• 제목/요약/키워드: Heat (Mass) Transfer Coefficient

검색결과 382건 처리시간 0.021초

2성분 혼합물질의 층류 막비등에서 복사열전달의 효과 (Effect of Radiation on Laminar Film Boiling of Binary Mixtures)

  • 성현찬;김경훈
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.942-951
    • /
    • 2004
  • This paper presents the results of a theoretical study of the effect of radiation during free convective laminar film boiling for methanol/water binary mixtures on an isothermal vertical wall at atmospheric pressure. With the well-known boundary layer theory as a basis, a theoretical model has been formulated into consideration for mass diffusion at liquid phase. The equations are numerically solved by a similarity method to investigate the effects of radiation emissivity on the surface with various parameters such as wall superheat and composition of more volatile component at liquid phase far from the wall. From the results, the distributions of the physical quantifies are investigated in both phases. New correlations are proposed to predict the heat transfer coefficient of binary mixtures. It is shown that the proposed correlations are in good agreement with numerical results and with Bromley's correlation within maximum $11\%$ errors. It is also found that as the wall superheat is increased, radiation effect becomes more important.

액화석유가스 용기의 자연 증발량에 관한 연구 (A Study on the Natural Evaporation Capacity of LPG Container)

  • 조영도;김지윤
    • 한국가스학회지
    • /
    • 제5권2호
    • /
    • pp.22-29
    • /
    • 2001
  • 체적거래제에 의하여 소규모 공동주택에 가스를 공급하기 위하여 적절한 용기설치수의 결정 및 용기교체시기에 대한 검토가 필요하다. 그러나 지금까지 국내에 축적된 자료가 없을 뿐만 아니라 용기 설치수의 결정과 용기수 및 가스사용 형태에 따라 용기교체시 남아 있는 액화석유가스 양에 대한 이론적 검토가 없었다. 따라서 본 연구에서는 자연기화능력, 잔량, 용기의 온도, 용기내부 압력 등을 시뮬레이션으로 살펴보았다. 용기표면으로부터 액화석유가스 용기의 총괄 열전달계수의 변화에 따른 자연기화량 변화는 크지 않으며, 실험으로부터 구한 값은 약 $9{\~}13 kcal/m^2{\cdot}hr{\cdot}^{\circ}C$이었다. 그리고 액화석유가스 용기내부의 압력이 압력조정기의 압력조정 하한계에 도달하였을 때 가스방출 유량은 공기로부터 전달되는 열량과 균형을 이루는 일정한 값으로 급격히 감소하였다. LP가스용기의 자연기화능력은 외기온도 및 프로판의 조성에 따라 증가하였고, 연속사용시간에 따라 초기 급격히 감소하여 일정한 값으로 수렴하였다. 한 가구당 용기수는 자동절체기 사용에 의하여 감소시킬 수 있는 것을 알 수 있다.

  • PDF

유수대류계수에 관한 실험적 연구 (Experimental Study on Coefficient of Flow Convection)

  • 전상은;김국한;김진근;양주경
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.314-322
    • /
    • 2003
  • 콘크리트 구조물의 수화열 저감 방안으로 사용되는 파이프 쿨링 시스템을 적용할 경우 파이프 관 주변의 내부유동에 의한 열전달이 발생하게 된다. 이와 같은 내부유동에 의한 열전달 효과를 정확히 규명하기 위해서는 유수대류계수를 산정하여야 한다. 파이프 쿨링 효과의 규명에 필요한 유수대류계수의 영향인자로는 냉각수의 층난류 여부, 냉각수의 유동속도, 관의 형상 및 열특성 등이 있다. 본 연구에서는 유수대류계수를 산정하기 위한 실험장치를 개발하였으며, 이를 이용하여 강재 및 PVC 파이프에 대한 실험을 수행하였다. 이들 실험결과를 토대로 관의 내부표면이 매끈한 원형관이며 난류흐름을 갖는 내부유동에 대한 유수대류계수 모델식을 제안하였으며, 제안된 모델식은 냉각수의 유속뿐만 아니라 유동관의 재질 및 형상을 고려할 수 있다. 유수대류계수는 관을 흐르는 냉각수의 대류에 의한 열전달 효과를 나타내는 값으로 관의 열전도율 및 관의 직경과는 비례관계에 있으며, 관의 두께와는 반비례관계를 갖는다. 본 연구에서 개발된 유수대류계수 모델식은 이러한 영향을 잘 반영하고 있으나, 강재 파이프에 대해서만 관의 두께 및 직경에 관한 보정계수를 제시하였다. 제안된 모델식에 의한 유수대류 계수와 실험으로부터 구한 유수대류계수를 비교한 결과, 제안된 모델식이 실험값을 정확히 추정하고 있음을 알 수 있었다.

