• 제목/요약/키워드: Heat Recirculation

검색결과 188건 처리시간 0.023초

열전달과 물질전달의 유사성에 관한 연구 (A study on the Analogy between Heat Transfer and Mass Transfer)

  • 유성연;노종광;정문기
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2624-2633
    • /
    • 1993
  • Mass transfer experiment by naphthalene sublimation method has great advantages in measurement of local transfer coefficients in the region of a three dimensional flow or for a model of complex geometry, which is considered to be very difficult with conventional heat transfer measurements. Mass transfer data obtained by naphthalene sublimation technique are converted to the heat transfer data through heat/mass transfer analogy. This analogy is valid for a simple or laminar flow, but new insight is needed when applying to a turbulent flow or complex flow such as separation, reattachment and recirculation, The purpose of this research is to investigate how geometries and flow conditions incorporate heat/mass transfer analogy. Mass transfer experiments are performed using naphthalene sublimation technique for a flat plate, a circular cylinder, and rectangular cylinders. And mass transfer data are compared with earlier heat transfer measurements for the same geometries. Usefulness of analogy relation between heat and mass transfer is examined with these results.

콜로게이트 열교환기와 평판형 열교환기의 열전달특성에 관한 실험적 연구 (Experimental Study on the Heat Transfer Characteristics in Corrugated and Flat Plate Type Heat Exchanger)

  • 박정훈;정용기;전충환;장영준;임혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.37-42
    • /
    • 2003
  • An experiment was performed to study heat transfer characteristics between corrugated heat exchanger and flat plate type one. While heat capacity(13.86kW) was provided constantly and the flow speed was varied from 2.8 to 17.9m/s, The temperature and the pressure drop were measured. Furthermore, Heat transfer coefficient, Colburn factor and Nusselt number were calculated using them. With increase of the flow speed for both exchangers, the coefficient and the pressure drop increased, but Colburn factor decreased. The coefficient, pressure drop and Colburn factor of the corrugated type were all higher than those of the flat one, which is due to the flow interruption with recirculation and reattachment of the corrugated type. The empirical correlations of Nusselt number were suggested for the tested two heat exchangers.

  • PDF

회전원판형 CVD 장치의 유동 재순환을 억제하는 출구부 형상 설계를 위한 전산해석 (A COMPUTATIONAL ANALYSIS FOR OUTLET SHAPE DESIGN TO SUPPRESS FLOW RECIRCULATION IN A ROTATING-DISK CVD REACTOR)

  • 박장진;김경진;곽호상
    • 한국전산유체공학회지
    • /
    • 제18권4호
    • /
    • pp.74-81
    • /
    • 2013
  • A numerical design analysis is conducted to search for an optimal shape of outlet in a rotating-disk CVD reactor. The goal is to suppress flow recirculation that has been found in a reactor having a sudden expansion of flow passage outside of the rotating disk. In order to streamline gas flow, the sidewall at which the flow in the Ekman layer is impinged, is tilted. The axisymmetric laminar flow and heat transfer in the reactor are simulated using the incompressible ideal gas model. For the conventional vertical sidewall, the flow recirculation forming in the corner region could be expanded into the interior to distort the upstream flow. The numerical results show that this unfavorable phenomenon inducing back flow could be dramatically suppressed by tilting the sidewall at a certain range of angle. The assessment of deviation in deposition rate based on the characteristic isotherm illustrates that the sidewall tilting may expand the domain of stable plug-like flow regime toward higher pressure. A physical interpretation is attempted to explain the mechanism to suppress flow recirculation.

