• Title/Summary/Keyword: Heat Waves

Search Result 293, Processing Time 0.035 seconds

Use of Guided Waves for Monitoring Material Conditions in Fossil-Fuel Power Plants (판파를 이용한 화력 발전 설비의 물성 평가)

  • Cho, Youn-Ho;Jung, Kyung-Sik;Lee, Jae-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.695-700
    • /
    • 2010
  • Material properties of the lock plate, which covers the gas-turbine blade, are studied using ultrasonic guided waves. The lock plate is a crucial part of a gas-turbine power plant. The wave velocity and attenuation coefficient are measured to investigate the changes in the material properties under three heat-treatment conditions. Compared to the destructive mechanical tests, the material characterization of Inconel X-750 can be performed more efficiently and nondestructively by using ultrasonic guided waves; this characterization helps identify the changes occurring in its elastic moduli and Poisson's ratio under different heat-treatment conditions. The wave velocity and hardness of Inconel X-750 are proportional to each other. This nondestructive technique for the measurement of material properties can be widely used in various industries to avoid catastrophic failure. It is also expected that the guided-wave technique can be applied as a new cost- and time-saving inspection tool for longer and wider inspection ranges.

Analysis of Relationship between the Spatial Characteristics of the Elderly Population Distribution and Heat Wave based on GIS - focused on Changwon City - (GIS 기반 노인인구 분포지역의 공간적 특성과 폭염의 관계 분석 - 창원시를 대상으로 -)

  • SONG, Bong-Geun;PARK, Kyung-Hun;KIM, Gyeong-Ah;KIM, Seoung-Hyeon;Park, Geon-Ung;MUN, Han-Sol
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.3
    • /
    • pp.68-84
    • /
    • 2020
  • This study analyzed the relationship between spatial characteristics and heat waves in the distribution area of the elderly population in Changwon, Gyeongsangnam-do. For analysis, the Statistics Census data, the Ministry of Environment land cover, Landsat 8 surface temperature, and the Meteorological Agency's heat wave days data were used. The spatial characteristics of the distribution of the elderly population was classified into 5 types through K-mean cluster analysis considering the land use types. The characteristics of the elderly population by spatial type were higher in the urbanized type(cluster-3), but the proportion of the elderly population was higher in the agricultural and forest area types(cluster-1, cluster-2). In the characteristics of the surface temperature and the heat wave days, the surface temperature was the highest in the urban area, but heat wave days were the highest in the rural area. As a result of analyzing the heat wave characteristics according to the spatial type of the distribution area of elderly population, cluster-2 with the largest area in agricultural areas was highest at 15.95 days, and cluster-3 with a large area in urbanized types was the lowest at 9.41 days and 9.18 days. In other words, the elderly population living in rural areas is more exposed to heat waves than the elderly population living in urban areas, and the damage is expected to increase. The results of this study could be used as basic data to prepare various policy measures for effective management and prevention of vulnerable areas in summer.

Assessment of Surface Temperature Mitigation Effects of Wetlands During Heat and Cold Waves Using Daytime and Nighttime MODIS Land Surface Temperature (Terra/Aqua MODIS LST를 이용한 폭염 및 한파기간 동안 습지의 지면온도 완화효과 분석)

  • Chung, Jeehun;Lee, Yonggwan;Kim, Seongjoon
    • Journal of Wetlands Research
    • /
    • v.21 no.spc
    • /
    • pp.123-133
    • /
    • 2019
  • This study analyzed the surface temperature mitigation effect of wetlands during cold waves (below -12℃ from January to February) and heat waves (above 33℃ from July to August) in 2018. We used Terra/Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) Daytime and Nighttime Land Surface Temperature (LST) product, and the maximum and minimum air temperature observed at 86 stations of Korea Meteorological Administration (KMA). For the cold wave analysis, the LST of Terra MODIS nighttime was the highest at forest area with -12.7℃, followed by upland crop and wetland areas of -12.9℃ and -13.0℃ respectively. The urban area showed the lowest value of -14.4℃. During the heat wave, the urban area was the highest with + 34.6℃ in Aqua MODIS LST daytime. The wetland area was + 33.0℃ showing - 1.6℃ decrease comparing with urban area.

