• Title/Summary/Keyword: Heat and Cold

검색결과 1,965건 처리시간 0.037초

냉온 부하에 따른 요골동맥 맥파의 변화 특성을 파악하기 위한 무작위 배정·2×2교차설계 탐색적 임상시험계획서 개발 (Development of Clinical Protocol for Acquisition of Change of Radial Pulse Wave Signal in the Cold-Heat Intervention: Explanatory, Randomized, 2×2 cross-over design)

  • 유하나;김지혜;구본초;김현호;전영주
    • 대한한의진단학회지
    • /
    • 제19권2호
    • /
    • pp.91-100
    • /
    • 2015
  • Objectives The aim of this study is to develop a structured clinical protocol related with acquisition of radial pulse wave in the randomized, $2{\times}2$ cross-over design, and cold-heat intervention trial for a pilot and preliminary study. Methods The protocol was contrived based on wide ranging literature searches for cold-heat intervention experiments and radial pulse diagnoses. Results Sample size of 60 subjects was calculated based on an effect size derived from the previous study designed to detect the pre-post cold-heat differences in the radial pulse. Each subjects will be randomly assigned to the cold (first) to heat (last) group (n=30) or heat (first) to cold (last) group (n=30). All subjects will fill out a case report form and questionnaires related with pattern identification, dietary patterns, sleep quality, and physical activity will be surveyed and used as a secondary outcomes. Safety assessment will be reported at the final stage. Conclusions This protocol will provide an additional reference to future studies related with observation of radial pulse during any interventions and also expect to be used as a guideline for acquisition of reliable radial pulse wave data.

Study on Heat Transfer Characteristics according to Flowing Particles in a Cold Water Tube

  • Park, Ki-Won;Kim, Myoung-Jun;Jung, Sung-Chan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.243-251
    • /
    • 2007
  • This experiment was conducted to investigate the effect of particles on the heat transfer characteristics of fluids flowing in a cold water tube. Plastic beads with 3 different sizes were used as flowing particles with cold water. An experimental test section was composed of concentric double tubes having diameters of 25mm for the inner tube and 50mm for the outer tube. The materials for the inner and outer tubes are copper and PVC respectively. It was found that the particles enhanced the heat transfer coefficient by random and vortex motion in the fluid. Hence the heat transfer coefficients for the fluid with 2mm, 5mm and $2{\times}6mm$ particles were $7%{\sim}37%$ higher than the fluid without the particles.

로봇 냉각을 위한 수냉식 냉각판의 성능 평가 (Performance Test of Liquid Cooling Type Cold Plates for Robot Cooling)

  • 이석원;강상우;황규대;김서영;리광훈
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.189-196
    • /
    • 2008
  • The increase of system weight due to installation of cooling devices adds electrical and mechanical loads of humanoid robot, and in return, results in much heat. Therefore, the weight of cooling system is a critical issue for robot cooling. In this study, we propose non-metallic cold plates to deal with such problems. We compare thermal performances between one metallic cold plate and five different types of non-metallic cold plates. A metallic cold plate is totally made of copper. Five non-metallic PC(polycarbonate) cold plates, which are designed to reduce the overall weight of robot cooling system, are composed of a polycarbonate cover with different types of base plate. The overall heat transfer coefficients per unit mass and thermal resistances are obtained for the cold plates. The metallic cold plate shows the best thermal performance. It is interesting to note that the PC cold plate with an aluminum base plate with 18 channels shows the best overall heat transfer coefficient per unit mass. Most polycarbonate cold plates display fairly comparable thermal performance with more reduced system weight compared to the metallic cold plate.

퇴행성 슬관절염 환자의 한열 성향에 따른 한약 제제의 유효성과 안전성 비교 (Efficacy and Safety of Herb Medication According to Cold-heat Tendency of Knee Osteoarthritis Patients)

