• 제목/요약/키워드: Heat intensity

검색결과 774건 처리시간 0.027초

Heat Island Intensity in Seongseo, Daegu, South Korea - a Rural Suburb Containing Large Areas of Water

  • Kim, Ki-Young;Byon, Jae-Young;Kim, Hae-Dong
    • 한국환경과학회지
    • /
    • 제22권10호
    • /
    • pp.1337-1344
    • /
    • 2013
  • We examined urban heat island intensity in Seongseo, Dae gu, South Korea, where a large area of water is located within the suburb. We found a maximum urban heat island intensity of $4.2^{\circ}C$, which occurred around 7 PM in the summer season. Throughout the remainder of the year, we observed the largest heat island intensity levels during late night hours. In contrast, the winter season displayed the smallest values for heat island intensity. Our results conflicted with heat island intensity values for cities where suburbs did not contain water areas. Generally, cities with suburbs lacking water displayed the largest heat island intensity levels before sunrise in the winter season. We also observed negative urban heat island intensity levels at midday in all seasons except for the summer, which is also in contrast with studies examining suburbs lacking water areas. The heat island intensity value observed in this study ($4.2^{\circ}C$) was relatively large and fell between the averages for, Asia and Europe according to the relationship between urban population and heat island intensity.

대구지역의 기상조건에 따른 도시열섬강도의 계절별 변화특성 (On the Seasonal Variation of Urban Heat Island Intensity According to Meteorological Condition in Daegu)

  • 안지숙;김해동
    • 한국환경과학회지
    • /
    • 제15권6호
    • /
    • pp.527-532
    • /
    • 2006
  • The purpose of this study is to clarify the characteristic of urban heat island intensity in urban area formed at a basin. Thermal environments for basin-type cities are influenced by significant topographic relief winds. In this study, we analyzed the diurnal variations of the heat island intensity according to meteorological condition and season using AWS(Automatic Weather observation System) data in Daegu Metropolitan area for 1 year(3/April, 2003 $\sim$ 2/April, 2004). In this study, we defined the urban heat island intensity as the air temperature difference between two points, the downtown and the suburban area. The suburban area is located at valley mouth around the western tip of Daegu. The results are summarized as follows; 1. The maximum heat island intensity was recorded at early morning under the meteorological conditions, calm and clear 2. The heat island intensity was strong in the order of winter, fall, spring and summer. 3. The heat island intensity came out minus values in the afternoon. This phenomenon is known as a com mon for basin-type cities. 4. The heat island intensity was twice or more in clear and calm than not so.

가스터빈 베인 끝벽의 열전달 특성 및 정압분포 측정 (Measurement of Heat Transfer and Pressure Distributions on a Gas Turbine Vane Endwall)

  • 이용진;신소민;곽재수
    • 한국항공운항학회지
    • /
    • 제14권2호
    • /
    • pp.33-38
    • /
    • 2006
  • Heat transfer coefficients and static pressure distributions on a gas turbine vane endwall were experimentally investigated in a 5 bladed linear cascade. The Reynolds number based on an axial chord length and the cascade exit velocity was 500,000. Both heat transfer and pressure measurements on the vane endwall were made at the two different turbulence intensity levels of 6.8% and 10.8%. Detailed heat transfer coefficient distributions on the vane endwall region were measured using a hue detection based transient liquid crystals technique. Results show various regions of high and low heat transfer coefficients on the vane endwall surface due to several types of secondary flows and vortices. Heat transfer coefficient and endwall static pressure distributions showed similar trends for both turbulence intensity, however, the averaged heat transfer coefficients for higher turbulence intensity case was higher than the lower turbulence intensity case by 15%.

  • PDF

2차원 채널 충돌제트에서 난류강도의 변화에 대한 유동 및 열전달 특성 (A Characteristics of Flow and Heat Transfer for Variation of Turbulence Intensity In the Two-Dimensional Channel Impinging Jet)

  • 윤순현;김동건;김문경
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.753-760
    • /
    • 1999
  • Experiments were conducted to investigate the effect of the initial turbulent intensity on the flow and heat transfer characteristics for a two-dimensional impinging jet. A square rod was installed at the nozzle exit to increase initial turbulent intensity. A hot wire probe and thermochromic liquid crystal technique were used to measure the turbulent intensity and the surface temperature. All measurements were made over a range of nozzle-to-plate distance from 1 to 10 at Re=20,000. When the rod is not installed, the maximum stagnation point Nusselt number is occurred at H/B=9. A higher initial turbulent intensity enhanced the heat transfer on the surface. A correlation between stagnation point Nusselt number and turbulent intensity are presented.

