• Title/Summary/Keyword: Health technology assessment

Search Result 825, Processing Time 0.021 seconds

Accuracy of the 24-hour diet recall method to determine energy intake in elderly women compared with the doubly labeled water method (에너지 섭취 조사를 위한 24시간 회상법의 정확도 평가: 여자노인을 대상으로 이중표식수법을 이용하여)

  • Park, Kye-Wol;Go, Na-Young;Jeon, Ji-Hye;Ndahimana, Didace;Ishikawa-Takata, Kazuko;Park, Jonghoon;Kim, Eun-Kyung
    • Journal of Nutrition and Health
    • /
    • v.53 no.5
    • /
    • pp.476-487
    • /
    • 2020
  • Purpose: This study evaluated the accuracy of the 24-hour diet recall method for estimating energy intakes in elderly women using the doubly labeled water (DLW) method. Methods: The subjects were 23 elderly women with a mean age of 70.3 ± 3.3 years and body mass index (BMI) of 23.9 ± 2.8 kg/㎡. The total energy expenditure (TEEDLW) was determined by using the DLW and used to validate the 24-hour diet recall method. The total energy intake (TEI) was calculated from the 24-hour diet recall method for three days. Results: TEI (1,489.6 ± 211.1 kcal/day) was significantly lower than TEEDLW (2,023.5 ± 234.9 kcal/day) and was largely under-reported by -533.9 ± 228.0 kcal/day (-25.9%). The accurate prediction rate of elderly women in this study was 8.7%. The Bland-Altman plot, which was used to evaluate the TEI and the TEEDLW, showed that the agreement between them was negatively skewed, ranging from -980.8 kcal/day to -86.9 kcal/day. Conclusion: This study showed that the energy intake of elderly women was underreported. Strategies to increase the accuracy of the 24-hour diet recall methods in the elderly women should be studied through analysis of factors that affect underreporting rate. Further studies will be needed to assess the validity of the 24-hour diet recall method in other population groups.

The Effect of Some Amendments to Reduce Ammonia during Pig Manure Composting (몇 가지 처리제의 첨가에 의한 돈분의 퇴비화 과정 중 암모니아 발생 저감 효과)

  • Joo, Jin-Ho;Kim, Dae-Hoon;Yoo, Jae-Hong;Ok, Yong-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.4
    • /
    • pp.269-273
    • /
    • 2007
  • Occurrence of malodor could cause adverse impacts on human health and increase public interest. Therefore, scientific methods to decrease odor is required. Endeavor to decrease odor from compost however has not fully been successful. The purpose of this research is assessment of some amendments to reduce $NH_3$ from immature composts. Calcium hydroxide was applied to composts due to it's characteristics to increase pH. Activated carbon and zerovalent iron (ZVI) were selected because of their adsorption properties. The research results were as follows: Calcium hydroxide, activated carbon, zerovalent iron increased the composting temperature above $60^{\circ}C$. The addition of calcium hydroxide, activated carbon, and ZVI to compastry process increased pH 8.6 - 8.8 from $1^{st}$ day to $14^{th}$ day. During the 14 days of composting, addition of calcium hydroxide, activated carbon and ZVI changed EC from $2.15-0.66dS\;m^{-1}$, $1.48-1.11dS\;m^{-1}$, respectively and $1.77-0.68dS\;m^{-1}$. The difference in EC of the compost was due to irregularities of samples. Organic matter in the compost decreased through out theexcept control. The $NH_4-N/NO_3-N$ ratio of all experimental compost increased through the process. The addition of activated carbon, calcium hydroxide and ZVI decreased $NH_3$ from 0.1ppm, 0.7ppm and 1.7ppm more than the control (pig manure and sawdust), 9.3ppm, in 30 days of composting. In conclusion, odor from prematured compost decreased by addition of chemicals like calcium hydroxide, activated carbon, zerovalent iron. Moreover, use of these $NH_3$ reducers alone or together combined at different periods of composting etc. could decrease $NH_3$.

Vitamin B5 and B6 Contents in Fresh Materials and after Parboiling Treatment in Harvested Vegetables (채소류의 수확 후 원재료 및 데침 처리에 의한 비타민 B5 및 B6 함량 변화)

  • Kim, Gi-Ppeum;Ahn, Kyung-Geun;Kim, Gyeong-Ha;Hwang, Young-Sun;Kang, In-Kyu;Choi, Youngmin;Kim, Haeng-Ran;Choung, Myoung-Gun
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.172-182
    • /
    • 2016
  • This study was aimed to determine the changes in vitamin $B_5$ and $B_6$ contents compared to fresh materials after parboiling treatment of the main vegetables consumed in Korea. The specificity of accuracy and precision for vitamin $B_5$ and $B_6$ analysis method were validated using high-performance liquid chromatography (HPLC). The recovery rate of standard reference material (SRM) was excellent, and all analysis was under the control line based on the quality control chart for vitamin $B_5$ and $B_6$. The Z-score for vitamin $B_6$ in food analysis performance assessment scheme (FAPAS) proficiency test was -1.0, confirming reliability of analytical performance. The vitamin $B_5$ and $B_6$ contents in a total of 39 fresh materials and parboiled samples were analyzed. The contents of vitamin $B_5$ and $B_6$ ranged from 0.000 to 2.462 and from 0.000 to $0.127mg{\cdot}100g^{-1}$, respectively. The highest contents of vitamin $B_5$ and $B_6$ were $2.462mg{\cdot}100g^{-1}$ in fresh fatsia shoots (stem vegetables), and $0.127mg{\cdot}100g^{-1}$ in fresh spinach beet (leafy vegetables), respectively. Moreover, the vitamin $B_5$ and $B_6$ contents for parboiling treatment in most vegetables were reduced or not detected. In particular, the contents of vitamin $B_5$ in parboiled fatsia shoots and vitamin $B_6$ in parboiled yellow potato and spinach beet were decreased 20- and 4-fold compared with fresh material, respectively. These results can be used as important basic data for utilization and processing of various vegetable crops, information for dietary life, management of school meals, and national health for Koreans.

Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy (항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석)

  • Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF