• Title/Summary/Keyword: Heat Loss

Search Result 2,089, Processing Time 0.03 seconds

Estimated Advection Heat in the East/Japan Sea

  • Han, In-Seong;Kang, Yong-Q;Kim, Bok-Kee;Seong, Ki-Tack
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.165-170
    • /
    • 2003
  • A significant surface net heat loss appears around the Kuroshio and the Tsushima Warm Current regions. The area where the surface heat loss occurs should require heat to be supplied by the current to maintain the long-term annual heat balance. Oceanic heat advection in these regions plays an important role in the heat budget. The spatial distribution of the heat supply by the Tsushima Warm Current near the surface was examined by calculating the horizontal heat supply in the surface layer of the East/Japan Sea, directly from historical sea surface temperature and current data. We have also found a simple estimation of the effective vertical scale of heat supply by the current to compensate net heat loss using the heat supplied by the current in the surface 10m layer. The heat supplied by the current for the annual heat balance was large in the Korea/Tsushima Strait and along the Japanese Coast, and was small in the northwestern part of the East/Japan Sea. The amount of heat supplied by the current was large in the northwestern part and small in the southeastern part of the East/Japan Sea. These features suggest that the heat supplied by the Tsushima Warm Current is restricted to near the surface around the northeastern part and extends to a deeper layer around the southeastern part of the East/Japan Sea.

  • PDF

Investigation of Heat Transfer in Microchannel with One-Side Heating Condition Using Numerical Analysis (수치 해석을 이용한 단일 마이크로채널의 단면 가열 조건의 열전달 특성에 관한 연구)

  • Choi, Chi-Woong;Huh, Cheol;Kim, Dong-Eok;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.986-993
    • /
    • 2007
  • The microchannel heat sink is promising heat dissipation method far high density electronic devices. The cross-sectional shape of MEMS based microchannel heat sink is limited to triangular, trapezoidal, and rectangular due to their fabrication method. And heat is added to one side surface of heat source. Therefore, those specific conditions make some complexity of heat transfer in microchannel heat sink. Though many previous research of conjugate heat transfer in microchannel was conducted, most of them did not consider heat loss. In this study, numerical investigation of conjugate heat transfer in rectangular microchannel was conducted. The method of heat loss evaluation was verified numerically. Heat distribution was different for each wall of rectangular microchannel due to thermal conductivity and distance from heat source. However, the ratio of heat from each channel wall was correlated. Therefore, the effective area correction factor could be proposed to evaluate accurate heat flux in one side heating condition.

The Optimized Design of a NPC Three-Level Inverter Forced-Air Cooling System Based on Dynamic Power-loss Calculations of the Maximum Power-Loss Range

  • Xu, Shi-Zhou;He, Feng-You
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1598-1611
    • /
    • 2016
  • In some special occasions with strict size requirements, such as mine hoists, improving the design accuracy of the forced-air cooling systems of NPC three-level inverters is a key technology for improving the power density and decreasing the volume. First, a fast power-loss calculation method was brought. Its calculation principle introduced in detail, and the computation formulas were deduced. Secondly, the average and dynamic power losses of a 1MW mine hoist acting as the research target were analyzed, and a forced-air cooling system model based on a series of theoretical analyses was designed with the average power loss as a heat source. The simulation analyses proves the accuracy and effectiveness of this cooling system during the unit lifting period. Finally, according to an analysis of the periodic working condition, the maximum power-loss range of a NPC three-level inverter under multi cycle operation was obtained and its dynamic power loss was taken into the optimized cooling system model as a heat source to solve the power device damage caused by instantaneous heat accumulation. The effectiveness and feasibility of the optimization design based on the dynamic power loss calculation of the maximum power-loss range was proved by simulation and experimental results.

RISK EVALUATION OF CARBON MONOXIDE IN COMPARTMENT FIRE

  • Kim, Kwang Il
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.66-76
    • /
    • 1997
  • In order to investigate the generation of carbon monoxide and heat loss of incomplete combustion in compartment fires, an experiment was conducted in a small scale compartment by using methanol as a fuel. The concentration of carbon monoxide and the toxicity parameter showed high values when the mass air - to - fuel stoichiometric ratio is under 1.0. The constitution of the combustion gas was showed to estimate it from the . The heat loss due to incompleteness of combustion is about one third of heat of combustion in case of under 1.0.