냉동저장 공동 주변의 온도분포 예측을 위한 해석해 및 수치모델 적용에 관한 연구 (Analytical and Numerical Model Study to Predict the Temperature Distribution Around an Underground Food Cold Storage Pilot Cavern)

  • 이대혁;김호영
    • 터널과지하공간
    • /
    • 제12권3호
    • /
    • pp.142-151
    • /
    • 2002
  • 대전 식품냉동저장창고 파일럿 공동주위의 거리에 따른 비정상상태의 온도 분포를 산정하기 위해 Claesson(2001)의 해석해 및 Dirichlet과 Neuman 내부 경계조건을 갖는 수치모델들을 검토하였다. 온도 강하 단계동안 일정 표면 온도 경계조건에 기초하고 있는 Claesson의 해석해를 활용한 결과, 실제 암반에서의 온도 계측결과를 오차 평균 0.89$^{\circ}C$ 수준으로서 비교적 정확히 예측할 수 있었는데, $0^{\circ}C$근처의 실험실 암석 열물성을 입력하였고 현지 암반 조건을 표현하기 위한 특별한 물성 보정을 하지 않았다. 내부 공동 암반 벽면을 통한 열유속을 갖는 수치해석의 경우, 대류 열전달계수와 공동 내부 온도가 냉각시간에 따라 변화하기 때문에 경계조건을 가하기 어려운 단점을 극복하기 위해 새로운 경계조건 설정 기법을 제안하였다. 그 결과 오차 평균 1.58$^{\circ}C$의 수준으로서 온도 계측치와 부합하였다. 또한 공동 벽면에서 고정 온도 조건을 갖는 수치해와 비교하였다. 마지막으로 Claesson의 해석해 및 다양한 내부 경계조건을 갖는 수치모델을 활용하여, 공동 주변의 온도 분포를 정확히 예측할 수 있는 일련의 해석 단계 프로그램을 제안하였다.

태양열 데시컨트 냉난방시스템 중 충진층에 있어서의 열 물질전달에 관한 연구 (Research on Heat and Mass Transfer Coefficient in the Packing Layer With a Solar Desiccant Heating/Cooling System)

  • 요한나;최광환;김부안;김동규;백기동;김지원
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.17-24
    • /
    • 2006
  • 최근에 에너지절약 차원에서 종래의 공조방식을 대신할 새로운 냉난방시스템 개발이 요구되고 있는데, 본 논문에서는 태양열 집열기를 이용하는 데시컨트 시스템 중 제습역할을 실질적으로 담당하는 제습기의 충진층 부분에서의 열 및 물질전달에 관한 일련의 해석 결과를 발표하고 있다. 제습과정에서 액체흡수제는 충진층에서 열 뿐만 아니라 물질전달을 수반하게 되는데, 이 결과 건물에 냉방 및 난방효과를 가져다 준다. 따라서 이 충진층의 최적 설계가시스템의 효율을 극대화하기 위해서는 무엇보다도 중요한데, 이를 위해서는 충진층에서의 열 및 물질전달 양상을 규명하여야 한다. 따라서 금번 실험에서는 공기와 액체흡수제와의 접촉면적을 넓히기 위해서 충진재로써 3cm(직경) ${\times}$ 3cm(높이)인 시판중인 플라스틱 재질을 사용하고, 실질적으로 40cm(너비)${\sim}$40cm(깊이)${\times}$40cm(높이)의 충진층을 직접 제작하여 실험을 행하였다. 그 결과, 공기측 열 및 물질전달 계수는 공기 온도와 밀접한 관계를 갖고 있으며, 또한 물질전달계수는 열전달계수와 같은 경향을 보이고 있음을 알 수 있었다.

