• 제목/요약/키워드: Heat exchange capacity

검색결과 65건 처리시간 0.032초

Continuous monitoring of the canopy gas exchange of rice and soybean based on the aerodynamic analysis of the plant canopy

  • Tanaka, Yu;Katayama, Hiroto;Kondo, Rintaro;Homma, Koki;Shiraiwa, Tatsuhiko
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.60-60
    • /
    • 2017
  • It is important to measure the gas exchange activity of the crops in canopy scale to understand the process of biomass production and yield formation. Thermal imaging of the canopy surface temperature is a powerful tool to detect the gas exchange activity of the crop canopy. The simultaneous measurement of the canopy temperature and the meteorological data enables us to calculate the canopy diffusive conductance ($g_c$) based on the heat flux model (Monteith et al. 1973, Horie et al. 2006). It is, however, difficult to realize the long-term and continuous monitoring of $g_c$ due to the occurrence of the calculation error caused by the fluctuation of the environmental condition. This is partly because the model assumption is too simple to describe the meteorological and aerodynamic conditions of the crop canopy in the field condition. Here we report the novel method of the direct measurement of the aerodynamic resistance ($r_a$) of the crop canopy, which enables us the stable and continuous measurement of the gas exchange capacity of the crop plants. The modified heat balance model shows the improved performance to quantify $g_c$ under the fluctuating meteorological condition in the field. The relationship between $g_c$ and biomass production of rice and soybean varieties is also discussed in the presentation.

  • PDF

자동차용 냉방시스템의 최적설계를 위한 성능시뮬레이션 (Performance Simulation for the Optimal Design of Automotive Air-Conditioning System)

  • 김제봉;신기열;김수연;정평석
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.570-580
    • /
    • 2000
  • The performance simulation of refrigeration system for the automotive vehicles was peformed, in which the refrigerant was HFC-l34a as an alternative to CFC-12. The coefficient of performance of the system for HFC-l34a was lower than that for CFC-12 operated in the same operating and design conditions. The optimal design conditions were obtained as a function of optimum capacity ratios of condenser and evaporator.

  • PDF

수소 생산 공정 개선을 위한 엑서지 분석과 열 교환망 합성: 분산형 수소 충전소에 대한 실용적 적용 (Exergy Analysis and Heat Exchanger Network Synthesis for Improvement of a Hydrogen Production Process: Practical Application to On-Site Hydrogen Refueling Stations)

  • 윤승관;조형태;김명준;이재원;김정환
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.515-524
    • /
    • 2022
  • In this study, the on-site hydrogen production process for refueling stations that were not energy-optimized was improved through exergy analysis and heat exchange network synthesis. Furthermore, the process was scaled up from 30 Nm3/h to 150 Nm3/h to improve hydrogen production capacity. Exergy analysis results show that exergy destruction in the SMR reactor and the heat exchanger accounts for 58.1 and 19.8%, respectively. Thus, the process is improved by modifying the heat exchange network to reduce the exergy loss in these units. As a result of the process simulation analysis, thermal and exergy efficiency is improved from 75.7 to 78.6% and 68.1 to 70.4%, respectively. In conclusion, it is expected to improve the process efficiency when installing on-site hydrogen refueling stations.

이산화탄소 냉방운전 시 냉매충전량 및 운전조건에 따라 내부열교환기가 성능에 미치는 영향 (Effects on Performance of an Internal Heat Exchanger According to Charge Amount and Operating Condition in $CO_2$ Cooling Mode)

  • 곽명석;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권1호
    • /
    • pp.13-20
    • /
    • 2012
  • This is an experimental study on the performance characteristics of effective heat pump in the cooling mode using a single-stage compression $CO_2$ cycle with an IHX(internal heat exchanger). The performance of a single-stage compression with IHX was investigated according to charge amount and operating condition. Moreover, the performance characteristic of cooling operating was analyzed with the length of IHX. As a result, the optimum refrigerant charge amount was 2.2 kg. The optimal system COP for compressor frequency of 30, 40, 50, and 60 Hz was 3.493, 3.228, 2.978, and 2.659, respectively. Since the system with IHX can maintain large cooling capacity regardless of operating condition, the system performance doesn't reduce considerably under unfavorable condition. When the compressor frequency was 40 Hz, the COP for a system with IHX length of 3 m and 5 m was 3.361 and 3.51, respectively. By using the IHX into a $CO_2$ cooling system, the performance and reliability improves simultaneously.

지열히트펌프 시스템의 국내 적용현황 조사 및 분석 (Investigation and Analysis on the present state of Geothermal Source Heat Pump System Applied in Korea)

  • 최미영;고명진;김용식;박진철;이언구
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.267-272
    • /
    • 2009
  • This study aims to investigate and analyze the present state of ground source heat pump(GSHP) system applied in Korea. It is based on the statistic from the New and Renewable Energy Center in Korea and construction results of the professional companies registered to the center. The research items were installed area, installed year, building use, ground heat exchange type and heat exchanger type of the pump. According to the result of investigation, the using GSHP system have been increasing steadily as the space heating and cooling system in a building. The capacity of this system is also becoming lager based on technical and economical feasibility analysis about the system since GSHP system first introduced in 2000.

온실내 잉여에너지 이용을 위한 지중 열교환 시스템의 상추 재배 효과 (Effect of Air-earth Heat Exchange System on Growth of Leafy Lettuce in Greenhouse)

  • 백이;전종길;윤남규;강금춘;이시영
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.71-76
    • /
    • 2011
  • Earth to air heat exchangers made by iron, aluminium, copper and poly-ethylene pipe for single greenhouse heating were experimented and blowers. Earth to air heat exchanger was installed by pipelines in earth tube at 70cm depths and air blower was the heating capacity 3kW/h, As the result, Temperature difference due to temperature history of the inlet and outlet air on the various type in earth tube in greenhouse showed that air temperature at the various type in earth tube, comparison tube were make no difference respectively. Under the experimental condition, heat fluxes and heating load were showed 6,800Kcal/h, 19,699kcal/h generally yield of Lactuca Sativa cultured during days of sowing 90day in greenhouse using copper pipe was 170% incleased.

