• Title/Summary/Keyword: Health monitor

Search Result 951, Processing Time 0.027 seconds

Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station (인천광역시 지하철 역사 내 지하수 및 수돗물의 라돈 위해성 검토)

  • Lee, Yoo-Sang;Lee, Sang-Bok;Kang, Min-Seok;Jeong, Dong-Ha;Kim, Jin-Hong;Oh, Yoon-Sik;Choi, Se-Rin;Park, Jeong-Soo;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

The UGT1A9*22 genotype identifies a high-risk group for irinotecan toxicity among gastric cancer patients

  • Lee, Choong-kun;Chon, Hong Jae;Kwon, Woo Sun;Ban, Hyo-Jeong;Kim, Sang Cheol;Kim, Hyunwook;Jeung, Hei-Cheul;Chung, Jimyung;Rha, Sun Young
    • Genomics & Informatics
    • /
    • v.20 no.3
    • /
    • pp.29.1-29.12
    • /
    • 2022
  • Several studies have shown associations between irinotecan toxicity and UGT1A genetic variations in colorectal and lung cancer, but only limited data are available for gastric cancer patients. We evaluated the frequencies of UGT1A polymorphisms and their relationship with clinicopathologic parameters in 382 Korean gastric cancer patients. Polymorphisms of UGT1A1*6, UGT1A1*27, UGT1A1*28, UGT1A1*60, UGT1A7*2, UGT1A7*3, and UGT1A9*22 were genotyped by direct sequencing. In 98 patients treated with irinotecan-containing regimens, toxicity and response were compared according to the genotype. The UGT1A1*6 and UGT1A9*22 genotypes showed a higher prevalence in Korean gastric cancer patients, while the prevalence of the UG1A1*28 polymorphism was lower than in normal Koreans, as has been found in other studies of Asian populations. The incidence of severe diarrhea after irinotecan-containing treatment was more common in patients with the UGT1A1*6, UGT1A7*3 and UGT1A9*22 polymorphisms than in controls. The presence of the UGT1A1*6 allele also showed a significant association with grade III-IV neutropenia. Upon haplotype and diplotype analyses, almost every patient bearing the UGT1A1*6 or UGT1A7*3 variant also had the UGT1A9*22 polymorphism, and all severe manifestations of UGT1A polymorphism-associated toxicity were related to the UGT1A9*22 polymorphism. By genotyping UGT1A9*22 polymorphisms, we could identify high-risk gastric cancer patients receiving irinotecan-containing chemotherapy, who would experience severe toxicity. When treating high-risk patients with the UGT1A9*22 polymorphism, clinicians should closely monitor them for signs of toxicity such as severe diarrhea or neutropenia.

Changes in the Health Life of the Elderly Through the Handle Height of Walking Assistant Vehicle Article : Emphasizing on State Anxiety, Heart Rate and Fall Efficacy (보행보조차 손잡이 높이에 따른 노인들의 건강생활의 변화 : 상태불안과 심박수, 낙상효능감을 중심으로)

  • Son, Sung-Min;Kwag, Sung-Won
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.519-528
    • /
    • 2020
  • Purpose of this study is to analyze the changes in state anxiety, heart rate, and fall efficacy of the elderly through the handle height of walking assistant vehicle (WAV). The subjects were 32 elderlies. WAV was in the form of strollers, and it's handle height was set as 48% of a subject's total height. Also, it's height was divided into 48, 43, 38%. To measure the state anxiety, Korean State-Trait Anxiety Inventory was used and to measure the heart rate, Fitbit Charge 2 wrist heart rate monitor was used. To measure the fall efficacy, Fall Efficacy Scale-Korea was used. As the results of state anxiety and heart rate, the statistically significant increase showed continuously through the decrease of the handle height of WAV. As the results of fall efficacy, the statistically significant decrease showed continuously through the decrease of the handle height of WAV. In all of the post hoc test, the results of the state anxiety and fall efficacy showed significant difference among the each handle height of WAV and the results of the heart rate showed significant difference between the 48, 43% and 38% handle height of WAV. Thus, to decrease the state anxiety and heart rate and increase the fall efficacy of the elderly, the handle height of WAV should be properly positioned and considered to adjust to 48% of the user's total height.