상변화형 미세캡슐을 함유한 축열블럭의 열성능 특성 (Thermal Performance of the Storage Brick Containing Microencapsulated PCM)

  • 이동규;천원기;강용혁;곽희열
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.23-28
    • /
    • 1999
  • 본 논문에서는 난방용 축열보드에 응용하기 위해서 미세캡슐을 함유한 축열블럭의 열성능 특성을 조사하였다. 상변화 물질인 $CH_3COONa{\cdot}3H_2O$를 미세캡슐 형태로 제조하였고 미세캡슐 함유량이 각각 10%, 20%가 되도록 시멘트 몰타르와 혼합하여 축열블럭을 제작하였다. 축열블럭의 축열 및 방열 특성을 분석하기 위하여 유량과 유입 냉각 온도를 변화시켰다. 실험결과를 보면 미세캡슐 함유량이 증가할 수록 블럭에 축열되는 축열량은 증가를 하였고 방열시간도 증가를 하였다. 그리고 방열과정시 유량이 증가하고 유입 냉각온도가 감소함에 따라 방열시간은 감소하였다. 순수블럭(0% 미세캡슐 함유량)은 방열과정시 총괄 열전달 계수는 시간에 따라서 일정하게 유지를 하지만 축열블럭에서는 시간이 지남에 따라 증가를 하였다.

  • PDF

Runge-Kutta method for flow of dusty fluid along exponentially stretching cylinder

  • Iqbal, Waheed;Jalil, Mudassar;Khadimallah, Mohamed A.;Ayed, Hamdi;Naeem, Muhammad N.;Hussain, Muzamal;Bouzgarrou, Souhail Mohamed;Mahmoud, S.R.;Ghandourah, E.;Taj, Muhammad;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.603-615
    • /
    • 2020
  • The present manuscript focuses on the flow and heat transfer of the dusty fluid along exponentially stretching cylinder. Enormous attempts are made for fluid flow along cylinder but the study of fluid behavior along exponentially stretching cylinder is discussed lately. Using appropriate transformations, the governing partial differential equations are converted to non-dimensional ordinary differential equations. The transformed equations are solved numerically using Shooting technique with Runge-Kutta method. The influence of the physical parameters on the velocity and temperature profiles as well as the skin fraction coefficient and the local Nusselt number are examined in detail. The essential observations are as the fluid velocity decreases but temperature grows with rise in particle interaction parameter, and both the fluid velocity and temperature fall with increase in mass concentration parameter, Reynold number, Particle interaction parameter for temperature and the Prandtl number.

수소 저장용 탱크의 튜브 형상에 따른 온도분포 특성에 대한 수치해석 연구 (A Study on the Characteristics of Temperature Distribution Related to Geometry of Tube in Hydrogen Storage Vessel)

  • 오승준;윤정환;전경숙;김재규;박준홍;최정주
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.205-211
    • /
    • 2021
  • Recently, it is necessary for study on renewable energy due to environmental pollution and fossil fuel depletion. Therefore, in this study, the filling temperature according to the nozzle geometry was evaluated based on the limit temperature specified in SAEJ2601 for charging hydrogen, a new energy. There are three types of nozzles, normal, angle and round, fixed the average pressure ramp rate at 52.5 MPa/min, and the injection temperature was set at 293.4 K. As a result, the lowest temperature distribution was found in the round type, although the final temperature did not differ significantly in the three types of nozzles. In addition, Pearson's coefficient was calculated to correlate the mass flow rate with the heat transfer rate at the inner liner wall, which resulted in a strong linear relationship of 0.98 or higher.

