Two dimensional flow and heat/mass transfer characteristics in rectangular wavy duct with corrugation angle (2차 유동 영역에서 꺽임각 변화에 따른 주름진 사각 덕트에서의 열/물질전달 및 유동 특성)

  • Kwon, Hyun-Goo;Hwang, Sang-Dong;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2267-2272
    • /
    • 2007
  • The present study investigates the two dimensional flow and heat/mass transfer characteristics of wavy duct with various corrugation angles. For the heat/mass transfer coefficients, a naphthalene sublimation technique is used. Numerical analysis and wall pressure measurement show detailed two dimensional flow features. The corrugation angles change from 145$^{\circ}$ to 100$^{\circ}$. The operating Reynolds numbers based on the duct hydraulic diameter vary from 700 to 3,000. The duct aspect ratio maintains 7.3. On the pressure wall, strong flow mixing enhances heat/mass transfer coefficients at the front position. In addition, the rear side of pressure wall, the near of peak, is affected by the acceleration and the shedding of main flow. On the suction wall, however, flow separation and reattachment lead to the valley and the peak of heat/mass transfer coefficient. Also, highly increasing boundary layer at the suction wall affects the decrease of heat/masst transfer. As decreasing corrugation angles, the spanwise average Sherwood number increases and the peak or the valley positions of the local Sherwood number are varied.

  • PDF

Augmentation of Heat Transfer for Circular Water Jet Impinging on a Cylindrical Inner Surface (충돌수분류(衝突水噴流)에 의한 원통내면(圓筒內面)에서의 열전달증진(熱傳達增進)에 관한 연구(硏究))

  • Ohm, K.C.;Woo, C.K.;Choi, G.G.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.4
    • /
    • pp.279-287
    • /
    • 1990
  • An experimental study of the heat transfer characteristics between circular water jet and cylindrical inner surface is presented. The ratios of the semi-cylinder's inner diameter and the nozzle outlet diameter were varied parametrically, as were the Reynolds number and the supplementary water heights. The measurements showed that cirucmferential distribution of the heat transfer coefficient peaked at the stagnation point and, there occurred a kind of a secondary maximum of heat transfer that moved toward to stagnation point as the ratio d/D increased. The local heat transfer coefficient increases as the Reynolds number becomes larger, and the rate of increase is subjected to the influence of d/D & position of angle. Also, optimum heights of supplementary water which brings about the augmentation of heat transfer are S/D=1 for the stagnation point, the position of $15^{\circ}$ & $30^{\circ}$ angle, but for the positions of $45^{\circ}$ angle (d/D=10~11.67), $60^{\circ}$ & $75^{\circ}$ angle, the heat transfer coefficients in the case of using supplementary water are smaller than simple jet (S/D=0).

  • PDF

A study on the characteristics of heat transfer and pressure drop in plate type evaporator with U-turn for automotive air conditioner (유턴 흐름을 갖는 차량공조용 플레이트형 증발기의 전열특성에 관한 연구)

  • 강정길;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.472-483
    • /
    • 1999
  • The evaporation heat transfer and pressure drop characteristics for HFC-l34a in flat plate type heat exchangers with enhanced beads were experimentally investigated. Three plate type evaporators with different geometric condition of U-turn area were tested. Mass fluxes were tested over the range of 83kg/$m^2$s to 166kg/$m^2$s, and heat fluxes were varied from 4㎾/$m^2$ to 12㎾/$m^2$. Evaporation temperature was 5$^{\circ}C$ with inlet qualities of 0.1 to 1.0. There was no notable difference in the heat transfer coefficient by geometric variation of U-turn area, but the third plate with cross-ribbed channel at U-turn area was better than others in the evaluation using volume goodness factor comparison. Also, the mixtures of HFC-l34a and PAG oil was tested to determine oil effects on heat transfer and pressure drop. As oil concentration was increased, heat transfer coefficient was increased by 22~48% up to the 3wt.%, but decreased by 14~22% at the 4wt.%. The pressure drop was increased by the maximum of 100% as oil concentration was increased.

