• Title/Summary/Keyword: Heat Transfer performance

Search Result 1,897, Processing Time 0.034 seconds

Research of Energy Efficiency for Power Plant Performance Improvement (발전성능 향상을 위한 에너지 효율 연구)

  • Lee, Jae-Keun;Moon, Jeon-Soo
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.3
    • /
    • pp.220-226
    • /
    • 2010
  • The heat transfer performance improvement in closed cooling water system of an electric power generation can be achieved by a corrosion control using corrosion inhibitors. The effect of trisodium phosphate and sodium nitrite upon carbon steel at various $Cl^{-1}$ ion containing water concentrations was examined by an integrated corrosion monitoring system. Nitrite was found to be the most effective inhibitor among tested inhibitors for carbon steel. The inhibiting process is considered as adsorption of nitrite ions in oxide layer which form a passive film on the carbon steel surface.

Comparison of Unconfined and Confined Micro-scale Impinging Jets

  • Choo, Kyo-Sung;Youn, Young-Jik;Kim, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2210-2213
    • /
    • 2008
  • In the present study, effects of degree of confinement on heat transfer characteristics of a micro-scale slot jet impinging on a heated flat plate are experimentally investigated. The effects of Reynolds numbers (Re = $1000{\sim}5000$), lateral distances (x/B = $1{\sim}10$), nozzle-to-plate spacings (Z/B = $1{\sim}20$), and degree of confinement ($B_c$/B = 3, 48) on the Nusselt number are considered. The results show that the effects of the degree of confinement on the cooling performance of the micro-scale impinging slot jet are significant at lower nozzle-to-plate spacings and higher Reynolds numbers. In addition, it is shown that the cooling performance of the micro-scale unconfined slot impinging jet is 200% higher than that of the micro-scale confined slot impinging jet.

  • PDF

A Research on the Assessment of Thermal Performance of Energy Storage Li-Ion Battery Pack (에너지 저장용 Li-Ion 배터리 팩의 열적 성능 평가에 관한 연구)

  • Jang, Hyuk;Jang, KyungMin;Kim, KwangSun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.1
    • /
    • pp.101-108
    • /
    • 2014
  • The battery pack in this research consists of dozens of a small battery for energy storage. And this battery pack charges and discharges repeatedly at high capacity (25 ~ 50 V, 25 ~ 100 A). The high temperature which can be generated in this process has a bad effect to the lifetime and efficiency of batteries. Moreover these factors are related with maintenance cost. Therefore, we need to assess the thermal performance of the battery pack in advance using the experimental or numerical analysis. In this research, we analyzed voltage and surface temperature of one cell battery to calculate heat transfer using the numerical analysis. And the temperature of the battery surfaces and inside of the pack was also analyzed. As a result, we found out the appropriate pack structure which stacked five modules.

Design of an Ammonia/water Bubble Absorber with Binary Nanofluids (이성분 나노유체를 이용한 암모니아/물 기포 흡수기 설계)

  • Kim Jin-Kyeong;Kim Sung-Soo;Kang Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.556-562
    • /
    • 2006
  • The objectives of this paper are to analyze simultaneous heat and mass transfer performance for a plate type bubble absorber with binary nanofluids numerically and to investigate the effects of binary nanofluids and surfactants on the size of the bubble absorber. The effective absorption ratio represents the effect of binary nanofluids and surfactants on the absorption performance. The kinds and concentrations of nano-particles and surfactants are considered as the key parameters. The results show that the addition of surfactants can reduce the size of absorber up to 74.4%, the application of binary nanofluids does the size up to 63.6%. Combination of binary nanofluids and surfactants can reduce the size of absorber up to 77.4%.

Application of One-Dimensional Heat Transfer Models for Performance Prediction of a Thermodiode (열다이오드의 열전달 성능 예측을 위한 일차원 모델적용 연구)

  • Chun, Won-Gee;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.77-87
    • /
    • 2002
  • 그 열흐름의 방향이 인위적으로 조절 가능한 열다이오드 시스템에 관하여 일차원적 열전달 모델을 통하여 시스템의 열성능을 분석하였다. 열다이오드 시스템은 다수의 폐회로 유체 순환 루프로 구성되었으며 루프의 양단은 각각 태양열 흡열판과 방열판에 부착되었다. 한편, 열흐름의 방향 조절을 위하여 루프를 구성하는 튜브재의 연결 부위는 회전 가능한 조인트로 연결하였으며 열매체포는 물을 사용하였다. 본 연구에서는 열다이오드 시스템에 대하여 간단한 1차원 모델을 이용하여 시스템의 열성능을 평가하였으며 아울러 실측 결과와의 비교를 통하여 본 모델의 적용을 통한 시스템의 장기 예측에 대한 가능성을 확인하였다.

