• 제목/요약/키워드: Head position

검색결과 926건 처리시간 0.022초

지지면 간격변화에 따른 푸시업(Push-up) 굽힘동작과 푸시업 플러스(Push-up plus) 동작시 상지 근육의활성도 비교 (Comparative Studies of Muscle Activity on Upper Extremity Between Push-up bend and Push-up plus Movement According to change of supporting base interval)

  • 김은영;박흥기;안병헌
    • 대한물리치료과학회지
    • /
    • 제15권3호
    • /
    • pp.31-41
    • /
    • 2008
  • Purpose : The purpose of this study is to examine the muscle activity of shoulder stabilization according to change of supporting base interval between push-up bend and push-up plus position and is to prevent or treat a shoulder injury by the most effective exercise for rehabilitation. Methods : This study analyzed the muscle activity according to change of supporting base interval between push-up bend and push-up plus movement. The participants without neuromuscular disease were 25 students - 12 males and 13 females - all twenty or over and the surface electrode of EMG attached on pectoralis major, triceps long head, middle trapezius, lower trapezius, serratus anterior and latissimus dorsi. The process has practiced 3 sessions of supporting base interval - narrowing interval, two shoulder interval, broad interval - by push-up bend and push-up plus movement. Result : 1. The muscle activity of pectoralis major was significantly increased according to narrow interval of supporting base on push-up plus movement and was significant difference(p<.05). 2. The muscle activity of biceps was significantly increased according to narrow interval of supporting base on push-up bend movement(p<.05). 3. The muscle activity of middle or lower trapezius was a difference according to change of supporting base on push-up bend and push-up plus movement but was not significant difference. 4. The muscle activity of serratus anterior was significantly increased according to broad interval of supporting base on push-up bend movement(p<.05). 5. The muscle activity of latissimus dorsi was significantly increased according to broad interval of supporting base on push-up bend movement(p<.05). Conclusion : These results lead us to the conclusion that push-up bend exercise have the effect of muscle strength of biceps on narrowing interval, of serratus anterior or latissimus dorsi on broad interval and push-up plus exercise have the effect of muscle strength of pectoralis major on narrowing interval of support base.

  • PDF

초음파 영상과 관련된 견관절 해부학 및 생역학 (Ultrasound Related Anatomy and Biomechanics of Shoulder Joint)

  • 김양수;이재영
    • 대한정형외과 초음파학회지
    • /
    • 제1권2호
    • /
    • pp.112-116
    • /
    • 2008
  • 최근 견관절 질환에 대한 이해가 높아짐에 따라서 견관절에서 초음파의 유용성 또한 급격히 증가하는 추세이다. 초음파 검사는 비 침습적이며 검사 비용이 저렴할 뿐만 아니라 견관절에서는 유일하게 회전근 개의 움직임을 실시간으로 관찰할 수 있다는 큰 장점이 있다. 견관절 초음파 검사는 일반적으로 환자가 앉은 자세에서 실시하며, 검사 순서는 전방에서부터 시작하여 후방 관절 구조물들을 확인하면서 검사를 마친다. 초음파 검사는 견관절 주위의 여러 근육과 인대, 관절와 순, 골 구조 등을 확인할 수 있으며, 특히 회전근 개 질환의 진단에 큰 도움을 준다. 회전근 개는 견갑하근, 극상근, 극하근, 그리고 소 원형근의 네 개의 근육으로 이루어진 하나의 운동 단위이며, 견관절의 능동 운동시 지렛점으로 작용하여 견관절 운동을 원활하게 조종하는 역동적 안정 요소의 기능을 담당한다.

  • PDF

Structures of antimicrobial peptides HP (2-20) and interactions between HP(2-20) and membrain studied by NMR spectroscopy

