• Title/Summary/Keyword: Heat Plate

Search Result 1,874, Processing Time 0.027 seconds

An experimental study on the heat transfer and turbulent flow of round jet impinging the plate with temperature gradient (온도구배를 갖는 평판에 대한 원형 충돌제트의 열전달 및 난류유동에 관한 실험적 연구)

  • 한충호;이계복;이충구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.855-860
    • /
    • 1999
  • An experimental study of jet impingement on the surface with linear temperature gradient is conducted with the presentation of the turbulent characteristics and the heat transfer rates measured when this jet impinges normally to a flat plate. The jet Reynolds number ranges from 30,000 to 90,000, the temperature gradient of the plate is 2~$4.2^{\circ}C$/cm and the dimensionless nozzle to plate distance(H/D) is from 6 to 10. The results show that the peak of heat transfer rate occurs at the stagnation point, and the heat transfer rate decreases as the radial distance from the stagnation point increases. A remarkable feature of the heat transfer rate is the existence of the second peak. This is due to the turbulent development of the wall jet. Maximum heat transfer rate occurs when the axial distance from the nozzle to nozzle diameter(H/D) is 8. The heat transfer rate can be correlated as a power function of Prandtl number, Reynolds number and the dimensionless nozzle to plate distance(H/D). It has been found that the heat transfer rate increases with increasing turbulent intensity.

  • PDF

Optimized Design of a Cold Plate Heat Sink using FEM and Optimization (유한요소법과 최적설계기법을 활용한 히트싱크 콜드 플레이트 최적 설계)

  • Hong, S.;Seo, H.;Kim, J.;Sim, J.;Hwang, J.
    • Transactions of Materials Processing
    • /
    • v.23 no.7
    • /
    • pp.419-424
    • /
    • 2014
  • In order to improve efficiency, an outdoor unit using a refrigerant cooling method is designed into many air conditioner systems. The heat exchanger is composed of a Cu tube and an plate. The optimal design for the cold plate is very important because the efficiency of the heat transfer depends on the contact area between the Cu tube and the cold plate. The current study focused on the design of the cold plate to obtain a uniform contact between the Cu tube and the cold plate. Both FE(finite element) analysis and optimization were used in the design. The contact area between the tube and plate was predicted and improved by 16% through the press forming simulations. The springback after press forming was also reduced when the optimized design parameters were used. To verify the validity of the optimal cold plate design, a verification test was conducted. As a result, the performance of the heat exchanger improved by 34% when compared to benchmarked products.

Heat flow Analysis of Heat Sink Using the Computational Simulation (전산모사를 이용한 히트싱크의 열 유동 해석)

  • Lim Song Chul;Chang Si Young;Kim Hyon Tae;Lee Dong Heon;Kang Kae Myung
    • Korean Journal of Materials Research
    • /
    • v.14 no.7
    • /
    • pp.522-528
    • /
    • 2004
  • Heat analysis of the plate type and wave type heat sink were carried out by using computational simulation. The heat resistance and air flow of two heat sink models were analysed according to natural and forced convection condition and positions of fan. When a fan was at the position of z-axis and y-axis in forced convection, the heat resistances of plate type heat sink were $0.17^{\circ}C/W$, and $0.28^{\circ}C/W$ respectively. In the case of wave type heat sink, they were $0.18^{\circ}C/W$ and $0.53^{\circ}C/W$. As the air flow velocities were averagely $0.386\;m/s\~3.269\;m/s$, air flow velocity of plate type heat sink was faster than that of wave type. In this experiment, it was observed that the plate type heat sink showed a good ability of heat radiation comparing with wave type one.

Analysis of Heat Transfer in Cooling of a Hot Plate by Planar Impingement Jet (평면충돌제트에 의한 고온 판 냉각과정의 열전달 해석)

  • Ahn, Dae-Hwan;Kim, Dong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.17-27
    • /
    • 2009
  • Water jet impingement cooling is used to remove heat from high-temperature surfaces such as hot steel plates in the steel manufacturing process (thermo-mechanical cooling process; TMCP). In those processes, uniform cooling is the most critical factor to ensure high strength steel and good quality. In this study, experiments are performed to measure the heat transfer coefficient together with the inverse heat conduction problem (IHCP) analysis for a plate cooled by planar water jet. In the inverse heat transfer analysis, spatial and temporal variations of heat transfer coefficient, with no information regarding its functional form, are determined by employing the conjugate gradient method with an adjoint problem. To estimate the two dimensional distribution of heat transfer coefficient and heat flux for planar waterjet cooling, eight thermo-couple are installed inside the plate. The results show that heat transfer coefficient is approximately uniform in the span-wise direction in the early stage of cooling. In the later stage where the forced-convection effect is important, the heat transfer coefficient becomes larger in the edge region. The surface temperature vs. heat flux characteristics are also investigated for the entire boiling regimes. In addition, the heat transfer rate for the two different plate geometries are compared at the same Reynolds number.

