• Title/Summary/Keyword: Heat Flow Rate

Search Result 1,936, Processing Time 0.029 seconds

Analytical Study on the Heat Transfer Characteristics of a Spirally Coiled Circular Fin-Tube Evaporator Operated Under Non-Frosting Conditions (무착상 조건에서 나선형 원형핀-튜브 증발기의 열전달 성능에 관한 해석적 연구)

  • Lee, Moo-Yeon;Kang, Tae-Hyung;Kim, Yong-Chan;Park, Jae-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.105-112
    • /
    • 2011
  • The objective of this study is to predict the heat-transfer performance of a spirally coiled circular fin-tube evaporator in which either R134a or R600a was used; this heat-transfer performance was predicted by varying the mass flow rate, inlet air temperature, air flow rate, and tube thickness. Mean deviation for the analytical model from the measured data was ${\pm}8.3%$. Simulation results revealed that at a given mass flow rate, the heat-transfer rate of the evaporator using R600a was higher than that usingR134a because the enthalpy of the former is higher than that of the latter at the given conditions. The heat-transfer rate of both refrigerants increased with an increase in the air flow rate and inlet air temperature but decreased with an increase in the tube thickness.

Study on the Single Bubble Growth During Nucleate Boiling at Saturated Pool (포화상태 풀비등시 단일기포의 성장에 관한 연구)

  • Kim Jeongbae;Lee Han Choon;Oh Byung Do;Kim Moo Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.169-179
    • /
    • 2005
  • Nucleate boiling experiments on heating surface of constant wall temperature were performed using R113 for almost saturated pool boiling conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain a constant wall temperature condition of heating surface and to measure the heat flow rate with high temporal and spatial resolutions. Bubble images during the bubble growth were taken as 5000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble growth behavior was analyzed using the new dimensionless parameters for each growth regions to permit comparisons with previous experimental results at the same scale. We found that the new dimensionless parameters can describe the whole growth region as initial and later (thermal) respectively. The comparisons showed good agreement in the initial and thermal growth regions. In the initial growth region including surface tension controlled, transition and inertia controlled regions as divided by Robinson and Judd, the bubble growth rate showed that the bubble radius was proportional to $t^{2/3}$ regardless of working fluids and heating conditions. And in the thermal growth region as also called asymptotic region, the bubble showed a growth rate that was proportional to $t^{1/5}$, also. Those growth rates were slower than the growth rates proposed in previous analytical analyses. The required heat flow rate for the volume change of the observed bubble was estimated to be larger than the heat flow rate measured at the wall. Heat, which is different from the instantaneous heat supplied through the heating wall, can be estimated as being transferred through the interface between bubble and liquid even with saturated pool condition. This phenomenon under a saturated pool condition needs to be analyzed and the data from this study can supply the good experimental data with the precise boundary condition (constant wall temperature).

Optimization of a straight fin heat sink in 3D LCos projector considering bypass flow and a flow barrier

  • Kim, Jin-Wook;Kim, Sang-Hoon;Lee, Seung-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1265-1268
    • /
    • 2009
  • In this paper, the effect of a flow barrier and bypass on the cooling performance for a straight fin heat sink is presented. Both side directions and upward direction of bypass are controlled using various ducts which have different width and heights. In addition, a flow barrier is used to control flow toward heat sink. Through experiments, the distance from leading edge of a heat sink to a flow barrier is varied for various bypasses under fixed volume flow rate condition. This study shows possibility to improve cooling performance when bypass and a flow barrier exist.

  • PDF

Numerical Analysis of Flow- and Heat Transfer of a Spinning Blunt Body at Mach 5 (마하수 5에서 회전하는 blunt body의 유동 및 열전달에 관한 수치해석)

  • Lee Myung Sup;Lee Chang Ho;Park Seung O
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.172-177
    • /
    • 2000
  • In this numerical work, three dimensional supersonic laminar flow and heat transfer of a blunt body(sphere-cone) at Mach 5 is simulated. The effects of angle of attack and the spin rate on the now and heat transfer are analysed. To solve the three dimensional compressible Wavier-Stokes equation, a finite volume method with the modified LDFSS scheme is employed for spatial discretization, and a point SGS implicit method is used for time integration. It is found that the heat transfer rate increases at the windward side and decreases at the leeward side with the angle of attack. The heat transfer rate at all surfaces slightly increases with the spin rate.

  • PDF

A Study on the Heat Transfer Characteristics of Slurry Ice Generator using Scraper (스크레퍼형 슬러리아이스 제빙기의 열전달 특성 연구)

  • Kim, Joung-Ha;Yun, Jae-Ho;Kim, Min-Jun;Kim, Kyu-Jin;Cho, Hyoug-Seok;An, Seong-Kuk
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.144-149
    • /
    • 2006
  • In this study ice making characteristics are experimentally investigated for the ice slurry generating system which is pneumatically operated. The experimentations are conducted under the various test conditions such as chilled water inlet temperature, aqueous solution concentration, flow rate of cooling water, scraper pitch and frequency of cylinder stroke. For the above experimental conditions, ice making characteristics of the slurry ice generating system are evaluated in terms of the overall heat transfer coefficient, heat transfer rate and the amount of slurry ice generation. And the experimental results show that the heat transfer rate of the system increases as the flow rate of cooling water solution increases and the concentration of ethylene glycol and inlet temperature of chilled water decreases.

