• Title/Summary/Keyword: Health monitor

Search Result 951, Processing Time 0.034 seconds

A Study on the Water Quality Characteristics of the Reservoirs in Gwangju City (광주지역 저수지수 수질특성에 관한 연구)

  • Kim, Dong-Soo;Park, Jong-Whan;Kim, Yun-Hee;Song, Hyung-Myung;Park, Jong-Tae
    • Journal of Environmental Science International
    • /
    • v.18 no.12
    • /
    • pp.1383-1390
    • /
    • 2009
  • This study was performed to investigate the physico-chemical properties and phytoplankton concentration from February to December, 2007 in Gwangju area reservoirs. Water samples from 20 reservoirs were analyze d. As results of the water quality analysis, the average pH was 7.6 and annual pH were 6.3~9.6. The higher pH of 8.6~9.6 were showed from March to August due to eutrophication. Chlorophyll-a concentration ranged from 0.4 to $164.3\;mg/m^3$. The highest chlorophyll-a concentration was observed in August. BOD was correlated with SS, T-N, and Chlorophyll-a(R=0.82, 0.90 and 0.84) respectively. COD was correlated with BOD, SS and Chlorophyll-a(R= 0.89, 0.77 and 0.76) respectively. The T-N/T-P ratios were 4~281, so phosph orus was considered to be the limiting factor in most of points. The trophic state showed eutrophicate states in Gwangju reservoirs. Therefore it was necessary to monitor continuously. In order to monitor the reservoirs, an algae prediction system must be used.

Implementation of Wireless ECG Measurement System Attaching in Chair for Ubiquitous Health Care Environment (유비쿼터스 헬스 케어 적용을 위한 의자 부착형 무선 심전도 측정 시스템 구현)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Jee-Chul;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.776-781
    • /
    • 2008
  • In this study, ubiquitous health care system attaching in chair to monitor ECG for health care was developed at the unconsciousness state. The system conveniently and simple measured ECG at non-consciousness. We measured the contact impedance to skin-electrode of metal mesh electrodes of the system. Contact impedance enable the electrode to use for ECG measurement. The results are that the impedance of the metal mesh electrodes according to sizes is low when the size is 4$cm^2$. As the result, when the size of the metal mesh electrode is 4$cm^2$, the electrode is fit for ECG measurement. We can acquired by positing the arm on the metal mesh electrode. The ECG signal was detected using a high-input-impedance bio-amplifier, and then passed filter circuitry. The measured signal transmitted to a PC through the bluetooth wireless communication and monitored. Data of the non-constrained ECG system attaching in chair is noise-data when comparing metal mesh electrode with the Ag/Agcl electrode but the data is significant to monitor ECG for check the body state.

Monitoring system of blood pressure change according to PTT based posture (PTT기반 자세에 따른 혈압변화 모니터링 시스템)

  • Kim, Mi-Seong;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.534-535
    • /
    • 2017
  • With the economic growth, the quality of life of the individual is improving and interest in health is increasing. However, it is not easy for self-care for the modern people who are busy and the elderly who are uncomfortable. The purpose of this study was to develop a healthcare system that can more easily monitor the health condition of the patients. The ECG and pulse wave including the important health information that can be conveniently measured by the general public can be measured and the PTT and to monitor the health status of the circulatory system. To evaluate the performance of the implemented system, we measured PTT according to posture change and evaluated the possibility of monitoring arterial blood flow during daily life.

  • PDF

Structural Damage Monitoring of Harbor Caissons with Interlocking Condition

  • Huynh, Thanh-Canh;Lee, So-Young;Nguyen, Khac-Duy;Kim, Jeong-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.6
    • /
    • pp.678-685
    • /
    • 2012
  • The objective of this study is to monitor the health status of harbor caissons which have potential foundation damage. To obtain the objective, the following approaches are performed. Firstly, a structural damage monitoring(SDM) method is designed for interlocked multiple-caisson structures. The SDM method utilizes the change in modal strain energy to monitor the foundation damage in a target caisson unit. Secondly, a finite element model of a caisson system which consists of three caisson units is established to verify the feasibility of the proposed method. In the finite element simulation, the caisson units are constrained each other by shear-key connections. The health status of the caisson system against various levels of foundation damage is monitored by measuring relative modal displacements between the adjacent caissons.