  • 송지연;김민정;성원석;김필군;구본혁;곽현영;김지혜;김동혁;박연철;서병관;백용현;최도영;이재동;박동석
    • Journal of Acupuncture Research
    • /
    • 제29권5호
    • /
    • pp.97-108
    • /
    • 2012
  • Objectives : To demonstrate the importance of syndrome differentiation in clinical research of herb medication, through the comparative study on efficacy and safety of herb medication according to cold-heat tendency of OA knee patients. Methods : During December 2010 to July 2011, 138 knee OA patients were randomly assigned to WIN-34B 600mg(300mg, b.i.d.), 1,200mg(600mg, b.i.d.) and placebo b.i.d. for 8 weeks. Patient were re-classified into cold-heat tendency group according to cold-heat questionnaires. To investigate efficacy and safety, we assessed the 100mm pain VAS at baseline and 8 weeks later, and we monitored adverse event of patients during treatment period. Results : 1. Efficacy study : In WIN-34B 1,200mg group, VAS mean changes of heat tendency group showed slightly increase than those of cold tendency, but no significant difference within two groups. In heat tendency group, WIN-34B 1,200mg group showed a significant decrease of VAS compared to placebo group. but there were no significant difference in cold tendency group. 2. Safety study; In WIN-34B 600mg group, incidence of adverse events of cold tendency group was higher than those of heat tendency, but not in WIN-34B 1,200mg group. Conclusions : This study suggests that WIN-34B tend to have more efficacy in heat tendency-knee OA patients and WIN-34B is safe drug relatively, regardless of cold-heat tendency. In further clinical research on efficacy and safety of WIN-34B, stratification using syndrome differentiation is required.

Effect of Twisted - Tape Tubulators on Heat Transfer and Flow Friction inside a Double Pipe Heat Exchanger

  • Phitakwinai, Sutida;Nilnont, Wanich;Thawichsri, Kosart
    • International Journal of Advanced Culture Technology
    • /
    • 제3권2호
    • /
    • pp.124-131
    • /
    • 2015
  • Computational fluid dynamics (CFD) has been employed for the Heat exchanger efficiency of a counter flow heat exchanger. The Heat exchanger efficiency has been assessed by considering the computed Nusselt number and flow friction characteristics in the double pipes heat exchanger equipped with two types twisted-tapes: (1) single clockwise direction and (2) alternate clockwise and counterclockwise direction. Cold and hot water are used as working fluids in shell and tube side, respectively. Hot and cold water inlet mass flow rates ranging are between 0.04 and 0.25 kg/s, and 0.166 kg/s, respectively. The inlet hot and cold water temperatures are 54 and $30^{\circ}C$, respectively. The results obtained from the tube with twisted-tapes insert are compared with plain tube. Nusselt number and friction factor obtained by CFD simulations were compared with correlations available in the literature. The numerical results were found in good agreement with the results reported in literature.

발포금속의 열전달 특성에 관한 실험적 연구 (Study on the Heat Transfer Characteristic of Metallic Foam)

  • 김필환;김미화;김영진;정효민;정한식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.618-623
    • /
    • 2008
  • To enhancement heat transfer performance, the metallic foam as heat exchanger was studied rapidly. This was attributed to its high surface area to volume ratio as well as intensive flow mixing by tortuous flow passages. So the experimental study about the heat transfer characteristic of metallic foam is presented in this paper. The material in this experiment was used as FeCrAl which has density of 10 ppi, 20 ppi and 30 ppi respectively. And the results show the heat transfer is rise with permeability Reynolds number increase and the pressure drop metallic foam was increased with the ppi increase.

  • PDF

저온축열용 포접화합물에 냉각특성에 관한 실험적 연구 (A study on cooling characteristics of clathrate compound for cold storage applications)

  • 한영옥;김진흥
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.205-214
    • /
    • 1999
  • The objective of this paper is to investigate the thermal properties of TMA clathrate compound applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are performed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of density, temperature of heat source and charging quantity in TMA clathrate compound. The results are summarized as follows:1) $-15^{\circ}C$ is not proper as the temperature of heat source because the temperature of subcooling is above $8.3^{\circ}C$ 2) temperature of phase change is dropped as the temperature of heat source is lower, 3) the effect of subcooling suppression with about 8$^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 26, 27, and 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 26 and 30wt%. Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$. Thus, it is concluded that TMA clathrate compound has enough thermal properties as the cold storage medium for building air-conditioning.

