• Title/Summary/Keyword: Healthcare System

Search Result 2,181, Processing Time 0.023 seconds

Development of the Model for Total Quality Management and Cost of Quality using Activity Based Costing in the Hospital (병원의 활동기준원가를 이용한 총체적 질관리 모형 및 질비용 산출 모형 개발)

  • 조우현;전기홍;이해종;박은철;김병조;김보경;이상규
    • Health Policy and Management
    • /
    • v.11 no.2
    • /
    • pp.141-168
    • /
    • 2001
  • Healthcare service organizations can apply the cost of quality(COQ) model as a method to evaluate a service quality improvement project such as Total Quality Management (TQM). COQ model has been used to quantify and evaluate the efficiency and effectiveness of TQM project through estimation between cost and benefit in intervention for a quality Improvement to provide satisfied services for a customer, and to identify a non value added process. For estimating cost of quality, We used activities and activity costs based on Activity Based Costing(ABC) system. These procedures let the researchers know whether the process is value-added by each activity, and identify a process to require improvement in TQM project. Through the series of procedures, health care organizations are service organizations can identify a problem in their quality improvement programs, solve the problem, and improve their quality of care for their costumers with optimized cost. The study subject was a quality improvement program of the department of radiology department in a hospital with n bed sizes in Metropolitan Statistical Area (MSA). The principal source of data for developing the COQ model was total cases of retaking shots for diagnoses during five months period from December of the 1998 to April of the 1999 in the department. First of the procedures, for estimating activity based cost of the department of diagnostic radiology, the researchers analyzed total department health insurance claims to identify activities and activity costs using one year period health insurance claims from September of the 1998 to August of the 1999. COQ model in this study applied Simpson & Multher's COQ(SM's COQ) model, and SM's COQ model divided cost of quality into failure cost with external and internal failure cost, and evaluation/prevention cost. The researchers identified contents for cost of quality, defined activities and activity costs for each content with the SM's COQ model, and finally made the formula for estimating activity costs relating to implementing service quality improvement program. The results from the formula for estimating cost of quality were following: 1. The reasons for retaking shots were largely classified into technique, appliances, patients, quality management, non-appliances, doctors, and unclassified. These classifications by reasons were allocated into each office doing re-taking shots. Therefore, total retaking shots categorized by reasons and offices, the researchers identified internal and external failure costs based on these categories. 2. The researchers have developed cost of quality (COQ) model, identified activities by content for cost of quality, assessed activity driving factors and activity contribution rate, and calculated total cost by each content for cost for quality, except for activity cost. 3. According to estimation of cost of quality for retaking shots in department of diagnostic radiology, the failure cost was ₩35,880, evaluation/preventive cost was ₩72,521, two times as much as failure cost. The proportion between internal failure cost and external failure cost in failure cost is similar. The study cannot identify trends on input cost and quality improving in cost of qualify over the time, because the study employs cross-sectional design. Even with this limitation, results of this study are much meaningful. This study shows possibility to evaluate value on the process of TQM subjects using activities and activity costs by ABC system, and this study can objectively evaluate quality improvement program through quantitative comparing input costs with marginal benefits in quality improvement.

  • PDF

Neurotechnologies and civil law issues (뇌신경과학 연구 및 기술에 대한 민사법적 대응)

  • SooJeong Kim
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.2
    • /
    • pp.147-196
    • /
    • 2023
  • Advances in brain science have made it possible to stimulate the brain to treat brain disorder or to connect directly between the neuron activity and an external devices. Non-invasive neurotechnologies already exist, but invasive neurotechnologies can provide more precise stimulation or measure brainwaves more precisely. Nowadays deep brain stimulation (DBS) is recognized as an accepted treatment for Parkinson's disease and essential tremor. In addition DBS has shown a certain positive effect in patients with Alzheimer's disease and depression. Brain-computer interfaces (BCI) are in the clinical stage but help patients in vegetative state can communicate or support rehabilitation for nerve-damaged people. The issue is that the people who need these invasive neurotechnologies are those whose capacity to consent is impaired or who are unable to communicate due to disease or nerve damage, while DBS and BCI operations are highly invasive and require informed consent of patients. Especially in areas where neurotechnology is still in clinical trials, the risks are greater and the benefits are uncertain, so more explanation should be provided to let patients make an informed decision. If the patient is under guardianship, the guardian is able to substitute for the patient's consent, if necessary with the authorization of court. If the patient is not under guardianship and the patient's capacity to consent is impaired or he is unable to express the consent, korean healthcare institution tend to rely on the patient's near relative guardian(de facto guardian) to give consent. But the concept of a de facto guardian is not provided by our civil law system. In the long run, it would be more appropriate to provide that a patient's spouse or next of kin may be authorized to give consent for the patient, if he or she is neither under guardianship nor appointed enduring power of attorney. If the patient was not properly informed of the risks involved in the neurosurgery, he or she may be entitled to compensation of intangible damages. If there is a causal relation between the malpractice and the side effects, the patient may also be able to recover damages for those side effects. In addition, both BCI and DBS involve the implantation of electrodes or microchips in the brain, which are controlled by an external devices. Since implantable medical devices are subject to product liability laws, the patient may be able to sue the manufacturer for damages if the defect caused the adverse effects. Recently, Korea's medical device regulation mandated liability insurance system for implantable medical devices to strengthen consumer protection.

