• Title/Summary/Keyword: Heat Transfer performance

Search Result 1,897, Processing Time 0.033 seconds

Application of Passive Solar Systems for Office Buildings (사무소 건물을 위한 자연형 태양열 시스템의 응용)

  • Park, Jin-Seo;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.22-28
    • /
    • 2010
  • This study analyzed the performance of passive solar system for office building. A unit model of the passive solar system was proposed in order to predict its performance under varying parameters and Seoul weather date. Steady state heat transfer equations were set up using a energy balanced equations and solved using a inverse matrix method. Numerical simulation program to analyze system was developed by using MATLAB. As the results, the passive solar system performance of office building was determined by the insolation and the outdoor air temperature. Also the passive solar system indicate 6.7~16.2% of annual average efficiency. In the comparison with other systems of the conventional wall, mass wall could reduce the heating loads of 7.1% and trombe wall could reduce heating loads of 11.5%. Through this study, performance of passive solar system for office building was verified by numerical method. Consequently, the passive solar system could operate an important role as the alternative for saving energy consumption of office building, and the additional studies should be made through the experimental method for the commercialization.

Modeling for the Performance Analysis of a Tubular SOFC/MGT Hybrid Power System (원통형 고체산화물 연료전지와 마이크로 가스터빈 하이브리드 시스템의 성능해석을 위한 모델링)

  • Song, T.W.;Sohn, J.L.;Kim, J.H.;Kim, T.S.;Ro, S.T.;Suzuki, K.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2070-2075
    • /
    • 2004
  • Performance of a solid oxide fuel cell (SOFC) can be enhanced by converting thermal energy of its high temperature exhaust gas to mechanical power using a micro gas turbine (MGT). A MGT plays also an important role to pressurize and warm up inlet gas streams of the SOFC. In this study, the influence of performance characteristics of the tubular SOFC on the hybrid power system is discussed. For this purpose, detailed heat and mass transfer with reforming and electrochemical reactions in the SOFC are mathematically modeled, and their results are reflected to the performance analysis. The analysis target is 220kWe SOFC/MGT hybrid system based on the tubular SOFC developed by Siemens-Westinghouse. Special attention is paid to the ohmic losses in the tubular SOFC counting not only current flow in radial direction, but also current flow in circumferential direction through the anode and cathode.

  • PDF

Effect of the Tube Geometry and Arrangement on the Performance of a High Temperarture Generator (고온재생기 성능 변화에 미치는 전열관 형상 및 배열의 영향)

  • Lee, In-Song;Cho, Keum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.546-551
    • /
    • 2007
  • The present study numerically investigated the tube geometry and arrangement on the performance of a high temperature generator (HTG) of the double effect LiBr-water absorption system. FLUENT, as a commercial code, was used to estimate the thermal performance of the HTG. Key parameters were the spacing raito of circular and flattened tubes, the pitch ratio of the rib on the flattened tube, and total heat transfer area of the HTG. Temperature and velocity profiles around the tubes of the HTG were calculated to estimate the thermal performance of the HTG. When the spacing ratio of circular and flattened tube is 1.11 and 0.73, the exhaust gas temperature is $185^{\circ}C$ without rib. The exhaust gas temperature when applied the rib in flattened tubes was lower by $24^{\circ}C$ than that without the rib. Rib can reduce the HTG volume by 7%.

  • PDF

Application of Solar Chimney System for Natural Ventilation in Underground Space (지하공간의 자연환기를 위한 태양 굴뚝 시스템의 응용)

  • Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.87-95
    • /
    • 2010
  • This study analyzed the performance of solar chimney system for natural ventilation in underground space. A mathematical model of the solar chimney was proposed in order to predict its performance under varying parameters and Korea climatic condition. Steady state heat transfer equations were set up using a energy balanced equations and solved using a inverse matrix method. Numerical simulation program to analyze system was developed by using MATLAB. As the results, the ventilation performance of the solar chimney was determined by the temperature difference of air channel and inlet, and the temperature difference was influenced by insolation, stack height and distance of air gab. Also the solar chimney system can provide $262.9m^3/h$ of annual average ventilation rate. Because seasonal differences of ventilation rate was calculated within 25%, the solar chimney system can be used for every season in Korea climatic condition. Through this study, performance of solar chimney system for natural ventilation was verified by numerical method. Consequently, the solar chimney system is proved to be effective device for natural ventilation utilizing at all times, and the additional studies should be made through the experimental method for imagineering and commercialization.