  • PDF

신문혈(神門穴) 자극(刺戟)과 한열성향(寒熱性向)의 교호작용(交互作用)이 심박변이도(心博變移度)에 미치는 영향(影響) (A Study on the Effect of Interaction between Acupuncture at Shinmun(HT7) and Subject's Cold or Heat Tendency on Heart Rate Variability)

  • 김동훈;양동훈;김은정;남동우;박연철;박영재;이상철;박영배
    • Journal of Acupuncture Research
    • /
    • 제23권1호
    • /
    • pp.25-38
    • /
    • 2006
  • Objectives : Acupuncture has been widely used in oriental medicine. The aim of this research is to study how does the interaction between reinforcement-reduction by twirling nine and six and subject's cold or heat tendency effect on Heart Rate Variability. Methods : We divided our subjects into 3 groups at random and classified subjects by their cold or heat tendency using questionnaire for cold-heat patternization. Group 1 is acupuncture at shinmun(HT7) reinforcement group, 2 is acupuncture at shinmun(HT7) reduction group, 3 in acupuncture at hapkok(LI4) group. According to their group, we acupunctured. Before and after acupuncture Heart Rate Variability raw data were measured during 5 minutes. LF, HF, LF norm HF norm were calculated. We analyzed these data using 3-way repeated ANOVA, Paired student T-Test. Results : 3-way repeated ANOVA showed significant interaction among LF, each group and subject's cold heat tendency(p<0.05). Paired student T-Test showed significant differences between before and after acupuncture at shinmun(HT7) reinforcement method in cold tendency men and acupuncture at shinmun(HT7) reduction method in heat tendency men(p<0.05). Conclusion : These results suggest that acupuncture at Shinmun(HT7) has an effect on declining sympathetic nerve function and has an effect on stabilizing mind through Interaction between reinforcement-reduction by twirling nine and six and subject's cold or heat tendency. We propose that more prudent care is needed about subject's cold or heat tendency and acupuncture technique of reinforcement-reduction to achieve the most suitable treatment effect.

  • PDF

"상한론(傷寒論)"과 "온병조변(溫病條辨)"의 병인병기론적 비교 연구 (Comparative Study on Etiological Cause, Pathogenesis Mechanism of "Shanghanlun" and "Wenbingtiaobian")

  • 박미선;김영목
    • 동의생리병리학회지
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2013
  • We can understand "Shanghanlun(傷寒論)" and "Wenbingtiaobian(溫病條辨)" which are major books on externally contracted diseases well by making a comparative study of their similarities and differences. After studying etiological causes and characteristics of disease, disease pattern, syndrome differentiation, transmutation rules, following conclusions are derived. While cold is an etiological cause of Cold damage and harms Yang qi, heat is an etiological cause of Warm disease and harms Yin qi. Cold damage and Warm disease have something in common in the respect of damage to fluid and humor and Yang qi. Exuberant heat symptom of Yang brightness disease and lesser yin heat transformation pattern have similar damage to fluid and humor as Warm disease does. Warm disease can reach qi collapse syndrome through damage to Yang qi following fluid and humor damage. In the respect of water qi, as Cold damage makes water-dampness retain easily due to cold congealing, dampness-draining diuretic medicinal and warm yang medicinal are used together. As warm disease damages fluid and humor, yin-tonifying medicinal is used and dampness-draining diuretic medicinal can be used in the case of Warm disease with dampness. In the respect of disease pattern, cold syndromes arise mostly by Cold damage except heat syndrome of grater yang disease, chest bind syndrome, stuffiness syndrome, reverting yin disease and yang brightness disease. Warm disease is classified as pure heat syndrome and heat syndrome with bowel excess, damage to yin, qi collapse or damage to blood.

갱년기 증상을 호소하는 여성들의 적외선 체열 영상 유형에 대한 연구 (A Study on the D.I.T.I Patterns of Climacteric Patients)

  • 허자경;이창훈;이경섭
    • 대한한방부인과학회지
    • /
    • 제22권3호
    • /
    • pp.143-151
    • /
    • 2009
  • Purpose: Among many symptoms that the climacteric patients complain of, the major symptom is heat and cold sensation of body in various pattern. So, we are intended to study patterns of climacteric patients by using D.I.T.I. Methods: We studied 55 patients visiting OO Oriental Hospital from 1st January 2008 to 31th December 2008. The patients were distributed one of patterns by inspecting D.I.T.I. And we investigated the temperature of the region of body in 5 groups. Results: There are five groups in D.I.T.I. Those are heat sensation of face pattern, heat sensation of chest pattern, cold sensation of hand & foot pattern, heat sensation of hand pattern and cold sensation of lower abdomen pattern. 22 subjects are in heat sensation of face group. 12 subjects are in heat sensation of chest group. 12 subjects are in heat sensation of hand group. 6 subjects are in cold sensation of lower abdomen group. 3 subjects are in cold sensation of hand & foot group. Conclusion: 5 patterns of D.I.T.I is showed in climacteric patients. To help oriental medical diagnosis, further studies are needed.