Simulation of Heat Health Alert System Using Meteorological Data Observed by Automatic Weather Systems in Seoul, Korea

  • Kim, Ji-Young;Kim, Jung-Ok;Park, Seung-Yong;Yu, Ki-Yun
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.134-137
    • /
    • 2007
  • In this paper the heat health alert system, which is operated this year by way of showing an example, is a simulator linked to the Geographic Information System (GIS), and it uses meteorological data that are observed at Automatic Weather Systems (AWSs) in Seoul, Korea. Simulation results show that it is possible to use meteorological data observed by AWSs when the Korea Meteorological Administration (KMA) has issued alerting the public to the threat of heat waves, and to connect meteorological data to spatial data when the KMA offers local forecasts and weather-related information. However, most AWSs that were installed to manage urban disasters do not measure humidity, so general humidity is used in all districts. Therefore, to issue heat wave warnings about different localities on a small scale, we will study how to complement this problem and to examine the accuracy of data observed at AWS in the future.

  • PDF

Heat and mass transfer in laminar-wavy film (층류-파동 액막의 열 및 물질전달)

  • 김병주;김정헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 1998
  • Falling film absorption process is an important problem in application such as absorption chillers. The presence of waves on the film affects the absorption process significantly. In the present study the characteristics of heat and mass transfer in laminar-wavy falling film were studied numerically. The wavy flow behavior was incorporated in the energy and diffusion equation. The numerical solution indicated that the interfacial wave increased the transfer rates remarkably. Interfacial shear stress and wave frequency seemed to be the dominant factors on the film Nusselt number and Sherwood number in the wavy film. A comparison of the transfer rates of the wavy film to that of the smooth film showed that the mass transfer rate could be increased by more than 50%.

  • PDF

A Numerical Study on Characteristics of Unsteady Flows Caused by Heat Addition in a Convergent-Divergent Duct (축소-확대 유로에서의 가열에 의한 비정상 유동의 특성에 관한 연구)

  • Kim, Jang-Woo;Chung, Jin-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.765-771
    • /
    • 2002
  • This Paper presents numerical solutions of two-dimensional Euler equations for supersonic steady and unsteady flows with heat addition in a convergent-divergent duct, The Van Leer FVS (flux vector splitting) method in generalized coordinates is employed in order to calculate the inviscid strong shock waves caused by thermal choking. We discuss on transient characteristics, start and unstart phenomena caused by thermal choking, limit of equivalence ratio to avoid thermal choking and fluctuation of specific thrust caused by thermal choking. We prove that thermal choking is a serious problem in view of engine performance.

Characteristics of Elastics Waves of Fiber-Reinforced Plastic with Localized Heat Damage (국부 열손상을 받은 복합재료의 탄성파특성)

  • 남기우;김영운
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.4
    • /
    • pp.48-53
    • /
    • 2002
  • Fiber-reinforced composites are extensively used in electronic, ship and aerospace applications due to their high strength and high toughess. In these applications, they are often subjected to localized heat damage due to various sources. In order to ensure their reliability, it is important to predict their residual properties using nondestructive evaluation thchniques. Fabric fiber composite specimens were manufactured with six layers of the glass-fiber prepreg and the carbon-fiber prepreg, respectively. The specimens were subjected to a localized heat damage using a heated copper tip with a diameter of 10mm at 35$0^{\circ}C$(CFRP) and 30$0^{\circ}C$(GFRP), respectively. The specimens were then subjected to tension tests while acoustic emission (AE) activities of specimens were collected. The AE activity of all specimens showed three types of distinct frequency regions. Those are matrix cracking, failure of the fiber/matrix interface and fiber breakage.