The DISNY facility for sub-cooled flow boiling performance analysis of CRUD deposited zirconium alloy cladding under pressurized water reactor condition: Design, construction, and operation

  • Ji Yong Kim;Yunju Lee;Ji Hyun Kim;In Cheol Bang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3164-3182
    • /
    • 2023
  • The CRUD on the fuel cladding under the pressurized water reactor (PWR) operating condition causes several issues. The CRUD can act as thermal resistance and increases the local cladding temperature which accelerate the corrosion process. The hideout of boron inside the CRUD results in axial offset anomaly and reduces the plant's shutdown margin. Recently, there are efforts to revise the acceptance criteria of emergency core cooling systems (ECCS), and additionally require the modeling of the thermal resistance effect of the CRUD during the performance analysis. There is an urgent need for the evaluation of the effect of the CRUD deposition on the cladding heat transfer under PWR operating conditions, but the experimental database is very limited. The experimental facility called DISNY was designed and constructed to analyze the CRUD-related multi-physical phenomena, and the performance analysis of the constructed DISNY facility was conducted. The thermal-hydraulic and water chemistry conditions to simulate the CRUD growth under PWR operating conditions were established. The design characteristics and feasibility of the DISNY facility were validated by the MARS-KS code analysis and separate performance tests. In the current study, detailed design features, design validation results, and future utilization plans of the proposed DISNY facility are presented.

Concentration Differences in LH, FSH and Progesterone Secretion among Seasonal Changes in Hanwoo and Holstein Heifers in Daegwallyeong

  • Chung, Hak-Jae;Yoon, Hyun-Il;Lee, Suk-Dong;Ko, Jin-Sung;Choy, Yun-Ho;Choi, Seong-Bok;Jeon, Gi-Jun;Ko, Yeoung-Gyu;Lee, Hwi-Cheul;Im, Seok-Ki;Lee, Myeung-Sik
    • Journal of Embryo Transfer
    • /
    • v.23 no.4
    • /
    • pp.257-261
    • /
    • 2008
  • The objective of present study was to investigate the effect of seasons on reproductive performance of Hanwoo and Holstein heifers. Heat stress in summer or cold stress in winter stress to Hanwoo and Holstein heifers may bring reproduction failure, which would pose an important economic loss, even around Daegwallyeong region located in high mountainous area. Seasonal differences in the serum levels of LH, FSH and progesterone ($P_4$) in response to environmental factors (hot and cold) out of 20 pubertal Hanwoo heifers in Daegwallyeong, Gangwon Province and 20 non-lactating Holstein heifers in Chonan city of Republic of Korea at 2-3 years of age were compared. Blood samples for hormonal analysis were from jugular vein after detection of estrus repeatedly over four seasons within four-week intervals (Spring: May to June, Summer: July to August, Autumn: October to November and Winter: January to February). In Hanwoo heifer population, averages of LH and FSH concentration in spring and in summer were greater compared to those in winter (p<0.05). LH or FSH levels tended to be greater (p=0.06) in spring and less (p=0.09) in winter compared to the levels in autumn. Only in summer, cattle seemed to show lower LH or FSH secretion (p<0.05). Similar to the results in Hanwoo heifers, the serum concentrations of LH and FSH in Holstein heifers decreased further by heat stress in summer when P 4 levels were high during luteal phase. The results demonstrate significant effect of summer heat on reproduction of Hanwoo or Holstein heifers. Although parameters indicating the extent of heat stress were not measured in this study, we suggest that serum hormone levels could be considered as successful indicators of summer heat stress condition for Hanwoo and Holstein heifers even under rather cool summer climate.

