• Title/Summary/Keyword: Heat convection

Search Result 1,308, Processing Time 0.024 seconds

Evaluation of New Design Concepts for Steam Generators in Sodium Cooled Liquid Metal Reactors

  • Kim, Seong-O.;Sim Yoonsub;Kim, Eui-kwang.;Myung-Hwan.Wi;Han, Dohee.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.121-132
    • /
    • 2003
  • To reduce the construction cost and enhance the safety of sodium cooled liquid metal reactors, various kinds of new design concepts were evaluated using the KALIMER operation condition. The required equipment sizes were set for plant electricity output to be similar to that of KALIMER. The evaluations were made focusing on the plant performance and implementation practicality. Each design concept was evaluated for the concept itself and design impacts to interfacing systems. Through the evaluation of the concepts, it was found that the most favorable design concept is the integrated steam generator with forced convection using lead bismuth as the intermediate heat transfer fluid between the primary sodium tube and feed water/steam tube in the steam generator.

An approach to the coupled dynamics of small lead cooled fast reactors

  • Zarei, M.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1272-1278
    • /
    • 2019
  • A lumped kinetic modeling platform is developed to investigate the coupled nuclear/thermo-fluid features of the closed natural circulation loop in a low power lead cooled fast reactor. This coolant material serves a reliable choice with noticeable thermo-physical safety characteristics in terms of natural convection. Boussienesq approximation is resorted to appropriately reduce the governing partial differential equations (PDEs) for the fluid flow into a set of ordinary differential equations (ODEs). As a main contributing step, the coolant circulation speed is accordingly correlated to the loop operational power and temperature levels. Further temporal analysis and control synthesis activities may thus be carried out within a more consistent state space framework. Nyquist stability criterion is thereafter employed to carry out a sensitivity analysis for the system stability at various power and heat sink temperature levels and results confirm a widely stable natural circulation loop.

Sensitivity analysis of thermal-hydraulic parameters to study the corrosion intensity in nuclear power plant steam generators

  • Tashakor, S.;Afsari, A.;Hashemi-Tilehnoee, M.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.394-401
    • /
    • 2019
  • The failure of steam generators (SGs) due to corrosion is one of the most important problems in power plants. Impurities usually accumulate in the hot sides of SG and form deposits on the SG surfaces. In this paper, the sensitivity analysis of the accumulation of water impurities in the heat exchangers of nuclear power plants is presented. The convection-diffusion equation of the liquid phase on the heated surfaces is derived and then solved by the finite volume method. Also, the effects of the thermal-hydraulic parameters in the form of dimensionless numbers, such as $Pe_q$, $Pe_u$, $k_q$(relative solubility of impurity between the steam and water) on the impurities concentration are studied.

Performance Verification of Curing Method in Cold-Weather with Using Energy Saving Electronic Heater for achieving Korean Carbon Neutra (탄소중립 확보를 위한 친환경 동절기 대체 열원 성능 검증)

  • Jo, Man-Ki;Kim, Sang-Kyun;Hong, Seong-Min;Park, Jong-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.192-193
    • /
    • 2021
  • Recently, the need to strengthen the Air Environment Conservation Act and secure alternative heat sources during the winter by carbon neutrality policies has been raised. Accordingly, winter construction, which has safety and quality measures, is emerging as an essential factor. It is believed that eco-friendly tropical type electric hot air heaters will be able to solve most of the problems of winter construction at construction sites, especially prevention of suffocation and fire accidents. In addition, as a result of on-site performance verification, it has secured more than the same performance as the existing curing method, and the curing technology can create an eco-friendly and pleasant working environment while considering safety and construction.

