• 제목/요약/키워드: Heat Reservoir

검색결과 90건 처리시간 0.026초

충전율의 변화가 밀폐형 2-상 열사이폰의 열전달 특성에 미치는 영향에 관한 연구 (The Effect of the Fill Charge Ratio on the Heat Transfer Characteristics of a Two-Phase Closed Thermosyphon)

  • 박용주;홍성은;김철주
    • 대한기계학회논문집B
    • /
    • 제26권12호
    • /
    • pp.1646-1654
    • /
    • 2002
  • A two-phase closed thermosyphon was one of the most effective devices in the removing heat because of its simple structure, thermal diode characteristics, wide operating temperature range and so on. In this study, a two-phase closed thermosyphon(working fluid PFC(C6F14), container copper(inner grooved surface)) was fabricated with a reservoir which can change the fill charge ratio. The experiments were performed in the range of 50~600W heat flow rate and 10~70% fill charge ratio. The results were compared with some correlations that were presented by Rohsenow and Immura et al. in the evaporator, by Nusselt, Gross and Uehara et al. in the condenser and by Cohen and Bayley, Wallis, Kutateladze and Faghri et al. in heat transfer limitation etc.. The heat transfer coefficient at the evaporator increased with the input power. However the effect of the fill charge ratio was nearly negligible. At the condenser, it showed an opposite trend to the evaporator and with increase of the fill charge ratio, showed some enhancement of heat transfer. The heat transport limitation was occurred by the dry-out limitation for small fill charge ratio(10%) and presented about 100W. For the case of large fill charge ratio(Ψ$\geq$40%), it was occurred by the flooding limitation at about 500W.

Temperature distribution during heavy oil thermal recovery considering the effect of insulated tubing

  • Zhang, Songting
    • Geomechanics and Engineering
    • /
    • 제19권6호
    • /
    • pp.523-532
    • /
    • 2019
  • Based on the formation characteristics, wellbore parameters and insulated tubing (IT) parameters of the Shengli oilfield, Shandong, China, a geomechanical model is built to predict the temperature distributions of the wellbore and formation. The effects of the IT heat conductivity coefficient (HCC), well depth and IT joint on the temperature distribution of the IT, completion casing, cement sheath, and formation are investigated. Results show the temperature of the formation around the wellbore has an exponentially decreasing relation with the distance to the wellbore. The temperature of the formation around the wellbore has an inverse relation with the IT HCC when the temperatures of the steam and the formation are given. The temperature of the casing outer wall is mainly determined by the steam temperature and IT HCC rather than by the initial formation temperature. The temperature of the casing at the IT joint is much larger than that of the other location. Due to the IT joint having a small size, the effects of the IT joint on the casing temperature distribution are limited to a small area only.

Basel EGS Project의 미소진동관리 사례연구 (Case Study of Microseismic Management Systems for Basel EGS Project)

  • 이상돈
    • 터널과지하공간
    • /
    • 제23권6호
    • /
    • pp.572-580
    • /
    • 2013
  • 이 사례연구에서는 스위스 바젤에서 진행되었던 인공지열발전(EGS) 프로젝트인 Deep Heat Mining Basel(DHMB)의 미소진동 관리시스템을 살펴보았다. 인공지열발전 프로젝트에 꼭 필요한 인공지열저류층 생성을 위한 수리자극으로 인해 발생하는 유도진동은 안전관리시스템을 수립하여 수리자극의 압력과 유량을 관리하여야 한다. DHMB프로젝트에서는 수리자극 기간 동안 지속적인 관측활동을 통해 미소진동 발생 진도에 따라 단계별로 대응하는 경보시스템과 커뮤니케이션 대응 절차가 사전에 수립되어 관리되었다. 그러나 수리자극을 위한 주입 완료 후에도 지열저류층에서 발생한 주입이후 진동현상으로 인해 예상보다 큰 지진이 발생하자 프로젝트가 중단되었다. 사후분석 결과 실시간 경보시스템은 주입이후 진동 현상을 감안한 새로운 미소진동 안전관리시스템을 수립하는 것이 필요하다고 확인되었다.

