• Title/Summary/Keyword: HeartBeat

Search Result 173, Processing Time 0.025 seconds

A Study on Emotional Lighting using Fluid Coloring (동적인 색변화를 이용한 감성 조명에 관한 연구)

  • Jeong, Woo-Seob;Jeong, Da-Gun;Heo, Jeong-Soo;Yoon, Jae-Won;Lee, Seung-Dae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.933-940
    • /
    • 2017
  • This thesis shows the emotional light that stabilizes various human heart rates through the three elements of LED. This experiments confirm the change of heart rates when subjects see the static LED, fluid LED That was controlled by the guitar chord and beat in a given music and without light Consequently, the experiment proved that the bpm slope of test subject during specific time in liquid LED, -12.85, was steeper than -12.05 in static LED and -11.05 without light, which showed that fluid LED is more effective to stabilize heart rate than other conditions.

Posture Change Affects Indices of Pupil Size - Korean Males in Their Twenties

  • Lee, Jeung-Chan;Kim, Ji-Eun;Park, Kyung-Mo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • To determine the effect of posture change on autonomic activity and to investigate valid parameters to reflex the autonomic activity from time-series pupil size data, a posture-related experiment was performed with 15 subjects, which involved measuring their electrocardiograms and pupil sizes. The experimental procedure consisted of three-sequence postures-supine, sitting and upright-for 5 minutes each, with rest sessions between postures. The subjects were notified of the entire experimental procedure. The parameters of the subjects' heart rate variability showed significant differences between the postures (heart rate: 63-70-80 beat, normalized low frequency power: 28-50-75, normalized high frequency power: 72-49-25 and ratio: 0.5-1.2-4.4 in supine-sitting-upright position respectively) as did the parameters of their mean pupil sizes (41300-53900-53700 pixels respectively) and the major frequencies (the third trend: 0.23-0.2-0.18 Hz respectively) of their pupil size variability according to changes in their autonomic activities induced by posture change. The experiment thus proved that posture change affects autonomic activity and that such activity can be estimated by the parameters of pupil size as similar as heart rate variability.

Heart Rate Monitoring Using Motion Artifact Modeling with MISO Filters (MISO 필터 기반의 동잡음 모델링을 이용한 심박수 모니터링)

  • Kim, Sunho;Lee, Jungsub;Kang, Hyunil;Ohn, Baeksan;Baek, Gyehyun;Jung, Minkyu;Im, Sungbin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.8
    • /
    • pp.18-26
    • /
    • 2015
  • Measuring the heart rate during exercise is important to properly control the amount of exercise. With the recent advent of smart device usage, there is a dramatic increase in interest in devices for the real-time measurement of the heart rate during exercise. During intensive exercise, accurate heart rate estimation from wrist-type photoplethysmography (PPG) signals is a very difficult problem due to motion artifact (MA). In this study, we propose an efficient algorithm for an accurate estimation of the heart rate from wrist-type PPG signals. For the twelve data sets, the proposed algorithm achieves the average absolute error of 1.38 beat per minute (BPM) and the Pearson correlation between the estimates and the ground-truth of heart rate was 0.9922. The proposed algorithm presents the strengths in an accurate estimation together with a fast computation speed, which is attractive in application to wearable devices.

Norwood Procedure on Beating Heart (심장 박동을 유지하면서 시행한 Norwood 술식)

  • 곽재건;최창휴;김진현;정요천;오세진;이정렬;김용진;노준량;김웅한
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.793-795
    • /
    • 2004
  • Modified Norwood procedure with maintaining cardiac beat was done in a 30-day-old neonate. Procedure was done with regional perfusion of innominate and coronary artery. Postoperative course was uneventful. Second-stage operation (bi-directional cavopulmonary shunt) was done 4 months later. The diameter of ascending aorta was more than 5 mm, Norwood procedure can be done in beating hearts.

