CHANGE OF CATALYST TEMPERATURE WITH UEGI TECHNOLOGY DURING COLD START

  • CHO Y.-S.;KIM D.-S.
    • International Journal of Automotive Technology
    • /
    • v.6 no.5
    • /
    • pp.445-451
    • /
    • 2005
  • Most of the pollutants from passenger cars are emitted during the cold-transient phase of the FTP-75 test. In order to reduce the exhaust emissions during the cold-transient period, it is essential to warm up the catalyst as fast as possible after the engine starts, and the Unburned Exhaust Gas Ignition (UEGI) technology was developed through our previous studies to help close-coupled catalytic converters (CCC) reach the light-off temperature within a few seconds after cold-start. The UEGI system operates by igniting the unburned exhaust mixture by glow plugs installed upstream of the catalyst. The flame generates a high amount of heat, and if the heat is concentrated on a specific area of monolith surface, then thermal crack or failure of the monolith could occur. Therefore, it is very important to monitor the temperature distribution in the CCC during the UEGI operation, so the local temperatures in the monolith were measured using thermocouples. Experimental results showed that the temperature of CCC rises faster with the UEGI technology, and the CCC reaches the light-off temperature earlier than the baseline case. Under the conditions tested, the light-off time of the baseline case was 62 seconds, compared with 33 seconds for the UEGI case. The peak temperature is well under the thermal melting condition, and temperature distribution is not so severe as to consider thermal stress. It is noted that the UEGI technology is an effective method to warm up the catalyst with a small amount of thermal stress during the cold start period.

Temperature Analysis for Optimizing the Configuration of the Linear Cell

  • Choi Jong-Wook;Kim Sung-Cho;Kim Jeong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.1089-1097
    • /
    • 2006
  • The market demand of display devices is drastically increasing in the information technology age. The research on OLED (Organic Light Emitting Diodes) display with the luminescence in itself is being more paid attention than LCD (Liquid Crystal display) with the light source from the back. The vapor deposition process is most essential in manufacturing OLED display. The temperature distribution of the linear cell in this process is closely related to securing the uniformity of organic materials on the substrate. This work analyzed the temperature distribution depending on the intervals between the crucible and the heating band as well as on the amount of the heat flux from the heating band. Moreover, the roles of the water jacket and the configuration of the cover within the linear cell were examined through the temperature analysis for six configurations of the linear cell. Under the above temperature analysis, the variations in the intervals and the amount of the heat flux were considered to have an effect on building the uniform temperature distribution within the crucible. It is predicted that the water jacket and the adequate configuration of the cover will prevent the blowout and clogging phenomena, respectively. The results can be used as the fundamental data for designing the optimal linear cell.

ENHANCEMENT OF DRYOUT HEAT FLUX IN A DEBRIS BED BY FORCED COOLANT FLOW FROM BELOW

  • Bang, Kwang-Hyun;Kim, Jong-Myung
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.297-304
    • /
    • 2010
  • In the design of advanced light water reactors (ALWRs) and in the safety assessment of currently operating nuclear power plants, it is necessary to evaluate the possibility of experiencing a degraded core accident and to develop innovative safety technologies in order to assure long-term debris cooling. The objective of this experimental study is to investigate the enhancement factors of dryout heat flux in debris beds by coolant injection from below. The experimental facility consists mainly of an induction heater, a double-wall quartz-tube test section containing a steel-particle bed and coolant injection and recovery condensing loop. A fairly uniform heating of the particle bed was achieved in the radial direction and the axial variation was within 20%. This paper reports the experimental data for 3.2 mm and 4.8 mm particle beds with a 300 mm bed height. The dryout heat density data were obtained for both the top-flooding and the forced coolant injection from below with an injection mass flux of up to $1.5\;kg/m^2s$. The dryout heat density increased as the rate of coolant injection increased. At a coolant injection mass flux of $1.0\;kg/m^2s$, the dryout heat density was ${\sim}6.5\;MW/m^3$ for the 4.8 mm particle bed and ${\sim}5.6\;MW/m^3$ for the 3.2 mm particle bed. The enhancement factors of the dryout heat density were 1.6-1.8.

