• Title/Summary/Keyword: Heat pump

Search Result 1,579, Processing Time 0.029 seconds

An Experimental Study on the Thermal Performance Measurement of Large Diameter Borehole Heat Exchanger(LD-BHE) for Tripe-U Pipes Spacer Apply (3중관용 스페이서를 적용한 대구경 지중열교환기의 성능측정에 관한 연구)

  • Lee, Sang-Hoon;Park, Jong-Woo;Lim, Kyoung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.581-586
    • /
    • 2009
  • Knowledge of ground thermal properties is most important for the proper design of large scale BHE(borehole heat exchanger) systems. The type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for insitu determination of design data for large diameter BHE for triple-U spacer apply. The main purpose has been to determine insitu values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a circulation pump, a inline heater, temperature sensors, flow meter, power analysis meter and a data logger for recording the temperature, fluid flow data. A constant heat power is injected into the borehole through the tripl-U pipes system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance of large diameter BHE for spacer apply.

  • PDF

Numerical Simulation of a Heat Pump Evaporator Considering the Pressure Drop in the Distributor and Capillary Tubes (분배기와 모세관을 고려한 히트펌프용 증발기 성능 모사)

  • Park, Young-Gi;Ye, Huee-Youl;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.476-486
    • /
    • 2012
  • A simulation program was developed to evaluate the heat transfer performance of a multi-pass fin-tube evaporator, considering the pressure drop in the distributor and capillary tubes. The effect of capillary tube length for each pass was analyzed with various inlet air flow types and distributions. The appropriate capillary tube length distribution and correlation were determined for various inlet air flow types and distributions. The correlated results agreed well with the simulation, with an average error of less than 7%. By applying an optimal capillary tube length distribution, the heat transfer rate was increased by 4~5% compared to cases with uniform tubelength distributions, for each of the inlet air flow types and distributions considered in this study.

A Study on the Potential Energy Reserve Amount of Domestic River Water as Unutilized Energy Resource (국내 하천수 미활용에너지 부존량에 관한 조사연구)

  • Park Il-Hwan;Yoon Hyung-Kee;Park Jun-Taek;Chang Ki-Chang;Lee Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.521-528
    • /
    • 2005
  • This study has been conducted to investigate the potential energy reserve amount of river water as energy resource with useful temperature difference. Since the river water temperature is one of the primary parameters deciding the potential amount of river water energy reserve amount, the climate change effects on it are critically important. In this study, the heat exchange processes and the inter-relationship between the air temperature and river water temperature have been theoretically analyzed. Based on the present study, the potential energy reserve of river water is calculated to amount to 192,000 Tcal/year. Among this, it is estimated that approximately 2,000 Tcal/year can be directly utilized for heat pump energy sources.

Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

  • Hedayat, Afshin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.953-967
    • /
    • 2017
  • In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank), safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal-hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.

Numerical Simulation of Standing Column Well Ground Heat Pump System Part II: Parametric Study for Evaluation of the Performance of Standing Column Well (단일심정 지열히트펌프의 수치적 모델링 Part II: 단일심정 지열히트펌프의 성능평가를 위한 매개변수 연구)

  • Park, Du-Hee;Kim, Kwang-Kyun;Kwak, Dong-Yeop;Chang, Jae-Hoon;Na, Sang-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.2
    • /
    • pp.45-54
    • /
    • 2010
  • The SCW numerical model described in the companion paper was used to carry out a comprehensive parametric study to evaluate the performance of the SCW. The five ground related parameters, which are porosity, hydraulic conductivity, thermal conductivity, specific heat, geothermal gradient, and five SCW design parameters, which are pumping rate, well depth, well diameter, dip tube diameter, bleeding rate, were used in the study. Two types of numerical simulations were performed. The first type was used to perform short-term (24-hour) simulation, while the second type 14 day simulation. The study results indicate that the parameters that have important influence on the performance of SCW were hydraulic conductivity, thermal conductivity, geothermal gradient, pumping rate, and bleeding rate. The thermal conductivity had the most important influence on the performance of the SCW. With the increase in the geothermal gradient, the performance increased in the heat mode, but decreased in the cooling mode. The hydraulic conductivity influenced the performance when the value was larger than $10^{-4}m/s$. The depth of the well increased the performance, but at the cost of increased cost of boring. The bleeding had an important influence on SCW, greatly enhancing the performance at a limited increased cost of operation. Overall, this study showed that various factors had a cumulative influence on the performance of the SCW, and a numerical simulation can be used to accurately predict the performance of the SCW.

LOX conditioning을 위한 재순환배관의 성능해석 및 설계인자 파악

  • Kwon, Oh-Sung;Cho, Nam-Kyung;Chung, Yong-Gab;Cho, In-Hyun
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.196-202
    • /
    • 2005
  • In cryogenic feeding system of turbo pump fed liquid-propulsion rocket, rise of cryogenic propellant temperature can bring into geysering in pipe or cavitation in turbo pump. In this paper, performance analysis of recirculation line which is one of the method to inhibit these phenomenon is carried out based on the configuration of KSLV-I 1st stage LOX feeding system, and parametric study to find design parameter. Diameter and re-entrance height, initial LOX temperature, ullage pressure, and natural convection heat transfer coefficient are varied to see the effects on performance. Additional He is injected into recirculation line to promote LOX recirculation. 1-dimensional analysis using network-solver, SINDA/FLUINT is carried out.

  • PDF

Process Design and Analysis of BOG Re-liquefaction System with Pre-liquefaction of NGL (NGL 분리식 BOG 재액화 공정 고안 및 해석)

  • Yun, Sang-Kook
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.32-37
    • /
    • 2015
  • The boil-off-gases(BOG) in cryogenic LNG storage tanks are generating continuously due to the heat leakage and need to be re-liquefied by the effective way. As the present method to reliquefy BOG is using LNG cold energy to be supplied after low pressure primary pump, the demand of LNG flow rate should be over 10 times of BOG produced rate to reliquefy it. This research invented new effective re-liquefaction system having only 3~4 times of LNG flow rate against unit BOG, that the pre-liquefaction process of NGL and the use of high pressure LNG cold energy after secondary pump. By the analysis, it could be high efficient reliquefying system for all amount of BOG treatment even during the summer time, and improvement of operation safety and efficiency of LNG terminal.

The Influences of LiBr Solution Recirculation in Absorber on the Absorption Chiller Performance (흡수기 용액 재순환이 흡수식 냉동기 성능에 미치는 영향)

  • Jeong, Jong-Su;Jin, Seong-Min;Park, Chan-U;Choe, Seung-Hak;Jeong, Bong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.733-741
    • /
    • 2002
  • If a part of the poor solution from the absorber outlet is recirculated to the absorber inlet, the solution temperature at the solution spray pump can be reduced, and the solution flow rate in the absorber is increased. We have performed the experiments on the influences of the absorption chiller performance according to the ratio of the recirculation, defined as the ratio of the recirculation flow rate to the total solution flow rate at the absorber outlet. As increasing the ratio of the recirculation, the absorption capacity of the solution can be deteriorated. On the other hand, due to the increasing flow rate, the heat transfer rate can be enhanced. As a result, the performance of the absorber and the cooling capacity of the absorption chiller have nothing to do with the recirculation ratio, and the lifetime of the spray pump will be maintained.

A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions (흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구)

  • 박찬우;조현철;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

Real-time steady state identification technology of a heat pump system to develop fault detection and diagnosis system (열펌프의 고장감지 및 진단시스템 구축을 위한 실시간 정상상태 진단기법 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.282-287
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF