• Title/Summary/Keyword: Heat Transfer Experiment

Search Result 742, Processing Time 0.036 seconds

Study on the Optimization Field Welding Conditions of Low Heat-Input Pluse MIG Welding Process for 5052 Aluminum Alloy Sheets (Al 5052 합금의 저입열 Pulse MIG 최적 현장 용접조건 산정에 관한 실험적 연구)

  • Kim, Jae-Seong;Lee, Young-Gi;An, Ju-Sun;Lee, Bo-Young
    • Journal of Welding and Joining
    • /
    • v.29 no.1
    • /
    • pp.80-84
    • /
    • 2011
  • The weight reduction of the transportations has become an important technical subject Al and Al alloys, especially Al 5052 alloys have been being applied as door materials for automobile. One of the most widely known car weight-reduction methods is to use light and corrosion-resistant aluminum alloys. However, because of high electrical and thermal conductivity and a low melting point, it is difficult to obtain good weld quality when working with the aluminum alloys. Also, Pulse MIG welding is the typical aluminum welding process, but it is difficult to apply to the thin plate, because of melt-through and humping-bead. In order to enhance weld quality, welding parameters should be considered in optimizing the welding process. In this experiment, Al 5052 sheets were used as specimens, and these materials were welded by adopting new Cold Metal Transfer (CMT) pulse process. The proper welding conditions such as welding current, welding speed, torch angle $50^{\circ}$ and gap 0~1mm are determined by tensile test and bead shape. Through this study, range of welding current are confirmed from 100A to 120A. And, the range of welding speed is confirmed from 1.2m/min to 1.5m/min.

The Drying Characteristics of Apples at Various Drying Conditions (사과의 건조조건(乾燥條件)에 따른 건조특성(乾燥特性))

  • Jung, Shin-Kyo;Choi, Yong-Hee;Shon, Tae-Hwa;Choi, Jong-Uck
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.61-65
    • /
    • 1986
  • This study was performed to examine the drying characteristics of apples at various drying conditions. Air velocity has no effect on the drying rate except the constant rate period. In this experiment the diffusion coefficients of moisture in the apple tissue were in the range of $1.1470-2.2148{\times}10cm^2/sec$. As a result of balance of heat and mass transfer during the falling rate period. an empirical equation based on Fick's law was obtained as follows; $log{\Delta}t\;=\;log\;t_o\;-\;D{\frac{{\pi}^2{\theta}}{4d.}}$ This equation can be used to calculate the temperature of apples during the falling rate period, provided the diffusion coefficients of apple are known. The experimental values of the internal moisture distribution during apple dehydration were nearly in accord with the theoretical values.

  • PDF

Research on an Optimal Trickling Surface of the Regenerator in a Solar Air-conditioning System (태양열 이용 냉난방 공조시스템중 재생기의 최적 재생면 구조에 관한 연구)

  • Kim, B.C.;Choi, K.H.;Kum, J.S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.185-195
    • /
    • 1998
  • The high viscosity of a LiCl(lithium chloride) solution as an absorbent in a solar energy regenerator causes a channeling phenomenon on the solar powered absorber plate surface when the solution is trickling down for regenerating itself. As this channeling phenomenon affects badly the heat and mass transfer, it is pertinent that this phenomenon be studied. Since regenerating performance of the solar energy regenerator depends on how the solution uniformly flows on the plate surface, an experiment on the structure of the plate surface for a model regenerator was conducted. Various shapes and structures of the plat surface down which the LiCl solution trickled were tested, and it was found that a tiered surface showed the highest water evaporation rate leaving more potential energy concentrating LiCl on the plate. It was also observed that the water evaporation rate depended largely on the pitch and height of the disturbing rods. In addition, the wider the contact area is and the longer the solution's flow time, the better the solar energy regenerator's performance.

  • PDF

Characteristic Analysis of BIPV Module according to Rear Materials (후면부재에 따른 BIPV 모듈의 특성 분석)

  • Kim, Hyun-Il;Kang, Gi-Hwan;Park, Kyung-Eun;Yu, Gwon-Jong;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.28-33
    • /
    • 2009
  • In 2008, the global photovoltaic(PV) market reached 5.6GW and the cumulative PV power installed totalled almost 15GW compared to 9GW in 2007. Due to a favourable feed-in-tariff, Korea emerged in 2008 as the 4th largest PV market worldwide. PV power installation rose 495.5 percent to 268MW in 2008 compare to 45MW in 2007. Building integrated photovoltaic(BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influenced on the reflection by rear materials such as white back sheet and the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. In this study, to use as suitable building materials into environmentally friendly house like green home, characteristic analysis of BIPV module according to rear materials achieved. Electrical output of PV module with white back sheet is high about 10% compared to other pv module because of 83% reflectivity of white back sheet compared to 8.4% reflectivity of other PV modules with different rear materials(black back sheet and glass). In the result of outdoor experiment during a year, electrical output of four different PV module is decreased about 3.72%.

