• Title/Summary/Keyword: Heat Stable

검색결과 1,281건 처리시간 0.032초

내열성장독소 생산 대장균의 판정 (Assay of Heat Stable Enterotoxin Producing E. coli)

  • 장우현;김문교;최명식;양남웅;고광욱;서정기
    • 대한미생물학회지
    • /
    • 제18권1호
    • /
    • pp.53-58
    • /
    • 1983
  • Enterotoxigenic E. coli is one of causative agents of the infantile diarrhea and traveler's diarrhea. A modified infant mouse assay(IMA) was developed for the detection of heat stable enterotoxin (ST) of E. coli isolated from diarrheal and control infants and assay system was established with using enterotoxin producing reference strains. The supernatant of the 24 hour-shaking culture of E. coli in Casamino Acid Yeast Extract Salt Broth(CYES-2) was ingested orally into the 2-4 day old ICR mice. After the mice were kept at $25^{\circ}C$ for 4 hours, they were sacrificed and the gut weight body weight ratio(GW/BW) was taken as the index of fluid accumulation induced by heat stable enterotoxin of E. coli. The results obtained were as follows; 1. The GW/BW responses of IMA tested with enterotoxin reference strains of E. coli(E. coli O148H28:$ST^+LT^+$, E. coli $O78H^-:ST^+LT^+$, E. coli O15H11:$ST^-LT^+$, E. coli O1H7:$ST^-LT^-$) appeared ta be ST dose-dependent, and not LT-dependent. From the dose-response curve, $25{\mu}l$ of culture supernatant was determined as test amount of the IMA. 2. Frequency distribution of IMA result from 643 strain of E. coli showed normal distribution at low GW/BW ratio and dispersed pattern at high GW/BW ratio. The GW/BW ratios of $0.056{\pm}0.004(mean{\pm}SD)$ of normal distribution which distributed from 0.044 to 0.068(P<0.01) was considered as ST negative. Thus the GW/BW ratio above 0.069 could be regarded as ST positive.

  • PDF

실측실험과 3차원 정상상태 열전달 해석을 통한 발열유리의 온도 및 전열량 분석 (Analysis of Temperature and Total Heat of Heated Glass through Experimental Measurement and Three-Dimensional Steady-State Heat Transfer Analysis)

  • 이도형;윤종호;오명환
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.111-116
    • /
    • 2015
  • Heat loss from windows and condensation occuring on its surface due to its lower insulation value causes much discomfort to occupants. In this study, Heated glass was used to make a basic study on prevention of condensation on glass surface for its heating functionality through experimental measurement and simulation analysis of total heat flux on the interior and exterior surface of glass. Error between experimental results and three dimensional steady-state heat transfer analysis were caused firstly, beacuse in the experimental chambers, cold chamber and steady temperature and humidity chamber, air temperature setting was not constant but rather ON/OFF control, and secondly, due to error rate in heat flux meter due to heat flux direction even in stable conditions.

A Boundary Element Solution Approach for the Conjugate Heat Transfer Problem in Thermally Developing Region of a Thick Walled Pipe

  • Choi, Chang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2230-2241
    • /
    • 2006
  • This paper presents a sole application of boundary element method to the conjugate heat transfer problem of thermally developing laminar flow in a thick walled pipe when the fluid velocities are fully developed. Due to the coupled mechanism of heat conduction in the solid region and heat convection in the fluid region, two separate solutions in the solid and fluid regions are sought to match the solid-fluid interface continuity condition. In this method, the dual reciprocity boundary element method (DRBEM) with the axial direction marching scheme is used to solve the heat convection problem and the conventional boundary element method (BEM) of axisymmetric model is applied to solve the heat conduction problem. An iterative and numerically stable BEM solution algorithm is presented, which uses the coupled interface conditions explicitly instead of uncoupled conditions. Both the local convective heat transfer coefficient at solid-fluid interface and the local mean fluid temperature are initially guessed and updated as the unknown interface thermal conditions in the iterative solution procedure. Two examples imposing uniform temperature and heat flux boundary conditions are tested in thermally developing region and compared with analytic solutions where available. The benchmark test results are shown to be in good agreement with the analytic solutions for both examples with different boundary conditions.