모형 가스터빈 연소기에서 화염구조와 연소불안정 특성에 대한 실험적 연구 (An Experimental Study on Flame Structure and Combustion Instability Characteristics in Model Gas Turbine Combustor)

  • 박성순;김민기;윤지수;윤영빈
    • 한국추진공학회지
    • /
    • 제15권4호
    • /
    • pp.26-34
    • /
    • 2011
  • 스월러를 가진 천연가스 연료분사기가 장착된 희박 예혼합 연소기에서 화염구조의 일부분인 재순환 영역의 형성이 연소불안정에 미치는 영향에 대하여 실험적으로 연구를 진행하였다. PIV 계측기법으로 연소장에서의 화염의 안정화 그리고 불안정한 영역에서 유동장을 확인해본 결과 스월러에 의한 재순환 영역은 화염의 안정화 및 난류의 강도뿐만 아니라 재순환영역 형성의 크기에 따른 화염 재점화에도 영향을 미쳐 연소불안정 발생의 원인이 되는 열방출 섭동과 매우 밀접한 관계가 있음을 확인하였다.

모형 가스터빈 연소기에서 화염구조와 연소불안정 특성에 대한 실험적 연구 (An Experimental Study on Flame Structure and Combustion Instability Characteristics in Model Gas Turbine Combustor)

  • 박성순;김민기;윤지수;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.445-452
    • /
    • 2011
  • 스월러를 가진 천연가스 연료분사기가 장착된 희박 예혼합 연소기에서 화염구조의 일부분인 재순환 영역의 형성이 연소불안정에 미치는 영향에 대하여 실험적으로 연구를 진행하였다. PIV 계측기법으로 연소장에서의 화염의 안정화 그리고 불안정한 영역에서 유동장을 확인해본 결과 스월러에 의한 재순환영역은 화염의 안정화 및 난류의 강도뿐만 아니라 재순환영혁 형성의 크기에 따른 화염 재점화에도 영향을 미쳐 연소불안정 발생의 원인이 되는 열방출 섭동과 매우 밀접한 관계가 있음을 확인하였다.

  • PDF

플라스틱 판형 열교환기의 와류발생기에 관한 연구 (A Study on the Vortex Generators of Plastic Plate Heat Exchangers)

  • 오윤영;유성연;고성호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.107-110
    • /
    • 2002
  • The present study deals with CFD analysis of 'The vortex generators on plastic plate heat exchanger'. When a vortex generator is placed on the heat transfer surface, the flow gets more complex because it entails complicated three-dimensional flows such as separation, reattachment, and recirculation. CFX-5.4, a commercial code utilizing unstructured mesh, has been used as a computational method for solving RANS(Reynolds-Averaged Wavier-Stokes) equations, and the applied turbulence model is $k-{\varepsilon}$ model. In addition, those computational analyses were implemented under various conditions , with or without the vortex generator between two plates, the number, form and the size of vortex generator, and different attack of angle. From the calculated temperature, velocity and pressure distribution, vorticity, wall heat flux and so on under those conditions, this study shows the effect of vortex on heat transfer.

  • PDF

2차원 채널에서 사각봉을 이용한 난류열전달 증가에 대한 수치해석 (AUGMENTATION OF TURBULENT HEAT TRANSFER IN A CHANNEL USING A SQUARE ROD)

  • 김희영;박태선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.118-124
    • /
    • 2008
  • The characteristics of heat transfer in a two-dimensional channel obstructed by a square rod is investigated by a turbulence model. The computation is made for the six cases of different rod positions between channel walls. To analyze the wall heat transfer, the heat flux of channel walls is set as a constant value and the $k-{\epsilon}-f_{\mu}$ model is employed. Downstream the square rod, the flow recirculation region appear and they are varied by the rod position. The enhancement of the turbulent heat transfer to the wall is induced by the flow instability using a square rod. The averaged heat transfer rate is maximized at a specific rod position. Finally, the effects of square rod on unsteady flows are scrutinized with the frequency analysis.

