Analysis of the Effect of Fog Cooling during Daytime and Heat Pump Cooling at Night on Greenhouse Environment and Planst in Summer (하절기 주간 포그 냉방과 야간 히트펌프 냉방이 온실 환경 및 작물에 미치는 영향 분석)

  • Lee, Taeseok;Kim, Jingu;Park, Seokho;Lee, Choungkeun
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.328-334
    • /
    • 2021
  • This study was conducted to analyze the effect of fog cooling during daytime and heatpump cooling at night in greenhouses in summer. During daytime, the average temp. and RH of the control greenhouse which had shading screen were 32.1℃ and 59.4%. and the average temp. and RH of the test greenhouse which had fog cooling were 30.0℃ and 74.3%. At this time, the average outside temp. and RH were 31.4℃ and 57.7%. So, the temp. of the control was 0.7℃ higher than outside temp., but the temp. of the test was 1.4℃ lower than outside and 2.1℃ lower than control. The average RH was 74.3% in the test and 59.4% in control. The average temp. and RH of the control greenhouse which had natural ventilation at night were 25.2℃ and 85.1%, and the average temp. and RH of the test greenhouse which had heat pump cooling were 23.4℃, 82.4%. The average outside temp. and RH at night were 24.4℃ and 88.2%. The temp. of the control was 0.8℃ higher than outside temp., but the temp. of the test was 1.0℃ lower than outside and 1.8℃ lower than control. The average RH was 82.4% in test and 85.1% in control greenhouse. There was no significant difference between the plants growth eight weeks after planting. But after the cooling treatment, the values of stem diameter, plant height, chlorophyll in test were higher than control. The total yield was 81.3kg in test, 73.8kg in control, so yield of test was 10.2% higher than control. As a result of economic analysis, 142,166 won in profits occurred in control greenhouse, but 28,727 won in losses occurred in test greenhouse, indicating that cooling treatment was less economical.

Effects of Local Cooling and Root Pruning on Budding and Local Heating on Heating Energy Consumption in Forcing Cultivation of Strawberry (딸기 촉성재배 시 국소 냉방 및 단근처리와 국소난방이 화방출뢰와 난방에너지소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Suk Won;Paek, Yee;Moon, Jong Pil;Jang, Jae Kyung;Oh, Sung Sik
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.46-54
    • /
    • 2019
  • Experiments of local cooling and heating on crown and root zone of forcing cultivation of strawberry 'Seolhyang' using heat pump and root pruning before planting were conducted. During the daytime, the crown surface temperature of the crown local cooling treatment was maintained at $18{\sim}22^{\circ}C$. This is suitable for flower differentiation, while those of control and root zone local cooling treatment were above $30^{\circ}C$. Budding rate of first flower clusters and initial yields were in the order of crown local cooling, root zone local cooling and control in root pruning plantlet and non pruning plantlet, except for purchase plantlet. Those of root pruning plantlet were higher than those of non pruning plantlet. These trends were evident in the yield of the first flower cluster until February 14, 2018, and the effect of local cooling and root pruning decreased from March 9, 2018. The budding rates of the second flower cluster according to the local cooling and root pruning treatments were not noticeable compared to first flower cluster but showed the same tendency as that of first flower cluster. In the heating experiment, root zone local heating(root zone $20^{\circ}C$+inside greenhouse $5^{\circ}C$) and crown local heating(crown $20^{\circ}C$+inside greenhouse $5^{\circ}C$) saved 59% and 65% of heating fuel, respectively, compared to control(inside greenhouse $9^{\circ}C$). Considering the electric power consumption according to the heat pump operation, the heating costs were reduced by 55% and 61%, respectively.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Open Heart Surgery of Congenital Heart Diseases -Report of Four Cases- (선천성심질환(先天性心疾患)의 심폐기(心肺器) 개심수술(開心手術) - 4례(例) 보고(報告) -)

