Heat and Mass Transfer Characteristics of LiCl Aqueous Solution for a Plate Heat Exchanger Type Dehumidifier (판형 열교환기식 제습기에서 LiCl 수용액의 열 및 물질전달 특성)

  • Jeon, Dong-Soon;Lee, Hae-Seung;Kim, Seon-Chang;Kim, Young-Lyoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • Experimental investigations were carried out to examine the heat and mass transfer characteristics of LiCl aqueous solution for a plate heat exchanger type dehumidifier. Cooling dehumidification was adopted vertical type heat exchanger. Also non woven fabric is attached surface of the heat exchanger for spreadability of LiCl aqueous solution. Mass flow-rate of LiCl aqueous solution and concentration were selected as experimental conditions. Also, In this study, the effects of relative humidity of process air and velocity were investigated experimentally. As a result of heat transfer coefficient and mass transfer coefficient of were increased film reynolds number increased. heat transfer coefficient and mass transfer coefficient of LiCl aqueous solution were 0.14~0.24 kW/$m2^{\circ}C$ and $1.3{\times}10-63{\sim}6.2{\times}10-6$ m/s respectively.

An Experimental Study on Absorber with Spiral Tube in Absorption Heat Pump (흡수열펌프에서 나선형 관이 설치된 흡수기의 실험적 연구)

  • Min, Byong-Hun
    • Applied Chemistry for Engineering
    • /
    • v.21 no.1
    • /
    • pp.71-75
    • /
    • 2010
  • The efficient performance of absorber is of great importance for the absorption heat pump cycle. The experimental study of absorber with spiral tube of tangential feeding of liquid phase has been investigated using methanol-glycerine as a working fluid. The effect of change in absorber operating conditions was analyzed to improve the performance. The increase in solution flow rate and cooling flow rate positively affects the absorber performance while an increse in the solution concentration negatively affects the absorber performance. The results showed that mass absorption flux was in the range of $0.2{\sim}0.6kgm^{-2}sec^{-1}$, the solution heat transfer coefficient between 1.6 and $4.2kwm^{-2}K^{-1}$, the absorber thermal load from 0.9 to 1.5kw and the mass transfer coefficient from 0.9 to 1.7 m/sec.

Analysis of LiBr-H$_{2}$O Film Absorption on a Horizontal Tube (수평원관상의 LiBr-H$_{2}$O 액막흡수현상 해석)

  • Park, Il-Seok;Choe, Do-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.2
    • /
    • pp.670-679
    • /
    • 1996
  • A numerical study for vapor absorption into LiBr-H$_{2}$O solution film flowing over horizontal circular tubes has been carried out. The momentum, energy and diffusion equations, which are parabolized by the boundary- layer approximation, are solved simultaneously for various mass-flow rates and inlet conditions. The results for the velocity, temperature and concentration fields, as well as the heat and mass flux at the free surface are presented. The effects of inlet conditions, i.e., flow rate, temperature and concentration, on the absorption process are also examined and discussed.

Properties of Acylated Mungbean Whole Globulin (Acyl화에 의한 녹두 Whole Globulin의 특성에 관한 연구)

  • Kim, Yong-Hwan;Song, Jong-Seon;Kim, Gwang-Su
    • The Korean Journal of Food And Nutrition
    • /
    • v.2 no.1
    • /
    • pp.18-26
    • /
    • 1989
  • The objective of this study was to improved the limited functional characteristics of mungbean whole globulin. The mungbean whole globulin was acylated with succinic and acetic anhydride, and the functional properties of acylated protein were investigated, The results obtained ware as follows. 1. The UV-absorption spectra of acylated whole globulins with that of the succinylated 74% whole globulin as large blue shift of the absorption maximum and minimum wavelength from 275 nm to 269 nm, respectively. 2. The mobility of acylated whole globulin were increased on PAGE pattern, and degree of mobility was particularly remarkable in case of succinylation, 3. The water absorption capacity of whole globulin was increased by acylation. The most increased rate of whole globulin was 174,02% from succinylated 74%. The oil absorption capacity of whole globulin was increased by acylation The most increased rate of whole globulin was 165.41% from acetylated 81.77%. 4. The bulk density of whole globulin was decreased by acylation. and the greater the extent of acylation, the smaller the bulk density. 5. The foaming capacity and stability of whole globulin was increased by acylation, and remarkably high in 74% succinylated whole globulin. In contrast, however, the foaming capacity and stability of native and acylated whole globulin were decreased by heat treatment.

  • PDF

The Study of The Collector Efficiency Curve (태양열 집열기 효율곡선에 대한 연구)

  • Shin, J.C.
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.198-202
    • /
    • 2014
  • In the solar heat collection system, we can determine how the collector will perform under specific conditions from the efficiency curve. By understanding the basic principles which govern the operation, designers can maximize the output from the collector. Absorptance, transmission and the total heat transfer coefficient were introduced to induce this efficiency curve. Designers who can make use of the implicit information on the curve in this report will generate systems which obtain the best return from their client's investment.