  • PDF

Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature (외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구)

  • Byun, Jae-Ki;Lee, Kyu-Ho;Cho, Young-Don;Shin, Jong-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

Study on the Development of Multi Heat Supply Control Algorithm in Apartment Building of District Heating Energy (지역난방 에너지 공동주택의 다중 열공급 제어 알고리즘 개발에 관한 해석적 연구)

  • Byun, J.K.;Choi, Y.D.;Park, M.H.;Shin, J.K.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.63-70
    • /
    • 2011
  • In the present study, we developed optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in group energy apartment. Heating load variation of group energy apartment building in accordance with outdoor air temperature was predicted by the correlation obtained from calorimeter measurements of whole households of apartment building. Supply water temperature and mass flow rate were conjugately controlled to minimize the heat loss rate through distribution pipe line. Group heating apartment located in Hwaseong city, Korea, which has 1,473 households divided in 4 regions, was selected as the object apartment for verifying the present heat supply control algorithm. Compared to the original heat supply system, 10.4% heat loss rate reduction can be accomplished by employing the present control algorithm.

A Study on the Heat Loss Effect of Steel Structure in a Refrigerator Mullion (냉장고 멀리언부 구조보강용 철구조물의 열손실 영향 연구)

  • Ha, Ji Soo
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.35-41
    • /
    • 2014
  • The present study has been carried out to reduce the heat loss from a refrigerator by numerical heat transfer analysis and temperature measurement experiment for the verification of heat transfer analysis result. To perform this purpose, two dimensional heat transfer analysis and measurement of temperature on the surface of freezer for the horizontal cross sectional plane of a refrigerator has been accomplished. From the present study, it could be seen that the steel support in the mullion near gasket region has a heat transfer characteristics which transfer outside heat well from the high temperature hotline and outside air to the inner refrigerator. The effect of removing steel support on the reducing heat loss of a refrigerator was 24.8% and removing steel support might introduce significant improvement of refrigerator heat loss.

Differential expression of heat shock protein 90, 70, 60 in chicken muscles postmortem and its relationship with meat quality

  • Zhang, Muhan;Wang, Daoying;Geng, Zhiming;Sun, Chong;Bian, Huan;Xu, Weimin;Zhu, Yongzhi;Li, Pengpeng
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.1
    • /
    • pp.94-99
    • /
    • 2017
  • Objective: The aim of this study was to investigate the expression of heat shock protein (HSP) 90, 70, and 60 in chicken muscles and their possible relationship with quality traits of meat. Methods: The breast muscles from one hundred broiler chickens were analyzed for drip loss and other quality parameters, and the levels of heat shock protein (HSP) 90, 70, and 60 were determined by immunoblots. Results: Based on the data, chicken breast muscles were segregated into low (drip loss${\leq}5%$), intermediate (5%${\geq}9.5$) drip loss groups. The expression of HSP90 and HSP60 were significantly lower in the high drip loss group compared to that in the low and intermediate drip loss group (p<0.05), while HSP70 was equivalent in abundance in all groups (p>0.05). Conclusion: Results of this study suggests that higher levels of HSP90 and HSP60 may be advantageous for maintenance of cell function and reduction of water loss, and they could act as potential indicator for better water holding capacity of meat.

A Study on the Heat Loss Reduction of a Refrigerator by Thermal Conductivity Change and Partial Removal of Rubber Magnet (냉장고 가스켓 주위 고무자석 재질 및 형상 변경에 따른 열손실 개선 연구)

  • Ha, Ji Soo;Ahn, Won Sul
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.240-246
    • /
    • 2014
  • The present study has been carried out to reduce the heat loss from a refrigerator by changing thermal conductivity and partial removal of rubber magnet near refirgerator gasket. To perform this purpose, two dimensional heat transfer analysis for the horizontal cross sectional plane of a refrigerator has been accomplished. From the present study, it could be seen that the heat loss could be reduced nearly 7% by changing thermal conductivity of rubber magnet from 10W/mK to 1W/mK. The heat loss reduction, 17%, could be achieved by removal of rubber magnet near hotline and the effect on the heat loss reduction by partial removal of rubber magnet might be helpful for the refrigerator power consumption.

Trapezoidal Fin Analysis by the 3-D Analytical Method (3차원 해석적 방법에 의한 사다리꼴 휜 해석)

  • 이성주;강형석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.388-397
    • /
    • 2000
  • Comparison of the heat conduction into a trapezoidal fin and the heat loss from the fin by convection is made in this study Also, the ratio of heat loss from each surface to the total heat loss and the temperature distribution are analyzed using a 3-D analytical method. A trapezoidal fin whose tip height is half the root height is chosen as the model. The results show that the heat transfer rates from the tip and from both sides are comparable with each other as the non-dimensional width and length vary while the heat transfer rate from the bottom and top is dominant.

  • PDF