• Title/Summary/Keyword: Heart atrium

Search Result 256, Processing Time 0.021 seconds

Plasma Levels of Brain Natriuretic Peptide Predict Postoperative Atrial Fibrillation in Patients Undergoing Heart Surgery (심장 수술 후 심방세동 발생의 예측 인자로서 혈중 BNP 농도)

  • Kwon, Jin-Tae;Jung, Tae-Eun;Lee, Jang-Hoon;Lee, Dong-Hyup
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.407-413
    • /
    • 2007
  • Background: The brain natriuretic peptide (BNP) level has been reported in some studies to be associated with the occurrence of atrial fbrillation (AF). The aim of this study is to evaluate the potential usefulness of the BNP level as a predictor of the occurrence of postoperative (postop) AF and to assess the relationship of the BNP level with the onset of AF and the restoration of sinus rhythm. Material and Method: From January 1, 2005 to February 28, 2006, 82 patients without a history of atrial arrhythmia that had undergone cardiac surgery were enrolled in the study. Blood samples for plasma BNP were drawn daily for all these patients from the preoperative (preop) day to the 7th postop day. The patient records were reviewed and postop EKGs were checked daily for AF until the time of discharge. Result: Patients were divided into two groups based on development of postop AF. Postoperative AF developed in 26 patients (31.7%). There was no significant statistical difference in age, sex distribution, preop left ventricle ejection fraction, hypertension, left ventricular hypertrophy, or the use of beta blockers between the non-postop AF and postop AF group. More patients in the AF group had undergone valve surgery (39.3% versus 76.9%, p=0.002). The preop left atrium size was significantly larger in the AF patients ($43.8{\pm}10.3 mm$ versus $49.8{\pm}11.5 mm$, p=0.029). The preop plasma BNP levels were higher in the postop AF patients ($144.1{\pm}20.8 pg/mL$ versus $267.5{\pm}68 pg/mL$, p=0.034). In the postop AF group, the plasma BNP level was the highest on the 3rd postop day. Postop AF developed in most patients by the 3rd postop day; restored sinus rhythm developed by the 7th postop day. Conclusion: Elevated plasma BNP levels may lead to the occurrence of postop AF in patients undergoing cardiac surgery. Patients who have a high risk of postop AF should be considered for aggressive prophylactic antiarrhythmic therapy.

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF

Clinical Analysis of Infective Endocarditis (감염성 심내막염의 임상적 고찰)

  • Kim, Hyuck;Kim, Young-Hak;Chung, Won-Sang;Shin, Kyung-Wook;Kim, Ji-Hoon
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.619-626
    • /
    • 2010
  • Background: The indications and the optimal time of surgery of infective endocarditis are controversial. We report the surgical results of our hospital during the last 10 years with literature review. Material and Method: Between January 2000 and December 2009, we enrolled 23 infective endocarditis patients who underwent surgery, and analyzed retrospectively. In the preoperative blood culture, 8 cases (34.8%) were positive. The average preoperative antibiotics treatment period was $20.78{\pm}16.00$ days. There were 12 (52.2%) urgent operations. The average follow up period was $49.26{\pm}33.21$ months. Result: 20 mechanical valve replacements were performed, 9 in aortic position, 8 in mitral position and 3 in the both positions. The other procedures were one mitral valvuloplasty, one infected myxoma extirpation, and one infected pacemaker lead removal with debridement. The average period of postoperative intravenous antibiotic treatment was $24.39{\pm}15.98$ days. There were 5 complications, including 2 cases of postoperative bleeding, one postcardiotomy syndrome, one cerebral ischemia, and a low cardiac output syndrome. There were statistically significant postoperative improvement in NYHA class, left ventricle end diastolic/end systolic volume, and left atrium size (p-value < 0.05). Conclusion: We could obtain the satisfactory results without any moftalities by using sufficient preoperative antibiotics in hemodynamically stable patients, and by prompt surgery in unstable patients.