Changes of the Electrocardiogram and Blood Picture of Frogs in Four Seasons (개구리 심전도(EKG) 및 혈액상의 계절에 따른 변화)

  • Rhee, Jung-Moo;Bae, Sung-Ho;Shin, Hyun-Chan;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.33-44
    • /
    • 1974
  • The electrocardiogram of frogs were obtained in winter (January), spring (April), summer (July) and autumn (September and November). Electrocardiograms were recorded applying electrodes to the atria, ventricle and apex of the heart by unipolar or bipolar leads. V wave was recorded prior to P wave, for the presence of the sinus venosus which controls the automaticity of the frog heart, in four seasons. Regardless of the leads or the position of the electrodes P wave was diphasic and wide. According to the rise of temperature the rate of heart beat was increased, and V-P and P-R interval were shortened. Two regression line between R-R interval and both V-P interval and P-R interval were drawn. These were calculated as V-P interval=1 0.276R-R $interva1+0.067{\pm}0.15$ (sec.) and P-R interval=0.179R-R $interva1+0.155{\pm}0.1$ (sec). From these calculation the larger gradient of V-P interval than P-R interval was suggestive that the heart rate is more dependent on the changes of V-P interval than that of P-R interval. Changes of the heart rate were also measured in four seasons and artificial temperatures. Two regression lines between the heart rate (H.H.) and both seasonal temperature (T) and artificial temperature, were drawn. These two lines were calculated as H.R.=20+3.71 (T-10) and H.R.=32+1.425 T respectively. From two gradients of the above equations it is considered that the changes of the heart rate in artificial temperature were milder than that in seasonal temperature. The number of RBC and WBC of frogs were measured in four seasons and a tendency of the changes was observed according to the seasonal variation.

  • PDF

The Comparison of Heart Rate and Energy Expenditure between Male and Female During Twist Exercise (트위스트 운동 시 성별에 따른 심박수와 에너지 소모량의 비교)

  • Jeon, Byeong-Hwan
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.1
    • /
    • pp.243-252
    • /
    • 2015
  • The present study, to examine the effect of the exercise for weight control, compares the difference of the heart rate and energy expenditure by sex during Twist exercise. Twenty eight adults (male 14, female 14) were carried out Twist exercise for 7 minutes and 14 minutes. During performing the exercise program, to perform HR and related variables were measured for 7 minutes and 14 minutes. Through a twist exercise treatment and the following results were obtained. 1. Females had slightly higher, without statistical significance, number of heart beat, minimum heart rate, maximum heart rate, and average heart rate than male had for both 7 minutes and 14 minutes of Twist exercise. 2. In the case of energy consumption, significant differences did not appear until 7 minutes to perform Twist exercise. On the other hand, the energy consumption for 14 minutes of performance was significantly higher in male than in female (p<.05). However, energy expenditure for the period per minute per unit weight (kcal/min/kg) showed no difference. 3. If more than 30 minutes duration were preformed the Twist exercise, males were expected to consume significantly higher than females (p<.05). To consume calories for the 10,000 step walk of, it would be required about 76 minutes for Twist exercise time without distinction of sex. Through the above findings, twist exercise is a form of aerobic exercise for obesity prevention and weight control, as well as it might be beneficial to practice and maintain the health and physical fitness with offering a variety of exercise opportunities in the public.

Experimental Study on the Effects of Chungyeuldodamtang upon Hypertension and Hyperlipidemia (고혈압(高血壓) 및 고지혈증(高脂血症)에 대(對)한 청열도담탕(淸熱導痰湯)의 실험적(實驗的) 연구(硏究))

  • Lee, Dai-Sik;Shin, Gil-Cho;Cho, Ki-Ho;Kim, Young-Suk;Bai, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Internal Korean Medicine
    • /
    • v.12 no.2
    • /
    • pp.16-25
    • /
    • 1991
  • Mahwangsan is used in the treatment of asthma due to wind and cold(風寒喘). This is study was carried out to investigate the effect of Mahwangsan extract and In order to investigate the effects of Chungyeuldodamtang experimental studies were performed in hyperlipidemia Rats induced by cholesterol and Spontaneusly hypertension rats. The contents of serum total cholesterol, triglyceride, phospholipid and FFA and the changes of blood pressure and heart beat were measured. The results were summarized as follows ; 1. The content of Total-Cholesterol in the serum compared with control group tended to be decreased in Chungyeuldodamtang group, but did not show a significance. 2. The content of Triglyceride in the serum was significantly decreased in Chungyeuldodamtang group. 3. The content of Phospholipid in the serum was significantly decreased in Chungyeuldodamtang group. 4. The content of FFA in the serum tended to decreased in Chungyeuldodamtang group, but did not show a significance. 5. The S.H.R's blood pressure was significantly decreased in Chungyeuldodamtang group. 6. The S.H.R.'s Heart beat compared with control group tended to be decreased in Chungyeuldodamtang group, but did not show a significance. According to the above results, it is assumed that Chungyeuldodamtang has a valid effect on Hypertension and Hyperlipidemia.

