• 제목/요약/키워드: Heat exchanger tube

검색결과 777건 처리시간 0.024초

오일 쿨러의 열전달 성능에 관한 실험적 연구 (Experimental Study on Heat Transfer Performance of Oil Cooler)

  • 조동현;임태우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2328-2333
    • /
    • 2008
  • The experimental study was carried out to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube heat exchanger with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. Mass flow rate was varied from 1.2 to $6.0\;m^3/h$ for oil and from 0.6 to $3.0\;m^3/h$ for cold water, respectively. From the experiment of shell-and-plate finned tube heat exchanger, the shell side heat transfer coefficient of heat exchanger with 9 tubes was compared with that of 13 and 19 tubes. It was found that the heat exchanger with 9 plate finned tubes showed more performance of heat transfer than that of 13 and 19 tubes.

  • PDF

열교환기용 고정형 튜브시트의 설계프로그램 개발 (Development of Design-Program of Fixed Type Tube-Sheet for Heat Exchanger)

  • 공제석;이경진;한정영;조종래;배원병
    • 소성∙가공
    • /
    • 제15권3호
    • /
    • pp.206-212
    • /
    • 2006
  • Design programs of tube-sheet for heat exchanger based on the related engineering society codes have been widely used. But it is not easy fer beginners to use the design programs. So we need to develop an easy program for design of tube-sheet for heat exchanger. This paper describes a developed design-program of tube-sheet fur heat exchanger. The developed program was coded on boiler theory and pressure vessel codes, provided by TEMA(Tubular Exchanger Manufactures Association) and ASME(American Society of Mechanical Engineers). Visual Basic, which is convenient for beginners to deal with, was used in the programming. Also a finite element analysis of tube-sheet for heat exchanger was carried to verify this developed program by using a commercial software, ANSYS. In the finite element analysis, tube and tube-sheet of heat exchanger were substituted by solid plate having equivalent properties for convenience of calculation. The thickness of tube-sheet obtained by the developed design-program was in good agreement with that of tube-sheet by FEA.

와류발생기를 사용한 직교류 열교환기의 열전달 촉진 (Heat Transfer Enhancement in Cross-flow Heat Exchanger Using Vortex Generator)

  • 유성연;권화길;이상섭;김병채;박동성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.61-66
    • /
    • 2003
  • Fouling is very serious problem in heat exchanger because it rapidly deteriorates the performance of heat exchanger. Cross-flow heat exchanger with vortex generators is developed, which enhance heat transfer and reduce fouling. In the present heat exchanger, shell and baffle are removed from the conventional shell-and-tube heat exchanger. The naphthalene sublimation technique is employed to measure the local heat transfer coefficients. The experiments are performed for single circular tube, staggered array tube bank and in-line array tube bank with and without vortex generators. Local and average Nusselt numbers of single tube and tube bank with vortex generator are investigated and compared to those of without vortex generator.

  • PDF

핀-관 열교환기의 모델링 (Modeling of Fin-Tube Heat Exchanger)

  • 박희용;이관수;박동규
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.952-961
    • /
    • 1989
  • 본 연구에서는 널리 사용되는 핀-관 직교류 열교환기의 정상 상태를 예측 하기 위하여 냉매의 상변화에 따른 유체의 물성치, 열전달계수 및 마찰계수의 변화와 관벽에서의 축방향 열전도를 고려한 모형을 세우고 이를 분석하여 열교환기의 종합적 인 특성을 규명하고자 한다.