An Experimental Study on the Performance of a Freeze-Protected Direct Solar Water Heating System (비동파 직접식 온수 급탕 시스템의 열성능에 관한 연구)

  • Chun, W.G.;Kim, H.T.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.33-38
    • /
    • 1998
  • This paper reports the experimental results concerning the thermal performance of a freeze-protected direct solar water heating system. The direct system tested has been manufactured to prevent any breakage during harsh wintry conditions by specially designed riser and downcomer headers capable of relieving extra pressure due to freezing of water. The direct system tested has shown 10% improvement in its efficiency over that of a indirect type system using antifreeze as the heat transfer medium. It is felt that any direct system of its kind could galvanize the whole solar industry if further improvements are made to ensure its durability.

  • PDF

A Study on the Dynamic Performance Behavior of Solid Oxide Fuel Cells with Stepwise Load Changes (갑작스런 부하 변동에 따른 고체산화물 연료전지의 동적 성능 거동 특성에 관한 연구)

  • Sohn Jeong Lak;Ro Sung Tack;Yang Jin Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.4 s.235
    • /
    • pp.477-484
    • /
    • 2005
  • Model fer the dynamic simulation of dynamic behaviors of a solid oxide fuel cell (SOFC) is provided. This model is based upon (1) coupled mass and heat transfer characteristics and (2) important chemical reactions such as electrochemical and reforming reactions in high temperature fuel cells such as SOFC. It is found that the thermal inertia of solid materials in SOFC plays an important role to the dynamic behavior of cell temperature. Dynamic characteristics of cell voltage, power, and chemical compositions with different levels of load change are investigated.

Performance Analysis of Photonic Crystal Enhanced Micro-Combustor Thermophotovoltaic System for Drone Application (광결정 표면을 이용한 드론용 마이크로 연소기 열광전 에너지변환시스템의 성능해석)

  • Lee, Junghun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.309-316
    • /
    • 2021
  • In this paper, the electrical power output of the micro-combustor thermophotovoltiac(TPV) system was analyzed. The system consists of a micro-combustor, photonic crystals(PhCs), and photovoltaic cells(PV cells). The system has a micro-combustor that can achieve over 1,000 K surface temperature by consuming 2.5 g/h hydrogen fuel. Also, this system incorporates current state-of-the-art PhCs surfaces(2D Ta PhCs and Tandem Filter) to increase electrical power output. In addition, InGaAsSb PV cell, which bandgap is 0.55 eV, was applied to convert a wide range of radiative energy. The performance analysis shows that a single micro-combustor TPV system can produce 0.4 W ~ 27.7 W electrical power with the temperature change of emitter(900 K ~ 1,500 K) and PV cell(250 K ~ 400 K).

Analysis of Combustion Air Flow in Incinerator (소각로의 연소 공기 유동 해석)

  • Lee, Dong-Hyuk
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.26-32
    • /
    • 2022
  • It is known that the fluidized bed incinerator, which is the subject of analysis, shows excellent performance in heat and mass transfer due to excellent mixing and contact performance between fluidized sand and fuel, and also shows relatively good combustion characteristics thanks to good mixing and long residence time for low-grade fuels. have. In this study, air flow analysis is performed to understand the characteristics of co-firing of sludge, waste oil and solid waste in the fluidized bed incinerator, flow characteristics of flue gas, and discharge characteristics of pollutants.The fluidized bed incinerator subject to analysis is a facility that incinerates factory waste and general household waste together with sludge, with a processing capacity of 32 tons/day. to be. In addition, the operation method was designed for continuous operation for 24 hours. As a result, it can be seen that the lower combustion air and the introduced secondary air are changed to a strong turbulence and swirl flow form and exit through the outlet while rotating inside the freeboard layer. The homogeneous one-way flow form before reaching the secondary air nozzle has very high diffusivity with the high-speed jet flow of the nozzle.

Two-fluid modelling for poly-disperse bubbly flows in vertical pipes: Analysis of the impact of geometrical parameters and heat transfer

  • Andrea Allio ;Antonio Buffo ;Daniele Marchisio;Laura Savoldi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1152-1166
    • /
    • 2023
  • The bubbly flow of air or steam in subcooled water are investigated here in several test cases, characterized by different pipe sizes, bubble dimensions and flow rates, by means of CFD using a Eulerian-Eulerian approach. The performance of models that differ for the turbulence closure in the continuous phase, as well as for the description of the lift force on the dispersed phase, are compared in detail. When air is considered, the space of the experimental parameters leading to a reasonable performance for the selected models are identified and discussed, while the issues left in the modelling of the concurrent condensation are highlighted for the cases where steam is used.