  • Kim, Kun Ho;Park, Young Kwan;Jee, Heng Ok;Kim, Young Tae;Rhee, Chong Bae;Chung, Yun Chae;Oh, Chull Soo
    • Journal of Chest Surgery
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1976
  • The present. study reports four cases of congenital heart diseases, who received open heart surgery by the Sarn's Heart-Lung-Machine in the department of Thoracic Surgery, Hanyang University Hospital during the period between July 1975 and May 1976. The Heart-Lung-Machine consisted of the Sarn's five head roller pump motor system (model 5000), heat exchanger, bubble trap, the Rygg-Kyvsgaard oxygenator, and monitors. The priming of pump oxygenator was carried out by the hemodilution method using Hartman's solution and whole blood. Of the four cases of the heart diseases, three whose body weight were below 30kg, received the partial hemodilution priming and the remaining one whose body weight was 52kg received the total hemodilution priming with Hartman's solution alone. The rate of hemodilution was in the average of 60.5ml/kg. Extracorporeal circulation was performed at the perfusion flow rate of the average 94.0ml/kg/min, and at the moderate hypothermia between 35'5"C and 30'5"C of the rectal temperature. In the total cardiopulmonary bypass, arterial blood pressure was anged between 30 mmHg and 85 mmHg, generally maintaining over 60 mmHg and venous pressure was measured between 4 and $23cmH_2O$, generally maintaining below $10cmH_2O$. The first case: The patient, a nine year old girl having the symptoms and physical signs typical to cardiac anomaly was definitely diagnosed as isolated pulmonary stenosis through the cardiac catheterization. There was, however, no cyanosis, no pathological finding by X-ray and E.C.G. tracings. The valvulotomy was performed through the arteriotomy of pulmouary artery under the total cardiopulmonary bypass. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The second case: A 12 year old boy with congenital heart anomaly was positively identified as having ventricular septal defect through the cardiac catheterization. As in the case with the first case, the patient exhibited the symptoms and physical signs typical to cardiac anomaly, but no pathological abnormality by X-ray and E.C.G. tracings. The septal defect was localized on atrioventricular canal and was 2 by 10 mm in size. The septal defect was closed by direct simple sutures under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle and pulmonary artery were decreased satisfactory. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The third case: The patient, a 19 year old girl had been experienced the clinical symptoms typical to cardiac anomaly for 16 years. The pink tetralogy of Fallot was definitey diagnosed through the cardiac catheterization. The patient was placed on an ablolute bed rest prior to the operation because of severe exertional dyspnea, fatigability, and frequent syncopal attacks. However, she exhibited very slight cyanosis. Positive findings were noted on E.C.G. tracings and blood picture, but no evidence of pathological abnormality on X-ray was observed. All of the four surgical approaches such as Teflon patch closure (3 by 4cm in size) of ventricular septal defect, myocardial resection of right ventricular outflow tract, valvulotomy of pulmonary valvular stenosis, and pericardial patch closing of ventriculotomy wound were performed in 95 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The fourth case: The patient, a 7 1/4 year old girl had the symptoms of cardiac anomaly for only three years prior to the operation. She was positively identified as having acyanotic tetralogy of Fallot by open heart surgery. The patient showed positive findings by X-ray and E.C.G. tracings, but exhibited no cyanosis and normal blood picture. All of the three surgical approaches, such a myocardial resection of hypertrophic sight ventricular outflow tract, direct suture closing of ventricular septal defect and pericardial patch closing of ventriculotomy wound were carried out in 110 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and the symptoms disappeared.

  • PDF

Development of air-conditioning and drinking water supply system using air-water heat pump (공기-물 히트펌프를 이용한 공조 및 음용수급수시스템 개발)

  • Paek, Yee;Kang, Sukwon;Jang, Jae-Kyung;Kim, Young-Hwa
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.118-118
    • /
    • 2017
  • 지구 온난화에 따른 환경변화로 인하여 최근 10년('02~'11)간 여름의 일수는 4일, 겨울 일수는 16일 각각 증가하였다. 현재 육계사 내의 고밀도 밀집사육으로 인하여 고온스트레스로 하절기 육계의 폐사율이 증가하고 있는 실정이다. 2016년 폭염으로 닭 406.1천수, 오리 15.7천수, 메추리 70천수, 돼지 8천수가 폐사하였다. 이에 혹서기 가축이 약430만수가 폐사하였으며 피해 보상금액 128억원 소요되었다. 본 연구에서는 하절기 고온스트레스 경감과 폐사율 저감을 위해 계사 냉난방 공조와 냉온 음용수 급수를 병행할 수 있는 고효율 환경 개선 시스템을 개발하여 고온스트레스 저감 및 생산성 향상에 목적이 있다. 계사 냉난방 공조 및 냉온음용수 급수 병행 시스템 설계요인을 분석하고 냉난방 공조부하, 냉온수 생산 부하를 고려한 시스템 용량 산정하고 히트펌프, 축열조, 냉난방 및 냉온수 분배장치 등 구성요소로서 공조 및 냉온음용수 급수시스템을 설치하였다. 시스템 용량은 공기-물 히트펌프(10kW,1대), 축열조(10톤), 음용수조(2톤), 열교환기(열교환량,5만kcal/h), 물순환펌프(250W,2대) 및 팬코일유닛(1만kcal/h,4대)으로 시스템 모니터링 및 제어 시스템 개발하여 계사 내 환경, 시스템 성능에 대한 실시간 모니터링을 통하여 저장하였다. 조사항목으로 위치별 온습도, 체중, 사료섭취량, 페사율 등을 조사 분석하였다. 연구결과 계사의 내부온도는 시험구에서는 평균 $25.3^{\circ}C$를 나타내었고 대조구에서는 평균 $28.1^{\circ}C$로서 $2.8^{\circ}C$ 높게 나타났으나 상대습도는 시험구 76.2%, 대조구 75.0%로 큰 차이가 없었다. 냉수급여에 따른 계사 높이별 내부온도는 상하의 온도차가 $4.5^{\circ}C$로 크게 차이가 났다. 육계의 음수량은 혹서기 냉수를 급여한 시험구에서 일일 23.2L, 대조구에서는 21.5L를 섭취하였다. 일일 사료섭취량은 냉수를 급여한 시험구에서 937g, 대조구에서는 725g을 섭취하였다. 사료섭취량은 냉수를 급여한 시험구가 212g 많이 섭취하였으며 사료요구율은 시험구는 1.86, 대조구는 1.91로서 시험구가 낮게 나타났다. 체중은 냉수를 급여한 시험구가 359g 많았으며 증체량은 냉수를 급여한 시험구에서 495g, 대조구에서는 392g으로 나타났다. 폐사율은 냉수를 급여한 시험구에서 84%가 폐사율을 줄일 수 있었다.