Monitoring of Crop Water Stress with Temperature Conditions Using MTCI and CCI (가뭄과 폭염 조건에서 MTCI와 CCI를 이용한 수분 스트레스 평가)

  • Kyeong-Min Kim;Hyun-Dong Moon;Euni Jo;Bo-Kyeong Kim;Subin Choi;Yuhyeon Lee;Yuna Lee;Hoejeong Jeong;Jae-Hyun Ryu;Hoyong Ahn;Seongtae Lee;Jaeil Cho
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1225-1234
    • /
    • 2023
  • The intensity of crop water stress caused by moisture deficit is affected by growth and heat conditions. For more accurate detection of crop water stress state using remote sensing techniques, it is necessary to select vegetation indices sensitive to crop response and to understand their changes considering not only soil moisture deficit but also heat conditions. In this study, we measured the MERIS terrestrial chlorophyll index (MTCI) and chlorophyll/carotenoid index (CCI) under drought and heat wave conditions. The MTCI, sensitive to chlorophyll concentration, sensitively decreased on non-irrigation conditions and the degree was larger with heat waves. On the other hand, the CCI, correlated with photosynthesis efficiency, showed less sensitivity to water deficit but had decreased significantly with heat waves. After re-irrigation, the MTCI was increased than before damage and CCI became more sensitive to heat stress. These results are expected to contribute to evaluating the intensity of crop water stress through remote sensing techniques.

Analyzing Mortality Rate and Social Costs of Climate Vulnerable Groups caused by Heat Waves in Korea (폭염 발생에 따른 취약계층의 사망률 변화와 사회적 비용 추정: 7대 광역시의 65세 이상 고령층을 중심으로)

  • Shin, Dong-Hee;Lee, Na-Young;Cho, Yongsung
    • Journal of Environmental Policy
    • /
    • v.14 no.1
    • /
    • pp.3-32
    • /
    • 2015
  • The critical temperature and the rate of increase in excess death caused by heat waves in the age group of 65 years and older are derived. The value of statistical life method was used to quantify economic damages, and the willingness to pay after 71 years of age for 10 years was measured based on the dichotomous choice contingent valuation method survey. The result shows about KRW 481,110,000 is required annually to reduce the possibility of death by climate change to 1/1000.

  • PDF

Evaluation of a Sodium-Water Reaction Event Caused by Steam Generator Tubes Break in the Prototype Generation IV Sodium-cooled Fast Reactor

  • Ahn, Sang June;Ha, Kwi-Seok;Chang, Won-Pyo;Kang, Seok Hun;Lee, Kwi Lim;Choi, Chi-Woong;Lee, Seung Won;Yoo, Jin;Jeong, Jae-Ho;Jeong, Taekyeong
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.952-964
    • /
    • 2016
  • The prototype generation IV sodium-cooled fast reactor (PGSFR) has been developed by the Korea Atomic Energy Research Institute. This reactor uses sodium as a reactor coolant to transfer the core heat energy to the turbine. Sodium has chemical characteristics that allow it to violently react with materials such as a water or steam. When a sodium-water reaction (SWR) occurs due to leakage or breakage of steam generator tubes, high-pressure waves and corrosive reaction products are produced, which threaten the structural integrity of the components of the intermediate heat-transfer system (IHTS) and the safety of the primary heat-transfer system (PHTS). In the PGSFR, SWR events are included in the design-basis event. This event should be analyzed from the viewpoint of the integrities of the IHTS and fuel rods. To evaluate the integrity of the IHTS based on the consequences of the SWR, the behaviors of the generated high-pressure waves are analyzed at the major positions of a failed IHTS loop using a sodium-water advanced analysis method-II code. The integrity of the fuel rods must be consistently maintained below the safety acceptance criteria to avoid the consequences of the SWR. The integrity of the PHTS is evaluated using the multidimensional analysis of reactor safety-liquid metal reactor code to model the whole plant.