  • PDF

Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region (희박 분무영역에서의 분무냉각 막 비등 열전달에 관한 연구)

  • Kim Yeung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.279-286
    • /
    • 2005
  • This study presents experimental results on the heat transfer coefficients in the film boiling region of spray cooling for actual metallurgical process. In this study, the heat flux distributions of a two dimensional dilute spray impinging on a hot plate were experimentally investigated. A stainless steel block was cooled down from intial temperature of about $800^{\circ}C$ by twin fluid (air-water) flat spray. It was found from the experimental results that the heat transfer area was classified into the stagnation region and wall-flow region. In the stagnation region, the experimental data of local heat transfer coefficient was closely correlated with the local droplet-flow-rate supplied from the spray nozzle directly. Thus, the local heat transfer coefficients are in good agreement with the predicted values from the correlations proposed by our previous study. In wall-flow region, however, remarkable differences are observed between experimental data and predicted values because the number of rebound droplets increase with increasing the distance from the stagnation point.

A Study on the Conjugate Heat Transfer from Horizontal Plate with Protruding Heat Source (열원이 부착된 수평 평판에서 복합 열전달에 관한 연구)

  • 김병철;주동인
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.512-518
    • /
    • 2002
  • The real chip and similarity model were used to investigate the thermal behavior and velocity distribution of air from the heat source with the location and the amount of heat experimentally and numerically, and compared. The heat generated in the block is not cooled by convection and show the high temperature by the stagnation of heat flow. After maintaining the high temperature of block by the natural convection, the sudden drop of temperature with the air flow was shown in the channel but the decreasing rate was small with the time. The inward block was effected by infinitesimal air flow generated between block and channel and outward block was effected by the entry condition.

NUMERICAL ANALYSIS ON THE HEAT TRANSFER AND FLOW IN THE SHELL AND TUBE HEAT EXCHANGER (Shell & Tube 열교환기 Shell 측 열전달 및 유동에 대한 수치해석)

  • Lee, Sang-Hyuk;Lee, Myung-Sung;Hur, Nahm-Keon
    • Journal of computational fluids engineering
    • /
    • v.12 no.3
    • /
    • pp.13-19
    • /
    • 2007
  • A numerical simulation on the heat transfer and flow field was carried out to improve the performance of the shell and tube heat exchanger. The steady incompressible 3-D Navier-Stokes solution is obtained with the actual operational condition and geometry of the heat exchanger. Based on this study, it is noted that the present geometry of the heat exchanger causes poor heat transfer since the air inside shell does not flow through the tube bundle, but around it. The enhancement of the heat transfer can be achieved by the variation of the design factor like the sealing strip located on the top/bottom and middle of the baffle, but it causes the increasement of the pressure drop. In this paper, the effects of the location and size of the sealing strips and flow rate through the heat exchanger on the heat transfer and pressure drop are studied.

A Study on the Performance Analysis in the Plate and Shell Heat Exchanger (판각형 열교환기 성능해석에 관한 연구)

  • Seo, M.K.;Park, J.H.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • Heat exchangers are called with important devices which have been widely used in industrial fields. Therefore, the design method for a heat exchanger is an important study in the aspect of energy saving. In this study, performance analyses for two types of plate and shell heat exchangers having a corrugated trapezoid shape of a chevron angle with $45^{\circ}$, were executed and compared with experiments. For this study, the operation liquids were adopted with non-phase changing water. In the analysis, ${\epsilon}-NTU$ method was used for a plate and shell heat exchanger and a program was constructed. Independent variables for a plate and shell heat exchanger are flow rate and inlet temperature. Compared with experimental data, the accuracy of the developed are ${\pm}2.5%\;and\;{\pm}5%$ at the type A and type B in the heat transfer rate, respectively. In the pressure drop, the accuracy of the proposed program for a plate and shell heat exchanger is within ${\pm}3%$ and 5% error bounds for the type A and type B, respectively.

  • PDF

Analysis of cooling phenomenon of water with the supercooled (과냉각을 동반한 순수물의 냉각현상 해석)

  • Chu, Mi-Seon;Yun, Jeong-In;Kim, Jae-Dol;Kamata, Yoshinobu;Kato, Toyofumi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.862-872
    • /
    • 1997
  • Ice formation in a horizontal circular cylinder has been studied numerically. From the numerical analysis results, it was found that there were three types of freezing pattern and that freezing phenomenon was affected largely by density inversion and cooling rate. The type of freezing pattern largely depends on the secondary flow which is generated by density inversion. When supercooling energy is released before the development of the secondary flow, the annular ice layer grows. If the energy is released when the secondary flow is considerably developed and the supercooled region is removed to the upper half part of the cylinder, an asymmetric ice layer grows. And if the energy is released after perfect development of the secondary flow, instantaneous dendritic ice formation over the full region occurs. Furthermore, this secondary flow was found to have an effect on heat transfer characteristics. The heat transfer rate becomes small at the instant when the secondary flow is generated, but becomes large with the development of the flow. It's concluded that for the facilitation of heat transfer it is desirable to keep water in liquid phase until the secondary flow is perfectly developed. This study gave an instruction of performance improvement of capsule type ice storage tank.