• Title/Summary/Keyword: Heat exchange capacity

Search Result 64, Processing Time 0.032 seconds

Continuous monitoring of the canopy gas exchange of rice and soybean based on the aerodynamic analysis of the plant canopy

  • Tanaka, Yu;Katayama, Hiroto;Kondo, Rintaro;Homma, Koki;Shiraiwa, Tatsuhiko
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.60-60
    • /
    • 2017
  • It is important to measure the gas exchange activity of the crops in canopy scale to understand the process of biomass production and yield formation. Thermal imaging of the canopy surface temperature is a powerful tool to detect the gas exchange activity of the crop canopy. The simultaneous measurement of the canopy temperature and the meteorological data enables us to calculate the canopy diffusive conductance ($g_c$) based on the heat flux model (Monteith et al. 1973, Horie et al. 2006). It is, however, difficult to realize the long-term and continuous monitoring of $g_c$ due to the occurrence of the calculation error caused by the fluctuation of the environmental condition. This is partly because the model assumption is too simple to describe the meteorological and aerodynamic conditions of the crop canopy in the field condition. Here we report the novel method of the direct measurement of the aerodynamic resistance ($r_a$) of the crop canopy, which enables us the stable and continuous measurement of the gas exchange capacity of the crop plants. The modified heat balance model shows the improved performance to quantify $g_c$ under the fluctuating meteorological condition in the field. The relationship between $g_c$ and biomass production of rice and soybean varieties is also discussed in the presentation.

  • PDF

Performance Simulation for the Optimal Design of Automotive Air-Conditioning System (자동차용 냉방시스템의 최적설계를 위한 성능시뮬레이션)

  • 김제봉;신기열;김수연;정평석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.570-580
    • /
    • 2000
  • The performance simulation of refrigeration system for the automotive vehicles was peformed, in which the refrigerant was HFC-l34a as an alternative to CFC-12. The coefficient of performance of the system for HFC-l34a was lower than that for CFC-12 operated in the same operating and design conditions. The optimal design conditions were obtained as a function of optimum capacity ratios of condenser and evaporator.

  • PDF

Exergy Analysis and Heat Exchanger Network Synthesis for Improvement of a Hydrogen Production Process: Practical Application to On-Site Hydrogen Refueling Stations (수소 생산 공정 개선을 위한 엑서지 분석과 열 교환망 합성: 분산형 수소 충전소에 대한 실용적 적용)

  • YUN, SEUNGGWAN;CHO, HYUNGTAE;KIM, MYUNGJUN;LEE, JAEWON;KIM, JUNGHWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.5
    • /
    • pp.515-524
    • /
    • 2022
  • In this study, the on-site hydrogen production process for refueling stations that were not energy-optimized was improved through exergy analysis and heat exchange network synthesis. Furthermore, the process was scaled up from 30 Nm3/h to 150 Nm3/h to improve hydrogen production capacity. Exergy analysis results show that exergy destruction in the SMR reactor and the heat exchanger accounts for 58.1 and 19.8%, respectively. Thus, the process is improved by modifying the heat exchange network to reduce the exergy loss in these units. As a result of the process simulation analysis, thermal and exergy efficiency is improved from 75.7 to 78.6% and 68.1 to 70.4%, respectively. In conclusion, it is expected to improve the process efficiency when installing on-site hydrogen refueling stations.

Effects on Performance of an Internal Heat Exchanger According to Charge Amount and Operating Condition in $CO_2$ Cooling Mode (이산화탄소 냉방운전 시 냉매충전량 및 운전조건에 따라 내부열교환기가 성능에 미치는 영향)

  • Kwak, Myoung-Seok;Cho, Hong-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • This is an experimental study on the performance characteristics of effective heat pump in the cooling mode using a single-stage compression $CO_2$ cycle with an IHX(internal heat exchanger). The performance of a single-stage compression with IHX was investigated according to charge amount and operating condition. Moreover, the performance characteristic of cooling operating was analyzed with the length of IHX. As a result, the optimum refrigerant charge amount was 2.2 kg. The optimal system COP for compressor frequency of 30, 40, 50, and 60 Hz was 3.493, 3.228, 2.978, and 2.659, respectively. Since the system with IHX can maintain large cooling capacity regardless of operating condition, the system performance doesn't reduce considerably under unfavorable condition. When the compressor frequency was 40 Hz, the COP for a system with IHX length of 3 m and 5 m was 3.361 and 3.51, respectively. By using the IHX into a $CO_2$ cooling system, the performance and reliability improves simultaneously.

Investigation and Analysis on the present state of Geothermal Source Heat Pump System Applied in Korea (지열히트펌프 시스템의 국내 적용현황 조사 및 분석)

  • Choi, Mi-Young;Ko, Myeong-Jin;Kim, Yong-Shik;Park, Jin-Chul;Rhee, Eon-Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.267-272
    • /
    • 2009
  • This study aims to investigate and analyze the present state of ground source heat pump(GSHP) system applied in Korea. It is based on the statistic from the New and Renewable Energy Center in Korea and construction results of the professional companies registered to the center. The research items were installed area, installed year, building use, ground heat exchange type and heat exchanger type of the pump. According to the result of investigation, the using GSHP system have been increasing steadily as the space heating and cooling system in a building. The capacity of this system is also becoming lager based on technical and economical feasibility analysis about the system since GSHP system first introduced in 2000.