  • PDF

ANALYSIS OF HEAT TRANSFER PERFORMANCE WITH ASPECT AND FILLING RATIOS IN THERMOSYPHON (열사이펀의 형상비와 충전율에 따른 열전달 성능 해석)

  • Kim, Y.C.;Choi, J.W.;Kim, S.C.
    • Journal of computational fluids engineering
    • /
    • v.20 no.1
    • /
    • pp.92-98
    • /
    • 2015
  • Thermal-fluid analysis is performed numerically to figure out the characteristics of heat transfer in a thermosyphon varying with the aspect ratio of geometry and the filling ratio of working fluid. The computational results are reasonable compared with the experimental data and visualized. The thermal resistance and the convective heat transfer coefficients are evaluated with the aspect ratio of thermosyphon and the filling ratio of working fluid, respectively. In conclusion, the thermal resistance decreases as the length of evaporator increases. However, the variation of a condenser length is nearly independent on the thermal resistance. In order to raise the performance of thermosyphon, the working fluid needs to be filled over 75%. In addition, Nusselt numbers in the evaporator and the condenser show 275 and 304, respectively.

Study on Development of High Performance Evaporator for Automotive Air Conditioner (자동차 공조용 증발기의 고성능화에 관한 연구)

  • Kang, J.K.;Kim, K.H.;Park, T.Y.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.73-80
    • /
    • 1995
  • The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribbed channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermoviewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of $2.116kg/cm^2$, (2) mass fluxes of 40 to $70kg/m^2s$, (3) heat fluxes of 4,500 to $7,300W/m^2$, (4) inlet quality of 0.1 to 0.7. The results indicated that the evaporative heat transfer coefficient of an elliptical-ribbed plate heat exchanger was higher than that of cross-ribbed plate heat exchanger. Also optimal turn clearance in an elliptical-ribbed plate heat exchanger was determined.

  • PDF

Heat Transfer Characteristics of R-407C During Condensing Inside Horizontal Smooth and Micro-Fin Tubes (수평 평활관 및 전열촉진관내 대체 냉매 R-407C의 응축 열전달 특성에 관한 연구)

  • Roh, Geonsang;Oh, Hookyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.210-217
    • /
    • 1999
  • This paper reports the experimental results on heat transfer characteristics of R-22 and R-407C(HFC-32/125/134a 23/25/52 wt%) condensing inside horizontal smooth and finned tubes. The test condensers used In the study are double pipe heat exchangers of 7.5 mm ID, 9.5 mm OD smooth tube, and 60 finned micro-fin tube with 8.53 mm ID, 9.53 mm OD. Each of these tubes was 4 000 mm long tubes connected with an U-bend. These U type two-path test tubes are divided In 8 local test sections for the identification of the local condensing heat transfer characterisitcs and pressure drop, U-bend effects on condensing flows. Inlet quality is maintained 1.0, and refrigerant mass velocity is varied from 102.0 to $301.0kg/m^2{\cdot}s$. From the results, it was found that the pressure drop of the R-407C Increased, and heat transfer coefficient decreased compared to those of R-22. In comparison condensing heat transfer characteristics of micro-fm tube with those of smooth tube, increasing of condensing heat transfer coefficient was found outstanding compared to the increasing ratio of pressure drop. Furthermore, pressure drop In U-bend showed at most a 30 % compared to the total pressure drop in the test section.