Shell & Tube 열교환기 Shell 측 열전달 및 유동에 대한 수치해석 (NUMERICAL ANALYSIS ON THE HEAT TRANSFER AND FLOW IN THE SHELL AND TUBE HEAT EXCHANGER)

  • 이상혁;이명성;허남건
    • 한국전산유체공학회지
    • /
    • 제12권3호
    • /
    • pp.13-19
    • /
    • 2007
  • A numerical simulation on the heat transfer and flow field was carried out to improve the performance of the shell and tube heat exchanger. The steady incompressible 3-D Navier-Stokes solution is obtained with the actual operational condition and geometry of the heat exchanger. Based on this study, it is noted that the present geometry of the heat exchanger causes poor heat transfer since the air inside shell does not flow through the tube bundle, but around it. The enhancement of the heat transfer can be achieved by the variation of the design factor like the sealing strip located on the top/bottom and middle of the baffle, but it causes the increasement of the pressure drop. In this paper, the effects of the location and size of the sealing strips and flow rate through the heat exchanger on the heat transfer and pressure drop are studied.

원통다관형 열교환기의 가로막 개수에 관한 연구 (A study of number of baffle on shell and tube heat exchanger)

  • 김순영;이육형;박명관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.635-638
    • /
    • 2000
  • The propose of study analyze a TEMA(Tubular Exchanger Manufacturers Association) E shell and tube heat exchanger performance with 3, 5, 7, 9, 11 baffles and 16, 20 tubes. In this investigate measured a variation of the heat exchanger cooling capacity change within each number of baffle and tube number and determined optimal number of baffle. designs for industry applications are optimized using the analysis of test results.

  • PDF

쉘앤튜브형 열교환기의 단일 쉘 내 고온공기 열유동 특성 해석 (Analysis on Characteristics of Thermal Flow of Hot Air in Single Shell of Shell and Tube-type Heat Exchanger)

  • 양영준
    • 한국산업융합학회 논문집
    • /
    • 제26권2_2호
    • /
    • pp.255-263
    • /
    • 2023
  • The shell and tube-type heat exchangers have been frequently used in many industrial field because of its simple structure and wide operation conditions and so on. The purpose of this study is to investigate the flow characteristics in single shell of shell and tube-type heat exchanger according to velocity and temperature of hot air released from heat exchanger simulator through numerical analysis. As the results, the temperature was decreased in almost quadratic curve from top to bottom in single shell of the shell and tube-type heat exchanger. Further the changes of pressure and velocity in outlet according to change of inlet temperature were not observed. The cost for operating the shell and tube-type heat exchanger should be compared the supply cost of hot air with that of velocity in order to make a economic decision.

증기압축식 냉동장치에서 다증관 열교환기의 성능특성에 관한 실험적 연구 (An Experimental Study of the Performance Characteristics on Multiple-tube Heat Exchanger in the Vapor Compression Refrigeration System)

  • 김재돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.37-43
    • /
    • 2009
  • This paper is performed to develop a tripple-tube exchanger which can improve the system efficiency. Three different tube diameters are compacted by one body(tripple-tube) to recover waste heat from heat exchanging among the fluids. With this, the tripple-tube shows higher cooling capacity than the double-tube after comparing between those two systems. The results of this paper are basic data to design the optimum tripple-tube heat exchanger.

핀-관 열교환기의 표면특성에 따른 착상 거동에 관한 연구 (A study on the behavior of frost formation according to surface characteristics in the fin-tube heat exchanger)

  • 류수길;이관수
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.377-383
    • /
    • 1999
  • In this study, the behavior of frost formation according to surface characteristics in the fin-tube heat exchanger has been examined experimentally. The results show that the thickness of the frost which is attached to the hydrophilic heat exchanger becomes thin and the air pressure drop is smaller than that of bare aluminium heat exchanger However, the frost mass of hydrophilic heat exchanger is more than the bare one. Hence, high density frost is attached to hydrophilic heat exchanger. The sensible and latent heat flux of hydrophilic heat exchanger is bigger than that of bare one, but the increasing amount is very small and the improvement of thermal performance is also very small. The variation of fin-pitch of heat exchanger shows little influence on frost formation and hydrophilic heat exchanger loses its surface characteristics rapidly with increasing relative humidity.

  • PDF

R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구 (A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant)

  • 정규하;박윤철;오상경
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.