통합모델을 활용한 이류와 도시비율이 서울 수도권 지역의 도시열섬강도에 미치는 영향 분석 (Analysis of the Effects of Advection and Urban Fraction on Urban Heat Island Intensity using Unified Model for Seoul Metropolitan Area, Korea)

  • 홍선옥;김도형;변재영;박향숙;하종철
    • 대기
    • /
    • 제29권4호
    • /
    • pp.381-390
    • /
    • 2019
  • This study investigates the impacts of urban land-use fraction and temperature advection on the urban heat island intensity over the Seoul metropolitan area using the UM (Unified Model) with the MORUSES (Met Office Reading Urban Surface Exchange Scheme) during the heat wave over the region from 2 to 8, August 2016. Two simulations are performed with two different land-use type, the urban (urban simulation) and the urban surfaces replaced with grass (rural simulation), in order to calculate the urban heat island intensity defined as the 1.5-m temperature difference between the urban and the rural simulations. The land-use type for the urban simulation is obtained from Korea Ministry of Environment (2007) land-use data after it is converted into the types used in the UM. It is found that the urban heat island intensity over high urban-fraction regions in the metropolitan area is as large as 1℃ in daytime and 3.2℃ in nighttime, i.e., the effects of urban heat island is much larger for night than day. It is also found that the magnitude of urban heat island intensity increases linearly with urban land-use fraction. Spatially, the estimated the urban heat island intensities are systematically larger in the downwind regions of the metropolitan area than in the upwind area due to the effects of temperature advection. Results of this study indicate that urban surface fraction in the city area and temperature advection play a key role in determining the spatial distribution and magnitude of urban heat island intensity.

노출시간과 열강도에 따른 복사열 노출후의 소방보호복의 물리적 특성과 역학적 특성변화 (Changes of Physical and Mechanical Properties of Firefighter Protective Clothing After Radiant Heat Exposure)

  • 유화숙
    • 한국의류학회지
    • /
    • 제23권6호
    • /
    • pp.853-863
    • /
    • 1999
  • the change of physical properties (thickness, weight, air permeability) and mechanical properties(abrasion resistance breaking load and displacement) of samples were determined after heat exposure by a RPP tester. The effect of exposure time and heat flux intensity on the changes and the relationship between physical properties and mechanical properties were investigated. FR treated cotton Kevlar/PBI and Nomex with different structureal characteristics were chosen for specimens. The changes of physical properties and mechanical properties were calculated based on their initial values before heat exposure. The longer exposure time and the high heat flux intensity the more changes of those properties. Heat flux intensity was more effective on the changes, The showed to be affected by an interplay of shrinkage and pyrolysis products loss. The changes of thickness and abrasion resistance showed to be higher for plain weave fabric and those of air permeabiliyt and breaking load and displacement for twill weave fabric. While FR treated cotton which have high RPP value experienced serious and detrimental changes after heat exposure Kevlar/PBI which has low RPP value showed no high changes. In conclusion it could be confirmed that when total performance of a protective clothing is estimated retention capability of physical and mechanical properties after heat exposure as well as RPP value must be considered.

  • PDF

균열면에 작용하는 내압과 열전달의 영향을 고려한 노즐부의 응력확대계수 해석 (Stress Intensity Factor Analysis of Nozzle Considering Pressure and Heat Transfer on Crack Face)

  • 정민중;김영진;강기주;범현규;표창률
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2252-2258
    • /
    • 2000
  • In order to investigate the effect of nozzle on stress concentration in pressure vessels, three dimensional finite element analyses were performed. The results were compared with those for corresponding two dimensional axisymmetric finite element analyses. A three dimensional finite element model with a surface crack was also designed to evaluate the effect of internal pressure and heat transfer on crack face, and the resulting stress intensity factors from the finite element analyses were compared with those for ASME Sec. XI and Raju-Newman's stress intensity factor solution. As a result, the validity of currently available stress intensity factor solutions for a surface crack was reviewed in the presence of geometrical complexity, heat transfer and internal pressure.