Prediction of Thermal Behavior of Automotive LNG Fuel Tank (LNG 자동차 연료 탱크의 열적 거동에 대한 예측)

  • NamKoong, Kyu-Won;Chu, Seok-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.9
    • /
    • pp.875-883
    • /
    • 2010
  • The thermal performance of LNG fuel tanks of vehicles is determined by the time for non-venting storage of fuel and the amount of fuel supplied to the engine. In this study, we selected a double-walled vacuum-insulated fuel tank with a volume of 450 liter, and the properties of the fuel contained in it were assumed to be the same as those of the methane($CH_4$). For the increasing the non-venting fuel storage time, we propose the use of shielded penetration pipes in the tank. We compared the storage times of the tank used in our study with those of the conventional fuel tank. Further, the additional heat input required to maintain the fuel pressure necessary for an appropriate fuel supply rate was predicted. For these parameters, we derived a thermodynamic relationship that can be used to estimate the rate of increase in pressure for a known heat input, and we obtained equations for estimating the rate of heat leaked by using the established heat transfer model. From the results of numerical computation, we found the non-venting storage time of the tank with shielded pipes to be 25-30% higher than that of the tank with unshielded pipes. Further, we determined the appropriate operation conditions by taking into consideration the transfer rate of additional heat provided to the fuel tank.

A Study of Heat Transfer during Freezing Process of Water in a Vertical Cylinder - Comparison of thermal storage performance on the working fluid direction - (수직원통형 축열조내 물의 응고과정시 열전달에 관한 실험적연구 - 작동유체의 유동방향에 따른 열저장성능 비교 -)

  • Heo, K.;Kim, Y.K.;Kim, Y.J.;Kim, J.K.;Yim, C.S.
    • Solar Energy
    • /
    • v.15 no.2
    • /
    • pp.77-90
    • /
    • 1995
  • An effective heat transfer during freezing process was proposed in the vertical cylinder to improve the effectiveness of the heat storage. Vertical cylinder was filled with pure water in order to investigate ice-shape, temperature distribution of the liquid, temperature distribution of the cylinder tube wall, total heat storage per unit mass in the test section under the two experimental conditions; inlet temperature of working fluid is constant($-10^{\circ}C$) and inlet direction of working fluid is either upward flow or downward. Both the mean temperature of the liquid and temperature difference of cylinder tube wall in the upward were lower than those in the downward. In case that the initial temperature of water was $7^{\circ}C$ and $4^{\circ}C$, the shape of ice layer in the upward was more uniform than that in the downward. In case of $1^{\circ}C$, the shape of ice layer is formed by inlet direction of working fluid. Finally, time-varying total heat energy stored in the water in the upward was higher than that in the downward.

  • PDF

Design and Performance Evaluation of Low-Temperature Vacuum Blackbody System (저온-진공 흑체시스템의 설계 및 성능 평가)

  • Kim, Ghiseok;Chang, Ki Soo;Lee, Sang-Yong;Kim, Geon-Hee;Kim, Dong-Ik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.336-341
    • /
    • 2013
  • In this paper, the design concept of a low-temperature vacuum blackbody was described, and thermophysical model of the blackbody was numerically evaluated. Also the working performance of low-temperature vacuum blackbody was evaluated using infrared camera system. The blackbody system was constructed to operate under high-vacuum conditions ($2.67{\times}10^{-2}$ Pa) to reduce temperature uncertainty, which is caused by vapor condensation at low temperatures usually below 273 K. In addition, both heat sink and heat shield including cold shield were installed around radiator to prevent heat loss from the blackbody. Simplified mathematical model of blackbody radiator was analyzed using modified Stefan-Boltzmann's rule. The infrared radiant performance of the blackbody was evaluated using infrared camera. Based on the results of measurements, and simulation, temperature stability of the low-temperature vacuum blackbody demonstrated that the blackbody system can serve as a highly stable reference source for the calibration of an infrared optical system.

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.