• Title/Summary/Keyword: Heat current

Search Result 2,159, Processing Time 0.028 seconds

A Study on Bond Wire Fusing Analysis of GaN Amplifier and Selection of Current Capacity Considering Transient Current (GaN증폭기의 본드 와이어 용융단선 현상분석과 과도전류를 고려한 전류용량 선정에 대한 연구)

  • Woo-Sung, Yoo;Yeon-Su, Seok;Kyu-Hyeok, Hwang;Ki-Jun, Kim
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.537-544
    • /
    • 2022
  • This paper analyzes the occurrence and cause of bond wires fusing used in the manufacture of pulsed high power amplifiers. Recently GaN HEMT has been spotlight in the fields of electronic warfare, radar, base station and satellite communication. In order to produce the maximum output power, which is the main performance of the high-power amplifier, optimal impedance matching is required. And the material, diameter and number of bond wires must be determined in consideration of not only the rated current but also the heat generated by the transient current. In particular, it was confirmed that compound semiconductor with a wide energy band gap such as GaN trigger fusing of the bond wire due to an increase in thermal resistance when the design efficiency is low or the heat dissipation is insufficient. This data has been simulated for exothermic conditions, and it is expected to be used as a reference for applications using GaN devices as verified through IR microscope.

Investigation of 0.5 MJ superconducting energy storage system by acoustic emission method.

  • Miklyaev, S.M.;Shevchenko, S.A.;Surin, M.I.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.961-965
    • /
    • 1998
  • The rapid development of small-scale (1-10 MJ) Superconducting Magnetic Energy Storage Systems (SMES) can be explained by real perspective of practical implementation of these devices in electro power nets. However the serious problem of all high mechanically stressed superconducting coils-problem of training and degradation (decreasing) of operating current still exists. Moreover for SMES systems this problems is more dangerous because of pulsed origin of mechanical stresses-one of the major sources of local heat disturbances in superconducting coils. We investigated acoustic emission (AE) phenomenon on model and 0.5 MJ SMES coils taking into account close correlation of AE and local heat disturbances. Two-coils 0.5 MJ SMES system was developed, manufactured and tested at Russian Research Center in the frames of cooperation with Korean Electrical Engineering Company (KEPCO) [1]. The two-coil SMES operates with the stored energy transmitted between coils in the course of a single cycle with 2 seconds energy transfer time. Maximum operating current 1.55 kA corresponds to 0.5 MF in each coil. The Nb-Ti-based conductor was designed and used for SMES manufacturing. It represents transposed cable made of Nb-Ti strands in copper matrix, several cooper strands and several stainless steel strands. The coils are wound onto fiberglass cylindrical bobbins. To make AE event information more useful a real time instrumentation system was used. Two main measured and computer processed AE parameters were considered: the energy of AE events (E) and the accumulated energy of AE events (E ). Influence of current value in 0.5 MJ coils on E and E was studied. The sensors were installed onto the bobbin and the external surface of magnets. Three levels of initial current were examined: 600A, 1000A, 2450 A. An extraordinary strong dependence of the current level on E and E was observed. The specific features of AE from model coils, operated in sinusoidal vibration current changing mode were investigated. Three current frequency modes were examined: 0.012 Hz, 0.03 Hz and 0.12 Hz. In all modes maximum amplitude 1200 A was realized.

  • PDF

Fabrication of 250 m class Bi-2223/Ag HTS Tapes (250 m 급 Bi-2223/Ag 고온 초전도선재 제조)

  • Ha, H.S.;Oh, S.S.;Ha, D.W.;Jang, H.M.;Kim, S.C.;Song, K.J.;Park, C.;Kwon, Y.K.;Ryu, K.S.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.130-133
    • /
    • 2001
  • A multifilamentary Bi-2223 HTS tape for superconducting power applications was studied through the fabrication of 250-meter long tapes by the PIT(powder in tube) process. To fabricate continuous long wire, a drawing machine, a two-drum bull block and a rolled tape winding machine were developed. Especially, 250-meter long tapes were heat treated in the shape of pancake coil to reduce the heat affect zone and to achieve the high critical current. Engineering critical current density was improved through both the enhancements of critical current density by control of thermal process and the increase of filling factor by using thin Ag alloy sheath tubes less than 1.5 mm in thickness. We have made successfully 250-meter long 37 filamentary tapes with high filling factor up to 31 % employing the modified drawing and rolling technique. The critical current of 250-meter long tapes with pancake coil type was measured by transport method at self-field up to 250 gauss of center field. The measured values, based on the transport critical current at self-field, $I_{c}$ -B characteristics and magnetic field analysis, are 34 A of I$_{c}$ and 4.0 $kA/\textrm{cm}^2$ of $J_{e}$ at 250 m, 77 K, and 0 T. We also have achieved the 56 A of I$_{c}$ and 7.0 $0 kA/\textrm{cm}^2$ of$ J_{e}$ in short tapes at 77K, self-field, and 1$mutextrm{V}$/cm.