Heat Transfer from Rectangular Fins with a Circular Base (원형 베이스와 사각 휜 주위의 열전달 해석)

  • Yu, Seung-Hwan;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.467-472
    • /
    • 2011
  • The heat transfer over a radial heat sink, adapted for LED (light emitting diode) downlights, was experimentally and analytically investigated. We added radiation heat transfer into a previous calculation that neglected this factor. The numerical results agreed well with experimental results. Parametric studies were performed to compare the effects of the geometric parameters (fin length, fin height, ideal number of fins) and the operating parameter (heat flux) on the average heat-sink temperature from the heat-sink array. We found the fin length that maximizes the heattransfer performance. As the emissivity increased, the effect of geometric parameters on the radiation heat transfer decreased.

New Light Fiber BLU System for Large LCD Display

  • Chung, Man-Young;Park, Tong-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1398-1400
    • /
    • 2002
  • A new PLF-BLU (Plastic Light Fiber-Back Light Unit) using side glowing light fiber rods array for the 42" LCD TV display has been evelopedd. The light fibers were 14mm in diameter and 50cm long pure transparent acrylic rods of 1.49 refractive index. Fine seratees were made on the flat side of rod. extremely bright incandscent light from lamp fed into the fiber si scattered at scratches then emerges through the surface of rod. A typical PLF-BLU system consists of 24 PLFs produced side glow of brightness of 4,500cd/㎡ to 6,500cd/㎡. New PLF-BLU is proved to be a BLU of rigid, bright, no heat generation, and low power consumption, hence a prospective BLU system for very and/or ultra large size TVs. A new LED-PLF-BLU system considered to be a revolutionary to break-through of the BLU technologies has also been developed, and is decribed briefly.

  • PDF

Heat Pump System Using Heated Effluent of Thermal Power Generation Plant as a Heat Source (해수를 이용한 화력발전소 폐열회수 히트펌프 시스템)

  • Ryou, Y.S.;Kang, Y.K.;Kim, Y.H.;Jang, J.K.;Kim, J.G.;Lee, H.M.;Kang, G.C.;Nah, K.D.;Huh, T.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.190-190
    • /
    • 2011
  • In South Korea the gross generation and heated effluent of power generation plant was 259 TWh and 4.73 billion tons in 2008. And then the waste heat from power generation was 388 TWh. It shows that the efficiency of thermal power generation plant is about 40%. Therefore to reduce $CO_2$ emission from thermal power generation plant, the energy of this heated effluent must be reused to heat buildings or farm facilities. In South Korea horticultural facilities of about 25% are heated in winter season. Total area of greenhouses which are heated is about 13,000 ha. Total heat amount needed to warm greenhouse of 13,000 ha in winter season is only 3.4% of total waste heat from power generation plant. In this study a heat pump system was designed to reuse the waste heat from power generation. Especially new heat exchanger was developed to recover the thermal energy from waste water and this model considered anti-corrosion against sea water and low cost for economic feasibility. This heat recovery system was installed in mango growing greenhouse around thermal power generation plant in Seogwipo-city, Jeju Special Self-Governing Province. The result of preliminary test shows that the heating cost of about 90% is saved as compared to boiler using tax free light oil as a fuel.

  • PDF

Analysis of Temperature Reduction and Reflection Spectrum of Steel Plate according to Differential Thermal Mechanism of Solar Heat Paint (태양열 차단 도료의 차열 메카니즘에 따른 강판재의 온도저감 및 반사스펙트럼 분석)

  • Mun, Dong-Hwan;Lee, Kwang-Soo;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.37-38
    • /
    • 2017
  • In Infrared rays, which are 50% of sunlight, act as heat rays to heat buildings. Solar heat paint is widely used to protect buildings from sunlight. Solar heat coatings are used to block buildings form sunlight. Solar heat paints are classified as heat-reflective paints and heat-insulating paints according to the differential thermal mechanism. In this study, we study the thermal differential mechanism by analyzing the temperature change of the coated steel plate and the solar reflection spectrum on the surface. In this experiment, exposed steel plate, heat-reflective coated steel plate, heat-insulating coated steel plate, and general paint coated steel plate were used. As a result, when the infrared rays of 780nm ~ 1400nm were irradiated, the heat reflective paint had a temperature lower by 10 degrees than other paints. Analysis of the reflection spectrum of the paint shows that the heat paint is lower in heat than other paints because it has higher reflectance of light and absorbs much of the infrared rays.