  • Lee, Kwang-Hwan;Lee, Dong-Gun;Park, Yoonkyung;Hahm, Kyung-Soo;Kim, Yangmee
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 2003년도 정기총회 및 학술발표회
    • /
    • pp.68-68
    • /
    • 2003
  • HP(2-20) (AKKVFKRLEKLEKLFSKIQNDK) derived from the N-terminus of Helicobacter pylori Ribosomal Protein L1 shows potent antimicrobial activity against bacterial, fungi and cancer cells without cytotoxic effect. In order to investigate the relationships between antimicrobial activity and the structures, several analogues have been designed and synthesized. The structures of these peptides in SDS micelles have been investigated using NMR spectroscopy and they revealed that analogue 3 has the longest, well-defined alpha-helix from Val5 to Trp19. NOESY experiments performed on HP and its analogues in nondeuterated SDS micelles show that protons in the indole ring of Trp16 are in close contact with methylene protons of SDS micelles. In order to probe the position of HP and its analogues relative to the SDS micelles, spin-labeled stearate was added. Large effects are observed for the chemical shifts and the intensities of Phe5, Glu9, Phe12, and Trp16 within the helix region by 16-doxylstearate. This result implies that 16-doxylstearate is located in the center of the micelles and the hydrophobic phase of the amphiphilic ${\alpha}$-helix is located in contact with the acyl chains of the micelles. Also, Lys3 and Lys4 at N-terminus and Lys20 at C-terminus may produce an optimal arrangement for electrostatic interactions between the sulfate head groups of the SDS and the positively charged lysyl N$\sub$3/$\^$+/. Interactions between the indole ring of Trp and the membrane, as well as the amphiphilic ${\alpha}$-helical structure of HP induced by Trp at the C-terminus may allow HP to span the lipid bilayer. These structural features are crucial for their potent antibiotic activities.

  • PDF

수태양소장경근(手太陽小腸經筋)에 대한 근육학적(筋肉學的) 고찰(考察) (The study of muscular system about small intestine channel of hand taiyang muscle)

  • 김지남;김영일;홍권의;임윤경;이현
    • 혜화의학회지
    • /
    • 제14권1호
    • /
    • pp.67-81
    • /
    • 2005
  • We have conclusions after the study of muscular system about small intestine channel of hand taiyang muscle. Judging from many studies of interrelation between Meridian muscle and muscle, it is considered that Meridian muscle theory has some similarities with modern anatomical muscular system. It is considered that Small intestine channel of hand taiyang muscle contains Flexor digitorum profundus muscle, Extensor digiti minimi muscle, Abductor digiti minimi muscle, Extensor carpi ulnaris muscle, Flexor carpi ulnaris muscle, Triceps brachii muscle, Infraspinatus muscle, Levator scapulae muscle, Sternocleidomastoid muscle, Masseter muscle, Temporalis muscle. The symptoms of small intestine channel of hand taiyang muscle is similar to referred pain of modern Myofascial Pain Syndrome, and the medical treatment of "I Tong Wi Su(以痛爲輸)" is also similar to that of Myofascial Pain Syndrome. Small intestine channel of hand taiyang muscle is one of the three yang channels of hand muscle, and it has unity in extension of upper limb and trunk in the movement. And it is thought that weakness of small intestine channel of hand taiyang muscle is related with muscular system causing Round Shoulder and Head Forward Position.

  • PDF

자세안정성 원리에 기반한 환자이동기술 개발 및 효과검정 (Development of Patient Transfer Techniques based on Postural-stability Principles for the Care Helpers in Nursing Homes and Evaluation of Effectiveness)

  • 마예원;정덕유
    • 대한간호학회지
    • /
    • 제46권1호
    • /
    • pp.39-49
    • /
    • 2016
  • Purpose: This study was done to develop a postural-stability patient transfer technique for care helpers in nursing homes and to evaluate its effectiveness. Methods: Four types of patient transfer techniques (Lifting towards the head board of the bed, turning to the lateral position, sitting upright on the bed, transferring from wheel chair to bed) were practiced in accordance with the following three methods; Care helpers habitually used transfer methods (Method 1), patient transfer methods according to care helper standard textbooks (Method 2), and a method developed by the author ensuring postural-stability (Method 3). The care helpers' muscle activity and four joint angles were measured. The collected data were analyzed using the program SPSS Statistic 21.0. To differentiate the muscle activity and joint angle, the Friedman test was executed and the post-hoc analysis was conducted using the Wilcoxon Signed Rank test. Results: Muscle activity was significantly lower during Method 3 compared to Methods 1 and 2. In addition, the joint angle was significantly lower for the knee and shoulder joint angle while performing Method 3 compared to Methods 1 and 2. Discussion: Findings indicate that using postural-stability patient transfer techniques can contribute to the prevention of musculoskeletal disease which care helpers suffer from due to physically demanding patient care in nursing homes.