Characteristics of Water- and Foodborne Disease's Reports in Korea National Notifiable Infectious Disease Surveillance System, 2012-2021 (2012-2021 전수감시 대상 수인성·식품매개감염병의 발생 신고 특징)

  • Jisu Won;Bryan Inho Kim;Hyungjun Kim;Jin Gwack;Hae-Sung Nam
    • Journal of agricultural medicine and community health
    • /
    • v.48 no.2
    • /
    • pp.132-143
    • /
    • 2023
  • Objectives: We aimed to describe the reporting patterns of 6 notifiable surveillance diseases in the Republic of Korea, including water- and foodborne infections, from 2012 to 2021. Methods: For the 12,296 cases that met the reporting criteria, we calculated the number of reported cases, including the number of cases confirmed by lab tests or suspected by a physician, the number of cases with delayed reporting and their average days of delay, and the median days required to report the confirmatory test results. Results: The overall number of reported cases consistently increased over the ten years, with a significant rise in the reported cases of typhoid fever, paratyphoid fever, and EHEC. Ninety-five percent of all reported cases were timely reported within one day of diagnosis. Vibrio vulnificus had the highest rate of delayed reporting (6.8% delayed over 1 day, 3.0% delayed over 3 days), while cholera had the lowest rate (1.9% delayed over 1 day, 0.1% delayed over 3 days). The average days of delayed reporting was 6.1 days: the highest for paratyphoid fever (10.8 days) and the lowest for cholera (2.7 days). For typhoid fever and paratyphoid fever, there has been an increase in the proportion of cases with negative test results. For vibrio vulnificus, there has been an increase in the proportion of cases with confirmed positive test results. As for EHEC, there has been a recent increase in cases with no confirmatory tests. Conclusions: Reported cases of water- and foodborne infectious diseases increased, indicating improved surveillance system completeness. However, for paratyphoid fever, improvements are needed in terms of timely notification by healthcare facilities and timely reporting of confirmatory test results.

Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer (조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성)

  • Jeon, Jae-Hwan;Kim, Byeong-Jin;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.145-149
    • /
    • 2010
  • Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.

  • PDF

Clinical Usefulness of Thyrotropin Binding Inhibitor Immunoglobulin (TBII) Assay by the Comparative Method (측정법에 따른 갑상선자극호르몬 결합억제면역글로블린(TBII)의 임상적 유용성 검토)

  • Park, Hee-Won;Shin, Hee-Jung;Kim, Tae-Hoon;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.175-180
    • /
    • 2009
  • Purpose: Detection of TSH-binding inhibitor immunoglobulin (TBII) in patients with hyperthyroidism is an important result of Graves' disease (GD) and hyperthyroidism treatment. This has been made out an inspection by commercial radio-receptor assays. To increase the sensitivity and the specificity of the assay, many results of the assay were reported. In this study we evaluated the clinical usetulness of TBII assays by the Comparative method. Material and Methods: We were measured by using healthy control group (n=30, male=20, female=10) of Seoul National University Hospital Healthcare System Gangnam Center from January to March in 2009. Similarly, We were measured by using hyperthyroid (TSH<$0.05\;{\mu}IU/mL$, FT4>1.80 ng/dL) experimental group (n=58, male=14, female=44) of division of endocrinology and metabolism department of internal medicine Seoul National University Hospital from January to March in 2009. We made a comparative study of each two assays from the first generation to the third generation. We were used of TSAb assay as a measurement of GD diagnostic technique. Results: The specificity of healthy control group was 100% according to the generation. (Specificity=100%, n=30) The sensitivity of hyperthyroid experimental group were the first generation RSR<%> (79.3%, n=58), RSR (51.7%, n=58), the second generation RSR-CT (93.1%, n=58), BRAHMSCT (98.3%, n=58), the third generation ELISA (94.6%, n=56), ECLIA (97.7%, n=58) and TS-Ab<%> (93.5%, n=46). Conclusion: We were used of TSAb assay as a measurement of GD diagnostic technique, The result of data showed a high correlation between the third generation TBII assay and the second generation TBII assay ($R^2$=0.923). Instead of the first generation assay, the second generation assay can be more useful in clincal diagnosis.