  • PDF

Energy effects on MHD flow of Eyring's nanofluid containing motile microorganism

  • Sharif, Humaira;Naeem, Muhammad N.;Khadimallah, Mohamed A.;Ayed, Hamdi;Bouzgarrou, Souhail Mohamed;Al Naim, Abdullah F.;Hussain, Sajjad;Hussain, Muzamal;Iqbal, Zafar;Tounsi, Abdelouahed
    • Advances in concrete construction
    • /
    • v.10 no.4
    • /
    • pp.357-367
    • /
    • 2020
  • The impulse of this paper is to examine the influence of unsteady flow comprising of Eyring-Powell nanofluid over a stretched surface. This work aims to explore efficient transfer of heat in Eyring-Powell nanofluid with bio-convection. Nanofluids possess significant features that have aroused various investigators because of their utilization in industrial and nanotechnology. The influence of including motile microorganism is to stabilize the nanoparticle suspensions develop by the mixed influence of magnetic field and buoyancy force. This research paper reveals the detailed information about the linearly compressed Magnetohydrodynamics boundary layer flux of two dimensional Eyring-Powell nanofluid through disposed surface area due to the existence of microorganism with inclusion the influence of non- linear thermal radiation, energy activation and bio-convection. The liquid is likely to allow conduction and thickness of the liquid is supposed to show variation exponentially. By using appropriate similarity type transforms, the nonlinear PDE's are converted into dimensionless ODE's. The results of ODE's are finally concluded by employing (HAM) Homotopy Analysis approach. The influence of relevant parameters on concentration, temperature, velocity and motile microorganism density are studied by the use of graphs and tables. We acquire skin friction, local Nusselt and motil microorganism number for various parameters.

Numerical Analysis of Natural Convection from an Inclined Ice Flat Plate Immersed in cold Water Near Its Density Maximum (최대밀도점 부근의 물속에 잠겨있는 경사진 얼음평판에 의한 자연대류의 수치해석)

  • 유갑종;추홍록
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2136-2149
    • /
    • 1992
  • The natural convection from an inclined ice flat plate immersed in cold water near its density maximum is studied numerically. Finite difference analysis has been performed for the heat and momentum transfer with respect to various inclined angles and ambient water temperatures. The results of the analysis are presented for ambient water temperatures, 1.0deg. C. leq. T/sub .inf./.leq. 15.0deg. C and the inclined anales from 0deg to 60deg. They include velocity profiles, temperature profiles, melting velocities, and mean Nusselt numbers for entire flow fields, Generally, in the range of 0deg. C .leq.theta. .leq. 60.deg. C, the results show three distinct flow regimes, In the range of 1.0 deg. C .leq. T/sub .inf./ .leq. 4.6 .deg. C, the greatest mean Nuselt number exists about 3.0deg. C. In the range of 5.7deg. C .leq. T/sub .inf./ .leq. 15.0deg. C, mean Nuselt number increases as ambient water temperature increases. Also, the mean Nuselt number decreases as the inclined angle increases. This theoretical results are compared with previous experimental ones and multiple steady state ones.

Development of equipment for tumor cauterization

  • Hoshino, Hirokazu;Ochiai, Makoto;Sakasegawa, Aya;Hayakawa, Yoshinori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.474-477
    • /
    • 2002
  • Equipment to cauterize tumors by an electrically heated Kanthal wire is under development. The wire( alloy of iron, chromium and Aluminum) keeps sufficient strength up to 1400 degrees in Celsius. Although AC 50Hz current source is used in the prototype experiment, RF current will be used in future. The diameter of the Kanthal wire was 0.3 mm which was connected to Kanthal wire of 0.8 mm. The thicker wire was used as a leading wire. The possibility of application of the heating wire in combination with an ultrasound endoscope was determined, where ultrasound endoscope is to be used to monitor the location on the wire and an extent of a tumor in digestive organs. This procedure requires the wire to be applied inside ultrasound transmitting media. First, the wire was applied in the degassed water in which a chicken liver sample was submerged. The wire, however, burned out in water soon after it became red-hot at 12 A. The reason is that large current is required for the wire to become red-hot due to strong convection. Starch paste of 3 weight percent was employed instead of water. This made the wire red-hot approximately at 6 A, showing the increased viscosity of the starch decreased the convection and the wire was cover by the steam. The liver sample was cauterized successively, while the location of the wire and the liver was monitored by an ultrasound diagnosis equipment outside the plastic vessel of the starch paste.