  • PDF

Prediction of adiabatic capillary tube length of a vehicle heat pump using carbon dioxide (수송기계 $CO_2$ 히트펌프용 단열 모세관 길이 예측에 관한 연구)

  • Oh, Hoo-Kyu;Choi, Kwang-Hwan;Son, Chang-Hyo;Jeon, Min-Ju
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.277-277
    • /
    • 2011
  • 본 논문은 $CO_2$ 히트펌프용 모세관의 기초 설계자료를 제공하기 위해서 모세관 길이 예측에 대해서 이론 및 실험적으로 조사하였다. 본 연구에서 고려된 작동변수로는 증발온도, 가스냉각기 냉각압력, 냉매유량, 모세관의 관경 등이다. 몇몇연구자들의 자료를 바탕으로 $CO_2$ 모세관 길이를 예측할 수 있는 수학적 모델식을 작성하였다. 그리고 단열 모세관 팽창장치내 $CO_2$의 증발온도, 냉매유량, 냉각압력 등에 대해서 실험한 결과, Fig. 1에 나타낸 것처럼, 모세관 길이가 증가할수록 증발온도는 감소하는 것을 알 수 있다. 그리고 증발온도에 대한 실험값과 예측값의 비교 결과, 실험값이 예측값보다 약간 높게 나타났다. $CO_2$냉매가 모세관내를 통과할 때 플래쉬 가스(flash gas)의 발생으로 인해 액상의 양보다 기상의 양이 많아지고 액상의 압력강하보다 기상의 압력강하가 휠씬 더 크기 때문이다. 또한 증발온도에 대한 실험값과 예측값은 6.5~9.9% 이내에서 좋은 일치를 보였다. Fig. 2에 나타낸 것처럼, 모세관 길이가 증가할수록 냉매유량은 감소하는 것을 알 수 있다. 이는 전술한 바와 같이 모세관 길이가 증가할수록 냉매 압력강하가 더욱더 증가하기 때문이다. 그리고 냉매유량에 대한 실험값과 예측값의 비교 결과, 실험값이 예측값보다 약간 높게 나타났다. 이는 전술한 증발온도와 동일한 이유로 실제 $CO_2$냉매가 모세관내를 통과할 때 플래쉬 가스의 발생량이 많아지기 때문이다. 또한 냉매유량에 대한 실험값과 예측값은 0.64~10.9% 이내에서 좋은 일치를 보였다. Fig. 3에 나타낸 것처럼, 모세관 길이가 증가할수록 냉각압력은 증가하는 것을 알 수 있다. 이는 증발온도가 일정한 경우 모세관 길이가 증가할수록 냉매유량이 감소하여 압축기 토출측 온도(압력)가 상승하기 때문이다. 그리고 냉각압력에 대한 실험값과 예측값의 비교 결과, 실험값이 예측값보다 약간 낮게 나타났으며 실험값과 예측값은 1.04~3.7% 이내에서 좋은 일치를 보였다. 따라서 본 연구에서는 수송기계용 $CO_2$ 열펌프 단열 모세관에 대한 기초설계 자료로서, 냉각압력, 증발온도, 모세관 직경, 냉매유량 등의 조건으로부터 모세관 길이를 계산해낼 수 있는 예측 상관식을 제안하였다.

