• 제목/요약/키워드: Heat Run Test

검색결과 34건 처리시간 0.032초

잠호용접의 용접재료 및 입열량에 따른 저온 충격성능의 실험적 고찰 (Experimental study for Charpy impact property according to change of welding consumable & heat input at submerged arc welding)

  • 남성길;장태원;윤동렬;권창길;박창국
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.138-140
    • /
    • 2004
  • In case of applying offshore standard of some class societies, the required impact test temperature is lower than that of class rule to be applied for general commercial ship. This study is performed to consider whether the impact value to be required at offshore standard of BV can be obtained or not under SAW method, 1 run both side welding, to be mainly used for butt joint of plates at domestic ship builder.

  • PDF

An Experimental Investigation of Heat Transfer in Forced Convective Boiling of R 134a, R 123 and R 134a/R 123 in a Horizontal Tube

  • Lim, Tae-Woo;Kim, Jun-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • 제18권3호
    • /
    • pp.513-525
    • /
    • 2004
  • This paper reports an experimental study on flow boiling of pure refrigerants R l34a and R l23 and their mixtures in a uniformly heated horizontal tube. The flow pattern was observed through tubular sight glasses with an internal diameter of 10㎜ located at the inlet and outlet of the test section. Tests were run at a pressure of 0.6 MPa in the heat flux ranges of 5-50㎾/㎡, vapor quality 0-100 percent and mass velocity of 150-600㎏/㎡s. Both in the nucleate boiling-dominant region at low quality and in the two-phase convective evaporation region at higher quality where nucleation is supposed to be fully suppressed, the heat transfer coefficient for the mixture was lower than that for an equivalent pure component with the same physical properties as the mixture. The reduction of the heat transfer coefficient in mixture is explained by such mechanisms as mass transfer resistance and non-linear variation in physical properties etc. In this study, the contribution of convective evaporation, which is obtained for pure refrigerants under the suppression of nucleate boiling, is multiplied by the composition factor by Singal et al. (1984). On the basis of Chen's superposition model, a new correlation is presented for heat transfer coefficients of mixture.

수평 T형 증발관내 2상류의 유량분배 및 압력강하 특성 (Characteristics of T-phase flow distribution and pressure drop in a horizontal T-type evaporator tube)

  • 박종훈;조금남;조홍기
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.658-668
    • /
    • 1999
  • The objective of the present study is to investigate the effect of experimental parameters on the hydrodynamic characteristics in a horizontal tee-type evaporator using R-22. The experimental apparatus consisted of an unheated tee-type test section, a liquid-vapor separator, a preheated, mass flow meters, a plate heat exchanger, pump, and other measurement devices. The experimental parameters were mass flux(500 and 600kg/$m^2$s), inlet quality(0.1~0.3) and separation ratio(0.3~0.7). Absolute pressure at the inlet of the test section was 0.652 MPa. The branch-to-inlet inner diameter ratio was 0.61. Pressure gradient at the branch section was larger than that at the run section at the same separation ratio. Pressure drop per unit length increased at the run section and decreased at the branch section as the separation ratio increased. Pressure drop predicted by the separated flow model agreed with experimental data within -35 to +16%. Generally, predicted values showed similar trend with the data. Mass flow ratio of vapor refrigerant was affected by the inlet quality more than the mass flux.

  • PDF

Varestraint Test법에 의한 Al-Li합금의 용접성 평가 (An Evaluation on the Weldability of Al-Li Alloys by Varestraint Testing Method)

  • 김형태;이창배;신현식;서창제
    • Journal of Welding and Joining
    • /
    • 제14권6호
    • /
    • pp.48-57
    • /
    • 1996
  • The weldability of high purity aluminum-lithium binary alloys has been investigated using the Varestraint test. Autogenous GTAW (gas-tungsten-arc-welds) were run along specimens of different lithium concentration using three sets of welding parameters. Welding voltage was held constant at 10 volts. Welding current (70∼100 amps) and travel speed (23∼33 cm/min) were the parameter varied. Hot-tearing susceptibility varied with lithium content and exhibited a steep peak at 2.6 weight percent lithium. Depth of penetration increased with increasing heat input and lithium concentration. The susceptibility is influenced by the wettability of dendrites by the interdendritic eutectic liquid as well as the time available for back-Siting by eutectic liquid. The welding condition of welding current 70A and travel speed 23 cm/min was showed good resistance to cracking in aluminum-lithium alloys. Suggestions for improving weld cracking resistance are also provided.

  • PDF

수평 전열관내 유동비등하는 순수냉매와 혼합냉매의 열전달 특성에 관한 연구 (A Study on Heat Transfer Characteristics in Flow Boiling of Pure Refrigerants and Their Mixtures in Horizontal Tube)

  • 임태우;한규일
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.144-151
    • /
    • 2003
  • An experimental study was carried out in a uniformly heated horizontal tube to examine heat transfer characteristics of pure refrigerants, R134a and R123, and their mixtures during flow boiling. The flow pattern was also observed through tubular sight glasses with an internal diameter of 10 mm located at the inlet and outlet of the test section. Tests were run at a pressure of 0.6 MPa and in the heat flux ranges of 5~100 kW/$m^2$, vapor Quality 0~100 percent and mass velocity of 150-600 kg/$m^2$s. The observed flow patterns were compared to the flow pattern map of Kattan et al., which predicted well the present data over the entire range of mass velocity employed in this study. Heat transfer coefficients of the mixture were less than the interpolated values between pure fluids both in the low quality region where the nucleate boiling is dominant and in the high quality region where the convective evaporation is dominant.

