• Title/Summary/Keyword: Heart rate estimation

Search Result 64, Processing Time 0.03 seconds

Sleep Apnea Detection using Estimated Stroke Volume (추정된 일회심박출량을 이용한 수면 무호흡 검출)

  • Lee, Junghun;Lee, Jeon;Lee, Hyo-Ki;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.97-103
    • /
    • 2013
  • This paper proposes a new algorithm for sleep apnea detection based on stroke volume. It is very important to detect sleep apnea since it is a common and serious sleep-disordered breathing (SDB). In the previous studies, methods for sleep apnea detection using heart rate variability, airflow and blood oxygen saturation, tracheal sound have been proposed, but a method using stroke volume has not been studied. The proposed algorithm consists of detection of characteristic points in continuous blood pressure signal, estimation of stroke volume and detection of sleep apnea. To evaluate the performance of algorithm, the MIT-BIH Polysomnographic Database provided by Phsio- Net was used. As a result, the sensitivity of 85.99%, the specificity of 72.69%, and the accuracy of 84.34%, on the average were obtained. The proposed method showed comparable or higher performance compared with previous methods.

Analysis of Change Rate of SBP and DBP Estimation Fusion Algorithm According to PTT Measurement change PPG Pulse Wave Analysis (PPG 맥파 분석의 PTT 측정변화에 따른 SBP, DBP 추정 융합 알고리즘 변화율 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.7
    • /
    • pp.35-40
    • /
    • 2020
  • Recently, devices such as smart watches capable of measuring small biosignals have been released. Body composition, blood pressure, heart rate, and oxygen saturation can be easily obtained. However, the part that is not trusted by the user is accuracy. These biosignals are sensitive to the external environment and have large fluctuations depending on the conditions inside the subject's body. Blood pressure measurements, in particular, still give different results, depending on how the conditions in the body are handled. Therefore, in this study, PPG was analyzed to measure PTT at two points of 80% and 100%, the highest in PTT measurement. The effect of the measured value on SBP and DBP was analyzed and a method was proposed to increase the accuracy. As a result of the study, the measured value of PTT at 80% of the peak PPG is more effective in estimating blood pressure of SBP and DBP than the value measured at 100%. In the regression analysis of the rate of change blood pressure estimation, the coefficient of determination of SBP (80%) was 0.6946, and DBP (100%) was 0.547.

The Pyramid of Injury: Estimation of the Scale of Adolescent Injuries According to Severity

  • Han, Hyejin;Park, Bomi;Park, Bohyun;Park, Namsoo;Park, Ju Ok;Ahn, Ki Ok;Tak, Yang Ju;Lee, Hye Ah;Park, Hyesook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.51 no.3
    • /
    • pp.163-168
    • /
    • 2018
  • Objectives: Due to their developmental characteristics, adolescents have a higher probability than other age groups of experiencing injuries caused by accidents, violence, and intentional self-harm. The severity and characteristics of injuries vary by the intentionality and mechanism of injury; therefore, there is a need for a national-level estimate of the scale and the severity of injuries in adolescents that takes these factors into account. Methods: By using data from the Emergency Department-based Injury In-depth Surveillance Data, National Emergency Department Information System, the Korean National Hospital Discharge In-depth Injury Survey, and cause of death statistics, we calculated the emergency department (ED) visit rate, hospitalization rate, and death rate of injuries per 100 000 adolescents for each injury mechanism. The calculated rates were used to generate the injury pyramid ratio (ratio of death rate to hospitalization rate to ED visit rate) to visualize the scale and the severity of the injury. Results: The mortality rate in adolescents due to injury was 10/100 000; the corresponding rates for hospitalization and ED visits were 1623 and 4923, respectively, resulting in an injury pyramid ratio with the general pyramid form, with a 1:162:492 ratio of deaths to hospitalizations to ED visits. The mortality rate due to suicide/intentional self-harm was 5/100 000, while 35 were hospitalized for this reason and 74 made ED visits. The pyramid ratio of 1:7:15 for intentional self-harm/suicide showed a steep pyramidal form, indicating considerable lethality. The mortality rate due to motor vehicle collisions (MVCs) was 3/100 000; 586 were hospitalized for this reason, while 1023 made ED visits. The pyramid ratio of 1:195:341 for MVCs showed a gradual pyramid form, indicating that the lethality was low and the scale of injury was high. Conclusions: The main categories of injuries in adolescents were visualized in pyramid form, contributing to an understanding of the scale of each injury by mechanism in terms of levels of death, hospitalization, and ED visits. These findings will be helpful for understanding how to prioritize injuries in adolescents.