  • PDF

Effect of Turbulator on Heat/Mass Transfer for Impingement/Effusion Cooling System (분사홀에 설치된 난류촉진제에 따른 충돌/유출면에서의 열/물질전달 특성)

  • Hong, Sung-Kook;Lee, Dong-Hyun;Kim, Young-Do;Cho, Hyung-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.24-30
    • /
    • 2008
  • In order to enhance the heat/mass transfer, a turbulator has been installed at the exit of injection hole for the impingement/effusion cooling system. The local heat/mass transfer coefficients have been obtained by a naphthalene sublimation method. Experiments have been carried out at the fixed jet Reynolds number of 10,000. Two turbulators with different diameter have been used in the current study. The result presents that the turbulator leads to the increase in flow mixing and jet velocity, consequently enhancing the heat/mass transfer at a stagnation region. Further, the stagnation region is divided into four small areas with peak value. In the existence of initial crossflow, the stagnation regions move downstream and low heat/mass transfer regions are formed regardless of the installation of turbulator. However, the increased jet velocity by turbulator reduces the crossflow effect against the jet, resulting in decrease of low heat/mass transfer regions. Compared to the case without turbulator, the installation of turbulator yields $5{\sim}10%$ augmentation in averaged Sh value.

Heat transport characteristics by heat generation of electrochemical reactions in proton exchange membrane fuel cell (고분자전해질 연료전지에서 전기화학반응 열생성에 의한 열전달특성)

  • Cho, Son-Ah;Lee, Pil-Hyong;Han, Sang-Seok;Hwang, Sang-Soon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3377-3382
    • /
    • 2007
  • In proton exchange membrane fuel cell, the heat is generated at the catalyst layer as result of exothermic electrochemical reaction. This heat increases temperature of gas diffusion layer and membrane whose conductivity is very sensitive to humidity, function of temperature. So it is very important to analysis heat transfer through fuel cell to maintain temperature at specified range. In this paper numerical simulation was done including reversible, irreversible, ionic resistance, water formation loss to source term of energy equation. Results show that irreversible and water formation loss contributes mainly to energy source term and as current density increases, all of energy source terms become increased and Nusselt number is increased as results of more heat generation. Particularly irreversible loss is found to be predominant among the all energy source and water formation at cathode channel influences the temperature distribution of fuel cell greatly.

  • PDF

Analysis of Clinical Research Trends on Cold-Heat Pattern Identification in Korea - Focused on Quantitative Indicators for General People (한열변증의 국내 임상연구 동향 분석 - 일반인의 정량지표를 중심으로)

  • Yeo, Min Kyung;Lee, Young Seop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.31 no.2
    • /
    • pp.145-152
    • /
    • 2017
  • The purpose of this study was to investigate the clinical research of Cold-Heat of pattern identification(PI) focused on quantitative indicators for general people in Korea, through the review of OASIS, KISS, DBpia, NDSL database. Ten clinical researches were analyzed in this study. These research gradually started from 2004 to 2009 but there was no research after 2010. Diagnosis of Cold-Heat PI all was done through a questionnaire, 7 or most researches had not used the intervention methods. Quantitative indicators related to the Cold-Heat PI mentioned in the selected 10 researches are seven, these indicators include heart rate variability(HRV), electroencephalogram, Yangdorak, respiratory index, electrogastrography, acoustic analysis index, western health test index. Related to the HRV were 3 researches, but correlation of significant indicators was a few levels(R=0.026-0.090). So far, studies regarding at the quantitative indicators of the prior the Cold-Heat PI were few, and the results of the study showed that low statistical precision, a lack of biological basis. Refer to the current state, in the future, we expect that research of quantitative indicators of scientific evidence-based through calculated and precise research concerning Cold-Heat PI be regarded as important in Korean Medicine.