HSPF 유역모델을 이용한 낙동강유역 실시간 수온 예측 (Operational Water Temperature Forecast for the Nakdong River Basin Using HSPF Watershed Model)

  • 신창민;나은혜;김덕길;김경현
    • 한국물환경학회지
    • /
    • 제30권6호
    • /
    • pp.673-682
    • /
    • 2014
  • A watershed model was constructed using Hydrological Simulation Program Fortran to predict the water temperature at major tributaries of Nakdong River basin, Korea. Water temperature is one of the most fundamental indices used to determine the nature of an aquatic environment. Most processes of an aquatic environment such as saturation level of dissolved oxygen, the decay rate of organic matter, the growth rate of phytoplankton and zooplankton are affected by temperature. The heat flux to major reservoirs and tributaries was analyzed to simulate water temperature accurately using HSPF model. The annual mean heat flux of solar radiation was estimated to $150{\sim}165W/m^2$, longwave radiation to $-48{\sim}-113W/m^2$, evaporative heat loss to $-39{\sim}-115W/m^2$, sensible heat flux to $-13{\sim}-22W/m^2$, precipitation heat flux to $2{\sim}4W/m^2$, bed heat flux to $-24{\sim}22W/m^2$ respectively. The model was calibrated at major reservoir and tributaries for a three-year period (2008 to 2010). The deviation values (Dv) of water temperature ranged from -6.0 to 3.7%, Nash-Sutcliffe efficiency(NSE) of 0.88 to 0.95, root mean square error(RMSE) of $1.7{\sim}2.8^{\circ}C$. The operational water temperature forecasting results presented in this study were in good agreement with measured data and had a similar accuracy with model calibration results.

소결금속 윅과 메탄올을 사용하며 바이패스라인이 부착된 루프히트파이프의 작동 특성 (Operating Characteristics of a Sintered-Metal Wick/Methanol Loop Heat Pipe Having a Bypass Line)

  • 부준홍;정의국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2130-2135
    • /
    • 2007
  • Operating characteristics of a loop heat pipe (LHP) having a bypass line was investigated experimentally. The LHP had a sintered metal wick as a capillary structure and methanol as a working fluid. The sintered metal wick was made of stainless steel of which the average pore size was 5 ${\mu}m$and porosity of 47%. A bypass line of a small diameter was attached between the vapor escape passage and the liquid reservoir. The dimension of the flat evaporator was $50(L){\times}40(W){\times}30(H)$ mm and that of the condenser was $50(L){\times}40(W){\times}11(H)$ mm. Wall and pipe material of the LHP was stainless steel and heating area was 35(W) mm${\times}$35(L) mm. The inner diameters of vapor and liquid transport lines were 4.0 mm and 2.0 mm, and the lengths of the two lines were both 0.5 m. The LHP was tested for three different tilt angles of horizontal, favorite tilt, and adverse tilt. The thermal load range was up to 290 W at the condenser above evaporation position. Furthermore, the effect of a bypass line on the start-up transient as well as steady-state operation was presented and discussed.

  • PDF

1kW급 고체산화물 연료전지 발전시스템 자열운전 (Self-sustainable Operation of a 1kW class SOFC System)

  • 이태희;최진혁;박태성;유영성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2008
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 single cells and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen after pre-treatment process, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water.

  • PDF

분사냉각모듈 내에 부착된 히트싱크에 따른 고출력 LED의 냉각성능에 관한 연구 (Cooling Performance Study of a Impinging Water Jet System with Heat Sink for High Power LEDs)

  • 구건모;김경진;박상희;최성대;허정욱
    • 한국기계가공학회지
    • /
    • 제12권6호
    • /
    • pp.152-158
    • /
    • 2013
  • The purpose of this study is to investigate cooling performance of high power LEDs from 100 to 200 W class by using a jet impingement cooling module. The numerical analysis of forced convection cooling inside cooling module is carried out using a multi-purpose CFD software, FLUENT 6.3. In the experiments, the LED cooling system consists of jet impingement module, heat exchanger, water reservoir, and pump. In the present study, the cooling performance of jet impingement cooling module is investigated to determine the effect of the heat sink types on the impinging surface, the space and length of fins. Numerical and experimental studies show the reasonable agreement of LED metal PCB temperature between those results and give the optimized design parameters such as the space of fin and the length of fin. Also, the pin fin type of heat sink is found to be more efficient than the plate type heat sink in jet impingement cooling.