LP가스 폭발로부터 화재로의 천이에 관한 연구 (A Study on the Explosion to Fire Transition Phenomena of Liquidfied Petroleum Gas)

  • 오규형;이춘하
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.107-113
    • /
    • 1993
  • Small rectangular explosion chamber of its size 25cmX25cmX32cm with a circular bursting diaphram at the top was used to study the mechanism of gas explosion to fire transition phenomena, the process of ignition of solid combustibles during a gas explosion. To visulize the explosion to fire transition phenomena, transparent acryl window and high speed camera system were used. The test piece of solid combustible in this experiments was a 5cm$\times$5cm square sheet of newspaper which was placed in the explosion chamber filled with a LPG-air mixture. The mixture was ignited by an electric spark at the center of the chamber. Explosion to fire transition phenomena and the behavior of out flow and in flow of gas through the opening yielded by bursting the diaphram was visualized with shlieren system and without shlieren system. Diameter of a bursting dlaphram at the top of the explosion chamber was varied 5cm, 10cm, and 15cm, and the position of test piece were varied with 6 point. Explosion pressure was measured with strain type pressure transducer, and the weight difference of the test piece before and after each experimental run was measured. By comparing the weight difference of solid combustibles before and after the experiment and the behavior of out flow and inflow of gas after explosion, it was found that the possibility of ignition was depends on the LPG-air mixture concentration and the exposure period of test piece to the burnt gas. Test result of this experiments it was found that the main factor of this phenomena are that heat transfer to the test piece, and the pyrolysis reaction of test piece. Based on the results, the mechanism of the explosion to fire transition phenomena were inferred ; gas explosion- heat transfer to solid combustibiles ; pyrolysis reaction of solid combutibles : air inflow ; mixing of the pyroly gas with air ignition.

  • PDF

마이크로 렌즈 연삭기용 주축설계 및 제작에 관한 기초연구 (A Basic Study of High Precision Spindle Design for Micro-Glass Lens Grinding)

  • 김의중;한정훈;박상일;송승훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2002
  • The high precision spindle is essential fer mass and low cost production of aspherical glass lens. Especially, in the grinding process of micro glass lens the performance of the spindle determine the machined surface quality. For the aspheric micro glass lens grinding, we design and make a high precision spindle. We use air bearings for high speed and low motion errors of the spindle. And the driving mechanism is an air turbine to remove heat generation. In this study, we make basic performance requirements of the spindle through benchmarking. And we confirm the requirements by basic machining test. We test air consumption, static stiffness, run-out and vibration of the spindle.

  • PDF

R-502 대체 혼합냉매의 성능에 관한 실험적 연구 (Experimental study on the performance of R-502 alternative refrigerant mixtures)

  • 박동민;정동수;김종보;강득주
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.198-209
    • /
    • 1997
  • This paper is concerned about the performance of alternative refrigerants of R-502 which has been widely used in transport and low temperature refrigeration. A breadboard heat pump was constructed with counterflow heat exchangers and tested with R-502 and transitional alternatives of R-402A and R-402B and long-term alternatives of R-404A and R-507 to compare the performance of each refrigerant. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$ and $52.0^{\circ}C$ and the evaporating temperature was varied over a range from $-25^{\circ}C$ to $-5^{\circ}C$. The evaporator superheat and condenser subcooling were maintained constant at about $5^{\circ}C$ for all tests. Test results showed that all alternative fluids tested in this research work can be used as 'drop-in' fluids to replace R-502 without any major problem. It is also found that in the long run HFC alternatives are to be used due to their favorable environmental characteristics and better performance.

  • PDF

S.I. 엔진의 사이클 시뮬레이션 및 이의 확인 실험 (A cycle simulation of the S.I. engine and it's verification test)

  • 목희수;김승수
    • 오토저널
    • /
    • 제10권6호
    • /
    • pp.72-84
    • /
    • 1988
  • Engine performance is one of the main objectives specified at the beginning of a new engine design project. The cycle simulation for SI engine is based on the zero-dimensional gas exchange model and a heat release expression by Viebe. This program also requires minimum input data and takes only a short time to run. Heat transfer from cylinder transfer formula. The flow coefficient (effective area) is calculated from valve lift using the standard flow coefficient curve and engine friction is calculated from the Millington and Hartles' engine friction formula. The chemical species considered in burned gas are 6 species CO, CO, H$_{2}$, H$_{2}$O, $O_{2}$, N$_{2}$ and the cylinder pressure, homogeneous cylinder temperature, gas composition and burned fraction are calculated at each crank angle through the cycle. To check the validity and accuracy, experimental study was done with 3 engines for measuring cylinder pressure, indicated mean effective pressure, brake mean effective pressure and air flow rate, etc. Despite its simple assumptions, cycle simulation showes excellent breathing and performance correlation when compared with data of tested engines, and have been proved useful in engine design.

  • PDF

Assessment of COBRA-TF for Critical Heat Flux

  • Chun, Tae-Hyun;Lim, Jong-Sun;Motoaki Okazaki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.75-81
    • /
    • 1996
  • COBRA-TF is a two fluid, three field subchannel code. Three fields are continuous vapor, continuous liquid and droplet. Some assessments are conducted to validate the related models and to estimate a code ability through dryout and post-CHF experiment in a tube and DNB test in rod bundles. It turned out form dryout and post-CHF experiment that the predicted dryout locations and wall temperature profiles are in close agreement with the experiments. On the other hand, DNB prediction of COBRA-TF are performed for two kinds of rod bundles along with EPRI CHF correlation. To estimate its performance COBRA-IV of homogeneous model is also run for the same data. The results say that COBRA-TF/EPRI is better in DNB prediction than COBRA-IV/EPRI. In addition the thermal-hydraulic behaviors due to the different two-phase flow models are presented at the condition of CHF.

  • PDF