  • PDF

Quantitative Analysis of Brain Metabolite Spectrum Depending on the Concentration of the Contrast Media in Phantom (팬텀 내 조영제 농도에 따른 뇌 대사물질 Spectrum의 정량분석)

  • Shin, WoonJae;Gang, EunBo;Chun, SongI
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 2015
  • Quantitative analysis of MR spectrum depending on mole concentration of the contrast media in cereberal metabolite phantom was performed. PRESS pulse sequence was used to obtain MR spectrum at 3.0T MRI system (Archieva, Philips Healthcare, Best, Netherland), and the phantom contains brain metabolites such as N-Acetyl Asparatate (NAA), Choline (Cho), Creatine (Cr) and Lactate (Lac). In this study, optimization of MRS PRESS pulse sequency depending on the concentration of contrast media (0, 0.1 and $0.3mmol/{\ell}$) was evaluated for various repetition time(TR; 1500, 1700 and 2000 ms). In control (cotrast-media-free) group, NAA and Cho signals were the highest at TR 2000 ms than at 1700 and 1500 ms. Cr had the highest peak signal at TR 1500 ms. When concentration of contrast media was $0.1mmol/{\ell}$, the metabolites were increased NAA 73%, Cho 249%, Cr 37% at TR 1700 ms compared with other TR, and also signal increased at $0.3mmol/{\ell}$, In $0.5mmol/{\ell}$ of contrast agent, cerebral metabolite peaks reduced, especially when TR 1500 ms and 2000 ms they decreased below those of control group. The ratio of metabolite peaks such as NAA/Cr and Cho/Cr decreased as the concentration of the contrast agent increased from 0.1 to $0.5mmol/{\ell}$. Authors found that the optimization of PRESS sequence for 0.3T MRS was as follows: low density of contrast agent ($0.1mmol/{\ell}$ and $0.3mmol/{\ell}$) made the highest signal intensity, while high density of contrast agent reveals the least reduction of signal intensity at 1700 ms. In conclusion, authors believe that it is helpful to reduce TR for acquiring maximum signal intensity.

Study on the Education Curriculum and Clinical Practice of Medical Technologists (임상병리사 교육과정 및 임상실습에 대한 연구)

  • Yang, Byoung-Seon;Choi, Se-Mook;Shim, Moon-Jung;Kim, Chung-Hwan;Bae, Hyung-Joon;Yook, Keun-Dol;Kim, Yoon-Sik;Lim, Yong;Kang, Ji-Hyuk;Kim, Hong-Sung;Kim, Dong-Chan;Shin, Gyeonghee;Lee, Sang-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.320-330
    • /
    • 2018
  • This study analyzed the curriculum and clinical practicum of the department of clinical laboratory science in Korea. The 2017 educational curricula of all 3-year and 4-year universities were analyzed. Clinical practice was conducted by a questionnaire. As a result of curriculum analysis, the 3-year curriculum was able to grasp the curriculum that focused on the national examinations of medical technologists, and the 4-year curriculum was open to a variety of subjects reflecting the changes in the future, but only at a few universities. In addition, the autonomous enrollment application made it possible to take a national examination without enrolling in courses that students find difficult in major courses. In the case of clinical practice, it was difficult to standardize in various practical institutes, practice periods, and practice credits. Therefore, it will be necessary to standardize the composition of the credits according to the duration of clinical practice and the duration of education. Moreover, is necessary to revise the curriculum in consideration of medical technologist job analysis and clinical field, and it will be necessary to standardize the curriculum and clinical practice model through the Medical Technologist Evaluation Center.

Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy (Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리)

  • Shim, Su-Jung;Shim, Jang-Bo;Lee, Sang-Hoon;Min, Chul-Kee;Cho, Kwang-Hwan;Shin, Dong-Oh;Choi, Jin-Ho;Park, Sung-Ill;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.33-41
    • /
    • 2012
  • For applying the quality assurance (QA) of volumetric modulated arc therapy (VMAT) introduced in Eulji Hospital, we classify it into three different QA steps, treatment planning QA, pretreatment delivering QA, and treatment verifying QA. These steps are based on the existing intensity modulated radiation therapy (IMRT) QA that is currently used in our hospital. In each QA step, the evaluated items that are from QA program are configured and documented. In this study, QA program is not only applied to actual patient treatment, but also evaluated to establish a reference of clinical acceptance in pretreatment delivering QA. As a result, the confidence limits (CLs) in the measurements for the high-dose and low-dose regions are similar to the conventional IMRT level, and the clinical acceptance references in our hospital are determined to be 3 to 5% for the high-dose and the low-dose regions, respectively. Due to the characteristics of VMAT, evaluation of the intensity map was carried out using an ArcCheck device that was able to measure the intensity map in all directions, $360^{\circ}$. With a couple of dosimetric devices, the gamma index was evaluated and analyzed. The results were similar to the result of individual intensity maps in IMRT. Mapcheck, which is a 2-dimensional (2D) array device, was used to display the isodose distributions and gave very excellent local CL results. Thus, in our hospital, the acceptance references used in practical clinical application for the intensity maps of $360^{\circ}$ directions and the coronal isodose distributions were determined to be 93% and 95%, respectively. To reduce arbitrary uncertainties and system errors, we had to evaluate the local CLs by using a phantom and to cooperate with multiple organizations to participate in this evaluation. In addition, we had to evaluate the local CLs by dividing them into different sections about the patient treatment points in practical clinics.

