• 제목/요약/키워드: Heat Indicator

검색결과 114건 처리시간 0.025초

국산 조제분유의 열처리 등급에 관한 기초 연구 (The Fundamental Studies of Heat Treatment Class in Domestic Infant Formula)

  • 박영희
    • 한국식품영양과학회지
    • /
    • 제27권3호
    • /
    • pp.495-500
    • /
    • 1998
  • To compare the extent of heat treatment in domestic infant formula, pH,titratable acidity, undenatured whey protein contents, HMF contents and protein-reducing substances of three commercial products (A, B, C) were measured. The pH of B products was lowest and the titratable acidity of B product was highest. The contents of undenatured whey protein per 100ml serum were 0∼30mg(A products), 90∼130mg(B products)and 80∼90mg(C products), respectively. Distinct differences of undenatured whey protein contents according to the manufacturer and infat's stage in age could be observed. The HMF contents of tested products showed 10.9∼21.5umol/L and B-2 product(B products for the second stage of 5∼9 month) was the highest among tested products. The protein-reducing substances showed 4.46∼9.50mg K4Fe(CN)6/100ml serum nd B-2 product was the highest among tested products.

  • PDF

Extension of the adaptive boundary element scheme for the problem with mixed boundary conditions

  • Kamiya, N.;Aikawa, Y.;Kawaguchi, K.
    • Structural Engineering and Mechanics
    • /
    • 제4권2호
    • /
    • pp.191-202
    • /
    • 1996
  • This paper presents a construction of adaptive boundary element for the problem with mixed boundary conditions such as heat transfer between heated body surface and surrounding medium. The scheme is based on the sample point error analysis and on the extended error indicator, proposed earlier by the authors for the potential and elastostatic problems, and extended successfully to multidomain and thermoelastic analyses. Since the field variable is connected with its derivative on the boundary, their errors are also interconnected by the specified condition. The extended error indicator on each boundary element is modified to meet with the situation. Two numerical examples are shown to indicate the differences due to the prescribed boundary conditions.

주방위생에서 항균수세미의 효과 (Inhibition Effect of Germ-resistant Sponge on Microbial Growth in Kitchen Hygiene)

  • 이용욱;나승식;조성범;정지연;박성기
    • 한국환경보건학회지
    • /
    • 제22권4호
    • /
    • pp.109-121
    • /
    • 1996
  • It was intended to investigate the effect of the microbiological kitchen hygiene such as dishclothes and scrubbers. The 8indicator organisms (standard plate counts, coliform, heterotroph, enterococcus, staphylococcus, heat-stable bacteria, psychrotroph, Pseudomonas aeruginosa) were detected highly in dishwaters, dishcloth and scrubber. Coliform and Staphylococcus aureus were appeared on dishcloth dominantly than the scrubber, and the scrubbers were intruded by hetrotrophs and psychrotrophs numerously than dishclothes. The germ-resistant sponge inhibited the growth of the most of test strain, and appeared the about 100% reduction rate after 24 hr, but did not affect Pseudomonas aeruginosa and P. fragi so typically after 24 hr. The anti-microorganism durability of germ-resistant sponge, treated with food soil, was maintained by 10 days, the early stage strain density was founded in 20 days, and the strains grew after 30 days.

  • PDF

중풍환자의 화열변증 진단지표에 관한 연구 (Study on the Diagnostic Indicators of Fire-heat Pattern Identification in Stroke Patients)

  • 이정섭;고미미;강병갑;김정철;김보영;이인;김윤식;최선미;방옥선
    • 동의생리병리학회지
    • /
    • 제23권2호
    • /
    • pp.499-504
    • /
    • 2009
  • The purpose of this study was to evaluate the diagnostic indicators which are used for the identification of fire-heat pattern in stroke patients. For evaluation of diagnostic indicator, we analyzed the indicators which are composed of symptoms and signs collected from stroke patients based on the clinical records using case report form (CRF). Patients had a first-ever stroke within 1 month after the onset of stroke. Pattern identification was performed and decided by two independent physicians. Two patient groups that consist of fire-heat pattern and the other patterns were compared to isolate important indicators affecting the fire-heat pattern identification of stroke patients. The 8 indicators among 16 fire-heat pattern indicators were significantly more frequent compared with non fire-heat pattern group. Logistic regression analysis revealed that 5 indicators among fire-heat indicators were significantly sensitive indicators being capable of identification of fire-heat pattern. But two of them was from the indicators of dampness-phlegm pattern and yin deficiency pattern. Therefore, further studies are required for the development of Korean standard indicators of Fire-heat pattern identification.

