is resolved by several variables and the characteristics which is based on actual air and sewage temperature data. The simulation results agree well with the experimental values of COP. In the analysis of system characteristics, the COP is changed between $3\sim5$ in winter season for heating load, $4\sim6$ in summer season for cooling load. As the results of Life Cycle Cost analysis over a 15 year life cycle, the energy cost could be reduced by 250 million won if a heat pump system was used instead of a conventional boiler and an absorbtion refrigerator on the office building.

Simulation Analysis on Performance Comparison between R744 and R22 Solar Hybrid Heat Pump (R744와 R22를 적용한 태양열 하이브리드 열펌프의 성능 시뮬레이션 비교 분석)

  • Kang, Byun;Cho, Honghyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.1-10
    • /
    • 2013
  • Simulation study of a solar hybrid heat pump using R744 and R22 for residential applications was carried out according to heat pump operating temperature, outdoor temperature and solar radiation. As a result, when the heat pump operating temperature increases from $40^{\circ}C$ to $48^{\circ}C$, the COP of a R744 and R22 heat pump system decrease from 2.15 to 1.7 and from 3.09 to 2.69, respectively. Besides, as the outdoor temperature rises from $3^{\circ}C$ to $11^{\circ}C$, the COP of R744 and R22 heat pump system increase from 1.73 to 2.12 and from 2.73 to 3.02. When the solar radiation increases from 10 to 20 $MJ/m^2$, the collector operating time and collector efficiency of R744 heat pump increase 10.3 times and 50.7%, respectively. The performance of R744 solar hybird heat pump is more sensitive to operation condition compared to that of R22. Besides, the solar heating system is more effective to the R744 heat pump system.

Simulation of Compression/Absorption Hybrid Heat Pump System using Industrial Wastewater Heat Source (산업폐수열원 이용 증기압축식/흡수식 하이브리드 히트펌프 시스템의 시뮬레이션)

  • Baik Young-Jin;Park Seong-Ryong;Chang Ki-Chang;Ra Ho-Sang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1117-1125
    • /
    • 2004
  • In this study, in order to utilize the waste heat of industrial wastewater in the range of the relatively low temperature of 40~5$0^{\circ}C$ as a heat source, a hybrid heat pump system was considered by computer simulation method. In the simulation, an absorber, desorber and solution heat exchanger were modelled by UA values while a compressor and pump performance were specified by an isentropic efficiency. Simulation results show that the performance of hybrid heat pump can be up to 80% higher than that of conventional R134a heat pump when it makes a process hot water of 9$0^{\circ}C$ while the wastewater is cooled down to 2$0^{\circ}C$. As the absorber pressure increases, the system performance and deserter pressure increase with a favorable effect of a compressor discharge gas temperature drop.

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

Study on the Performance Prediction Simulation of the Heat Pump System using Solar and Geothermal Heat Source (태양열 및 지열 이용 히트펌프 시스템의 성능예측 시뮬레이션에 관한 연구)

  • Nam, Yu-Jin;Gao, Xin-Yan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.75-81
    • /
    • 2014
  • Recently, the use of renewable energy has been attracted due to the interest in energy-saving and the reduction of CO2 emission. In order to reduce the energy consumption of the cooling and the heating in the field of the architectural engineering, heat pump systems using renewable energy have been developed and used in various applications. In many researches, integrated heat pump systems are suggested which use solar and geothermal heat as the heat source for cooling and heating. However, it is still difficult to predict the performance of the systems, because the characteristic of heat exchange in each system is complicated and various. In this system, the performance prediction simulation of the heat pump was developed using a dynamic simulation model. This paper describes the summary of the suggested systems and the result of the simulation. The average temperature of the heat source, heating loads and COP were calculated with the cases of different local conditions, different system composition and different operation time by TRNSYS 17.