Analysis of Natural Convection Heat Transfer and Solidification of a Two-Layered Pool (2층으로 성층화된 풀 내에서의 자연대류 열전달과 고화현상에 대한 연구)

  • Kim J.;Kang K. S.;Kim S. B.;Kim H. D.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 2001
  • The natural convection heat transfer and solidification in a stratified pool are studied. The flow and heat transfer characteristics in a heat generating pool are compared between single-layered and double-layered pools. And local Nusselt number distributions on outer walls are obtained to consider thermal loads on a vessel wall. The cooling and solidification of Al₂O₃/Fe melt in a hemispherical vessel are simulated to study the mechanism of heat transfer and temperature distribution. A unstructured mesh is chosen for this study because of the non-orthogonality originated from the boundaries of double-layered pool. Interface between the layers is modeled to be fixed. With this assumption mass flux across the interface is neglected, but shear force and heat flux are considered by boundary conditions. The colocated cell-centered finite volume method is used with the Rhie-Chow interpolation to compute cell face velocity. To prevent non-physical solutions near walls in case body force is large the wall pressure is extrapolated by the way to include body force. The numerical solutions calculated by current method show that averaged downward heat flux of the double-layered pool increases compared to single-layered pool and maximum temperature occurs right below the interface of the layers.

  • PDF

Design of a Pin-Fin Structure in a Channel Considering the Heat Transfer and Pressure Drop Characteristics (열전달 및 압력강하 특성을 고려한 채널 내 핀-휜 구조물의 설계)

  • Shin, Jee-Young;Son, Young-Seok;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.459-467
    • /
    • 2006
  • Rapid development of electronic technology requires small size, high density packaging and high power in the electronic devices, which results in more heat generation. Suitable heat dissipation is required to ensure the guaranteed performance and reliable operation of the current state-of-the-art electronic equipment. The aim of the present study is to find out the forced-convective thermal-hydraulic characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices through the analysis and experiment. Various configuration of the pin-fin array is selected in order to find out the effect of spacing and diameter of the pin-fin on the heat transfer and pressure drop characteristics. Experimental results are compared with the analyses and correlations of several researchers. Finally, the design guide are provided for the required pressure drop and/or the heat transfer characteristics of the heat exchanger.

Experimental study on convective boiling heat transfer for pure refrigerants and refrigerant mixtures in a horizontal tube (순수 및 혼합냉매의 원관내 증발열전달 실험)

  • Sin, Ji-Yeong;Kim, Min-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.2
    • /
    • pp.730-740
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants (R22, R32, R134a, R125, R290, and R600a) and refrigerant mixtures (R32/Rl34a, R290/ R600a, and R32/R125) are measured experimentally and compared with Chen's correlation. The test section is a seamless stainless steel tube with inner diameter of 7.7mm and uniformly heated by applying electric current directly to the tube. Heat fluxes range from 10 to 30kW$^2$. Mass fluxes are set to 424 ~ 742kg/m$^{2}$s for R22, R32, R134a, R32/R134a, and R32/Rl25 ; 265 ~ 583kg/m$^{2}$s for R290, R600a, and R290/R600a. Heat transfer coefficients depend strongly on heat flux at a low quality region and become independent as quality increases. Convective boiling term in the Chen's correlation predicts experimental data of the pure refrigerants fairly well (relative error of 12.1% for the data of quality over 0.2). The correlation for pure substances overpredicts the heat transfer coefficients for nonazeotropic refrigerant mixtures.

The Performance Analysis of Sea Water Heat Pump applied Low GWP Refrigerants (Low GWP 냉매를 적용한 해수열 히트펌프의 성능해석)

  • Lim, Seung-Taek;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.92-97
    • /
    • 2016
  • In this study, the seawater Heat Pump System using seawater with temperature of annual domestic conditions ($0^{\circ}C$ to $25^{\circ}C$) is designed in order to compare its performance against the Heat Pump using unused heat of seawater. As a potential replacement for current refrigerants that exacerbate global warming and ozone delpetion, a Low GWP refrigerant's performance is analyzed. The basic water to water Heat Pump system is chosen and three commercial refrigerants - R134a, R410a, R32 - are used to compare against new Low GWP refrigerant R1234ze. When seawater with temperature of $25^{\circ}C$ is used, the performance change showed maximal increase in COP, 38.3%. low GWP refrigerant R1234ze, showed great performance characteristics reach to 5.242 and Existing commercial refrigerant, R134a showed only less than 0.03 performance difference against R1234ze. The study confirms notable performance of R1234ze refrigerant through simulation as environmentally friendly refrigerant for domestic seawater Heat Pump.