• Title/Summary/Keyword: Healthcare quality assurance

Search Result 38, Processing Time 0.024 seconds

Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T (3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.31-37
    • /
    • 2021
  • This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

Assessing the Quality for Blood Transfusion Service since the 1st National Quality Assessment Program in South Korea (국내 1차 수혈 적정성 평가 시행에 따른 수혈서비스 질관리 현황)

  • Jin-Ah Kwon;Eun-Jeong Cho;A-Hyun Jung;Dong-Sook Kim
    • Quality Improvement in Health Care
    • /
    • v.28 no.2
    • /
    • pp.30-38
    • /
    • 2022
  • Purpose: The Health Insurance Review and Assessment Service (HIRA) in South Korea initiated a quality assessment (QA) program for blood transfusion healthcare services in 2020 to ensure patient safety and appropriate blood use. This study examines the quality of blood transfusion services since the first national QA program for blood transfusion services in Korea. Methods: We analyzed HIRA claims and QA investigation data based on inpatient medical records from all tertiary, general, and primary hospitals between October 2020 and March 2021. The target population was patients aged 18 years and older who received either total knee arthroplasty or red blood cell transfusion. The QA indicators for transfusion healthcare service consisted of four quality indicators and four monitoring indicators. Results: We analyzed the results of QA indicators for transfusion service from the medical records of 189,668 patients from 1,171hospitals and expressed indicators as proportions. The average results for evaluation indicators were as follows: transfusion checklist presence, 64.8%; irregular antibody tests, 61.8%; transfusions in which the hemoglobin levels before transfusion met the transfusion guidelines for patients undergoing total knee arthroplasty, 20.6%, and transfusions in patients undergoing total knee arthroplasty, 59.3%. The average results for monitoring indicators were as follows: transfusion management implementation in medical institutions, 56.9%; preoperative anemia management in anemia patients undergoing total knee arthroplasty, 43.9%; one-unit transfusions, 82.5%; and the transfusion index. Conclusion: The quality of blood transfusion healthcare varied and the assessment revealed that there is scope for improvement. Hospitals require more effective blood transfusion management and this can be facilitated by providing feedback on the QA results about blood transfusion healthcare services to medical institutions, and by disclosing the results to the public.

Sleep Quality and Poor Sleep-related Factors Among Healthcare Workers During the COVID-19 Pandemic in Vietnam

  • Thang Phan;Ha Phan Ai Nguyen;Cao Khoa Dang;Minh Tri Phan;Vu Thanh Nguyen;Van Tuan Le;Binh Thang Tran;Chinh Van Dang;Tinh Huu Ho;Minh Tu Nguyen;Thang Van Dinh;Van Trong Phan;Binh Thai Dang;Huynh Ho Ngoc Quynh;Minh Tran Le;Nhan Phuc Thanh Nguyen
    • Journal of Preventive Medicine and Public Health
    • /
    • v.56 no.4
    • /
    • pp.319-326
    • /
    • 2023
  • Objectives: The coronavirus disease 2019 (COVID-19) pandemic has increased the workload of healthcare workers (HCWs), impacting their health. This study aimed to assess sleep quality using the Pittsburgh Sleep Quality Index (PSQI) and identify factors associated with poor sleep among HCWs in Vietnam during the COVID-19 pandemic. Methods: In this cross-sectional study, 1000 frontline HCWs were recruited from various healthcare facilities in Vietnam between October 2021 and November 2021. Data were collected using a 3-part self-administered questionnaire, which covered demographics, sleep quality, and factors related to poor sleep. Poor sleep quality was defined as a total PSQI score of 5 or higher. Results: Participants' mean age was 33.20±6.81 years (range, 20.0-61.0), and 63.0% were women. The median work experience was 8.54±6.30 years. Approximately 6.3% had chronic comorbidities, such as hypertension and diabetes mellitus. About 59.5% were directly responsible for patient care and treatment, while 7.1% worked in tracing and sampling. A total of 73.8% reported poor sleep quality. Multivariate logistic regression revealed significant associations between poor sleep quality and the presence of chronic comorbidities (odds ratio [OR], 2.34; 95% confidence interval [CI], 1.17 to 5.24), being a frontline HCW directly involved in patient care and treatment (OR, 1.59; 95% CI, 1.16 to 2.16), increased working hours (OR, 1.84; 95% CI,1.37 to 2.48), and a higher frequency of encountering critically ill and dying patients (OR, 1.42; 95% CI, 1.03 to 1.95). Conclusions: The high prevalence of poor sleep among HCWs in Vietnam during the COVID-19 pandemic was similar to that in other countries. Working conditions should be adjusted to improve sleep quality among this population.