Partial Anomalous Pulmonary Venous Connection to the Superior Vena Cava

  • Lee, Sub;Kim, Han-Woong;Kang, Hyoung-Seok;Bae, Chi-Hoon;Jheon, Sang-Hoon;Kwon, Oh-Choon;Ahn, Wook-Su
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.672-679
    • /
    • 2001
  • Background: Surgical correction of partial anomalous pulmonary venous connection to the superior vena cava has been associated with postoperative venous obstruction and sinus node dysfunction. In this paper we describe our current approach and its short-term results. Material and Method: Between April 1999 and January 2000, 5 consecutive patients, ranging from 2 months to 66 years old, underwent corrective operation for partial anomalous pulmonary venous connection to the superior vena cava at Sejong General Hospital and Daegu Catholic University Medical Center. Surgical correction involved diversion of the pulmonary venous drainage to the left atrium using a right atrial flap(2 patients) or prosthetic patch(3 patients) with division of the superior vena cava superior to the restore site of the pulmonary veins and reimplantation on the right atrial appendage to restore systemic venous drainage. Result: All patients were discharged between postoperative day 9 and 15 without complications. One Russian boy returned to his country, therefore, he was lost to follow-up after discharge. Remaining 4 patients were asymptomatic and in normal regular sinus rhythm at a mean follow-up of 17.75$\pm$4.27 months. Follow-up echocardiographic study (range, 12 to 24 months) revealed no incidence of narrowing of the venous pathways or of residual shunt. Conclusion: Our current approach is relatively simple and reproducible in achieving unobstructive pulmonay venous and SVC pathways. By avoiding incision across the cavoatrial junction, surgical injury to the sinus node and its artery may be minimized. The presented surgical technique can be safely and effectively applied to the selected patients.

  • PDF

Early Results of Maze III Operation Without Cryoablation (냉동절제 없이 시행한 Maze III 술식의 조기 결과)

  • 김형수;이원용;오동진;지현근;홍기우;두영철
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.255-261
    • /
    • 1999
  • Background: Atrial fibrillation is one of the most prevalent of all arrhythmias and in up to 79% of the patients with mitral valve disease. This study examined whether the atrial fibrillation that occur in patients with mitral valve operation could be eliminated by a concommitant maze operation without cryoablation. Material and Method: From May 1997 to April 1998, 14 patients with atrial fibrillation associated with mitral valve disease underwent Maze III operation without cryoablation. Preoperatively there were 6 men and 8 women with an average age of 46.2${\pm}$10.7 years. Eleven patients had mitral stenosis, and three had mitral insufficiency. The associated heart diseases were aortic valve disease in 4, tricuspid valve regurgitation in 1 and ASD in 2. Using transthoracic echocardiography, the mean left atrial diameters was 54.7${\pm}$5.3 mm and thrombi were found in the left atrium of 2 patients. Postoperatively the ratio between the peak speed of the early filling wave and that of the atrial contraction wave (A/E ratio) was determined from transmitral flow measurement. Operations were mitral valve replacement in 13 including 4 aortic valve replacements, 1 DeVega annuloplasty and 2 ASD closures. Maze III operation was performed in 1 patient. Result: Five patients (38%) had recurred atrial fibrillation, which was reversed with flecainide or amiodarone at the average time of postoperative 38.8${\pm}$23.5 days. Postoperative complications were postoperative transient junctional rhythm in 6, transient atrial fibrillation in 5, reoperation for bleeding in 3, postpericardiotomy syndrome(1), unilateral vocal cord palsy(1), postoperative psychosis(1), and myocardial infarction(1). Postoperatively A/E ratio was 0.43${\pm}$0.22 and A wave found in 9(64%) patients. 3 to 14 months postoperatively (average follow- up, 8.1 months), all of patients had normal sinus rhythm and 9(64%) patients had left atrial contraction and 11(79%) patients were not on a regimen of antiarrhythmic medication. Conclusion: We conclude that Maze III operation without cryoablation is an effective surgical treatment in atrial fibrillation associated with the mitral valve disease.

  • PDF

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.