A Study on the Estimation of Limits to Life Expectancy (한국인 기대여명의 한계추정에 관한 연구)

  • 천성수;김정근
    • Korea journal of population studies
    • /
    • v.16 no.2
    • /
    • pp.65-83
    • /
    • 1993
  • The purpose of this study is estimate limits of Korean life expectancy at birth by 'Gompertz growth curse Model', 'Cause-Elimination Model' and Multidimensional models of Senescencee and Mortality'. Data used in Gompertz curve were obtained from all life tables published from 1905 to 1990 in Korea, and life expectancies at birth of eighteen groups were selected at five-year interval in consideration of time-series changes. Data used in Cause-Elimination Model are 'Cause of Death statistics in 1991' published in 1992 by National Bureau of Statistics of Korea and 'life table of 1989' published in 1990 by National Bureau of Statistics, Economic Planning Board of Korea. The materials are all classifiable death data, 119, 253 cases of male and 82, 420 cases of female, which is from 1991 Causes of Death statistics. The cases of death analyzed belong to one of 8 categories; i.e., Infectious and Parasitic Diseases(001-139; with notation of Infectious Diseases), Malignant Neoplasms(140-208), Hypertensive Diseases(401-405), Ischemic Heart Dieases and Diseases of Pulmonary Circulation and Other Forms of Heart Diseases(410-429;with notation of Heart Disease), Cerebrovascular Diseases(430-438), Chronic Liver Diseases and Cirrhosis(571; with notation of Liver Diseases), Injury and Poisoning(800-999) and all other disease. Data used in 'Multidimensional models of senescence and mortality' were life table of 1989 published by National Bureau of statistics, Economic Planning Board of Korea and life table of 1970, 1978-79, 1983, 1985 and 1987. The major findings may be summarised as follows: 1. Estimate equations of Gompertz growth curve using life expectancy at birth during the 1905-1990 period are as the following. Male : y = 88.047697 $\times$ $0.199690^{0.903381x}$ Female : y = 95.632828 $\times$ $0.199690^{0.903381x}$ Limits of life expectancy at birth, which were estimated by Gompertz growth curve, are 88.05 for male and 95.63 for female. 2. The effect on life expectancy at birth eliminationg all causes death is 14.04 years(for male) and 10.86 years(for female). Astonishingly, eliminating the malignant neoplasms increase life expectancy at birth by 2.85 years for male 2.03 years for female in 1991. In table 8 we show the effect on life expectancy at birth of separately eliminating each of the 8 categorical causes of death. The theoretical limit to life expectancy by Cause-Elimination Model is 80.96 for male and 85.82 for female. 3. If the same rate of delay [0.376 year(male), 0.435 year(femable) per calendar year] continued, then life expectancy at birth would reach 74.82(male) years and 84, 10(female) years in 2010. With 14.04-years(male) and 10.86-years(female) effect attributable in 2010 would be 88.86 years(male) and 94.96(femable) years. 4. 'Multidimensional models of senescence and death' permits calculations of the value of the attribution coefficient (B), percent of loss per year of physiologic function. The results of Ro and B during the 1970-1989 period are listed in table 9. Estimate of limit to Korean life expectancy at birth by 'Multidimensional models of senescence and death' is 99.47 years for male and 104.74 years for female in 1989.

  • PDF

Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation (혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가)

  • Kim, Yoo-Seok;Park, Seong-Min;Shim, Eun-Bo;Choi, Seong-Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

Evidence-based estimation of health care cost savings from the use of omega-3 supplementation among the elderly in Korea

  • Hwang, Ji-Yun;Kim, Wu Seon;Jeong, Sewon;Kwon, Oran
    • Nutrition Research and Practice
    • /
    • v.9 no.4
    • /
    • pp.400-403
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: By the year 2050, thirty-eight percent of the Korean population will be over the age of 65. Health care costs for Koreans over age 65 reached 15.4 trillion Korean won in 2011, accounting for a third of the total health care costs for the population. Chronic degenerative diseases, including coronary heart disease (CHD), drive long-term health care costs at an alarming annual rate. In the elderly population, loss of independence is one of the main reasons for this increase in health care costs. Korean heath policies place a high priority on the prevention of CHD because it is a major cause of morbidity and mortality. SUBJECTS/METHODS: This evidence-based study aims to the estimate potential health care cost savings resulting from the daily intake of omega-3 fatty acid supplementation. Potential cost savings associated with a reduced risk of CHD and the medical costs potentially avoided through risk reduction, including hospitalizations and physician services, were estimated using a Congressional Budget Office cost accounting methodology. RESULTS: The estimate of the seven-year (2005-2011) net savings in medical costs resulting from a reduction in the incidence of CHD among the elderly population through the daily use of omega-3 fatty acids was approximately 210 billion Korean won. Approximately 92,997 hospitalizations due to CHD could be avoided over the seven years. CONCLUSIONS: Our findings suggest that omega-3 supplementation in older individuals may yield substantial cost-savings by reducing the risk of CHD. It should be noted that additional health and cost benefits need to be revisited and re-evaluated as more is known about possible data sources or as new data become available.

