• Title/Summary/Keyword: Heat Check

Search Result 197, Processing Time 0.023 seconds

Development of a Thermal Design Software for the Heat Recovery Steam Generator of Combined Cogeneration Systems (열병합 복합발전시스템용 폐열회수 보일러 열설계 소프트웨어 개발 연구)

  • Kim, T.K.;Oh, S.D.;Kwon, Y.H.;Seo, S.H.;Kim, B.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.726-731
    • /
    • 2001
  • A thermal design software is developed for the heat recovery steam generator(HRSG) of combined cogeneration systems. The heat transfer is calculated by using the element method to account for the varying thermal properties across the heat transfer elements. The circulation balance is computed for the evaporator to accurately estimate the steam generation rate and to check the proper circulation of the boiler water through the tubes. The software developed can be used to simulate HRSG systems with various combinations of auxiliary burner, wall superheater, superheater, reheater, evaporator, and economizer. Systems with several different combinations of the system components are successfully tested. And it is concluded that the developed software can be used for the design of heat recovery steam generators with various combinations of heat transfer components.

  • PDF

Effect of Divergence Ratio on Heat Transfer and Friction Factor in the Diverging Channel (확대 채널에서 확대율이 열전달과 마찰계수에 미치는 효과)

  • Oh, Se-Kyung;Lee, Myung-Sung;Jeong, Seong-Soo;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.64-70
    • /
    • 2013
  • The heat transfer and friction factor characteristics of turbulent flows in three stationary channels have been investigated experimentally to check out the effect of divergence ratio. These are a constant cross-sectional channel and two diverging channels with ratio of divergence(Dho/Dhi) of 1.16 and 1.49. The measurement was conducted within the range of Reynolds numbers from 15,000 to 89,000 and the dimension of uniform cross-sectional test section is $100mm{\times}100mm$ at the cross section and 1,000 mm in length. The measurements of heat transfer coefficients and friction factors in the uniform channels were conducted as a reference. Because of the streamwise flow deceleration, the heat transfer and friction factor characteristics in the diverging channel were quite different from those of the constant cross-sectional channel. The effective friction factors and convective heat transfer coefficients increased with increasing the ratio of divergence of the channel.

Development of an insulation performance measurement unit for full-scale LNG cargo containment system using heat flow meter method

  • Lee, Jin-sung;Kim, Kyung-su;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.4
    • /
    • pp.458-467
    • /
    • 2018
  • Efforts have been made in this paper to develop the measuring device for the insulation performance of full scale NO96 LNG CCS. The facility was designed to maintain environmental conditions which are similar to operation conditions of full scale LNG CCS. In the facility, the heat sink boundary was kept cryogenic temperature by cold chamber which contains liquefied nitrogen and heat source boundary was made by external case heated by natural convection. Heat Flow Meter method (HFM) was applied to this facility, hence Heat Flux Sensors (HFS) were attached to specimen. The equivalent thermal conductivity of full scale NO96 unit box was targeted to measure and PUF of same size was used for the calibration test. Additionally, the finite element analysis was carried out to check the performance of the developed test facility and experimental results were also compared with those predicted by the numerical method.

The Heat Exchangers Performance Experiment for a Field Application Ice Slurry Cooling System (현장 적용 아이스슬러리 시스템의 열교환기 성능 실험)

  • Lee, Sang-Hoon;Yoo, Ho-Seon;Lee, Yoon-Pyo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1002-1007
    • /
    • 2009
  • The research are performed to check the characteristics of the ice slurry transport system for the district cooling. The system are installed at the 1st floored building which is as large as the $1204\;m^2$ ($86\;m{\times}14\;m$). Three kinds of heat exchanger are selected, such as, plate, spiral and shell & tube type, to apply to the ice slurry systems. Experiment was done in the two cases. The first case, circulation water flow fixed at the design conditions for the state to change the flow of the supply of ice slurry. The second case, Ice slurry flow fixed at the design conditions for the state to change the flow of circulation water. Both side of Energy balance was calculated. The performance of plate heat exchanger is higher than others and it's enthalpy effectiveness is higher too.

  • PDF

A Research on Exterior Heat Syndrome Diarrhea of Taeumin(太陰人) (태음인(太陰人) 표열증(表熱證) 설사(泄瀉)에 대한 고찰)

  • Shin, Sang-won
    • Journal of Korean Medical classics
    • /
    • v.31 no.2
    • /
    • pp.155-172
    • /
    • 2018
  • Objectives : The first object is to reveal the mechanism of diarrhea based on exterior heat syndrome for Taeumin as explained in Donguisusebowon's Taeeumingansuyeoliyeolbyeonglon. The second objective is to review the treatment for Taeumin as explained in Leejema's Galgeunnabogjatang because the drug composition of Galgeunnabogjatang, the drug that treats this syndrome, is not written. Methods : As the first step, the paper will review the disease pathology for Taeumin written, and check the existence of disease path that can be viewed as exterior heat syndrome. As the second step, the paper will review the probability of exterior heat syndrome deriving from Taeumin disease path and morph into the exterior heat syndrome. Results : Using the first step to discover the direct correlation between exterior heat syndrome and the theory of disease for Taeumin led to a failure, but through the second step, the paper was able to confirm the probability that exterior heat syndrome could derive from Wiwansuhanpyohanbyeong's Wiwanhanjeung. Based on this, the paper was able to determine the Galgeunnabogjatang suitable for the treatment of exterior heat syndrome. Conclusions : Exterior heat syndrome is created when healthy qi is stimulated to quickly build up the pathogen of Taeumin exterior heat syndrome, but only exterior heat is generated and the cold remains. Its main symptoms are fever, excessive sweating, and difficult painful red-urination. Exterior heat syndrome diarrhea refers to the diarrhea which is generated from the Taeumin's disease pathology. The paper determined that Galgeunnabogjatang, which is listed in Donguisusebowon the seventh edition Boyubang.

