• Title/Summary/Keyword: Heat Stable

Search Result 1,284, Processing Time 0.037 seconds

A Basic Study on the Development of Domestic Underwater Wet Arc Welding Electrode (습식 수중 아크용접봉의 국산화개발에 관한 기초연구)

  • 김민남;김복인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1122-1129
    • /
    • 2001
  • Underwater wet arc welding process was experimentally investigated by using the six types of flux coated electrodes of 3.2 mm diameter and the KR-RA steel plate of 11 mm thickness as base metal. Two types of electrodes were domestic covered arc welding electrode(CR13, CR14) and another two types of wet welding electrodes(UWCS, TN20)were imported goods, and the other two type (UWX1, UWX2) were individually designed flux coated electrodes for experimental welding purpose. Main experimental results are summerized as follows: 1. It is ascertained that individually designed flux coated electrode(UWX1) could be used in practice with KR-RA steel plate for underwater wet arc bead welds. 2. Welding arc can be generated easily and considerably kept in stable using TN20 and UWX1 electrodes. 3. The micro Vickers hardness value and the portion of martensite in the HAZ were increased in all the electrodes by rapid cooling rate, but it is relatively maintain stable for UWCS, TN20 and UWX1 electrodes.

  • PDF

A study of flow oscillations in a upright heated pipe (직립전열관에서의 유체진동에 관한 연구)

  • 박진길;진강규;오세준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.85-99
    • /
    • 1984
  • The stability of the two-phase flow in a heated channel is of great importance in the design and operation of the boilers and light water nuclear reactors, because it can cause flow oscillations and lead to a violation of thermal limits with resultant overheating of the channels and cladding. This paper presents a systematic evaluation to the variation effects of the basic four (4) dimensionless parameters in a homogeneous equilibrium model. The flow stability is examined on the ground of static characteristic curves. The complicated transfer function of flow dynamics which gives consideration to the transport lag of density wave is derived, and the transient flow stability is analysed by applying the Nyquist stability criterion in control engineering. The analysis results summed up as follows 1. The coolant flow becomes stable in large friction number and specific flow, while it is unstabale in small friction number and flow. 2. Large phase-change number and Froude number destabilize the two-phase flow, but small numbers stabilize it. The effect to variation of phase-change number is more dominant compared with Froude number. 3. The dynamic analysis is required to hold the sufficient safety of heated channels since only static results does not keep it. The special attention could be payed in the design and operation of heat engines, because the unstaable region exists within the stable boundary at small and middle phase-change number and Froude number.

  • PDF

Thermal Stability of Superconductor NdBCO Sintered at Various Oxygen Partial Pressures (다양한 산소분압에서 소결한 NdBCO 초전도체의 열적 안정성)

  • Chung, J.K.;Kim, W.J.;Park, S.C.;Kang, S.G.;Lim, Y.J.;Kim, C.J.
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.133-138
    • /
    • 2009
  • The $Nd_{1+x}Ba_{2-x}Cu_3O_{7-{\delta}}$(Nd123) superconductor exhibits high performance in high magnetic field and high temperature. We have studied phase stability for Nd123 under reduced oxygen partial pressure and various heat-treatment conditions. The main phase is Nd123 and some samples contain small amounts of Nd422 depending on the temperature and oxygen partial pressure. The decomposition temperature decreases with decreasing oxygen partial pressure from $1052^{\circ}C(P(O_2)$=150 Torr) to about $845^{\circ}C(P(O_2)$=0.1 Torr). The liquidus line was steeper temperature with decreasing oxygen partial pressure. In same condition of oxygen partial pressure, the region of stable Nd123 phase was formed at slightly higher temperature than the region of stable YBCO phase.

  • PDF

Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator (국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 -)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF

Fabrication and characterization of silicon-based microsensors for detecting offensive $CH_3SH\;and\; (CH_3)_3N$ gases

  • Lee, Kyu-Chung;Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2008
  • Highly sensitive and mechanically stable gas sensors have been fabricated using the microfabrication and micromachining techniques. The sensing materials used to detect the offensive $CH_3SH$ and $(CH_3)_3N$ gases are 1 wt% Pd-doped $SnO_2$ and 6 wt% $Al_2O_3$-doped ZnO, respectively. The optimum operating temperatures of the devices are $250^{\circ}C$ and $350^{\circ}C$ for $CH_3SH$ and $(CH_3)_3N$, respectively and the corresponding heater power is, respectively, about 55mW and 85mW. Excellent thermal insulation is achieved by the use of a double-layer membrane: i.e. $0.2{\mu}m$-thick silicon nitride and $1.4{\mu}m$-thick phosphosilicate glass. The sensors are mechanically stable enough to endure the heat cycles between room temperature and $350^{\circ}C$, at least for 30 days.

Studies on a Micro Reformer System with a Two-staged Microcombustor (초소형 2단 연소기를 이용한 리포머 시스템에 관한 연구)

  • Kim, Ki-Baek;Lee, Jung-Hak;Kwon, Oh-Chae
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.3
    • /
    • pp.217-225
    • /
    • 2008
  • A new micro reformer system consisted of a micro reformer, a microcombustor and a micro evaporator was studied experimentally and computationally. In order to satisfy the primary requirements for designing the microcombustor integrated with a micro evaporator, i.e. stable burning in a small confinement and maximum heat transfer through a wall, the present microcombustor is simply cylindrical to be easily fabricated but two-staged (expanding downstream) to feasibly control ignition and stable burning. Results show that the aspect ratio and wall thickness of the microcombustor substantially affect ignition and thermal characteristics. For the optimized design conditions, a premixed microflame was easily ignited in the expanded second stage combustor, moved into the smaller first stage combustor, and finally stabilized therein. A micro reformer system integrated with a modified microcombustor based on the optimized design condition was fabricated. For a typical operating condition, the designed micro reformer system produced 22.3 sccm hydrogen (3.61 W in LHV) in an overall efficiency of 12%.