액체 수소 생산을 위한 예냉 시스템의 수소 가스 예냉 온도 및 열 교환기 면적에 관한 연구 (Study on Hydrogen Gas Pre-cooling Temperature and Heat Exchanger Area of Pre-cooling System for Production of Liquid Hydrogen)

  • 배민관;하동우;노현우;우승빈;허기;서영민
    • 한국수소및신에너지학회논문집
    • /
    • 제35권3호
    • /
    • pp.290-299
    • /
    • 2024
  • In this study, a theoretical study was conducted on the pre-cooling temperature of hydrogen gas and the heat exchanger area in a small-scale liquefied hydrogen system. The small-scale liquefaction system was built and liquid hydrogen production experiments were performed. In this process, the temperature of precooled hydrogen gas was measure to be about 120 K, and then the possibility of a cause was analyzed through pressure analysis of hydrogen gas and container, and analysis of the amount of liquid hydrogen produced. It was found that some reasonable results were obtained from the theoretical approaches. Based on this theoretical approach, we aim to improve the production of liquid hydrogen by optimizing the heat exchange area according to flow rate.

선박연료 가열용 250KW급 판형 IoT 전기히터의 기초연구 (Basic Study on 250KW-class IoT Electric Heater for Ship Fuel Heating)

  • 장성철
    • 사물인터넷융복합논문지
    • /
    • 제7권3호
    • /
    • pp.63-68
    • /
    • 2021
  • 국내의 전기히터 제조업체에서는 기존 제품의 효율을 향상시키는 기술 개발에 집중하고 있다. 선박 연료용 전기히터는 그 크기가 크고 소형화/고효율화에 대한 난이도가 높아 아직까지 기술개발을 시도하는 기업은 많지 않은 실정이다. 기존의 전기히터는 선박 엔진 연료의 유동경로가 단조롭기 때문에 가열매체의 열교환 튜브와의 접촉시간이 매우 짧아 가열 효율이 낮은 구조이며, 관형으로 제작되어 있기 때문에 가열효율과 무관하게 부피가 매우 크게 제작되므로 가열장치의 설치공간을 확보해야 한다. 이로인해 해외 선진사에서 적용하고 있는 관형 전기히터 장치는 내부의 특정부분이 손상되었을때 관형 가열기를 모두 분해하여야 하고, 열교환 튜브가 손상된 경우에는 열교환 튜브를 모두 분해해야 하므로 유지와 보수에 어려움이 있다. 본 연구에서는 250kW 용량급 판형 전기히터 가열기를 통해 시간당 10ton의 선박 엔진 연료를 가열할 수 있고, 최대온도를 150℃까지 설정할 수 있는 판형 전기히터에 대한 기초연구를 수행하였다.

친수성 아민화된 poly(styrene-ethylene-butylene-styrene) 고분자 분리막 제조 및 투습도 특성평가 (Preparation and Characterization of Hydrophilic Aminated poly(styrene-ethylene-butylene-styrene) Polymer Membrane)

  • 손태양;김지현;박치훈;남상용
    • 멤브레인
    • /
    • 제27권4호
    • /
    • pp.336-343
    • /
    • 2017
  • 요즘 건물 내에서의 생활이 많아진 현대인에게 실내공기의 질은 매우 중요한 개념이고, 새롭게 생각을 해 보아야 하는 문제이다. 실내공기의 질은 실내공기의 온도, 습도 등으로 결정이 된다. 그리고 실내공기 개선을 위해서는 에너지 소비가 심하다는 단점이 있다. 그리하여, 전열교환을 이용하여 이러한 문제를 해결하려는 방법에 대한 연구가 활발히 이루어지고 있다. 따라서, 본 연구에서는 전열교환 분리막 적용을 위하여, poly(styrene-ethylene-butylene-styrene) 고분자에 친수성 치환기인 암모늄을 도입하여 아민화된 SEBS 고분자를 합성하였고, 합성고분자에 대한 특성평가를 진행하였다. 암모늄을 도입하기 위하여 클로로메틸화 반응과 아민화 반응을 통하여 합성을 진행하였다. 결과적으로 합성고분자는 반응용제의 함량이 높아질수록 함수율, 이온교환용량이 증가하였고, 전열교환 분리막에서 중요한 투습도 또한 증가함을 확인할 수 있었다.

실시간 일정압력 제어기술을 적용한 냉난방장치의 피크부하 저감과 에너지 효율 향상을 위한 시스템 개발 (Development of Heating and Cooling System with New Heat Exchange Cycle for High Efficiency and Peak Power Reduction Using Real time Constant Refrigerant Pressure Control)

  • 최선영;이영국;최명광;최태원
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.53-58
    • /
    • 2015
  • Systemic heating and cooling air conditioning systems are popular in various industrial fields and even home. Recently, the rate of supply of this kind of multi-heat pump has been increased under ESCO financing supporting system. Generally the heat pumping system has a structural simplicity and easy installation benefits. and has good running efficiency under normal designed condition. But under extreme climate condition (over $+30^{\circ}C$, under $-10^{\circ}C$), this system exposes abnormal power consumption. It causes high progressive electric power rates and resultant peak power capacity of power plant. In this paper, a novel system concept of buffering refrigerant accumulator and constant pressure control system to relieve peak power load is proposed and this system's utility is verified with an prototype experimental system.