Wearable oxygen saturation measurement platform for worker safety management (작업자의 안전관리를 위한 웨어러블 산소포화도 측정 플랫폼)

  • Lee, Yun Ju;Song, Chai Jong;Yoo, Sun Kook
    • Smart Media Journal
    • /
    • v.11 no.9
    • /
    • pp.30-38
    • /
    • 2022
  • It is important to grasp biometric data in real time for prompt action in the event of a safety accident at a work site where the risk of safety accidents exists. Among them, blood oxygen saturation is the most important factor in maintaining human life, so real-time oxygen saturation measurement and monitoring is necessary according to the situation as a preemptive response for worker safety management. By receiving real-time bio-signals from workers wearing health and life-risk protective clothing, and sharing and analyzing the worker's risk status in an external system, it is possible to diagnose the worker's current condition and efficiently respond to emergencies that may occur to the worker. In this paper, we propose a wearable oxygen saturation measurement platform technology that can monitor the risk of harmful gases and oxygen saturation of the wearer in real time and ensure the wearer's activity and safety in order to cope with emergency situations at the scene of an accident. If we overcome the limitations identified through the results of the proposed system later and apply improved biodata such as motion correction to the platform, we expect that it will be usable not only in hazardous gas environments, but also in hospitals and homes for emergency patients.

Dosimetric Comparison of Three-Dimensional Conformal, Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Dynamic Conformal Arc Therapy Techniques in Prophylactic Cranial Irradiation

  • Ismail Faruk Durmus;Dursun Esitmez;Guner Ipek Arslan;Ayse Okumus
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.41-47
    • /
    • 2023
  • Purpose: This study aimed to dosimetrically compare the technique of three-dimensional conformal radiotherapy (3D CRT), which is a traditional prophylactic cranial irradiation method, and the intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques used in the last few decades with the dynamic conformal arc therapy (DCAT) technique. Methods: The 3D CRT, VMAT, IMRT, and DCAT plans were prepared with 25 Gy in 10 fractions in a Monaco planning system. The target volume and the critical organ doses were compared. A comparison of the body V2, V5, and V10 doses, monitor unit (MU), and beam on-time values was also performed. Results: In planned target volume of the brain (PTVBrain), the highest D99 dose value (P<0.001) and the most homogeneous (P=0.049) dose distribution according to the heterogeneity index were obtained using the VMAT technique. In contrast, the lowest values were obtained using the 3D CRT technique in the body V2, V5, and V10 doses. The MU values were the lowest when DCAT (P=0.001) was used. These values were 0.34% (P=0.256) lower with the 3D CRT technique, 66% (P=0.001) lower with IMRT, and 72% (P=0.001) lower with VMAT. The beam on-time values were the lowest with the 3D CRT planning (P<0.001), 3.8% (P=0.008) lower than DCAT, 65% (P=0.001) lower than VMAT planning, and 76% (P=0.001) lower than IMRT planning. Conclusions: Without sacrificing the homogeneous dose distribution and the critical organ doses in IMRTs, three to four times less treatment time, less low-dose volume, less leakage radiation, and less radiation scattering could be achieved when the DCAT technique is used similar to conventional methods. In short, DCAT, which is applicable in small target volumes, can also be successfully planned in large target volumes, such as the whole-brain.

Fabrication and Characterization of Lactate Oxidase-catalase-mitochondria Electrode (젖산 산화효소-카탈라아제-미토콘드리아 전극 제작 및 특성 분석)