  • PDF

수소 스파크점화 엔진의 저부하 운전에서 열효율 및 질소산화물 배출 개선을 위한 배기가스재순환과 과잉공기 전략 비교 (Comparison of Exhaust Gas Recirculation and Excess Air Strategies for Improving Thermal Efficiency and Reducing Nitrogen Oxides emissions in Hydrogen Spark-ignition Engines at Low-load Operation)

  • 박현욱;이준순;오승묵;이용규;김창업
    • 한국분무공학회지
    • /
    • 제29권2호
    • /
    • pp.60-67
    • /
    • 2024
  • This study compared exhaust gas recirculation (EGR) and excess air strategies for improving thermal efficiency and emissions of hydrogen combustion engines at low-load operation. The experimental investigation was conducted in a single-cylinder, heavy-duty engine under throttling and wide-open throttle (WOT) conditions. Although both EGR and excess air strategies reduced peak heat release rates and increased combustion durations, the net indicated thermal efficiencies were improved by reducing the pumping losses. Under the constraint of similar nitrogen oxides emissions, the EGR strategy had higher net indicated thermal efficiencies compared to the excess air strategy in throttling operation. However, the difference between their thermal efficiencies was reduced under WOT condition. The trend of reducing nitrogen oxides emissions according to the two strategies was similar.

100 MWe급 순산소연소 발전소 보일러계통 공정설계 및 운전변수 민감도 예측 (100 MWe Oxyfuel Power Plant Boiler System Process Design and Operation Parameters Sensitivity Analysis)

  • 백세현;고성호
    • 한국연소학회지
    • /
    • 제18권4호
    • /
    • pp.1-11
    • /
    • 2013
  • The oxy-fuel combustion is $CO_2$ capture technology that uses mixture of pure $O_2$ and recirculated exhaust as oxidizer. Currently some Oxy-fuel power plants demonstration project is underway in worldwide. Meanwhile research project for converting 125 MWe Young-Dong power plant to 100 MWe oxy-fuel power plants is progress. In this paper, 1 D process analytical approach was applied for conducting process design and operating parameters sensitivity analysis for oxy-fuel combustion of Young-Dong power plant. As a result, appropriate gas recirculation rates was 74.3% that in order to maintain normal rating superheater, reheater steam temperature and boiler heat transfer patterns. And boiler efficiency 85.0%, CPU inlet $CO_2$ mole concentration 71.34% was predicted for retrofitted boiler. The oxygen concentration in the secondary recycle gas is predicted as 27.1%. Meanwhile the oxygen concentration 22.4% and moisture concentration 5.3% predicted for primary recycle gas. As the primary and secondary gas recirculation increases, then heat absorption of the reheater is tends to increases whereas superheater side is decreased, and also the efficiency is tends to decrease, according to results of sensitivity analysis for operating parameters. In addition, the ambient air ingression have a tendency to lead to decline of efficiency for boiler as well as decline of $CO_2$ purity of CPU inlet.

대향류 확산화염의 고온공기 연소특성에 관한 수치해석 (A Numerical Analysis of the Characteristics with High Temperature Air Combustion in Counterflow Diffusion Flame)

  • 조은성;히데아키 코바야시;정석호
    • 한국연소학회지
    • /
    • 제8권4호
    • /
    • pp.9-14
    • /
    • 2003
  • High temperature air combustion technology has been utilized by using preheated air over 1100 K and excessive exhaust gas recirculation. Numerical analysis was performed to investigate the combustion characteristics with high temperature deficient oxygen air combustion by adopting a counterflow as a model problem accounting for detailed chemical kinetics. Methane($CH_4$) was used as a test fuel and calculated oxidizer conditions were low temperature high oxygen (300K, $X_{O2}=0.21$) and high temperature low oxygen (1300K, $X_{O2}=0.04$) conditions. The latter case showed that the flame temperature is lower than the former case and its profile showed monotonic decrease from oxidizer to fuel side, without having local maximum flame temperature at high stretch rate. Also, heat release rate was one order lower and it has one peak profile because of low oxygen concentration and heat release rate integral is almost same for stretch rate. High temperature low oxygen air combustion shows low NO emission characteristics.

  • PDF