  • PDF

Calculation of non-condensable gases released in a seawater evaporating process (해수 증발과정에서의 기체방출량 계산)

  • Jeong, Kwang-Woon;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.182-190
    • /
    • 2017
  • All liquids contain a small amount of gaseous components and the amount of gases dissolved in a liquid is in accordance with Henry's Law. In a multi-stage thermal-type seawater desalination plant, as the supplied seawater undergoes variations in temperature and pressure in each evaporator, the gases dissolved in the seawater are discharged from the liquid. The discharged gases are carbon dioxide, nitrogen, oxygen, and argon, and these emitted gases are non-condensable. From the viewpoint of convective heat transfer, the evaluation of non-condensable gas released during a vacuum evaporation process is a very important design factor because the non-condensable gases degrade the performance of the cooler. Furthermore, in a thermal-type seawater desalination plant, most evaporators operate under vacuum, which maintained through vacuum system such as a steam ejector or a vacuum pump. Therefore, for the proper design of a vacuum system, estimating the non-condensable gases released from seawater is highly crucial. In the study, non-condensable gases released in a thermal-type seawater desalination plant were calculated quantitatively. The calculation results showed that the NCG releasing rate decreased as the stage comes getting a downstream and it was proportional to the freshwater production rate.

Energy Economic Analysis of Standard Rural House Model with PV System (PV 시스템이 적용된 농어촌 주택 표준모델의 에너지 경제성 분석)

  • Lee, Chan Kyu;Kim, Woo Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1540-1547
    • /
    • 2013
  • The energy economic analysis of the standard rural house model with PV system was performed based on annual energy demand calculation using the EnergyPlus to contribute in reducing building energy which occupies 25% of national energy consumption and in developing a low-energy & eco-friendly house model. Two types of PV system installation was considered to cover electricity demand for cooling, electric, and heating devices. For the selected house model, heating energy demand is 7 times higher than cooling energy demand. For the Case1, it is favorable to use electricity from PV system for cooling and electric devices and to sell surplus electricity. For the Case2, it is favorable to use electricity from PV system for cooling, electricity and heating devices and to sell surplus electricity. Considering the installation cost of PV system and heat pump air conditioning system, the break-even point of Case1 and Case2 are about 13 and 11 years respectively. Although the installation cost of Case2 is more expensive, Case2 provides three times more profit than Case1 after the break-even point. Because the expected average life time of the selected PV system is 25 years, Case2 is more favorable option for the given standard rural house model.

Investigation of Hydraulic Flow Properties around the Mouths of Deep Intake and Discharge Structures at Nuclear Power Plant by Numerical Model (수치모의를 통한 원자력 발전소 심층 취·배수 구조물 유·출입구 주변에서의 수리학적 흐름특성 고찰)

  • Lee, Sang Hwa;Yi, Sung Myeon;Park, Byong Jun;Lee, Han Seung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.123-130
    • /
    • 2012
  • A cooling system is indispensable for the fossil and nuclear power plants which produce electricity by rotating the turbines with hot steam. A cycle of the typical cooling system includes pumping of seawater at the intake pump house, exchange of heat at the condenser, and discharge of hot water to the sea. The cooling type of the nuclear power plants in Korea recently evolves from the conventional surface intake/discharge systems to the submerged intake/discharge systems that minimize effectively an intake temperature rise of the existing plants and that are beneficial to the marine environment by reducing the high temperature region with an intensive dilution due to a high velocity jet and density differential at the mixing zone. It is highly anticipated that the future nuclear power plants in Korea will accommodate the submerged cooling system in credit of supplying the lower temperature water in the summer season. This study investigates the approach flow patterns at the velocity caps and discharge flow patterns from diffusers using the 3-D computational fluid dynamics code of $FLOW-3D^{(R)}$. The approach flow test has been conducted at the velocity caps with and without a cap. The discharge flow from the diffuser was simulated for the single-port diffuser and multi-ports diffuser. The flow characteristics to the velocity cap with a cap demonstrate that fish entrainment can significantly be minimized on account of the low vertical flow component around the cap. The flow pattern around the diffuser is well agreed with the schematic diagram by Jirka and Harleman.

Thermoeconomic Analysis of Hybrid Desiccant Cooling System Driven by District Heating (지역난방에 연계된 하이브리드 제습냉방시스템의 경제성 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.721-729
    • /
    • 2014
  • A hybrid desiccant cooling system (HDCS) that uses a heat pump driven by district heating instead of a sensible rotor can provide an increased energy efficiency in summer. In this paper, the summer operation costs and initial costs of both the HDCS and traditional systems are analyzed using annual equal payments, and national benefits are found from using the HDCS instead of traditional systems. In the analysis results, the HDCS reduces the operation cost by 30 compared to the traditional systems, and each HDCS unit has 0.079 TOE per year of primary energy savings and 0.835 $TCO_2$ per year of $CO_2$ emission reduction more than the traditional systems. If HDCSs were to be installed in 680,000 households by 2020, this would produce a replacement power effect of 463 MW. Despite this savings effect, HDCSs require a government subsidy before they can be supplied because the initial cost is higher than that of traditional systems. Thus, this paper calculates suitable subsidies and suggests a supply method for HDCSs considering the national benefits.