  • PDF

Development of Pressure Sensor on Polymer Substrate for Real-time Pulse and Blood Pressure Measurements (실시간 맥박 및 혈압 측정을 위한 폴리머 기판 압력센서 개발)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.669-676
    • /
    • 2013
  • In this study, we introduce a polymer(polyimide) based pressure sensor to measure real-time heart beat and blood pressure. The sensor have been designed with consideration of skin compatibility of material, cost effectiveness, manufacturability and wireless detection. The designed sensor was composed of inductor coils and an air-gap capacitor which generate self-resonant frequency when electrical source is applied on the system. The sensor was obtained with metalization, etching, photolithography, polymer adhesive bonding and laser cutting. The fabricated sensor was shaped in circular type with 10mm diameter and 0.45 mm thickness to fit radial artery. Resonant frequencies of the fabricated sensors were in the range of 91~96 MHz on 760 mmHg pressurized environment. Also the sensor has good linearity without any pressure-frequency hysteresis. Sensitivity of the sensor was 145.5 kHz/mmHg and accuracy was less than 2 mmHg. Real-time heart beat measurement was executed with a developed hand-held measurement system. Possibility of real-time blood pressure measurement was showed with simulated artery system. After installation of the sensor on skin above radial artery, simple real blood pressure measurement was performed with 64 mmHg blood pressure variation.

Non-Contact Vital Signal Sensor Based on Impedance Variation of Resonator (공진기의 임피던스 변화에 근거한 비접촉 생체 신호 센서)

  • Kim, Kee-Yun;Kim, Sang-Gyu;Hong, Yunseog;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.813-821
    • /
    • 2013
  • In this paper, a vital signal sensor based on impedance variation of resonator is presented. Proposed vital signal sensor can detect the vital signal, such as respiration and heart-beat signal. System is composed of resonator, oscillator, surface acoustic wave (SAW) filter, and power detector. The cyclical movement of a dielectric such as a human body, causes the impedance variation of resonator within the near-field range. So oscillator's oscillation frequency variation is effected on resonator's resonant frequency. SAW filter's skirt characteristic of frequency response can be transformed a small amount of frequency deviation to a large variation. Aim to enhance the existing sensor detection range, proposed sensor operates in 870 MHz ISM band, and detect respiration and heart-beat signal at distance of 120 mm.

Effect of Transient Isokinetic Exercise on Cardiac Autonomic Nervous Modulation and Muscle Properties (일회성 등속성 운동이 심장 자율신경 조절 및 근속성에 미치는 영향)

  • Soo-Kyoung Park;Si-Eun Park
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.4
    • /
    • pp.27-39
    • /
    • 2023
  • Purpose : The aim of this study was to identify the influence of transient isokinetic exercise on cardiac autonomic modulation and muscle properties in healthy male subjects. Methods : Twenty-eight healthy males underwent isokinetic exercise of both knee joints using a Biodex systems 3 isokinetic dynamometer with an angular velocity of 60 °/sec. The changes in activity of the autonomic nervous system, as determined by heart rate variability (HRV), and in muscle properties were evaluated at three times: pre-exercise, immediately post-exercise, and 10 min post-exercise. Results : The time domain analysis of HRV revealed significant changes in the beat count and mean and minimal heart rate (HR) measured at pre-exercise, immediately post-exercise, and 10 min post-exercise (p<.001). The beat count and mean HR were markedly increased immediately post-exercise compared to pre-exercise, but then significantly decreased at 10 min post-exercise (p<.001). All parameters of the frequency domain were significantly altered by isokinetic exercise (p<.01). The low frequency/high frequency (LF/HF) ratio, as an index for the sympathovagal balance, was elevated by exercise and remained at a similarly high level at 10 min post-exercise (p<.01). The muscle properties of rectus femoris were changed as follows: Muscle tone and stiffness were significantly increased between pre-exercise and immediately post-exercise (p<.001), and between pre-exercise and at 10 min post-exercise (p<.001). Whereas, the elasticity showed no significant change. Conclusion : These results demonstrated that transient isokinetic exercise could induce changes in cardiac autonomic control and muscle properties. In particular, up-regulation of LF/HF ratio after exercise signifies thus enhanced sympathetic modulation by isokinetic exercise. Therefore, it is needed to understand the cardiovascular risks that may arise during isokinetic exercise for providing the basic evidence to establish appropriate isokinetic exercise protocols as effective rehabilitation exercises.