Experimental study on the performance of a brazed plate heat exchanger (용접식 판형 열교환기의 성능에 관한 실험적 연구)

  • Kim, Jong-Ha;Yun, Jae-Ho;Kwon, Oh-Kyung;Kim, Jong-Hun;Ryu, Hae-Sung;Lee, Chang-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.477-482
    • /
    • 2001
  • An experimental study on the performance evaluation of a brazed plate heat-exchanger with 10RT of normal cooling capacity has been carried out. In the present study, a brazed type plate heat exchanger was tested at a chevron angle $25^{\circ}$ with refrigerant R-22. Mass flux was ranged from $23\;to\;58kg/m^{2}s$ in condensation, and from $22\;to\;53kg/m^{2}s$ in evaporation. The heat transfer coefficient and pressure drop increased with the mass flux increases. The water side pressure drop increased with the cooling water flow rate and chilled water flow rate increases, while mass flux has little affect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

  • PDF

Augmentation of Heat Transfer on a Flat Plate with Impinging Water Jet (衝突水噴流 에 의한 熱傳達促進 에 관한 硏究)

  • 엄기찬;서정윤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.6 no.4
    • /
    • pp.301-307
    • /
    • 1982
  • The purpose of this investigation is to study heat transfer characteristics at a stagnation point on a flat plate caused by upward impinging water jet. At the stagnation point, heat transfer results by impinging water jet are being compared with the ones with supplementary water. Optimum supplementary water quantity are supplied in order to improve the effect of heat transfer for each nozzle-to-plate distance. As the nozzle outlet velocity increases, the heat transfer coefficient at stagnation point consequently increases. Changing the nozzle-to-plate distance, growth rate of heat transfer also varies accordingly. This optimum range of Reynolds number is obtained to improve heat transfer effect.

Flow and Heat Transfer Characteristics of Aluminum Foam Porous Fins (발포알루미늄 다공핀의 열유동특성)

  • 김서영;백진욱;강병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.511-518
    • /
    • 2000
  • The present experimental study investigates the impact of porous fins on the pressure drop and heat transfer characteristics in plate-fin heat exchangers. Systematic experiments have been carried out in a simplified model of a plate-porous fin heat exchanger at a controlled test environment. Comparison of performance between the porous fins and the conventional louvered fins has been made. The experimental results indicate that friction and heat transfer rate are significantly affected by permeability as well as porosity of the porous fin. The porous fins used in the present study show a similar air-side performance to the louvered fin. The correlations of friction and modified j-factor are also given for the design of the plate-porous fin heat exchanger.

  • PDF

The Study on Absorption Performance of a Plate-Fin Type Absorber (플레이트-휜형 흡수기의 흡수성능에 대한 연구)

  • 강인석;김남진;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.557-563
    • /
    • 2001
  • Small capacity gas absorption systems for cooling and heating have been favorably considered to reduce the seasonal imbalance of electrical loads and LNG consumption recently. A multifunctional plate-fin heat exchanger was adopted as an absorber and the performance was tested and analyzed to reduce the size and weight of the absorption heat pump. The test was performed using breadboard type ammonia absorption machine. The performance was compared with the plate type absorber and there was little difference in heat and mass transfer characteristics. The heat and mass transfer performance was a function of poor solution and vapor flow rates and the mass transfer was dependent on vapor flow rate more than heat transfer.

  • PDF

A Study on the Heat Transfer from a Flat Plate and the Heat Transfer Enhancement by the Vortex Generator (평판에서의 열전달 및 와류발생기에 의한 열전달 촉진에 관한 연구)

  • Yoo, Seong-Yeon;Song, Si-Young;Park, Jong-Hark
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1447-1452
    • /
    • 2003
  • Vortex is very interesting flow phenomena on the heat transfer enhancement. In the present study, naphthalene sublimation technique is used to determine the average and local mass transfer coefficients on the flat plate with vortex generator. A parametric study with Reynolds number and angle of attack is carried out to investigate the heat transfer enhancement. The heat transfer coefficients on the flat plate with rectangular type and delta type vortex generator are compared with those of the flat plate without the vortex generator. Comparing heat transfer coefficients between rectangular type and delta type vortex generator, rectangular type vortex generator has much higher value than delta type vortex generator at the same condition.

  • PDF

A Numerical Analysis of Flow and Heat Transfer in the Plate Heat Exchanger with Dimple (딤플형 판형 열교환기의 열유동 수치해석)

  • Ahn, Hyuk-Jin;Lee, Sang-Hyuk;Lee, Myung-Sung;Hur, Nahm-Keon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.121-125
    • /
    • 2008
  • In this study, the characteristics of internal flow and the heat transfer performance of dimpled plate heat exchanger were numerically investigated. For the numerical analysis, conjugate heat transfer method between cold fluid - plate - hot fluid was studied with appropriate boundary conditions. Velocity magnitude, temperature and pressure distribution were obtained from the simulation. Correlations for fanning f-factor and Colburn j-factor were obtained from numerical results and compared to the experimented data.

  • PDF