Anti Oralmicrobial Activity of Various Extracts from Parts of Lotus (Nelumbo nucifera) (구강위생균에 대한 연(Nulumbo nucifera)의 부위별.용매별 항균활성)

  • Lee, Eun-Soo;Han, Young-Sook
    • Korean journal of food and cookery science
    • /
    • v.27 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • Anti oralmicrobial effects of Nulembo nucifera were determined against S.mutans, S.sobrinus S.sobrinus, F.nucleatum, and A.actinomycetemcomitans using paper disc method, minimum inhibitory concentrate (MICs). Extracts of lotus leaf showed the highest yield. MeOH extract is 21%, Chloroform fraction is 4.2%, ethylacetate fraction is 8.2%, water fraction is 19%. Different parts such as flower, leaf, seed and pod showed antimicrobial effects against S.mutans, with flower and seed extracts showing strong antimicrobial effect aganinst S.sobrinus KCCM11897. Leaf extract(1000pm concentration) showed over 50% inhibitory effect against S.mutans and S.sobrinus KCCM11897. Flower extract showed over 40% inhibitory effect against F.nucleatum and A.actinomycetemcomitans. MICs of flower extract against S.sobrinus KCCM11897,11898 and leaf extract against S.mutans, S.sobrinus KCCM11897 were $625\;{\mu}g/ml$, indicating Nulembo nucifera extract can exert antimicrobial activity even at low concentration. All extractes with heat at $120^{\circ}C$ had antimicrobial activity, which means that is a very stable substances. F.nucleatum and A.actinomycetemcomitans was stable against acid it had a trend that the more akali side was the lower acitivity.

An Investigation of the Effect of Changes in Engine Operating Conditions on Ignition in an HCCI Engine

  • Lee, Kyung-Hwan;Gopalakrishnan, Venkatesh;Abraham, John
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.10
    • /
    • pp.1809-1818
    • /
    • 2004
  • The dependence of the ignition timing in an HCCI engine on intake temperature and pressure, equivalence ratio, and fuel species is investigated with a zero-dimensional model combined with a detailed chemical kinetics. The accuracy of the model is evaluated by comparing measured and computed results in a propane-fueled HCCI engine. It is shown that the peak pressure values are reproduced within 10% and ignition timing within 5$^{\circ}$ CA. The heat loss through the walls is found to affect significantly on the ignition timing for different inlet conditions. It is also shown that for the propane-fueled engine, the tolerance in intake temperatures is 20-25K and the tolerance in intake pressure is about 1 bar for stable operation without misfire or too early ignition. Comparison of propane and heptane fuels indicates that the tendency to misfire when heptane is employed as the fuel is less than that when propane is employed with the same wall temperature conditions. However, the heptane-fueled engine may have a lower compression ratio to avoid too early ignition and hence lower efficiency. For the selected set of engine parameters, stable operations might be achieved for the heptane-fueled engine with twice as much tolerance in intake temperatures as for the propane-fueled engine.

Processing Conditions of Low-Salt Fermented Squid and Its Flavor Components 3. Characterization of Protease Produced by Pseudomonas D2 Isolated from Squid Jeotkal (저염 오징어젓갈 제조 방법 및 향미 성분 3. 오징어젓갈에서 분리한 Pseudomonas D2가 생성하는 Protease의 효소학적 특성)

  • 허성호;이호재;김형선;최성희;김영만
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.4
    • /
    • pp.636-641
    • /
    • 1995
  • Proteolytic activities were compared using three species involving in squid jeotkal fermentation and showing positive reaction upon casein test : Pseudomonas D2, Flavovacterium odoratum and Acinetobacter calcoaceticus. Pseudomonas D2 produced highest activity of protease at 72h when incubated in our own modified medium(polypeptone, 0.5% ; tryptone, 0.5% ; NaCl, 3% ; pH, 7.5). Thus, this specie was selected for the further study. The growth pattern was coincided with the production of protease. Thus purification of protease was proceeded by ethanol precipitation, sephadex G-100 gel filtration, and DEAE sepharose ion exchange chromatography. The purified protease showed highest activity at pH 7.0 and 5$0^{\circ}C$. The enzyme was very stable over the wide ragnes of the temperature ; even with one hour heat treatment at 7$0^{\circ}C$, the enzyme showed substantial amount of the activity toward casein. In addition, the enzyme was stable over the wide range of pH. Molecular weight of the protease was determined to be 17.4 kD by SDS-PAGE.

  • PDF

Study on the Properties of Field Applied Non-Curing Concrete in Winter Season (동절기 무양생 콘크리트의 현장적용 성능 평가에 관한 연구)

  • Yoo, Jo-Hyeong;Kim, Woo-Jae;Hong, Seok-Beom;Kim, Hyeong-Cheol;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.413-419
    • /
    • 2016
  • In the cold-weathering concrete construction, it is important to ensure stable strength development of concrete in a low temperature environment. In this study, Non-curing cement(NCC) using the classified high fineness cement and self-heating powder was investigated for stable strength development without curing in a low temperature environment (less than $0^{\circ}C$). The actual size Mock-Up tests by various cement type and curing condition are performed to evaluate the strength development and hydration heat of concrete.