토양 및 지하수 조건이 지열공조시스템의 성능에 미치는 영향에 관한 수치 해석적 연구 (Numerical Analysis for the Effect of Ground and Groundwater Conditions on the Performance of Ground Source Heat Pump Systems)

  • 남유진
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.321-326
    • /
    • 2011
  • Recently, ground source heat pump (GSHP) systems have been introduced in many modem buildings which use the annually stable characteristic of underground temperature as one of the renewable energy uses. However, all of GSHP systems cannot achieve high level of energy efficiency and energy-saving, because their performance significantly depends on thermal properties of soil, the condition of groundwater, building loads, etc. In this research, the effect of thermal properties of soil on the performance of GSHP systems has been estimated by a numerical simulation which is coupled with ground heat and water transfer model, ground heat exchanger model and surface heat balance model. The thermal conductivity of soil, the type of soil and the velocity of groundwater flow were used as the calculation parameter in the simulation. A numerical model with a ground heat exchanger was used in the calculation and, their effect on the system performance was estimated through the sensitivity analysis with the developed simulation tool. In the result of simulation, it founds that the faster groundwater flow and the higher heat conductivity the ground has, the more heat exchange rate the system in the site can achieve.

수치해석을 통한 저심도 유닛형 지중열교환기의 성능 검토 (Performance Analysis of a Low-Depth Unit-Type Ground Heat Exchanger using Numerical Simulation)

  • 오진환;서장후;남유진
    • 설비공학논문집
    • /
    • 제27권3호
    • /
    • pp.169-173
    • /
    • 2015
  • Recently, ground source heat pump (GSHP) systems have attracted much attention, according to the enhanced social demand of renewable energy. GSHP systems can achieve higher coefficient of performance than the conventional air-source heat pump systems by utilizing stable underground temperature. However, the initial cost of GSHP system is higher than that of the conventional systems, especially, in the small-size buildings. Therefore, it is necessary to develop small-size ground heat exchanger with low cost and quick installation. In this study, a unit-type ground heat exchanger was developed and heat exchange rate was calculated by the numerical simulation. As a result, 27.45 W/m of heat exchange rate was acquired in the condition of $0.5m{\times}0.2m{\times}2m$ unit.

하천수 열원 열펌프 시스템의 성능 특성 및 경제성 평가 (Performance Characteristics and Economic Assessment of a River Water: Source Heat Pump System)

  • 박차식;정태훈;박홍희;김용찬
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.621-628
    • /
    • 2009
  • The objectives of this study are to analyze the performance of a river water-source heat pump and to carry out economic assessment for the heat pump. The COP of the river water-source heat pump was 3-21% higher than that of the air-source heat pump because river water provides stable operating temperature compared with air temperature throughout the year. The economic analysis was carried out by comparing the initial and operating cost of the river water-source heat pump with those of the conventional air-source heat pump. The ratio of the life cycle operating cost to the life cycle cost increased with the increase of building capacity. The payback period was found to be less than 3.5 years when the capacity of the river water-source heat pump was larger than 10 RT.

응축탱크로 방출되는 안정된 증기제트 응축모델 (Modeling on the Condensation of a Stable Steam Jet Discharging into a Quenching Tank)

  • 김환열;하광순;배윤영;박종균;최상민
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.349-356
    • /
    • 2001
  • 물과 증기의 직접접촉에 의한 응축 열전달은 움직이는 증기/물 경계면에서 열 및 물질 전달이 이루어지는 현상으로서, 매우 큰 열전달계수를 수반하는 특징이 있기 때문에 이를 응용한 설계가 산업계에서 광범위하게 이루어지고 있다. 본 연구에서는 단일 수평 배관을 통해 과냉각수가 있는 응축탱크로 안정된 증기제트가 방출될 때, 증기제트 형상을 예측하는 간단한 응축해석모델을 제시하였다. 해석모델은 축대칭 좌표계에서 질량, 운동량 및 에너지 방정식과 증기/물 경계면에서 의 응축 특성을 고려한 열평형 방정식을 사용하여 유도하였다. 증기/물 경계에서의 매우 큰 열전달율은 기존의 실험을 근거로 한 유효열전도계수에 의해 반영되었다. 해석결과는 실험결과와 비교하였고, 제시된 해석 모델은 실험에서 관찰된 바와 같이 증기 질량유속과 수조 온도가 증가할수록 증기제트 크기(반경 및 길이)가 증가하는 경향을 보였다.