A study of the Nursing Service Quality and Satisfaction that Admitted Patients Perceived - being used SERVQUAL - (입원환자들이 지각하는 간호서비스 질과 만족에 관한 연구 - SERVQUAL을 중심으로 -)

  • 이미애
    • Journal of Korean Academy of Nursing
    • /
    • v.32 no.4
    • /
    • pp.506-518
    • /
    • 2002
  • This study was performed to measure the nursing service quality being used SERVQUAL model and satisfaction that the admitted patients perceived. Method: The questionnaire founded on the SERVQUAL was developed and distributed to 300 patients at the three general hospitals in three provincial city, Korea. For data analysis, Cronbach's α, frequencies, percentages, paired t-test, Pearson Correlation Coefficient were used. Result: In expectation, patients most highly perceived the assurance factor that was one among the 5 factors being constituted nursing service. In performance, patients most highly perceived the responsiveness factor. The performance degrees of the 5 factors and 20 attributes being constituted nursing service did not exceed the expectation degree of those. So the calculated figures for nursing service quality of the three subjected hospitals were all minus. In relation of the patients' demographics and nursing service characteristics to their general satisfaction, patients' sex, age, income and the all factors and attributes of nursing service had relation to their general satisfaction. Conclusion: It could be concluded that the nursing service quality of the three subjected hospitals was poor and the patients' demographic and nursing service characteristics had relation to their general satisfaction.

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

Determinants affecting patients loyalty in medical service: An empirical study on comparison with in-patients and out-patients using multi-group structural equation model (대학병원환자의 의료서비스 충성도에 영향을 미치는 요인에 관한 연구: 멀티그룹 공분산구조분석을 이용한 입원환자와 외래환자의 인식차이 비교분석)

  • Lee, Sang-Chul;Kim, Yang-Kyun;Chang, Sung-Gu;Han, Sang-Suk
    • Korea Journal of Hospital Management
    • /
    • v.13 no.4
    • /
    • pp.76-100
    • /
    • 2008
  • The purpose of this research is to identify causalities among service quality, service value, customer satisfaction and customer loyalty and to compare the causalities between in-patients and out-patients. A multi-group structural equation model was used to test the hypothesis of conceptual model. Empirical results indicate that two factors such as assurance and empathy have direct impact on service value and customer satisfaction in both the patients. In the results of multi-group comparison test, however, the path coefficients from service value to customer loyalty and from customer satisfaction to customer loyalty were different across the two groups. In out-patients, customer loyalty is more positively related with service value. In in-patients, customer loyalty is more positively related with customer satisfaction. It is proven that service quality influences customer loyalty. Therefore To compete successfully in today's volatile & competitive medical markets, the hospital needs to manage the service quality, considering the type of patients.

  • PDF

Developing Innovation Index of Hospital Service Using 6 Sigma and SERVQUAL (6 시그마와 SERVQUAL을 활용한 병원서비스 혁신지표 개발)