A study on Establishment and Management of the CCTV in Operating Room (수술실 CCTV 설치 및 운영에 대한 고찰)

  • Kim, Minji
    • The Korean Society of Law and Medicine
    • /
    • v.20 no.1
    • /
    • pp.109-132
    • /
    • 2019
  • Recently, medical accidents related to surgical procedures have increased. In addition, the media reported that some of these accidents were involved in health crimes. Patient-advocate groups have called for mandatory establishment and management of CCTV in operating rooms. There is a lot of discussion among the interested parties, so it is necessary to review the relevant laws and regulations. The purpose of this study is to identify the characteristics of CCTV in operating rooms and to review legislations related to establishment and management of the CCTV in operating rooms. Medical institutions use CCTV for management of facilities and patient safety and install it in operating rooms optionally. The Constitution guarantees the privacy and the privacy of correspondence of every citizen, but it can be limited by the law for public welfare. Currently, however, there is no existing law about establishment and management of the CCTV in operating rooms and it can be defect of legal system. Under the current legislations, it is likely that the Self-determination can be violated due to the characteristic of healthcare provider when CCTV is mandatorily installed in operating room. In addition, the regulations on access and leakage of confidential information known by operator are insufficient. So that, the safety of the visual data might be threatened. Furthermore, unless the period and the place of storage of the visual data are clearly defined, it is highly unlikely to meet the original purpose of patient safety and prevention of medical accidents. This study is meaningful as there is few previous study on this topic although the need for legal review about this is growing and several bills are being proposed. It is expected that the results of this study can be utilized as basic data for enactment or amendment of the laws and regulations about establishment and management of CCTV in operating rooms.

A Study on the Improvement for Medical Service Using Video Promotion Materials for PET/CT Scans (PET/CT 검사에서 동영상 홍보물을 통한 의료서비스 향상에 관한 연구)

  • Kim, Woo Hyun;Kim, Jung Seon;Ko, Hyun Soo;Sung, Ji Hye;Lee, Jeoung Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Purpose: One of the current services, providing information to the patients and their guardians by using promotion materials induces positive responses and contributes to the improvement of the hospital reliability. Therefore, the objective of this study is to evaluate the effectiveness of audio visual materials, one of the means of promotion, as a way to give accurate medical information to resolve patient's curiosity about purpose and procedure of their examination and deplete complains about waiting which attributes negative effect to service quality assessment. Materials and Methods: 60 patients(mean age $53.97{\pm}12.24$, male : female = 26 : 34) who had $^{18}F-FDG PET/CT$ scan from July 2012 to August 2012 in Seoul Asan Medical Center were referred to the study. All of the patients having PET/CT scan were asked to watch an informative video material before the injection of radiopharmaceutical ($^{18}F-FDG$) and to fill in a questionnaire. Results: As a result of analyzing the contents of questionnaire, 52% of 60 patients had PET/CT scan for the first time and 72.4% of the patients read the PET/CT guidebook offered from their outpatient department or inpatient wards before their scan. After we searched the level of previous knowledge of the purpose and method of PET/CT scan, the patients answered 25.1% "know well", 34% "not sure", 40.9% "don't know" respectively. And 84.7% of the patients answered that watching the PET/CT guide video before the injection helps understanding what exam they were having and 15.3% of the patients did not. For the question asking ever the patients have experienced using our homepage or smart phone QR code to see the guide video before they visit out PET center, only 3.3% of them answered "yes". Lastly, the patients answered 60.1% "yes", 31.4% "so so" and 8.5% "no" respectively for the question asking whether watching the video makes the patients to fill the waiting time short. Conclusion: It is found that understanding of objective and method of the PET/CT scan and level of satisfaction was improved after the patients watched the guide video whether they had PET/CT scan before and read the PET/CT guidebook or not. Also, watching the video was effective for the reduction of perceptible waiting time. But while displaying the PET/CT guide video is useful for providing information about the scan and shortening the waiting time as one of the medical service, utilization of service was actually very poor because of the passive promotion and indifference of the patients about their examination. Therefore, from now on, it is necessary to construct the healthcare system which can be offered to more patients through the active promotion.

  • PDF