Structural Health Monitoring Methods using PZT-Actuated Flexural Vibration of Beams (PZT 에 의해 굽힘 가진을 받는 보의 구조건전도 모니터링)

  • Kim, Seung-Joon;Park, Jun-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.601-605
    • /
    • 2007
  • This paper describes the experimental method to monitor the structural integrity. The crack on structures changes the wave propagation characteristics of structures. To monitor this change, frequency dependent variation of dynamic stiffness of beam structures is obtained by using beam transfer function method, and its trends are compared to undamaged one for identifying the location and size of the crack. Piezoelectric actuators were used to generate flexural vibrations. It eliminated various restrictions of continuously measuring wave propagation characteristics and monitoring structural integrity. The structural integrity was identified with minimal number of measurements and smart structures employing PZT actuations.

  • PDF

Present Status and Analysis for IEEE 11073 Personal Health Device Specializations (IEEE 11073 개인건강기기별 표준 현황 및 분석)

  • Park, Han-Na;Kim, Seung-Hwan;Yoo, Done-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.469-475
    • /
    • 2012
  • Increasing interest of life expectancy and health has made the u-health industry activating and the several international standard developing organizations(SDO) are dealing with u-health services and technologies. Among them, IEEE 11073 PHD(Personal Health Devices) Work Group is developing standards of personal health device communication for interoperability. There are many studies for introducing SDOs and analyzing the IEEE 11073-20601 standard. However, due to the rare study of PHD standards analysis, there are a lot of difficulties to utilize the standards. In this paper, present status of national and international SDOs including IEEE 11073 standards for PHD will be introduced. Moreover, device specialization standards such as thermometer, weighing scale, glucose meter, blood pressure monitor, electrocardiograph (ECG) etc.. will be analyzed based on the IEEE 11073-20601.

Development of Blood Pressure Simulator for Test of the Arm-type Automatic Blood Pressure Monitor (팔뚝형 자동혈압계 평가용 혈압 시뮬레이터 개발)

  • Kim, S.H.;Yun, S.U.;Cho, M.H.;Lee, S.J.;Lim, M.H.;Seo, S.Y.;Jeon, G.R.
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.239-246
    • /
    • 2015
  • Blood pressure is possible to diagnose a disease associated with blood pressure and judgment the current health of patients. Automatic blood pressure monitor capable of measuring a blood pressure easily in hospital and at home have become spread. In this study, we developed the blood pressure simulator (BPS) that can test the arm-type automatic blood pressure monitor that is commonly used in hospital. BPS is to produce a pressure similar to the pressure wave generated in the human blood using a servo disk motor. Then, using the silicon tube, it implements the situations such as human blood vessels, and to output the generated pressure waveform. Simply the BPS's phantom put on the cuff and it is able to simulate blood pressure. So anyone can quickly test the blood pressure monitor within one minute and it is possible to shorten the test time required for the automatic blood pressure monitor. In Performance test, the trends and the standard deviation of the values measured in the BPS is similar to the value of the measured pressure from people with normal blood pressure. Thus, the development BPS showed a possibility of taking into account the actual blood pressure measurement environment simulator.