급성기 뇌경색 환자에 있어 변증형별 유의한 임상지표의 분석 (Analysis of Clinical Indicators related to Pattern-Identification in Acute Cerebral Infarction Patient)

  • 이은찬;현상호;곽승혁;우수경;박주영;정우상;문상관;조기호;박성욱;고창남
    • 대한중풍순환신경학회지
    • /
    • 제13권1호
    • /
    • pp.33-42
    • /
    • 2012
  • Object : The aim of this study was to assess the clinical indicators related to Pattern-Identification(PI) in acute cerebral infarction patients. Methods : We studied hospitalized patients within 30days after ictus, who admitted at Korean Medicine Center of Kyung-Hee University from January 2010 to October 2012.(n=290) Two Traditional Korean Medicine(TKM) physicians evaluated the patients independently and diagnosed PI. Inter-rater reliability was measured using simple percentage agreement and the Cohen's kappa(κ) coefficient. To assess the clinical indicators closely related to each PI, we analysed average score of each indicator in each group. Results : Simple percentage agreement of PI between raters was 64.83% and Cohen's kappa(κ) coefficient was 0.526(95% CI: 0.451-0.600). Inter-rater reliability level was fair to good. We analysed the clinical indicators in each group. Significant indicators for Fire-Heat Pattern(FHP) were reddened complexion and strong pulse power, and meaningful indicators for FHP were halitosis and thick tongue fur. Significant indicator for Dampness-Phlegm Pattern(DPP) was overweight and there was no meaningful indicator. Significant indicator for Yin-Deficiency Pattern(YDP) was dry tongue fur and meaningful indicator for YDP was thirst. There was no significant indicator for Qi-Deficiency Pattern(QDP) and pale complexion and faint low voice were meaningful indicators for QDP. Conclusions : This study reveals the significant and meaningful clinical indicators related to each Pattern-Identification in acute cerebral infarction patients. It will contribute to standardization of Korean Medical Diagnosis and Treatment in acute cerebral infarction patients.

  • PDF

냉자극에 대한 맥율 변화 예비 연구 (A Feasibility Study of Pulse Rate Per Respiration as an Indicator for the Reaction to Cold Stress)

  • 배장한;전영주;김현호;김재욱
    • 동의생리병리학회지
    • /
    • 제28권6호
    • /
    • pp.668-673
    • /
    • 2014
  • Cold and Heat pattern identification(CHPI) in traditional East Asian medicine(TEAM) is one of the major indicator to distinguish characteristics of disease and to determine treatment method. Basic parameters to determine CHPI include the pulse rate, respiration rate, and pulse power. Studies to associate physiological responses of human body by cold stress(CS) with CHPI in TEAM were rarely done so far. This study aims to explore the effects of cold stress on pulse signal via a feasibility study for three subjects and investigate some indices which can reflect autonomic nerve reaction(ANR). We measured radial pulse signals and respiration signal of the investigated subjects before the CS, during the CS which continues for 5 minutes, and immediately after the CS, respectively. Finally, we analyzed the pulse rate (P), respiration rate (R), pulse power, pulse depth, and pulse rate per respiration (P/R ratio). As a result, the P/R ratio showed a consistently decreasing tendency through the CS stimulation process, while other parameters behaved more complex and in subject-specific ways. It implies that, among candidate parameters, the P/R ratio is a simple but the most probable parameter that can be used as the ANR indicator. This result is also consistent with the theory in TEAM scripts, in which the P/R ratio is predicted to be a direct indicator for the CHPI. This pilot study shows that P/R ratio can be more appropriately associated with the ANR than heart rate or respiration rate alone. Extensive studies will be necessary to verify or confirm the P/R ratio as an appropriate and well defined parameter for ANR.