Real Time ECG Derived Respiratory Extraction from Heart Rate for Single Lead ECG Measurement using Conductive Textile Electrode (전도성 직물을 이용한 단일 리드 심전도 측정 및 실시간 심전도 유도 호흡 추출 방법에 관한 연구)

  • Yi, Kye-Hyoung;Park, Sung-Bin;Yoon, Hyoung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.335-343
    • /
    • 2006
  • We have designed the system that measure one channel ECG by two electrode and extract real-time EDR with more related resipiration and comportable to subject by using conductive textile. On the assumption that relation between RL electrode and potential measurement electrode is coupled with RC connected model, we designed RL drive output to feedback two electrode for reduction of common mode signal. The conductive textile which was used for two ECG electrode was offered more comfort during night sleep in bed than any other method using attachments. In the method of single-lead EDR, R wave point or QRS interval area could be used for EDR estimation in traditional method, it is, so to speak, the amplitude modulation(AM) method for EDR. Alternatively, R-R interval could be used for frequency modulation(FM) method based on Respiratory Sinus Arrhythmia(RSA). For evaluation of performance on AM EDR and FM EDR from 14 subject, ECG lead III was measured. Each EDR was compared with both temperature around nose(direct measurement of respiration) and respiration signal from thoracic belt(indirect measurement of respiration) on mean squared error(MSE), cross correlation(Xcorr), and Coherence. The upsampling interpolation technique of multirate signal processing is applied to interpolating data instead of cubic spline interpolation. As a result, we showed the real-time EDR extraction processing to be implemented at micro-controller.

The process of estimating user response to training stimuli of joint attention using a robot (로봇활용 공동 주의 훈련자극에 대한 사용자 반응상태를 추정하는 프로세스)

  • Kim, Da-Young;Yun, Sang-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1427-1434
    • /
    • 2021
  • In this paper, we propose a psychological state estimation process that computes children's attention and tension in response to training stimuli. Joint attention was adopted as the training stimulus required for behavioral intervention, and the Discrete trial training (DTT) technique was applied as the training protocol. Three types of training stimulation contents are composed to check the user's attention and tension level and provided mounted on a character-shaped tabletop robot. Then, the gaze response to the user's training stimulus is estimated with the vision-based head pose recognition and geometrical calculation model, and the nervous system response is analyzed using the PPG and GSR bio-signals using heart rate variability(HRV) and histogram techniques. Through experiments using robots, it was confirmed that the psychological response of users to training contents on joint attention could be quantified.

Estimation of PM10 and PM2.5 inhalation dose by travel time and respiratory volume in common transport microenvironments in Seoul, Korea (서울지역 교통수단별 이동시간과 호흡량을 고려한 미세먼지 흡입량 추정에 관한 연구)

  • Lee, Yong-Il;Jung, Wonseck;Hwang, Doyeon;Kim, Taesung;Park, Duckshin
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.97-105
    • /
    • 2018
  • Recently, people's interest in particulate matter (PM) has been increasing, due to its hazardous health effects. The purpose of this study was to investigate the concentrations and as well as the inhaled weight of PM, correlated with person's heart rate in subway, bus, vehicle and bicycle in the major public transportation (Sadang - Jamsil and Nowon - Dongdaemun) in Seoul. The concentration of $PM_{10}$ and $PM_{2.5}$ were measured from each of transportation means and calculated the average concentrations which were 87.2 and $57.8{\mu}g/m^3$ for subway, 62.8 and $42.5{\mu}g/m^3$ for vehicle, 61.5 and $36.8{\mu}g/m^3$ for bus and 53.0 and $29.4{\mu}g/m^3$ for bicycle in $PM_{10}$ and $PM_{2.5}$ respectively. Inhalation dose for $PM_{10}$ and $PM_{2.5}$ were estimated at 248.1 and $139.4{\mu}g$ for bicycle, 56.7 and $39.3{\mu}g$ for vehicle, 49.4 and $29.9{\mu}g$ for bus and 44.3 and $29.1{\mu}g$ for subway, respectively. Even though subway had the highest concentration, the highest inhalation dose was the bicycle. It was due to the long travel time-exposure and breathing rate which leads to maximum of $PM_{10}$ 5.6 and $PM_{2.5}$ with 4.8 times inhalation dose comparing with other modes of transportation. With regards to future studies, the amount of inhalation in each transportation means should be considered in risk assessments of PM.