Mass transfer characteristics of benzene in nonpolar solution (비극성용매 내의 벤젠 물질전달특성)

  • 최성우;김혜진;박문기
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.605-610
    • /
    • 2002
  • The absorption of benzene in nonpolar solution was studied in a laboratory-scale of bubble column varying of gas flow rates and gas-to-liquid ratios. A bubble column had a 0.8∼l$\times$10$\^$-3/ m$^3$ total volume (height 1500 mm, diameter 50 mm). Solution analysis was performed by GC-FID and GC-MSD. The objectives of this research were to select the best absorption fluid and to evaluate the mass transfer characteristics under specific conditions of each absorption. The results of this research were follow as: First, the heat transfer fluid is more efficient than the other nonpolar solution in removing VOC. Second, The benzene removal efficiency improved according to an increasing rate of gas flow. Also, volumetric mass transfer rate of column can be enhanced by increasing gas flow rate. Finally, the relation of gas flow rates, liquid amount, and volumetric mass transfer coefficient was obtained as follows. K$\_$y/a: 0.5906(V$\_$g//L)$\^$0.7611/ The following correlation of mass transfer coefficient and efficiency was proposed. v= 0.06078 K$\_$y/a$\^$0.2444/.

Variations of the Polar Temperature in the Lower Stratosphere during 1955-2004

  • Choi, Wookap;Kim, Dongjoon
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2008
  • The lower-stratospheric polar temperature in winter and spring for both hemispheres is investigated based on the NCEP/NCAR 50-year reanalysis data with respect to the strength of the stratospheric eddy heat flux. Both the polar temperature and the eddy heat flux show significant variation on the decadal and year-to-year time scales except during the Southern Hemisphere winter. The year-to-year variation in the polar temperature is mainly determined by the eddy heat flux convergence. The eddy heat flux convergence is compared with the diabatic heating rate obtained from a two-dimensional model. Radiative heating caused by absorption of solar radiation is comparable to the heating caused by the eddy heat flux convergence in the Southern Hemisphere. The effect of ozone depletion on diabatic heating has been found to be secondary in the Northern Hemisphere, even in March 1997 when the record depletion of ozone took place.

The Evaluation of the thermal degradation and the degree of cure of glass/epoxy composite by ultrasonic technique (복합재료의 열화도 및 경화도에 따른 초음파 특성 연구)

  • 강길호;최원종;박상윤
    • Composites Research
    • /
    • v.16 no.6
    • /
    • pp.33-40
    • /
    • 2003
  • The initial thermal degradation of polymer matrix composite is not observed easily. At the beginning of thermal degradation of polymer matrix composites, phase transformation such as chain scission, oxidation occur, and then micro delamination is produced in matrix and interface between matrix and fiber before blistering. Initial heat damage deteriorate mechanical properties of composites. We presented the detection method of the initial heat damage of composites conveniently using ultrasonic technique. Absorption coefficient and material velocity was measured with thermal degradation and degree of cure. The more thermal degradation was progressed, the more absorption coefficient was increased. When the cure temperature is more high, the absorption coefficient of cured composite is increased and material velocity is decreased. We concluded that cure temperature is more high, the defects such as void is increased and molecular structure cured at high temperature has cross-linking structure which is more absorb the ultrasonic waves.

Variation in IR Absorption Characteristics of a Bolometer by Resistive Hole-array Patterns (저항성 홀배열이 적용된 볼로미터의 적외선 흡수 특성 변화)

  • Kim, Tae Hyun;Oh, Jaesub;Park, Jongcheol;Kim, Hee Yeoun;Lee, Jong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.306-310
    • /
    • 2018
  • In order to develop a highly sensitive infrared sensor, it is necessary to develop techniques for decreasing the rate of heat absorption and the transition of the absorption wavelength to a longer wavelength, both of which can be induced by decreasing the pixel size of the bolometer. Therefore, in this study, $1{\mu}m$ hole-arrays with a subwavelength smaller than the incident infrared wavelength were formed on the amorphous silicon-based microbolometer pixels in the absorber, which consisted of a TiN absorption layer, an a-Si resistance layer and a SiNx membrane support layer. We demonstrated that it is possible to reduce the thermal time constant by 16% relative to the hole-patternless bolometer, and that it is possible to shift the absorption peak to a shorter wavelength as well as increase absorption in the $4-8{\mu}m$ band to compensate for the infrared long-wavelength transition. These results demonstrate the potential for a new approach to improve the performance of high-resolution microbolometers.

Analysis of Falling-film Generator in Ammonia-water Absorption System (암모니아-물 흡수식 시스템에서 유하액막식 발생기의 해석)

  • 김병주;손병후;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.422-430
    • /
    • 2001
  • In the present study, an evaporative generation process of ammonia-water solution film on the vertical plate was analysed. For the utilization of waste heat, hot water of low temperature was used as the heat source. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. Counter-current solution-vapor flow resulted in the refrigerant vapor of the higher ammonia concentration than that of co-current flow. Eve the rectification of refrigerant vapor was observed near the inlet of solution film in counter-current flow. For the optimum operation of generator using hot water, numerical experiments, based on the heat exchange and generation efficiencies. revealed the inter-relationships among the Reynolds number of the solution film and hot water, and the length of generator. Enhancement of heat and mass transport in the solution film was found to be very effective for the improvement of generation performance, especially at high solution flow rate.

  • PDF