  • Ke Shi;Keerthi Booshan Manikandan;Young-Bong Choi;Chang-Joon Kim
    • Korean Chemical Engineering Research
    • /
    • v.62 no.3
    • /
    • pp.238-245
    • /
    • 2024
  • The lactate electrode can be utilized either as an electrode for lactate sensor to monitor the patient's health status, stress level, and athlete's fatigue in real time or lactate fuel cell. In this study, we fabricated a high-performance electrode composed of lactate oxidase, catalase, and mitochondria, and investigated the surface analysis and electrochemical properties of this electrode. Carbon paper modified with single-walled carbon nanotubes (CP-SWCNT) had significantly improved electrical conductivity compared to before modification. The electrode to which lactate oxidase, catalase, and mitochondria were attached (CP-SWCNT-LOx-Cat-Mito) produced a higher current than the electrode to which lactate oxidase and catalase were attached. The amount of reduction current produced by the bilirubin oxidase (BOD)-attached electrode (CP-SWCNT-BOD) was greatly affected by the presence or absence of oxygen in the electrolyte. The fuel cell composed of CP-SWCNT-LOx-Cat-Mito (anode) and CP-SWCNT-BOD (cathode) produced maximum power (29 ㎼/cm2) at a discharge current density of 133 ㎂/cm2. From this study, we had proved that mitochondria is essential for improving lactate sensor and fuel cell performance.

Korean Food Review Analysis Using Large Language Models: Sentiment Analysis and Multi-Labeling for Food Safety Hazard Detection (대형 언어 모델을 활용한 한국어 식품 리뷰 분석: 감성분석과 다중 라벨링을 통한 식품안전 위해 탐지 연구)

  • Eun-Seon Choi;Kyung-Hee Lee;Wan-Sup Cho
    • The Journal of Bigdata
    • /
    • v.9 no.1
    • /
    • pp.75-88
    • /
    • 2024
  • Recently, there have been cases reported in the news of individuals experiencing symptoms of food poisoning after consuming raw beef purchased from online platforms, or reviews claiming that cherry tomatoes tasted bitter. This suggests the potential for analyzing food reviews on online platforms to detect food hazards, enabling government agencies, food manufacturers, and distributors to manage consumer food safety risks. This study proposes a classification model that uses sentiment analysis and large language models to analyze food reviews and detect negative ones, multi-labeling key food safety hazards (food poisoning, spoilage, chemical odors, foreign objects). The sentiment analysis model effectively minimized the misclassification of negative reviews with a low False Positive rate using a 'funnel' model. The multi-labeling model for food safety hazards showed high performance with both recall and accuracy over 96% when using GPT-4 Turbo compared to GPT-3.5. Government agencies, food manufacturers, and distributors can use the proposed model to monitor consumer reviews in real-time, detect potential food safety issues early, and manage risks. Such a system can protect corporate brand reputation, enhance consumer protection, and ultimately improve consumer health and safety.

Dental Caries Risk Can Be Predicted by Simply Measuring the pH and Buffering Capacity of Saliva (치아우식과 연관된 타액의 pH와 완충력)

  • Jeong, Soon-Jeong;Apostolska, Sonja;Jankulovska, Mira;Angelova, Dragana;Nares, Salvador;Yoon, Mi-Sook;Lim, Do-Seon;Angelov, Nikola;Jeong, Moon-Jin
    • Journal of dental hygiene science
    • /
    • v.6 no.3
    • /
    • pp.159-162
    • /
    • 2006
  • This study examined the relationship between the quantity of Streptococcus mutans and Lactobacillus spp. related to dental caries and the degree of acidity in saliva. A total of 240 saliva samples were taken from 80 subjects at the faculty of dentistry in Skopje, Macedonia. The saliva samples were taken by stimulating saliva production stimulation with paraffin chewing. However, no stimulation was applied when obtaining the samples used for measuring the pH. The data showed that in the caries group, S. mutans in 1 ml of saliva formed colonies with confluent growth (CFU > $10^6$ and $10^4-10^5$) in 100% of samples, whereas the Lactobacillus spp. formed colonies with confluent growth in 78.3%. In contrast, no colonies with confluent growth (CFU > $10^6$ and $10^5$) were found in the control group (with healthy intact teeth). In the caries group, the pH of the saliva was slightly acidic (pH = 5.90 - 6.50) and the buffering capacity was very low (below 0.7 ml of saliva per min). On the other hand, the pH of the saliva in the control group was neutral (pH 7.01 - 7.7) and the buffering capacity was high (over 1 ml of saliva per min). The increased number of S. mutans and Lactobacillus spp. in 1 ml of saliva (above $10^5$ CFU or more) from the CRT (Caries Risk Test, Vivadent, Liechtenstein) bacteria test can indicate an increased caries risk as well as slightly higher acidity of the saliva. Overall, these results reveal that the caries risk can be predicted by simply measuring the pH and buffering capacity of saliva, and can be used to monitor the effect of dental hygiene practices with the aim of preventing dental caries.