The Heat Transfer and Pressure drop Characteristics of R7l8 in Small Diameter Tubes (세관내 액단상의 열전달과 압력강하에 관한 연구)

  • 김세웅;홍진우;손창효;노건상;오후규
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.28-35
    • /
    • 2001
  • The heat transfer and pressure drop characteristics of R718 flowing in smooth horizontal copper tubes with inner diameter of 3.36 mm, 5.35 mm, 6.54 mm and 8.12 mm were investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. Experiments were peformed for the flowing range of variables : Reynolds number (1000 to 20000), mass flow rate of brine (450 kg/h) and refrigerant temperature (5$0^{\circ}C$). The main results were summarized as follows : (1) The heat transfer coefficient of 3.36 mm ID was about 10% to 30% higher than that of 5.35 mm, 6.54 mm and 8.12 mm ID, and the heat transfer coefficients for small diameter. tubes are about 20% to 27% higher than these predicted by Gnielinski. The new correlation is proposed to predict the experimental data. (2) As a result of comparison with correlation prosed by Blasius. the deviation of the experimental data slightly increased as the tube diameter decreased. (3) The ratio of heat transfer to friction factor (j/f) correlated by all experimental data increased as the tube diameter decreased.

  • PDF

A Study on the Thermal Performance of Fin and Tube Sensible Heat Exchanger according to Fin Geometry and Flowrate (휜 형상 및 유량에 따른 휜-관 현열 열교환기의 전열성능에 관한 연구)

  • Lee, Min-Su;Jeon, Chang-Duk;Lee, Jin-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.402-407
    • /
    • 2008
  • This study is performed to investigate heat transfer characteristics for thermal performance of fin-and-tube sensible heat exchangers under the low air flowrate according to fin geometry combination and coolant flowrate control. Fins and tubes of samples were separated between front row and rear row. Experiment results are plotted heat transfer rate of each row, heat transfer coefficient and sensible heat ratio against water flowrate control of each row. It is observed that thermal performance can be enhanced by fin geometry combination and water flowrate control of each row under the low air flowrate.

  • PDF

A Study on Correlation Between Acoustic Pressure and Heat Transfer Augmentation via Ultrasonic Vibration (초음파 진동 가진시 발생하는 압력과 열전달 촉진과의 상관관계에 관한 연구)

  • Oh Yool-Kwon;Yang Ho-Dong
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.22-25
    • /
    • 2004
  • The present paper investigated the correlation between acoustic pressure and heat transfer augmentation in acoustic fields. The acoustic pressure predicted by numerical work and compared with the augmentation ratio of heat transfer coefficient was experimentally measured. Also, particle image velocimetry(PIV) was used for the visualization of velocity vectors and kinetic energy distribution inside liquid region. For the numerical work, SVS programed with Fortran language and based on a coupled FE-BEM was used. Results of the present study, the acoustic pressure is increased by $60\%$ and the largest augmentation of heat transfer about $28\%$ was measured. Finally, the profiles of acoustic pressure is consistent with that of augmentation of heat transfer. It is concluded that a correlation exists between the acoustic pressure and the heat transfer augmentation.

  • PDF

Experimental Study on Condensation Heat Transfer Characteristics of Special Heat Transfer Tubes (응축용 특수 전열관의 열전달 특성에 관한 연구)

  • 한규일;박종운;권영철;조동현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.827-835
    • /
    • 2001
  • In this study, condensation heat transfer characteristics were conducted with special heat transfer tubes of SH-C type. Experiments were carried out the saturated vapor temperature of 334K and the wall subcooling of 1.5-4.5K. The refrigerant was R-113 and the enhanced tubes used in the present study were SH-CDR, SH-CYR and SH-CHR. The experimental results showed that the condensation heat transfer coefficients of SH-C type tubes were about 23-66% higher than those of a low integral-fin tube. It was visualized that the condensed liquid on the outer surface of SH-C type tubes flowed continuously down unlike a low integral-fin tube and a plain tube, due to a 3-D extending fin on the outer surface of SH-C type tubes. As a result, the thermal resistance of the condensed liquid decreased and the heat transfer coefficient increased. Also, the enhancement ratio of SH-CDR tube was the highest, and it was about 9-11 times as compared to that of a plain tube.

  • PDF