Prediction of the effective thermal conductivity of microsphere insulation

  • Jin, Lingxue;Park, Jiho;Lee, Cheonkyu;Seo, Mansu;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.36-41
    • /
    • 2014
  • Since glass microsphere has high crush strength, low density and small particle size, it becomes alternative thermal insulation material for cryogenic systems, such as storage and transportation tank for cryogenic fluids. Although many experiments have been performed to verify the effective thermal conductivity of microsphere, prediction by calculation is still inaccurate due to the complicated geometries, including wide range of powder diameter distribution and different pore sizes. The accurate effective thermal conductivity model for microsphere is discussed in this paper. There are four mechanisms which contribute to the heat transfer of the evacuated powder: gaseous conduction ($k_g$), solid conduction ($k_s$), radiation ($k_r$) and thermal contact ($k_c$). Among these components, $k_g$ and $k_s$ were calculated by Zehner and Schlunder model (1970). Other component values for $k_c$ and $k_r$, which were obtained from experimental data under high vacuum conditions were added. In this research paper, the geometry of microsphere was simplified as a homogeneous solid sphere. The calculation results were compared with previous experimental data by R. Wawryk (1988), H. S. Kim (2010) and the experiment of this paper to show good agreement within error of 46%, 4.6% and 17 % for each result.

Mathematical Modeling and Simulation for Steady State of a 75-ton Liquid Propellant Rocket Engine (75톤급 액체로켓엔진 정상상태 과정의 수학적 모델링 및 시뮬레이션)

  • Lee, Kyelim;Cha, Jihyoung;Ko, Sangho;Park, Soon-Young;Jung, Eunhwan
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.6-12
    • /
    • 2017
  • This paper deals with mathematical modeling of a 75-ton open-cycle Liquid Propellant Rocket Engine (LPRE) and the steady state simulation based on a nominal operating point. Each component of open-cycle LPRE may be classified into seven major categories using thermodynamics and dynamics characteristics. To simplify the simulation model of LPRE in this paper, we used four govern equations with assuming no heat transfer process. We confirmed the mathematical model of LPRE by using the error ratio and comparing the experiment data and simulation data in steady state, and checked the stability with the linearized model. Finally, we demonstrated the simulation model as compared to the transient response of experimental data.

Experimental Investigation on the Cryogenic Thermosiphon Using N$_2$ and CF$_4$ Mixture as the Working Fluid (N$_2$와 CF$_4$ 혼합물을 작동유체로 하는 극저온 열사이펀에 대한 실험적 연구)

  • Kim, Young-Kwon;Lee, Ji-Sung;Jeong, Sang-Kwon;Han, Young-Hee;Jung, Se-Yong;Park, Byung-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.505-512
    • /
    • 2009
  • A thermosiphon is utilized as a thermal shunt to reduce the cool-down time of a cryogenic system cooled by a two stage cryocooler. The cool-down time reduction by the thermosiphon is determined by the type of working fluid which is directly related to the operating temperature range of the thermosiphon. A mixed working fluid has a potential to widen the operation temperature range of the thermosipohon. In this study, the thermosiphon using N$_2$ and CF$_4$ mixture as the working fluid is fabricated and tested to verify its transient heat transfer performance. The thermosiphon with the mixed working fluid has no noticeable reduction of cool-down time compared with that of the thermosiphon with pure working fluid in this experiment. However, it seems that the thermosiphon with mixed working fluid may have an advantage according to the cooling capacity of a cryocooler, the cooling target temperature and the size of a cooling object.