  • PDF

The Influences of Stress Coping Strategy on Depression and Anxiety in Recipients of Hematopoietic Stem Cell Transplantation (스트레스 대처방식이 조혈모세포 이식 환자의 우울과 불안에 미치는 영향)

  • Yoon, Su-Jung;Lee, Chul;Lim, Seong-Hu;Chae, Jeong-Ho;Jun, Tae-Youn;Kim, Kwang-Soo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2002
  • Objective : Increasing in frequency and success of hematopoietic stem cell transplantation and improved survival rates have led to growing concerns regarding the psychosocial aspects of hematopoietic stem cell transplantation recipients. In this study, we have examined the stress coping strategies and related psychiatric symptom in the hematopoietic stem cell transplantation recipients. Methods : In this study, we examined the psychological stress symptoms of hematopoietic stem cell transplantation recipients and differences of psychosocial variables between active coping group and passive coping group. Twenty nine recipients of hematopoietic stem cell transplantation were recruited prospectively and assessed at 2 weeks pretranplant and at 1-2 days posttranplant. Thirty normal controls were recruited. Assessments included a psychiatric interview, a variety of standardized questionnaires (Ways of Coping Questionnaires, Perceived Stress Scale, Hospital Depression and Anxiety Scale, Short-Form 36 Health Survey). Results : Hematopoietic stem cell transplantation patients showed higher degree of depression (p<0.001) and anxiety (p=0.011) symptoms than normal control group. However, no differences of depression and anxiety symptoms between pretransplant and posttransplant status were showed. And, passive coping group showed higher degree of depression (p=0.046) and anxiety symptoms (p<0.001) than active coping group. Conclusions : Our results suggested that many hematopoietic stem cell transplantation recipients would exhibit severe to moderate symptoms of anxiety and depression. Also, it seemed likely that passive coping style might influence the development of negative affect such as anxiety and depression. The implications of these findings were discussed in terms of the need to monitor the coping strategies and apply the appropriate psychiatric intervention. And, further prospective studies about long-term survival and psychological adaptive functions of hematopoietic stem cell transplantation patients are recommended.

  • PDF

Using CR System at the Department of Radiation Oncology PACS Evaluation (방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가)

  • Hong, Seung-Il;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.143-149
    • /
    • 2012
  • Today each hospital is trend that change rapidly by up to date, digitization and introducing newest medical treatment equipment. So, we introduce new CR system and supplement film system's shortcoming and PACS, EMR, RTP system's network that is using in hospital harmoniously and accomplish quality improvement of medical treatment and service elevation about business efficiency enlargement and patient Accordingly, we wish to introduce our case that integrate reflex that happen with radiation oncology here upon to PACS using CR system and estimate the availability. We measured that is Gantry, Collimator Star Shot, Light vs. Radiation, HDR QA(Dwell position accuracy) with Medical LINAC(MEVATRON-MX) Then, PACS was implemented on the digital images on the monitor that can be confirmed through the QA. Also, for cooperation with OCS system that is using from present source and impose code that need in treatment in each treatment, did so that Order that connect to network, input to CR may appear, did so that can solve support data mistake (active Pinacle's case supports DICOM3 file from present source but PACS does not support DICOM3 files.) of Pinacle and PACS that is Planning System and look at Planning premier in PACS. All image and data constructed integration to PACS as can refer and conduct premier in Hospital anywhere using CR system. Use Dosimetry IP in Filmless environment and QA's trial such as Light/Radition field size correspondence, gantry rotation axis' accuracy, collimator rotation axis' accuracy, brachy therapy's Dwell position check is available. Business efficiency by decrease and so on of unnecessary human strength consumption was augmented accordingly with session shortening as that integrate premier that is neted with radiation oncology using CR system to PACS. and for the future patient information security is essential.