• Title/Summary/Keyword: Heat convection

Search Result 1,308, Processing Time 0.023 seconds

A New Natural Convection Heat Transfer Correlation for Laminar and Turbulent Film Condensation Derived from a Statistical Analysis of Existing Models and Data (기존모델과 실험자료의 통계적 분석에 의해 유도한 층류 및 난류 막응축에 대한 새로운 자연대류 열전달 관계식)

  • Chun, Moon-Hyun;Kim, Kyun-Tae
    • Nuclear Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.200-209
    • /
    • 1991
  • A new semi-empirical average heat transfer correlation applicable for both laminar and turbulent film-wise condensation on a vertical surface has been presented. Re functional form of the present correlation is based on the representative existing correlations for laminar and turbulent film flows, whereas the numerical coefficients of the present correlation have been determined by the least squares method using experimental data obtained from the open literatures. In addition, the performance of the present as well as the seven existing correlations (four for laminar and three for turbulent film flow regimes) were evaluated for their accuracy and the range of application. The result shows that for laminar film filow regimes Zazuli's and the present correlations give the samllest values of mean error, whereas for turbulent film How regimes Kirkbride and Badger's and the present correlations produce the smallest values of mean error.

  • PDF

A Study of Heat Transfer in a Horizontal Ice Storage Tube - Inward Freezing Process with Volume Expansion of Ice - (수평 원통형 빙축열조에서의 열전달에 관한 연구 - 얼음의 부피 팽창을 고려하는 내향 응고 실험 -)

  • Lee, J.Y.;Kim, Y.K.;Cho, N.C.;Kim, Y.J.;Yim, C.S.
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.3-11
    • /
    • 1995
  • Heat transfer phenomena during inward freezing process of the water in a horizontal cylinder were experimentally studied. The cooling temperature of a wall more significantly affects the timewise average temperature than the initial superheating temperature of the water. In addition, it was absolved that the timewise average temperature was influenced by the initial volume ratio of the water($V_l/V_{tot}$) at the same temperature conditons. One the other hand, the freezing speed of the upper part in the water-ice interface was quickly progressed due to natural convection. Furthermore, experimental observation showed that the frozen mass fraction($M_s/M_{tot}$) was influenced by the initial volume ratio of the water($V_l/V_{tot}$). It was noted that the frozen mass fraction for each $V_l/V_{tot}$ represented by $Ste^*$ and Fo.

  • PDF

Numerical analysis on thermal-fluidic characteristics of the magnetic fluid in a cavity using GSMAC (GSMAC법을 이용한 밀폐된 정방형관내 자성유체의 열-유동 특성에 관한 해석적 연구)

  • Seo, Jae-Hyeong;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.997-1002
    • /
    • 2013
  • The article is aiming to investigate the thermal-fluidic characteristics of magnetic fluid in a cavity using GSMAC (generalized-simplified marker and cell method). The transport equations of the magnetic fluid are including the continuity equation, momentum equation and energy equation for natural convection and Maxwell equation and magnetization equation of magnetite nano-sized particles motion. In addition, the heat transfer characteristics such as temperatures and Nusselt numbers and flow characteristics such as streamlines and isotherms of the magnetic fluid were analyzed with the intensity and direction of the magnetic fields. As a result, the thermal-fluidic characteristics of the magnetic fluid in a cavity were could be controlled by the intensity and direction of the magnetic fields.

Heat of Hydration and Thermal Crack Control for Floating Concrete Mass Foundation (부상식 매스콘크리트 기초의 수화열 관리 및 온도균열 제어)

  • Rhee, In-Kyu;Kim, Kwang-Don;Kim, Tae-Ook;Lee, Jun-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.156-164
    • /
    • 2010
  • A total of 6 stepwise constructions were made for building the floating mass concrete foundation. The optimal curing strategies and specialized construction guidelines were adoptively extracted from the 1.5m cube mock-up test prior to the main concrete work. Two different thermal crack index(TCI) calculations from current construction manual exhibit relatively low values as comparing the measured temperature data. This implies that the hydration-induced cracking could be developed in parts of concrete mass. However, the controversial phenomenons in reality were observed. No significant surface cracks are detected at the successive construction stages. Thereby, this paper raises the question regarding on the existence of characteristic length with varying size and shape of a target specimen which are missing in the current construction manual. The isothermal core area and high thermal gradient area in the edge volume should be identified and be introduced to TCI calculation for the purpose of an accuracy.