Numerical Simulation on Dynamic Characteristics of a Water Heater System Driven by a Heat Pump (열펌프 가열식 온수기의 동적특성 해석)

  • 김민성;김민수;백남춘
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.10-20
    • /
    • 2002
  • A dynamic model of a water heater system heated by a heat pump was developed. The water heater system was composed of heat pump and hot water reservoirs. Finite volume method (FVM) was applied to describe the heat exchangers. A new constraint on electronic expansion valve (EEV) or thermostatic expansion valve (TXV) that can control superheat after the evaporator was developed. Dynamic performances were evaluated for various sizes of the reservoir. In order to compare those performances, time scale was normalized by time constant representing the characteristics of reservoir size. Time constant was determined from quasi steady-state simulation of the system. From the simulation, the size of the water heater reservoir was found to have a large influence on the transient performance of the sys- tem. Therefore, the optimization of the reservoir size is needed in a design process.

A Study on Improving the Efficiency of Ground Heat Exchanger (지중열교환기 성능 향상에 관한 연구)

  • Kim, Ook-Joong;Lee, Kong-Hoon;Kim, Min-Su
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3142-3147
    • /
    • 2008
  • A simple transient simulation of ground source heat pump system was carried out to investigate the effects of ground thermal conductivity on its performance. The TRNSYS code with a simple water to water heat pump model was used to compare the COP variation of the system. A new ground heat exchanger called by semi-closed loop was proposed and constructed in the real site. The effective thermal conductivity was measured using the test equipment developed by according to the line source model. The simulation results showed that highly efficient thermal conductivity of the grout material could increase the performance of the heat pump system very well. And the new ground heat exchanger showed the increased effective thermal conductivity as the penetration water flow rate(PWFR) was increased. Therefore, the performance improvement of the heat pump system using the proposed ground heat exchanger can be expected.

  • PDF

Analysis of Thermal Performance of Ground-Source Heat Pump System (지열 이용 열펌프 시스템의 열성능 해석)

  • Koh, Deuk-Yong;Shin, U-Cheul;Baek, Nam-Choon;Kim, Ook-Joong
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.167-172
    • /
    • 2005
  • The purpose of this study is to present the simulation results and an overview of the performance assessment of the Ground-Source Heat Pump(GSHP) system. The calculation was performed for two design factors. the spacing between boreholes and the depth of the vertical ground heat exchangers. And the simulation was carried out using the thermal simulation code TRNSYS with new model o( water to water heat pump developed by this study. As a result, it was anticipated that the yearly mean COPs of heat pump for heating and cooling are about 3.7 and 5.8 respectively and the heat pump can supply 100% of heating and cooling load all the year around.

  • PDF

Design method of heat storage type ground source heat pump system considering energy load pattern of greenhouse (원예시설의 에너지 부하패턴을 고려한 축열식 지열시스템 설계법에 관한 연구)

  • Yu, Min-Gyung;Nam, Yujin;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.57-63
    • /
    • 2015
  • Purpose: Ground source heat pump system has been attracted in the horticulture industry for the reduction of energy costs and the increasing of farm income. Even though it has higher initial costs, if it uses in combination with heat storage, it is able to reduce the initial costs and operate efficiently. In order to have significant effect of heat storage type ground source heat pump system, it is required to design the capacity considering various conditions such as energy load pattern and operating schedule. Method: In this study, we have designed heat storage type ground source heat pump system in 5 cases by the operating schedule, and examined the system to find the most economic and having superb performance regarding the system COP(Coefficient of Performance) and energy consumption, using dynamic energy simulation, TRNSYS 17. Result: Conventional ground source heat pump system has lower energy consumption than heat storage type, but following the result of LCC(Life Cycle Cost) analysis, the heat storage type was more economic due to the initial costs. In addition, it has the most efficient performance and energy costs in the case of the smallest heat storage time.

Basic Simulation for Vuilleumier Cycle Heat Pump (VM사이클 히트펌프 기초 설계프로그램)

  • Park, Byung-Duck
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.3
    • /
    • pp.265-273
    • /
    • 2000
  • Basic simulation program for Vuilleumier cycle heat pump was developed that can use precise VMHP design and analysis. VMHP system was divided 11 sections in simulation. Simulation was used adiabatic model analysis and that considered with heat transfer performance for heat exchanger, regenerator loss, conduction loss, shuttle loss, pumping loss and pressure loss by flow friction. Specially, friction loss of connection pipe between heat compression side and heat pump side, leakage of rod seal and piston seal was considered in the analysis.

  • PDF