Radiative Role of Clouds on the Earth Surface Energy Balance (지표 에너지 수지에 미치는 구름의 복사 역할)

  • Hong, Sung-Chul;Chung, Ii-Ung;Kim, Hyung-Jin;Lee, Jae-Bum;Oh, Sung-Nam
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.261-267
    • /
    • 2007
  • In this study, the Slab Ocean Model (SOM) is coupled with an Atmospheric General Circulation Model (AGCM) which developed in University of Kangnung based on the land surface model of Biosphere-Atmosphere Transfer Scheme (BATS). The purposes of this study are to understand radiative role of clouds considering of the atmospheric feedback, and to compare the Clouds Radiative Forcing (CRF) come from the analyses using the clear-cloud sky method and CGCM. The new CGCM was integrated by using two sets of the clouds with radiative role (EXP-A) and without radiative role (EXP-B). Clouds in this two cases show the negative effect $-26.0\;Wm^{-2}$ of difference of radiation budget at top of atmosphere (TOA). The annual global means radiation budget of this simulation at TOA is larger than the estimations ($-17.0 Wm^{-2}$) came from Earth Radiation Budget Experiment (ERBE). The work showed the surface negative effect with $-18.6 Wm^{-2}$ in the two different simulations of CRF. Otherwise, sensible heat flux in the simulation shows a great contribution with positive forcing of $+24.4 Wm^{-2}$. It is found that cooling effect to the surface temperature due to radiative role of clouds is about $7.5^{\circ}C$. From this study it could make an accurate of the different CRF estimation considering either feedback of EXP-B or not EXP-A under clear-sky and cloud-sky conditions respectively at TOA. This result clearly shows its difference of CRF $-11.1 Wm^{-2}$.

Overall Heat Transfer Coefficient Measurement of Covering Materials with Thermal Screens for Greenhouse using the Hot Box Method (핫박스를 이용한 온실 피복재 및 보온재의 조합에 따른 관류열전달계수 측정)

  • Diop, Souleymane;Lee, Jong-Won;Na, Wook-Ho;Lee, Hyun-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.5
    • /
    • pp.1-7
    • /
    • 2012
  • 본 연구의 목적은 국내에서 상용되고 있는 온실 피복재 및 보온재의 조합에 따른 관류열전달계수를 핫박스를 이용하여 평가하는 것이다. 온실용 일중 및 이중 피복재와 이중 보온재의 조합에 대하여 야간천공복사 차단여부에 따른 관류열전달계수를 핫박스를 이용하여 실외에서 측정하였다. 처리조건은 일중피복, 이중피복, 이중피복과 이중 마트보온재 및 이중피복과 이중 다겹보온재의 조합조건과 천공복사 유무에 따른 조건이며 총 8가지이다. 제작된 핫박스는 상시 변화하는 외부의 기상조건하에서도 내부온도를 설정된 온도로 일정하게 잘 유지할 수 있었다. 온실 피복재 및 보온재의 관류열전달계수를 측정하는 실내용 측정장치는 반드시 야간천공복사를 모의할 수 있는 측정장치가 되어야 할 것이다. 야간복사를 차단함으로서 온실의 열 손실을 줄여 보온효과를 얻을 수 있을 것으로 분석되었다. 모든 피복방식에 대해 야간복사 차단장치 유무에 관계없이 높은 풍속에서의 관류열전달계수가 낮은 풍속에서보다 더 큰 것으로 나타났다. 본 연구에서 사용된 측정기법을 사용하면 국내에서 생산되는 피복재 및 보온재의 관류열전달 특성을 정량적으로 비교할 수 있을 것으로 기대된다.

Vacuum Freeze Drying of Skim Milk Solution in a Cylindrical Container: Comparison of Experimental and Numerical Results (원통형 용기에 담긴 탈지분유 용액의 진공동결건초 : 실험결과와 해석결과의 비교연구)

  • Song, Chi-Seong;Nam, Jin-Hyeon;Kim, Chan-Jung;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.288-301
    • /
    • 2002
  • A vacuum freeze drying experiment of skim milk solution in a cylindrical container is conducted to investigate the multi-dimensional drying characteristics of the process during the primary drying stage. Temperature histories at several positions are measured under the same process condition that is carefully controlled. Then the measured temperature histories at different positions are combined to produce instantaneous temperature distribution fields inside the cylindrical container. Along with the temperature measurement, the mass reduction history of the skim milk solution is also measured. From the measured temperature distribution curved configurations of sublimation interfaces and 2-dimensional heat transfer is inferred. The freeze drying under the present experimental setup is simulated with a calculation program that is based on a finite volume method with a moving grid system. Good agreements between the numerical and experimental results are observed. The present experimental results and the numerical approaches can be useful information in developing the analysis tools for practical vacuum freeze drying processes.