Analysis of Integration Factor Effect in Dynamic-Structure-Fluid-Heat Coupled Time Transient Staggered Integration Scheme for Morton Effect Analysis (모튼이펙트 해석을 위한 동역학-구조-유체-열전달 시간과도응답 연성해석 시차적분법에서 시상수 효과 분석)

  • Suh, Junho;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.77-86
    • /
    • 2019
  • The present study focuses on the effect of staggered integration factor (SIF) on Morton effect simulation results. The Morton effect is a synchronous rotordynamic instability problem caused by the temperature differential across the journal in fluid film bearings. Convection and conduction of heat in the thin film displaces the hot spot, which is the hottest circumferential position in the thin film, from -20 to 40 degrees ahead of the high spot, where the minimum film clearance is experienced. The temperature differential across the journal causes a bending moment and the corresponding thermal bow in the rotating frame acts like a distributed synchronous excitation in the fixed frame. This thermal bow may cause increased vibrations and continued growth of the synchronous orbit into a limit cycle. The SIF is developed assuming that the response of the rotor-lubricant-bearing dynamic system is much quicker than that of the bearing-journal thermal system, and it is defined as the ratio between the simulation time of the thermal system and the rotor-spinning period. The use of the SIF is unavoidable for efficient computing. The value of the SIF is chosen empirically by the software users as a value between 100 and 400. However, the effect of the SIF on Morton effect simulation results has not been investigated. This research produces simulation results with different values of SIF.

Effects of Network Density on Gridded Horizontal Distribution of Meteorological Variables in the Seoul Metropolitan Area (관측망 밀도가 기상 자료의 격자형 수평 분포에 미치는 영향)

  • Kang, Minsoo;Park, Moon-Soo;Chae, Jung-Hoon;Min, Jae-Sik;Chung, Boo Yeon;Han, Seong Eui
    • Atmosphere
    • /
    • v.29 no.2
    • /
    • pp.183-196
    • /
    • 2019
  • High-quality and high-resolution meteorological information is essential to reduce damages due to disastrous weather phenomena such as flash flood, strong wind, and heat/cold waves. There are many meteorological observation stations operated by Korea Meteorological Administration (KMA) in Seoul Metropolitan Area (SMA). Nonetheless, they are still not enough to represent small-scale weather phenomena like convective storm cells due to its poor resolution, especially over urban areas with high-rise buildings and complex land use. In this study, feasibilities to use additional pre-existing networks (e.g., operated by local government and private company) are tested by investigating the effects of network density on the gridded horizontal distribution of two meteorological variables (temperature and precipitation). Two heat wave event days and two precipitation events are chosen, respectively. And the automatic weather station (AWS) networks operated by KMA, local-government, and SKTechX in Incheon area are used. It is found that as network density increases, correlation coefficients between the interpolated values with a horizontal resolution of 350 m and observed data also become large. The range of correlation coefficients with respect to the network density shows large in nighttime rather than in daytime for temperature. While, the range does not depend on the time of day, but on the precipitation type and horizontal distribution of convection cells. This study suggests that temperature and precipitation sensors should be added at points with large horizontal inhomogeneity of land use or topography to represent the horizontal features with a resolution higher than 350 m.