수부 냉증 정도와 Heart Rate Variability(HRV)의 상관성 연구 (A Study on the Correlation of Heart Rate Variability and Coldness of Hands)

  • 남은영;유수정;김형준
    • 대한한방부인과학회지
    • /
    • 제28권4호
    • /
    • pp.46-56
    • /
    • 2015
  • Objectives : Cold hypersensitivity has been regarded to be associated with Autonomic Nervous System (ANS). This study aims to investigate the indicator of cold hypersensitivity of hands and evaluate the correlation between indicator of coldness of hands and Heart Rate Variability (HRV). Methods : We studied 55 patients with cold hypersensitivity of hands who visited in SeMyung University Hospital from 17 August 2015 to 21 August 2015. Thermometer and VAS scale were used for the diagnosis of cold hypersensitivity. After careful examination to rule out other disease which may affect thermometer and HRV data, patients were taken thermometer, those with thermal difference between upper arm (L4) and palm(P8), also asked to answer a VAS scale of cold hypersensitivity of hands, VAS more than 4 were enrolled for evaluation. Results : There was significant correlation between L4-P8 temperature difference and VAS score of cold hypersensitivity. In HRV data, normalized high frequency (HF normal) was significantly correlated with L4-P8 temperature difference, which was objective indicator of cold hypersensitivity of hands. Conclusions : L4-P8 temperature difference using thermometer is objective indicator of cold hypersensitivity, based on VAS scale. Cold hypersensitivity is highly related with ANS, regulating body heat and temperature. HRV is considered to be widely used in cold hypersensitivity in hands for evaluation of ANS.

Challenges in Selecting an Appropriate Heat Stress Index to Protect Workers in Hot and Humid Underground Mines

  • Roghanchi, Pedram;Kocsis, Karoly C.
    • Safety and Health at Work
    • /
    • 제9권1호
    • /
    • pp.10-16
    • /
    • 2018
  • Background: A detailed evaluation of the underground mine climate requires extensive measurements to be performed coupled to climatic modeling work. This can be labor-intensive and time-consuming, and consequently impractical for daily work comfort assessments. Therefore, a simple indicator like a heat stress index is needed to enable a quick, valid, and acceptable evaluation of underground climatic conditions on a regular basis. This can be explained by the unending quest to develop a "universal index," which has led to the proliferation of many proposed heat stress indices. Methods: The aim of this research study is to discuss the challenges in identifying and selecting an appropriate heat stress index for thermal planning and management purposes in underground mines. A method is proposed coupled to a defined strategy for selecting and recommending heat stress indices to be used in underground metal mines in the United States and worldwide based on a thermal comfort model. Results: The performance of current heat stress indices used in underground mines varies based on the climatic conditions and the level of activities. Therefore, carefully selecting or establishing an appropriate heat stress index is of paramount importance to ensure the safety, health, and increasing productivity of the underground workers. Conclusion: This method presents an important tool to assess and select the most appropriate index for certain climatic conditions to protect the underground workers from heat-related illnesses. Although complex, the method presents results that are easy to interpret and understand than any of the currently available evaluation methods.

종이 물성이 전열교환 엘리먼트 성능에 미치는 영향 (Effect of Paper Properties on the Performance of a Enthalpy Exchanger)

  • 김내현;조진표;송길섭;김동훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.414-418
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Three enthalpy exchanger samples having different properties were made, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were defined, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that water vapor transmission rate alone was not a proper indicator for the efficiency of latent heat transfer. Air permeability should also be considered for adequate evaluation of the latent heat transfer. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

  • PDF

대사열의 발생을 이용한 활성슬러지의 활성 측정

  • 박순응;허원
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.398-401
    • /
    • 2000
  • A device to measure the temperature difference between the supernatant and the sediment blanket in the course of SV30 measurement in processing of activated sludge process. The temperature elevation in the sludge sediment represent the metabolic heat production by the microorganisms and can be an indicator for the capability of waste treatment. The utilities of the device for the analysis of activated sludge process were demonstrated in this report.

  • PDF