  • PDF

감마선 조사에 의한 갈색 새우(Penaeus aztecus) 주요알러젠(Pen a 1)의 알러지성 및 항원성의 변화 (The Changes of Allergenic and Antigenic Properties of Major Allergen(Pen a 1) of Brown Shrimp(Penaeus aztecus) by Gamma Irradiation)

  • 이주운;김재훈;성창근;강근옥;신명곤;변명우
    • 한국식품과학회지
    • /
    • 제32권4호
    • /
    • pp.822-827
    • /
    • 2000
  • 새우 알러지를 감소시키기 위한 방법으로써 감마선 조사기술의 이용 가능성을 평가하였다. 새우로부터 분리한 열안정성 단백질(HSP)과 병원에서 임상진단용으로 사용하는 새우 단백질 추출액을 1, 3, 5, 7, 10 kGy의 선량으로 감마선을 조사하였다. 단백질 추출액 및 HSP의 알러지성과 항원성의 변화를 mAb와 환자의 IgE를 사용한 ELISA법과 immunoblotting법으로 측정하였고, 단백질의 구조변화는 gel permeation chromatography와 SDS-PAGE로 관찰하였다. 환자의 IgE는 감마선 조사된 단백질 추출액과 HSP용액 모두에서 감마선 조사선량이 증가함에 따라 감소하였다. GPC-HPLC와 sandwich ELISA법으로 HSP를 정량하였을 때도 역시 감마선 조사선량이 증가함에 따라 감소하였다. SDS-PAGE pattern 변화에서 HSP는 감마선 조사에 의해 변화되어 더 큰 분자량으로 전환되었다. 이러한 결과는 감마선 조사가 새우 알러지 억제에 적용 할 수 있다는 가능성을 시사하였다.

  • PDF

Analysis of the thermal management of a high power LED package with a heat pipe

  • Kim, Jong-Soo;Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권2호
    • /
    • pp.96-101
    • /
    • 2016
  • The thermal management of high-power LED components in an assembly structure is crucial for the stable operation and proper luminous function. This study employs numerical tools to determine the optimum thermal design in LEDs with a heat sink consisting of a crevice-type vapor-chamber heat pipe. The effects of the MCPCB are investigated in terms of the substrate thicknesses on which the LEDs are mounted. Further, different placement configurations in a system module are considered. This study found that for a confined area, a power of 40 W/LED is applicable to a high-power package. Furthermore, the thermal conductivity of dielectric layer materials should ideally be greater than 0.9 W/m.K. The temperature conditions of the vapor chamber in a heat pipe greatly affect the thermal performance of the system. At an offset distance of 9.0 mm and a $2^{\circ}C$ increase in the temperature of the heat pipe, the resulting maximum temperature increase is approximately $1.9^{\circ}C$ for each heat dissipation temperature. Finally, at a thermal conductivity of 0.3 W/m.K, it was found that the total thermal resistance changes dramatically. Above 1.2 W/m.K, the resistance change reduces exponentially.

가정용 열병합 발전을 위한 스털링 엔진의 열원 온도 및 냉각수 유량에 따른 성능 실험 (Performance Measurements of A Stirling Engine for Household Micro Combined Heat and Power with Heat Source Temperatures and Cooling Flow Rates)

  • 심규호;김민기;이윤표;장선준
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.37-43
    • /
    • 2015
  • A Beta-type Stirling engine is developed and tested on the operation stability and cycle performance. The flow rate for cooling water ranges from 300 to 1500 ml/min, while the temperature of heat source changes from 300 to $500^{\circ}C$. The internal pressure, working temperatures, and operation speed are measured and the engine performance is estimated from them. In the experiment, the rise in the temperature of heat source reduces internal pressure but increases operation speed, and overall, enhances the power output. The faster coolant flow rate contributes to the high temperature limit for stable operation, the cycle efficiency due to the alleviated thermal expansion of power piston, and the heat input to the engine, respectively. The experimental Stirling engine showed the maximum power output of 12.1 W and the cycle efficiency of 3.0 % when the cooling flow is 900 ml/min and the heat source temperature is $500^{\circ}C$.