Effect of Air-earth Heat Exchange System on Growth of Leafy Lettuce in Greenhouse (온실내 잉여에너지 이용을 위한 지중 열교환 시스템의 상추 재배 효과)

  • Paek, Yee;Jeon, Jong-gil;Yun, Nam-kyu;Kang, Geum-Choon;Lee, Si-Young
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.71-76
    • /
    • 2011
  • Earth to air heat exchangers made by iron, aluminium, copper and poly-ethylene pipe for single greenhouse heating were experimented and blowers. Earth to air heat exchanger was installed by pipelines in earth tube at 70cm depths and air blower was the heating capacity 3kW/h, As the result, Temperature difference due to temperature history of the inlet and outlet air on the various type in earth tube in greenhouse showed that air temperature at the various type in earth tube, comparison tube were make no difference respectively. Under the experimental condition, heat fluxes and heating load were showed 6,800Kcal/h, 19,699kcal/h generally yield of Lactuca Sativa cultured during days of sowing 90day in greenhouse using copper pipe was 170% incleased.

Basic Study on 250KW-class IoT Electric Heater for Ship Fuel Heating (선박연료 가열용 250KW급 판형 IoT 전기히터의 기초연구)

  • Jang, Sung-Cheol
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.63-68
    • /
    • 2021
  • Domestic electric heater manufacturers are focusing on technology development to improve the efficiency of existing products. The electric heater for ship fuel is large in size and has high difficulty in miniaturization/high efficiency, so there are not many companies that try to develop technology yet. The existing electric heater has a structure of low heating efficiency because the contact time with the heat exchange tube of the heating medium is very short because the flow path of the ship engine fuel is monotonous. Since it is manufactured in a tubular shape, the volume is very large regardless of the heating efficiency. As a result, the tubular electric heater device applied by overseas advanced companies has difficulty in maintaining and repairing because it is necessary to decompose all tubular heaters when a specific part of the inside is damaged and if the heat exchange tube is damaged, all the heat exchange tubes must be decomposed. In this study, a basic study on plate type electric heaters capable of heating 10 tons of ship engine fuel per hour and setting a maximum temperature of up to 150℃ was conducted through a 250kW capacity plate type electric heater.

Preparation and Characterization of Hydrophilic Aminated poly(styrene-ethylene-butylene-styrene) Polymer Membrane (친수성 아민화된 poly(styrene-ethylene-butylene-styrene) 고분자 분리막 제조 및 투습도 특성평가)

  • Son, Tae Yang;Kim, Ji Hyun;Park, Chi Hoon;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.336-343
    • /
    • 2017
  • These days, the quality of indoor air is a very important concept for modern people who have lived in building and is a matter of new thinking. The quality is determined by the temperature and humidity of indoor air. In addition, there is a disadvantage in that energy consumption is severe for indoor air improvement. Therefore, researches on methods to solve such problems using total heat exchange have been actively conducted. So, in this study, aminated poly(styrene-ethylene-butylene-styrene) polymers were synthesized by introducing a hydrophilic substituent, ammonium, into main chain and the properties of synthesized polymers were evaluated. The synthesis was carried out through chloromethylation and amination reactions to introduce ammonium into main chain. As a result, the water uptake and the ion exchange capacity of the synthesized polymers increased as the content of the reaction reagent solution increased. It was confirmed that the important data at the total heat exchange membrane, water vapor transmission rate also increased according to temperature, equivalent.

Development of Heating and Cooling System with New Heat Exchange Cycle for High Efficiency and Peak Power Reduction Using Real time Constant Refrigerant Pressure Control (실시간 일정압력 제어기술을 적용한 냉난방장치의 피크부하 저감과 에너지 효율 향상을 위한 시스템 개발)

  • Choi, Sun-Young;Lee, Young-Kug;Choi, Myeong-Gwang;Choi, Tae-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.53-58
    • /
    • 2015
  • Systemic heating and cooling air conditioning systems are popular in various industrial fields and even home. Recently, the rate of supply of this kind of multi-heat pump has been increased under ESCO financing supporting system. Generally the heat pumping system has a structural simplicity and easy installation benefits. and has good running efficiency under normal designed condition. But under extreme climate condition (over $+30^{\circ}C$, under $-10^{\circ}C$), this system exposes abnormal power consumption. It causes high progressive electric power rates and resultant peak power capacity of power plant. In this paper, a novel system concept of buffering refrigerant accumulator and constant pressure control system to relieve peak power load is proposed and this system's utility is verified with an prototype experimental system.

Heat Exchange Drainage Method Induced Bearing Capacity Characteristic (열유도 배수공법이 적용된 지반의 하중지지 특성)

  • Shin, Seung-min;Sin, Chun-won;Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.159-164
    • /
    • 2017
  • This paper presents the results of an investigation into the thermo-hydromechanical response of weathered granite soil. The effect of forced change temperature and relative humidity at the soil layer boundaries were monitored during heating. A series of load settlement test were performed on layers of compacted, unsatureated weathered granite soil with geosynthetic embedded at mid height before and after application of heat exchanger to the base of the soil layers. The results from this study indicated the potential for using embedded heat exchangers for the mechanical improvement of geotechnical systems incorporating weathered granite soil.