압력용기로부터 압력방출장치를 통한 가스 방출에 관한 포괄적 고찰 (Comprehensive Consideration on the Discharge of Gases from Pressurized Vessels through Pressure Relief Devices)

  • 정창복
    • 한국안전학회지
    • /
    • 제35권6호
    • /
    • pp.32-45
    • /
    • 2020
  • The problem of determining the discharge rates of gases from pressurized vessels through pressure relief devices was dealt with comprehensively. First, starting from basic fluid flow equations, detailed modeling procedures were presented for isentropic nozzle flows and frictional flows in a pipe, respectively. Meanwhile, physical explanations were given to choking phenomena in terms of the acoustic velocity, elucidating the widespread use of Mach numbers in gas flow models. Frictional flows in a pipe were classified into adiabatic, isothermal, and general flows according to the heat transfer situation around the pipe, but the adiabatic flow model was recommended suitable for gas discharge through pressure relief devices. Next, for the isentropic nozzle flow followed by adiabatic frictional flow in the pipe, two equations were established for two unknowns that consist of the Mach numbers at the inlet and outlet of the pipe, respectively. The relationship among the ratio of downstream reservoir pressure to upstream pressure, mass flux, and total frictional loss coefficient was shown in various forms of MATLAB 2-D plot, 3-D surface plot and contour plot. Then, the profiles of gas properties and velocity in the pipe section were traced. A method to quantify the relationship among the pressure head, velocity head, and total friction loss was presented, and was used in inferring that the rapid increase in gas velocity in the region approaching the choked flow at the pipe outlet is attributed to the conversion of internal energy to kinetic energy. Finally, the Levenspiel chart reproduced in this work was compared with the Lapple chart used in API 521 Standatd.

태양열 이용 냉난방 공조시스템 중 전열교환기 성능에 관한 연구 (Research on the Performance of Total Heat Exchanger in a Solar Air-Conditioning System)

  • 김광호;최광환;금종수;김보철;김종렬
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.45-53
    • /
    • 1999
  • 본 논문은 태양열을 구동원으로 하고 액체흡수제인 염화리튬(LiCl) 용액을 이용하여 제습/냉방 및 난방을 하나의 시스템으로 이루는 태양열 이용 냉난방 공조시스템 중 여름철 전열교환기의 제습/냉방에 관한 성능실험 결과이다. 여름의 고온다습한 실내공기는 휀에 의해 전열교환기로 유입되어 충진층에서 살수된 LiCl 용액과 직접 접촉하여 제습/냉각된 후, 건조공기로 바뀌어 실내로 취출된다. 한편 수분을 흡수하여 저농도 용액으로 변한 LiCl 용액은 재생기에서 태양열에 의해 다시 고농도 용액으로 바뀌어 흡수포텐셜을 갖는다. 본 실험에서는 형상 및 크기가 다른 3가지 충진재를 사용하여 전열교환기의 제습성능을 비교하였으며, 절대습도기준 총괄 물질전달계수인 $k_xa(kg/m^3h{\Delta}x)$로써 그 성능을 평가하였다. 특히 $k_xa$값은 액체흡수제 유량, 공기 풍량, 충진재 형상 및 충진층 높이에 따라 변한다. 따라서 이에 대한 영향을 조사하기 위하여 여러 가지 실험한 결과, 풍량은 $k_xa$값에 미치는 영향이 컸으나, 유량은 그다지 영향을 미치지 않음을 알 수 있었다. 또한 충진재의 형상에 따른 비교 실험에서 충진재의 직경이 큰 경우에는 충진층 높이의 영향이 컸으나, 직경이 작은 경우에는 높이에 의한 영향이 직경이 큰 경우보다 작았다. 이상의 실험 결과로부터 $k_xa$값을 충진재 형상 및 충진층 높이에 따라 정지하면 최적 전열교환기 설계 및 제작에 기초자료로 활용할 수 있음을 알았다.

  • PDF