  • Oh, Ka-Eun;Bak, Won-Sook;Han, Sang-Sook;Park, Sang-Chan;Lee, Sang-Chul
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.4
    • /
    • pp.555-566
    • /
    • 2013
  • Purpose: The purpose of this study is to develop innovation index of hospital service integrating 6 sigma and SERVQUAL. Methods: This study used DMA(Define, Measure and Analysis) from 6 sigma and 5 Factors from SEVQUAL. To test data, chi-squire text, association analysis and behavior analysis was conducted. Results: This study indicated the management index through CTQ (Critical to Quality) and Chosen few X using 6 sigma process. Finally, And this study developed 5 Factors; Equipment Utilization in Tangibility, Ratio of Patients/Disease/Behavior/Treatment in Reliability, Survival RAte, Canselation Rate of Reservation, Churn Rate, Interval of Treatment and Confidence in Responsiveness, Frequency of Patients/Disease/Behavior/Treatment in Assurance and Contrast to Best Department/Best Doctor/Best Doctor in Faculty/Average of Mine in Empathy. Conclusion: This study developed innovation index of hospital service. Managing this index, hospital is able to achieve the decline of total treatment cycle, adjustment of patients behavior and increase of equipment utilization. Ultimately, hospital is able to accomplish innovation of healthcare service.

Development of Evaluation Indicators for Integrated Home Care (통합가정방문급여 평가지표 개발)

  • Park, Jong Duk;Jung, Dukyoo
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.5
    • /
    • pp.543-552
    • /
    • 2014
  • Purpose: The purpose of this study was to develop integrated evaluation indicators of home care services in the hope that the increasing group of long-term home care patients could receive quality care services. Methods: The development involves a methodological study on a development phase and a verification phase. The main survey at a verification stage was conducted by the staffs at 146 institutions who agreed to participate on this study. Results: The evaluation index for the integrated home visit care consisted of five categories and 57 indicators including Managing Institution (12), Environment and Safety (3), Right and Responsibility (7), Process of Care (31) and Results of Care (4). The criterion-related validity was verified in regard to the participation in the 2010 evaluation of long-term home-care institutions by the National Health Insurance Corporation. Conclusion: The evaluation index of the integrated home visiting care developed in this study is considered suitable to utilize as evaluating indicators in managing and evaluating the way of how institutions integrate and provide home visit care services as well as home nursing care services.

Evaluation of the Modulation Transfer Function for Computed Tomography by Using American Association Physics Medicine Phantom (컴퓨터단층검사에서 AAPM Phantom을 이용한 변조전달함수 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.193-198
    • /
    • 2016
  • In clinical computed tomography (CT), regular quality assurance (QA) has been required. This study is to evaluate the MTF for analyzing the spatial resolution using AAPM phantom in CT exam. The dual source somatom definition flash (siemens healthcare, forchheim, Germany), the brilliance 64 (philips medical system Netherlands) and aquilion 64 (toshiba medical system, Japan) were used in this study. The quantitative evaluation was performed using the image J (wayne rasband national institutes of health, USA) and chart method which is measurement of modulation transfer function (MTF). In MTF evaluation, the spatial frequencies corresponding to the 50% MTF for the CT systems were 0.58, 0.28, and $0.59mm^{-1}$, respectively and the 10% MTF for the CT systems were 1.63, 0.89, and $1.21mm^{-1}$, respectively. This study could evaluate the characteristic of spatial resolution of MTF using chart method, suggesting the quantitative evaluation method using the data.

A Study of the Perception Gap on Nursing Service between Consumers and Providers (간호서비스 질에 대한 소비자와 제공자의 지각차이에 관한 분석)

  • 이미애
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.5
    • /
    • pp.871-884
    • /
    • 2001
  • this study was to investigate the perception gap on nursing service between consumers and providers. Method: the questionnaire founded on the SERVQUAL was developed and distributed to 300 patients and 210 nurses at the three subjected general hospitals in three provincial city, Korea during February to March, 2001. For data analysis, Cronbachs' Alpha, frequency, t-test, and paired t-test were used. Result: 1. In the gap analysis on the 20 properties constituting nursing service, providers almost all perceived higher than consumer in quality. Among them, the number of properties being statistically significant was 7 in the expectation, 18 in the important and 7 in the performance. 2. In the comparison analysis of the perception gap on the expectation-performance and the important-performance, it turned out that the subjected hospitals had to improve their equipment and facilities immediately. It was suggested a good strategy to strengthen the responsiveness factor and the assurance factor of nursing service. Conclusion: it could be concluded that nurses have to recognize the blind spot of their perception and endeavor to take away the perception gap between consumers and providers.

  • PDF