Numerical Analysis of Laboratory Heating Experiment on Granite Specimen (화강암의 실내 가열실험에 대한 수치해석적 검토)

  • Dong-Joon, Youn;Changlun, Sun;Li, Zhuang
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.558-567
    • /
    • 2022
  • The evolution of temperature and thermal stress in a granite specimen is studied via heating experiment in the context of a high-level radioactive waste repository. A heating condition based on the decay-induced heat is applied to a cubic granite specimen to measure the temperature and stress distributions and their evolution over time. The temperature increases quickly due to heat conduction along the heated surfaces, but a significant amount of thermal energy is also lost through other surfaces due to air convection and conduction into the loading machine. A three-dimensional finite element-based model is used to numerically reproduce the experiment, and the thermo-mechanical coupling behavior and modeling conditions are validated with the comparison to the experimental results. The most crucial factors influencing the heating experiment are analyzed and summarized in this paper for future works.

An Experiment of Natural Circulated Air Flow and Heat Transfer in the Passive Containment Cooling System (격납용기 피동냉각계통내 자연순환 공기유량 및 열전달 실험연구)

  • Ryu, S.H.;Oh, S.M.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.516-525
    • /
    • 1994
  • Since the TMI and Chernobyl accidents, many passive safety features are suggested in advanced reactors in order to enhance the safety in future nuclear power plants. In order to verify the effectiveness and provide the data for detailed design of passive cooling system, in the present work, the effects of air inlet position and external condition on the natural circulated air flow rate and the natural and forced convective heat transfer coefficient have been investigated for the one-side heated closed path such as the passive containment cooling system of the Westinghouse's AP-600. A series of experiments have been peformed with the 1/26th scaled segment type test facility of the AP-600 passive containment. Under natural and forced convection, the air velocities and temperatures are measured at several points of the air flow path. The experimental result are compared with a simple one-dimensional model and it shows a good agreement.

  • PDF

Water film covering characteristic on horizontal fuel rod under impinging cooling condition

  • Penghui Zhang;Bowei Wang;Ronghua Chen;G.H. Su;Wenxi Tian;Suizheng Qiu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4329-4337
    • /
    • 2022
  • Jet impinging device is designed for decay heat removal on horizontal fuel rods in a low temperature heating reactor. An experimental system with a fuel rod simulator is established and experiments are performed to evaluate water film covering capacity, within 0.0287-0.0444 kg/ms mass flow rate, 0-164.1 kW/m2 heating flux and 13.8-91.4℃ feeding water temperature. An effective method to obtain the film coverage rate by infrared equipment is proposed. Water film flowing patterns are recoded and the film coverage rates at different circumference angles are measured. It is found the film coverage rate decreases with heating flux during single-phase convection, while increases after onset of nucleate boiling. Besides, film coverage rate is found affected by Marangoni effect and film accelerating effect, and surface wetting is significantly facilitated by bubble behavior. Based on the observed phenomenon and physical mechanism, dry-out depth and initial dry-out rate are proposed to evaluate film covering potential on a heating surface. A model to predict film coverage rate is proposed based on the data. The findings would have reliable guide and important implications for further evaluation and design of decay heat removal system of new reactors, and could be helpful for passive containment cooling research.

A Study on the Effect of Evaporation of Liquid Hydrogen Tank Related to Horizontal Sinewave (액화수소 저장탱크의 수평요동이 증발 특성에 미치는 영향에 대한 연구)

  • SEUNG JUN OH;JUN YEONG KWON;JEONG HWAN YOON
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.2
    • /
    • pp.155-161
    • /
    • 2023
  • Recently, a study on alternative and renewable energy is being conducted due to energy depletion and environmental problems. In particular, a hydrogen has the advantage of converting and storing the remaining energy into water-electrolyzed hydrogen through renewable energy generation. In general, due to reasons such as insulation problems, a study on high-pressure hydrogen storage tanks and related parts has recently been conducted. However, in the case of liquid hydrogen, the volume can be reduced by about 800 times or more compared to high-pressure hydrogen gas, so the study on this is needed as a technology that can increase energy density. In this study, the evaporation characteristics were analyzed under fixed heat flux conditions for liquid hydrogen storage tanks and the change in thermal stratification according to sloshing was analyzed. The heat flux condition was fixed at 250 W/m2 and the horizontal resonance frequency of the primary mode was applied to the storage tank. As a result, it was confirmed that the thermal stratification phenomenon decreased compared to the case where the slashing was not present due to forced convection when the slashing was present.