  • PDF

A Numerical Study on the Natural Convection from Two Isothermal Square Beams Attached to an Vertical Adiabatic Plate (수직단열판에 부착된 2개의 등온 사각비임에서의 자연대류 열전달에 관한 수치 해석)

  • Park, Jae-Lim;Bae, Dae-Sok;Kwon, Sun-Sok
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.63-69
    • /
    • 1991
  • A Steady laminar natural convection heat transfer from two isothermal square beams attached to a vertical adiabatic plate has been studied numerically. The results have been obtained for dimensionless beam spacings, $0.5{\le}D/L{\le}3.0$, and for Gr=5000-10000 at ${\phi}_2/{\phi}_1=1.0$. 1. The local Nusselt number from the beam surface is increased with the dimension-less beam spacing D/L. but that of the downward surface of the lower beam is almost same as the D/L increases. And, the local Nusselt number from the upward surface of a lower beam is greatly increased with D/L. 2. The beam spacings of the maximum mean Nusselt number for the downward surface of an upper beam and the upward surface of a lower beam occur at. D/L =2.6 and 2.0 respectively. 3. The beam spacing for the maximum total mean Nusselt number occurs at D/L = 2.6.

  • PDF

An Experimental Study on Natural Convection from a Conducting Tube with Two Axial Fins to a Surrounding Cylinder (두개의 축방향핀을 가진 전도관과 원통사이의 자연대류에 관한 실험적 연구)

  • Ahn, C.R.;Chung, T.H;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.26-33
    • /
    • 1991
  • An experimental study has been performed on the heat transfer by the natural convection from a conducting tube with two axial fins to a surrounding cylinder. In case of vertical fins, the maximum local Nusselt number of conducting tube appears at ${\theta}{\fallingdotseq}145^{\circ}$ and that of outer cylinder appears at ${\theta}=0^{\circ}$, for $l_F=0.3$. In case of horizontal fins, the maximum local Nusselt number of conducting tube appears at ${\theta}=180^{\circ}$ and that of outer cylinder appears at ${\theta}=0^{\circ}$. The local Nusselt number of the upper fin and the downward fin shows negative values for $l_F=1.0$. The local Nusselt number of the lower fin and the downward fin shows higher values than that of the upper fin and the upward fin. The mean Nusselt number of conducting tube in case of vertical fins are increased in order of $l_F=0.6$, 0.3, 1.0 and 0.0, but in case of horizontal fins, in order of $l_F=1.0$, 0.6, 0.3, and 0.0. The mean Nusselt number of outer cylinder in case of vertical fins are increased in order of $l_F=1.0$, 0.0, 0.3 and 0.6, but in case of horizontal fins, in order of $l_F=0.6$, 1.0, 0.3, and 0.0.

  • PDF

Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer (변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구)

  • Kim, Kuk-Kyeom;Suh, Yong Kweon;Kang, Sangmo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.449-455
    • /
    • 2015
  • Owing to the trend of an increase in capacity and high-efficiency requirement, the life and reliability of power transformer depend significantly on the amount of heat generation per unit volume and the degradation of insulation oil. These problems can be solved by enhancing the cooling performance of the radiator. The purpose of this study was to find a suitable position of fans for a better cooling effect given by the forced-convection of air in an ONAF (Oil Natural Air Forced) type transformer. In the simulation, commercial software was used for flow analysis, and the cooling passage of the oil was simplified to shorten the time taken for computation. With the diameter of the fan fixed at a constant value, the analysis was performed only by changing the position of the fans. As a result, a vertical position change of the fans does not affect the cooling performance significantly. However, the temperature drop given by the fans positioned on the front region of the transformer is larger than that on the rear region.