Effects of Wavy Tapers on Heat Transfer in the Reciprocating Rectangular Channel (왕복운동을 하는 사각채널에서 파형테이퍼가 열전달에 미치는 효과)

  • 안수환;배성택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.600-608
    • /
    • 2003
  • This Paper describes a detailed experimental investigation of heat transfer in a reciprocating smooth rectangular duct having only the bottom wall heated with reference to the design of a piston for a marine propulsive diesel engine The Parametric test matrix involves Reynolds number and reciprocating radius, respectively, in the range of 1.280∼4.100, and 7∼15 cm with five different reciprocating frequency tested. namely. 1.7, 2.2, and 2.6 Hz. The effects of three different hemi-triangular wavy type tapers on the heat transfer in the reciprocating rectangular channel using the air as a working fluid were check out. The present work confirms that the Nusselt number in the channel with the triangular wavy type taper is lower than without the triangular wavy type taper.

Meteorological Data Integrity for Environmental Impact Assessment in Yongdam Catchment (용담댐시험유역 환경영향평가의 신뢰수준 향상을 위한 기상자료의 품질검정)

  • Lee, Khil-Ha
    • Journal of Environmental Science International
    • /
    • v.29 no.10
    • /
    • pp.981-988
    • /
    • 2020
  • This study presents meteorological data integrity to improve environmental quality assessment in Yongdam catchment. The study examines both extreme ranges of meteorological data measurements and data reliability which include maximum and minimum temperature, relative humidity, dew point temperature, radiation, heat flux. There were some outliers and missing data from the measurements. In addition, the latent heat flux and sensible heat flux data were not reasonable and evapotranspiration data did not match at some points. The accuracy and consistency of data stored in a database for the study were secured from the data integrity. Users need to take caution when using meteorological data from the Yongdam catchment in the preparation of water resources planning, environmental impact assessment, and natural hazards analysis.

Fracture Toughness Evaluation for Main Feed Water Valves of Korean Standard Nuclear Power Plant (한국표준원전 주급수 밸브의 파괴인성 평가)

  • Yoon, Ji-Hyun;Hong, Seokmin;Lee, Bong-Sang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 2015
  • The fracture toughness of 2.25Cr-1Mo cast steel (SA217-WC9) samples which were taken from the check valves of feed water piping of Korean Standard Nuclear Power Plant(KSNPP) was measured by Master Curve method. The measured $T_0$ reference temperature of SA217-WC9 steel was $-30^{\circ}C$. The obtained $T_0$ was compared to the derived value from Charpy impact test data following to SINTEP procedure. The heat-to-heat variation in fracture toughness of SA217-WC9 steel was observed. It was found that the low toughness of a heat of SA217-WC9 steel was attributed to the coarse MnS inclusion originated by high sulfur content as the results of microanalyses.

Effect of Bi2212 Tubes Depending on Mold-design and Cooling Conditions (몰드 디자인과 냉각조건이 Bi2212 초전도튜브에 미치는 영향)

  • Lee, N.I.;Jang, G.E.;Oh, I.S.;Park, K.B.
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.104-107
    • /
    • 2006
  • For the practical application on SCFCL(Superconducting fault current limiters), Bi-2212 tubes were fabricated by Centrifugal Forming Process(CFP). The tubes were annealed at 830, 840, $850^{\circ}C$, respectively for 80 hours in oxygen atmosphere. The tubes heat treated at $840^{\circ}C$ demonstrated better electric characteristics than the tubes heat treated at 830 and $850^{\circ}C$. The typical value measured at 77 K in the self field was around 556 A. In terms of cooling effect on superconducting properties, it was found the electrical properties were quite dependent on the mold design and shapes. In order to check uniformity along the tube, EFDLab fur heat and fluid analysis of NIKA was adopted. It was found out that the simulation data was quite well matched with experimental results.

  • PDF

Performance Evaluation of a Variable Frequency Heat Pump Air Conditioning System for Electric Bus

  • Peng, Qinghong;Du, Qungui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.1
    • /
    • pp.13-22
    • /
    • 2015
  • This study presents a simulation model of a heat pump air conditioning system with a variable capacity compressor and variable speeds fans for electric bus. An experimental sample has been developed in order to check results from the model. Effects on system performance of such working conditions as compressor speed, evaporator fans speeds and the condenser fans speeds have been simulated by means of developed model. The results show that the three speeds can be adjusted simultaneously according to actual working condition so that the AC system can operate under the optimum state which the control objects want to achieve. It would be a good and simple solution to extend the driving ranges of EVs because of the highest efficiency and the lowest energy consumption of AC system.