주유동의 난류강도가 막냉각홀 주위의 열/물질전달 특성에 미치는 영향 (Effect of Free Stream Turbulence Intensity on Heat/Mass Transfer Characteristics Around a Film Cooling Hole)

  • 이동호;김병기;조형희
    • 한국추진공학회지
    • /
    • 제2권2호
    • /
    • pp.56-63
    • /
    • 1998
  • 본 논문에서는 주유동의 난류강도 변화에 따른 복합각도로 분사되는 단일 막냉각홀 주위에서의 국소 열/물질전달계수 특성을 살펴보기 위하여 실험을 수행하였다. 단일 막냉각홀 시편은 평면에 대하여 $30^{\cire}$의 경사각을 가지고 있으며, 횡방향으로는 주유동에 대해 $45^{\cire}$의 각도로 분사하여 복합각도 분사시 주유동의 난류강도 변화에 따른 효과를 살펴보았다. 또한 막냉각제트의 분사율을 0.5에서 2.0까지 변화시켜가며, 주유동의 높은 난류강도조건에서 분사율 변화시 막냉각홀 주위의 열/물질전달특성에 미치는 효과를 살펴보았다. 주유동의 난류강도를 변화시키기 위하여 막냉각홀 상류에 난류발생격자를 설치하였다. 격자를 설치하지 않은 경우, 주유동의 난류강도는 0.5%이며, 난류발생격자의 종류 및 설치위치를 달리하여 난류강도를 3%에서 10%까지 변화시켜가며 실험하였다. 막냉각홀 주위에서 국소적인 열/물질전달계수 값을 얻기 위하여 물질전달 실험방법인 나프탈렌 승화법을 사용하였다. 주유동의 난류강도가 낮은 경우 분사홀 주변에서 막냉각제트 혹은 주유동에 의한 열/물질전달 촉진영역이 뚜렷한 경계를 갖지만, 난류강도가 증가하면서 전 영역에 걸쳐 열/물질전달이 촉진되었으며 주유동과 막냉각제트의 활발한 혼합작용으로 인해 영역의 구분이 점차 소멸되었다. 또한 주유동의 높은 난류강도 효과는 막냉각제트의 분사율이 높은 경우 뚜렷이 나타났다.

  • PDF

GMA용접의 아크빛 모델 및 용접선 추적에의 응용 (Modeling of Are Light Intensity and Its Application to Weld Seam Tracking in GMAW)

  • 유용상;최상균;유중돈;선우희권
    • Journal of Welding and Joining
    • /
    • 제14권5호
    • /
    • pp.113-121
    • /
    • 1996
  • The arc sensor has been most widely used for weld seam tracking through welding current or voltage variation. In this work, the relation between the arc light intensity and welding condition is investigated using heat balance in the Plasma for its possible application to seam tracking in the GMAW process. The arc light intensity is derived to be the function of the arc length and welding current Experiments are carried out to verify the proposed heat balance model. Performances of least square and integration methods to process the signals for seam tracking are compared experimentally. Predicted arc light intensity shows reasonably good agreement with experimental results. The weld seam is successfully tracked through the arc light intensity. The least square and integration methods demonstrate almost same performance of seam tracking with $CO_2$gas shielding.

  • PDF

미세혈관 수술 후 혈관 연축의 예방을 위한 개선된 온열전등 (Improved Heat Lamp for Preventing Arterial Spasm after Microvascular Surgery)

  • 안성민;황소민;허은숙;박정미;박경아;오진아
    • Archives of Reconstructive Microsurgery
    • /
    • 제17권2호
    • /
    • pp.120-125
    • /
    • 2008
  • Purpose: Heat therapy by heat lamp after microvascular surgery is being used for preventing blood vessels's contraction and blood-flow's disturbance. As usually, incandescent lamp has been used. But there have been several problems and need for improvement in the existing heat lamp treatment. So we would like to introduce improved heat lamp to keep an appropriate temperature and intensity of illumination. Methods: The existing heat lamps are the ones of general light stands covered with newspaper, having 60 watt light bulb of incandescence and lampshade made of aluminum. We have tried to improve shortcomings of the existing heat lamps by enlarging the size of aluminum lampshade and attaching a curtain that can block heat and light. We conducted a comparative study between the existing and improved heat lamps. Under the assumption that there are several affected parts, we have also measured the distance from heat lamp to patients' eye region and then intensity of illumination. Result: The target temperature of surface was realized in 11 minutes with the maximum temperature reaching at 36.6 degrees C in 28 minutes at the existing heat lamp while the target temperature reached in 7 minutes with the maximum temperature reaching at 39.0 degrees C in 17 minutes at the improved heat lamp. The existing and improved heat lamp showed 38 lx and 0.1 lx of intensity of lumination, respectively. Conclusion: Using improved heat lamps, we can keep an appropriate temperature and we think we can make contribution to patients' treatment by making them and their neighbors able to sleep with minimized disturbance thanks to low intensity of illumination secured by blocking light.

  • PDF