태양열을 이용한 무동력 냉난방 겸용장치의 특성 비교 연구 (Study on Characteristics Comparison of Unpowered Cooling and Heating Combined Device using Solar Heat)

  • 이재한;전태규;양영준
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.20-26
    • /
    • 2018
  • 지구온난화 현상이 세계적으로 점점 심각해지고 있으며 이에 대한 대책으로 에너지 원천의 다양화, 에너지 절감 기술 등이 필요하다. 본 연구에서는 태양열을 이용한 무동력 냉난방 겸용장치를 실현하기 위하여 태양열 집열기 흡수판의 재질변화, 무동력과 최소의 동력을 사용하였을 때의 특성을 비교하고자 하였다. 그 결과로서 하절기에 태양열 집열장치를 부착한 경우는 부착하지 않은 경우보다 실내온도가 약 $1^{\circ}C$ 낮았으며, 하절기에 냉원저장조가 없는 상태에서 태양열 집열장치에 의한 냉방효과는 적었다. 그러나 동절기에는 실내온도가 약 $3^{\circ}C$ 높았으며 무동력에 의한 난방효과의 가능성이 있었다. 간접적인 측정방법에 의해, Cu 재질의 태양열 집열장치의 성능은 Al 재질과 비교하여 약 2배 높았다.

태양열 집열관 과열방지를 위한 지중열교환기 연구 (A study of geothermal heat dump for solar collectors overheat protection)

  • 황현창;;이계복;이석호
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.616-622
    • /
    • 2016
  • 하절기 줄어드는 온수부하는 태양열 집열기 과열의 주된 원인이다. 과열방지목적으로 공냉 또는 차단막이 사용되는데 이는 추가적인 기계적요소를 필요하게 되고 장기 운용 시 파손 등의 우려에 따라 그 신뢰도도 크게 저하된다. 지중열교환기는 지열을 열원으로 방열 또는 흡열을 진행하는데, 지열을 고 열원으로 하여 흡열을 목적으로 하는 연구가 대다수이며 지열원이 저열원으로 이용하는 방열에 대한 연구는 부족한 편이다. 그리하여 본 연구에서는 태양열집열판의 과열방지를 목적으로 하는 지중열교환기의 가능성 및 그 성능에 대한 연구를 진행하였다. 여름철 최대 $150^{\circ}C$이상의 고온을 유지하는 태양열집열판의 열을 방출하기 위하여 1.2m의 하부 깊이를 갖는 50m 나선형 지중열교환기를 설치하였고 이를 통해 순간 냉각이 가능한 것으로 확인되었으며, 태양열집열판의 여름철 과열에 의한 파손을 방지할 수 있었다. 그리고 다양한 변수에 대한 이론적인 계산을 통하여 0.33kg/s의 최저 순환유량만 유지해주면 지열 열교환기의 길이에 따른 방열효과에 큰 영향을 미치지 않음을 판단할 수 있다. 또한 축열조와의 공동 사용시 냉각효과는 여름철 과열시 충분한 과열방지 제어가 가능한 것으로 조사되었다.

시간 경과에 따른 저류층 압력 상승이 파이프라인, 탑사이드 및 주입정 내 CO2 거동에 미치는 영향에 대한 수치해석적 연구 (Numerical Analysis of CO2 Behavior in the Subsea Pipeline, Topside and Wellbore With Reservoir Pressure Increase over the Injection Period)

  • 민일홍;허철;최윤선;김현욱;조맹익;강성길
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제19권4호
    • /
    • pp.286-296
    • /
    • 2016
  • 해양 CCS는 화력발전소에서 배출되는 $CO_2$를 포집하여 해양 지중의 대수층이나, 고갈 유가스전까지 수송하여 저장하는 기술이다. 시간 경과에 따라 지중 저장소로 주입 및 저장되는 $CO_2$의 누적 양이 증가하며, 이는 저류층 압력의 상승을 동반한다. 저류층 압력의 상승은 수송 및 주입 시스템의 운전조건 변화를 유발한다. 따라서 초기 설계단계에서 이러한 사업시간의 경과에 따른 운전조건 변화를 반영한 분석이 요구된다. 본 연구에서는 국내 동해 대륙붕에 위치한 가스전을 $CO_2$ 저장소로 활용할 경우 시간 경과에 따른 해양 수송 및 주입 시스템 내 $CO_2$ 거동을 수치해석적 방법을 이용하여 분석하였다. 전체 시스템을 해저 파이프라인, 라이저, 탑사이드, 주입정으로 구성하고, 이를 OLGA 2014.1을 이용하여 모델링 및 해석하였다. 약 10년의 주입 운전기간동안 해저 파이프라인, 라이저, 탑사이드, 주입정에서의 $CO_2$ 압력과 온도, 상거동의 변화를 분석하였다. 이를 통해 해저 파이프라인 입구 압축기, 탑사이드 열교환기 및 주입정 정두 제어 등의 설계 방안을 제시하였다.