Evaluation of Passive Monitor for the Measuring of Personal Exposure to Nitrogen Dioxide in Indoor and Outdoor Air (실내 및 실외 공기중 이산화질소의 개인 노출량 측정을 위한 수동식 시료채취기의 성능평가)

  • 양원호;이기영;백도명
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.625-631
    • /
    • 2000
  • Practical devices for measuring personal exposure to nitrogen dioxide(NO$_2$) have been made for epidemiological studies of the health effects of air pollution Standard methods for NO$_2$ measurement such as the chemiluminescent method and Saltzman method are not suitable for personal exposure because they are heavy, large and complicated to operate. In this study, a passive monitor was tested for the measurements of indoor and outdoor NO$_2$ level. Through a comparative analysis of data sets obtained by on-site chemiluminescence system, we assessed the accuracy and precision of NO$_2$ passive monitors. We also examined the possibility of passive monitor in the study of indoor, outdoor and personal NO$_2$ exposure. The accuracy and precision of NO$_2$ passive monitor were analyzed assuming measurements of on-site chemiluminescence system is reference value and using duplicated measure- ments, respectively. From these analysis the NO$_2$ passive monitor was useful for measuring indoor, outdoor and personal exposure. And NO$_2$ level from on-site chemiluminescence systems could not properly represent the personal NO$_2$ exposure as well as indoor and outdoor level of ones house. Personal exposures were correlated more strongly with indoor NO$_2$ concentrations than with outdoor NO$_2$ concentrations. Since activity pattern of each person is different, it was considered that personal daily behavior and life-style might prevent the air pollutant exposure.

  • PDF

Development and Validation of a Practical Instrument for Injury Prevention: The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT)

  • Sun, Yi;Arning, Martin;Bochmann, Frank;Borger, Jutta;Heitmann, Thomas
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.140-143
    • /
    • 2018
  • Background: The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT) is a practical instrument that is currently used in the German woodworking and metalworking industries to monitor safety conditions at workplaces. The 12-item scoring system has three subscales rating technical, organizational, and personnel-related conditions in a company. Each item has a rating value ranging from 1 to 9, with higher values indicating higher standard of safety conditions. Methods: The reliability of this instrument was evaluated in a cross-sectional survey among 128 companies and its validity among 30,514 companies. The inter-rater reliability of the instrument was examined independently and simultaneously by two well-trained safety engineers. Agreement between the double ratings was quantified by the intraclass correlation coefficient and absolute agreement of the rating values. The content validity of the OSH-MAT was evaluated by quantifying the association between OSH-MAT values and 5-year average injury rates by Poisson regression analysis adjusted for the size of the companies and industrial sectors. The construct validity of OSH-MAT was examined by principle component factor analysis. Results: Our analysis indicated good to very good inter-rater reliability (intraclass correlation coefficient = 0.64-0.74) of OSH-MAT values with an absolute agreement of between 72% and 81%. Factor analysis identified three component subscales that met exactly the structure theory of this instrument. The Poisson regression analysis demonstrated a statistically significant exposure-response relationship between OSH-MAT values and the 5-year average injury rates. Conclusion: These analyses indicate that OSH-MAT is a valid and reliable instrument that can be used effectively to monitor safety conditions at workplaces.

Strategies to Activate Primary Health Care for Low-income Population in Urban Area (도시 저소득층주민을 위한 일차보건의료 활성화 방안)

  • Han Myung Hwa
    • Journal of Korean Public Health Nursing
    • /
    • v.13 no.1
    • /
    • pp.77-87
    • /
    • 1999
  • Poverty directly affects health and well-being, The poor population has a higher rate of chronics illness. higher infant morbidity and motality rates. shorter life expectancy. more complex health problems. and greater physical limitations resulting from chronic disease. In order to activate primary health care for the poverty in urban area the following measures should be taken : 1. Health center must be expended or establish subhealth center. 2. Health center must monitor neighbour's workplace's health management for their working population. 3. Health centers must do active home visiting nursing care for the urban-poor. 4. Health center must carry out flexible problem-centered practice according to the area. 5. For the urban-poor's health care must have organization of the health center & practice according to community's characteristics. 6. Public health care must be closely connected with welfare. 7. For the health care of the urban-poor must demand active community participation. 8. Health center is closely connected with Community hospital. 9. Active management of public health resource system is demanded.

  • PDF