• 제목/요약/키워드: Heat Insulating Materials

검색결과 113건 처리시간 0.026초

유동대전(流動帶電)에 미치는 변압기(變壓器) 재질(材質)의 영향(影響) (Effect of Materials on Streaming Electrification in Transformer)

  • 권동진;강창구;곽희로;김재철;이덕철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.170-172
    • /
    • 1990
  • In a large power transformer, an insulating oil is forced to circulate for cooling the heat generated by the losses within the windings and core. When oil flows and rubs against various materials, including insulating paper and steel, electrostatic charges are separated at the interface of the oil and the solid material. This paper considers the polarity and the streaming electrification of the various materials which are used in transformer. As a result of this study, it is confirmed that the leakage current on the solid material, such as paper, is charged negative. On the other hand, the solid material, such as steel, is positively charged.

  • PDF

망목 구조 변화에 따른 에폭시 수지의 유전 특성에 관한 연구 (A Study on the Dielectric Characteristics in Epoxy Resins due to Variation of Network Structures)

  • 김재환;손인환;심종탁;김경환;김명호;최병옥
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권7호
    • /
    • pp.651-658
    • /
    • 1997
  • In this paper, effect of interpenetrating polymer network(IPN) introduction on the dielectric properties, heat proof properties, internal structure and defects of the Epoxy/SiO$_2$composite materials, were investigated. we reported a relation between network structures and electrical properties, especially dielectric characteristics with variation of network structures for epoxy composite materials. According to experimental results, the specimens which have single network structures have lower dielectric constant than interpenetrating polymer network(IPN) specimens, but have relatively larger dependency to variation of temperature and frequency. It was confirmed that change of structures is attained by introducing of IPN to insulating materials. Therefore it is counted that introduction of multiple structure including IPN is necessary to improve heat proof and electrical properties.

  • PDF

EFFECT OF HEAT CURING METHODS ON THE TEMPERATURE HISTORY AND STRENGTH DEVELOPMENT OF SLAB CONCRETE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

  • Lee, Gun-Che;Han, Min-Cheol;Baek, Dae-Hyun;Koh, Kyung-Taek
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.523-534
    • /
    • 2012
  • The objective of this study was to experimentally investigate the effect of heat curing methods on the temperature history and strength development of slab concrete exposed to $-10^{\circ}C$. The goal was to determine proper heat curing methods for the protection of nuclear power plant structures against early-age frost damage under adverse (cold) conditions. Two types of methods were studied: heat insulation alone and in combination with a heating cable. For heat curing with heat insulation alone, either sawdust or a double layer bubble sheet (2-BS) was applied. For curing with a combination of heat insulation and a heating cable, an embedded heating cable was used with either a sawdust cover, a 2-BS cover, or a quadruple layer bubble sheet (4-BS) cover. Seven different slab specimens with dimensions of $1200{\times}600{\times}200$ mm and a design strength of 27 MPa were fabricated and cured at $-10^{\circ}C$ for 7 d. The application of sawdust and 2-BS allowed the concrete temperature to fall below $0^{\circ}C$ within 40 h after exposure to $-10^{\circ}C$, and then, the temperature dropped to $-10^{\circ}C$ and remained there for 7 d owing to insufficient thermal resistance. However, the combination of a heating cable plus sawdust or 2-BS maintained the concrete temperature around $5^{\circ}C$ for 7 d. Moreover, the combination of the heating cable and 4-BS maintained the concrete temperature around $10^{\circ}C$ for 7 d. This was due to the continuous heat supply from the heating cable and the prevention of heat loss by the 4-BS. For maturity development, which is an index of early-age frost damage, the application of heat insulation materials alone did not allow the concrete to meet the minimum maturity required to protect against early-age frost damage after 7 d, owing to poor thermal resistance. However, the combination of the heating cable and the heat insulating materials allowed the concrete to attain the minimum maturity level after just 3 d. In the case of strength development, the heat insulation materials alone were insufficient to achieve the minimum 7-d strength required to prevent early-age frost damage. However, the combination of a heating cable and heat insulating materials met both the minimum 7-d strength and the 28-d design strength owing to the heat supply and thermal resistance. Therefore, it is believed that by combining a heating cable and 4-BS, concrete exposed to $-10^{\circ}C$ can be effectively protected from early-age frost damage and can attain the required 28-d compressive strength.

칼슘실리케이트 무기 단열소재의 양생기간에 따른 물리 특성 (Physical Properties of Calcium Silicate Inorganic Insulation Depending on Curing Time)

  • 박재완;추용식;정재현
    • 한국건축시공학회지
    • /
    • 제16권6호
    • /
    • pp.529-534
    • /
    • 2016
  • 칼슘실리케이트계 무기단열소재는 주원료로 시멘트를 90%를 사용하는 다공성 무기단열소재이다. 기존 무기단열소재와 달리 고온의 수화반응 처리가 없기 때문에 가격이 저렴하며, 불연소재의 원료를 사용하여 화제의 위험성도 적다. 칼슘실리케이트 단열소재는 $0.13g/cm^3$의 밀도와 0.050W/mK이하의 우수한 열전도도를 갖는 단열소재이다. 칼슘실리케이트 단열소재는 경량화 될수록 내부 기포를 다량 함유해야 하며 기포를 다량 함유함에 따라 단열성 또한 우수해진다. 본 연구에서는 다량의 기포를 함유하며 일정강도발현을 목표로, 칼슘실리케이트계 무기단열소재의 주성분인 시멘트가 수화반응에 따라 초기 및 장기강도발현하는 특성을 이용하여 칼슘실리케이트계 무기단열소재에 적용하여 물리적 특성을 알아보고자 하였다.