  • PDF

An Analysis on the Spatial Patterns of Heat Wave Vulnerable Areas and Adaptive Capacity Vulnerable Areas in Seoul (서울시 폭염 취약지역의 공간적 패턴 및 적응능력 취약지역 분석)

  • Choi, Ye Seul;Kim, Jae Won;Lim, Up
    • Journal of Korea Planning Association
    • /
    • v.53 no.7
    • /
    • pp.87-107
    • /
    • 2018
  • With more than 10 million inhabitants, in particular, Seoul, the capital of Korea, has already experienced a number of severe heat wave. To alleviate the potential impacts of heat wave and the vulnerability to heat wave, policy-makers have generally considered the option of heat wave strategies containing adaptation elements. From the perspective of sustainable planning for adaptation to heat wave, the objective of this study is to identify the elements of vulnerability and assess heat wave-vulnerability at the dong level. This study also performs an exploratory investigation of the spatial pattern of vulnerable areas in Seoul to heat wave by applying exploratory spatial data analysis. Then this study attempts to select areas with the relatively highest and lowest level of adaptive capacity to heat wave based on an framework of climate change vulnerability assessment. In our analysis, the adaptive capacity is the relatively highest for Seongsan-2-dong in Mapo and the relatively lowest for Changsin-3-dong in Jongno. This study sheds additional light on the spatial patterns of heat wave-vulnerability and the relationship between adaptive capacity and heat wave.

High Efficiency Switch-Mode LED driver for Visible Light Communication System (가시광 통신 시스템을 위한 고효율 스위치모드 LED 구동회로)

  • Kang, Jung-Min;Cho, Sang-Ho;Hong, Sung-Soo;Han, Sang-Kyoo;SaKong, Suk-Chin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.358-365
    • /
    • 2011
  • Recently, the LED(Light Emitting Diode) replacing incandescent light bulbs and fluorescent light has great attentions as a most promising candidate for the next generation lighting source due to its environment-friendly characteristics, long life and excellent efficiency. Moreover, since it is a semiconductor device which can convert the electric energy to visible light at a very high speed, it can also used as a communication device. Therefore, the VLC(Visible Light Communication) using the LED can perform the near field communication and lighting function at the same time without additional expenses. However, since the switching device of the conventional LED driver for VLC is operated in the linear region, there exist several drawbacks such as a poor power conversion efficiency and serious heat generation. On the other hand, since the proposed driver is operated in the on/off switching region, it features a higher efficiency and more improved heat generation. To verify the validity of the proposed LED driver, experimental results from a prototype of 20W rated LED driver applied to 3MHz bps broadcasting audio system are given.

Work Softening Behavior of Zn-15%Al alloy (Zn-15%Al 합금의 가공연화 거동)

  • Jun, Joong-Hwan;Seong, Ki-Duk;Kim, Jeong-Min;Kim, Ki-Tae;Jung, Woon-Jae
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.1
    • /
    • pp.18-23
    • /
    • 2005
  • Effect of cold rolling on microstructural changes has been investigated for a Zn-15%Al alloy to elucidate the reason for its work softening behavior. Fully annealed microstructure of the Zn-15%Al alloy is characterized by ${\eta}$ grains and (${\eta}+{\alpha}$) lamellar colonies, where ${\eta}$ and ${\alpha}$ are Zn-rich HCP and Al-rich FCC phases, respectively. The hardness decreases continuously with increasing cold rolling degree, exhibiting work softening behavior. It is revealed that during the cold rolling, (${\eta}+{\alpha}$) lamellar colonies gradually change into equiaxed ${\eta}$ and ${\alpha}$ grains due to dynamic recrystallization at room temperature, while pre-existing ${\eta}$ grains are only deformed without recrystallization. Furthermore, cold rolling causes the precipitation of dissolved Al solutes in ${\eta}$ grains. In view of these results, change of (${\eta}+{\alpha}$) phases from lamellar to equiaxed morphology, which results in structural softness and increase in equiaxed ${\eta}/{\alpha}$ grain boundaries with higher mobility, and deterioration of solution hardening by precipitation of Al solutes from ${\eta}$ grains, are thought to contribute to the work softening of Zn-15%Al alloy.