폐발포폴리스티렌 단열재를 순환골재로 사용한 경량 단열 모르타르의 강도특성 (Strength Characteristics of Light-weight Insulating Mortar Using Wasted Foam Polystyrene heat Insulating Materials as Recycling Aggregate)

  • 강혜주;진은미;강석표
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.221-222
    • /
    • 2016
  • The replacement ratio of waste EPS was varied, and its effect on compressive strength and absorption capacity was investigated. According to the experimental results, The 28th day compressive strengths for the W/C 50% specimens were 17.5~21.2MPa, which was relatively low compared to the 13.6~22.2MPa of the W/C 70%.

  • PDF

Thermal Protection Shield Concept for Diamond Impregnated Tools

  • Tillmann, W.;Gathen, M.;Kronholz, C.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.875-876
    • /
    • 2006
  • For dry machining of mineral materials the Institute of Materials Engineering pursues a novel thermal protection shield concept for diamond tools, in which thermal insulating materials in diamond composite structures act as heat shield, which protects diamonds in deeper layers against high temperature and graphitisation. Before the effectiveness of this concept could be investigated suitable composites have to be manufactured. In this paper the powder metallurgical production processes of diamond-alumina-cobalt-composites with varying alumina and cobalt particle sizes, their microstructures and porosities are described. It could be observed that the distribution of small-sized alumina particles ($<70{\mu}m$) in the cobalt matrix is uniform and the porosity of the composite decrease.

  • PDF

Utilization of Some Industrial Wastes for Producing of Polymeric Composite Materials

  • Hojieva, Alohida;Rustamov, Abduvali;Ahmedov, Akmal
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.95-98
    • /
    • 2003
  • Polymeric composite materials on the basis of some industrial wastes are obtained. Some physical parameters of experimental samples are determined. The analysis of exploitative properties of these polymer composite materials allows recommending them as a heat-insulating material in constructions.

  • PDF

전기화학 공정을 이용한 질화규소 기판 상의 금속 전극 형성에 관한 연구 (Formation of Metal Electrode on Si3N4 Substrate by Electrochemical Technique)

  • 신성철;김지원;권세훈;임재홍
    • 한국표면공학회지
    • /
    • 제49권6호
    • /
    • pp.530-538
    • /
    • 2016
  • There is a close relationship between the performance and the heat generation of the electronic device. Heat generation causes a significant degradation of the durability and/or efficiency of the device. It is necessary to have an effective method to release the generated heat. Based on demands of the printed circuit board (PCB) manufacturing, it is necessary to develop a robust and reliable plating technique for substrates with high thermal conductivity, such as alumina ($Al_2O_3$), aluminium nitride (AlN), and silicon nitride ($Si_3N_4$). In this study, the plating of metal layers on an insulating silicon nitride ($Si_3N_4$) ceramic substrate was developed. We formed a Pd-$TiO_2$ adhesion layer and used APTES(3-Aminopropyltriethoxysilane) to form OH groups on the surface and adhere the metal layer on the insulating $Si_3N_4$ substrate. We used an electroless Ni plating without sensitization/activation process, as Pd particles were nucleated on the $TiO_2$ layer. The electrical resistivity of Ni and Cu layers is $7.27{\times}10^{-5}$ and $1.32{\times}10^{-6}ohm-cm$ by 4 point prober, respectively. The adhesion strength is 2.506 N by scratch test.

전계-열계 유한요소해석을 이용한 저압 배선선로의 과부하 및 단락사고 발생시 전선의 온도해석에 관한 연구 (A Study on the Temperature Analysis for Cable in Overload and Short of Low Voltage Wiring using Electro-Thermal FEA)

  • 오홍석
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.91-96
    • /
    • 2004
  • Overloading of electrical equipment results in excessive currents. As the heat developed in the cables is proportional to square of the current, they get overheated. The insulation on cables is generally made of materials which are damaged easily by excessive temperature. They may therefore lose their insulating properties and lead to short circuits. Since many insulating materials are combustible, they may even catch fire if the temperature rises to their ignition temperature. In this paper, we have simulated the thermal analysis for cable according to the value of current in a overload and a short with the cable of the L's company product(600 V, VV : Four Core) using the electro-thermal finite element method(Flux2D).

  • PDF

가교방식에 따른 EPDM 절연재료의 열화특성 (Aging Characteristics of EPDM based Insulating Materials Depending on Curing Systems)

  • 이철호;전영준;김상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1697-1699
    • /
    • 1996
  • EPDM compound can be cured with either the sulfur and peroxide based systems. In this study, heat resistance and weatherability of EPDM compounds depending on curing systems were investigated. The test results showed that the peroxide-cured EPDM was more resistant to heat ageing and UV photo-degradation than the sulfur-cured EPDM and it is due to C-C bond is more stable than C-S, S-S bond.

  • PDF