CT사진을 이용한 한국인의 C형 치근관의 분포에 대한 연구 (The distribution of C-shaped canal system in Korean population with CT image)

  • 전록원;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제39권2호
    • /
    • pp.75-79
    • /
    • 2009
  • Purpose: To investigate the incidence and prevalence of C-shaped root canal using computed tomographic images of head and neck in Korean population. Materials and Methods : Regardless of each examination purpose, randomly selected 268 examples which have serial axial computed tomographic images with 8 normal molars in maxilla and mandible were selected and investigated. Defined C-shaped root canal and we could get 82 proper image examples in view of this definition. These were detected and investigated of incidence and prevalence of C-shaped root canal. Results: C-shaped root canals were found in 82 examples among 268 (30.6%) and 147 teeth. They were only found on molar area, and the highest incidence was 37.41% of left mandibular second molars, and the lowest was 2.04% of right maxillary second molars. On prevalence of tooth position, mandibular second molar was the highest, 65% of C-shaped root canal teeth and maxillary second molar was 6% the lowest. Conclusion: 31% of randomly selected CT images no considering check-up reason have C-shaped root canals. The C-shaped root canals of mandibular second molar are found most frequently and they are also detectable on maxilla. On Korean population, C-shaped root canals are one of conditions that have to concern with dental treatment for it appears at a high prevalence relatively. (Korean J Oral Maxillofac Radiol 2009; 39: 75-9)

  • PDF

정위 마스크 시스템을 사용한 방사선수술시 회전중심점의 재현성 (Isocenter Reproducibility with Mask Fixation System in Stereotactic Radiosurgery)

  • 이동준;손문준;이기택;최찬영;황금철;황충진
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.135-138
    • /
    • 2002
  • 치료대상 병소에 분할 방사선수술을 시술할 경우 회전중심(isocenter)은 정확하고 재현성 이 있어야 한다. 본 연구는 노발리스 방사선 수술장비와 정위 마스크 시스템을 사용한 분할방사선 수술에서 회전중심의 재현성을 측정하고 평가 하였다. 마스크는 열가소성 재질의 상용을 사용하였고 회전중심의 재현성을 측정하기 위해 고안된 머리 모양의 아크릴 팬텀에 맞도록 제작하였다. 팬텀의 내부에는 직경 5 mm의 아크릴봉을 수직으로 세우고 그 끝단을 회전중심으로 선택하였으며 예상되는 회전중심점에 pin hole을 낸 monochromic 필름을 설치하여 방사선 조사 후 회전중심의 재현성을 측정할 수 있도록 하였다. 측정 결과 회전중심은 공간오차가 평균 1 mm 이내이고 표준편차 또한 2 mm 이내여서 이미 보고된 타 문헌에서의 측정값과 비교해 볼 때 모든 측정값이 제시된 오차범위 내에 있었다. 결론적으로 분할방사선수술에 사용하는 정위 마스크 시스템은 매우 정확하고 재현성이 우수하였으며, 실제로 방사선 수술대상의 병소의 직경이 10 mm 정도 이상이라면 일반적인 한번의 고선량 방사선 수술에 정위 마스크 시스템의 사용이 가능할 것으로 사료된다.

  • PDF

Validation of a new three-dimensional imaging system using comparative craniofacial anthropometry

  • Naini, Farhad B.;Akram, Sarah;Kepinska, Julia;Garagiola, Umberto;McDonald, Fraser;Wertheim, David
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.23.1-23.8
    • /
    • 2017
  • Background: The aim of this study is to validate a new three-dimensional craniofacial stereophotogrammetry imaging system (3dMDface) through comparison with manual facial surface anthropometry. The null hypothesis was that there is no difference between craniofacial measurements using anthropometry vs. the 3dMDface system. Methods: Facial images using the new 3dMDface system were taken from six randomly selected subjects, sitting in natural head position, on six separate occasions each 1 week apart, repeated twice at each sitting. Exclusion criteria were excess facial hair, facial piercings and undergoing current dentofacial treatment. 3dMDvultus software allowed facial landmarks to be marked and measurements recorded. The same measurements were taken using manual anthropometry, using soluble eyeliner to pinpoint landmarks, and sliding and spreading callipers and measuring tape to measure distances. The setting for the investigation was a dental teaching hospital and regional (secondary and tertiary care) cleft centre. The main outcome measure was comparison of the craniofacial measurements using the two aforementioned techniques. Results: The results showed good agreement between craniofacial measurements using the 3dMDface system compared with manual anthropometry. For all measurements, except chin height and labial fissure width, there was a greater variability with the manual method compared to 3D assessment. Overall, there was a significantly greater variability in manual compared with 3D assessments (p < 0.02). Conclusions: The 3dMDface system is validated for craniofacial measurements.

고용지원센터 상담직원의 조직연계 활동에 영향을 미치는 요인에 관한 연구 (Research on Factors that Influence Interorganizational Relations of Job Center Consultants)

  • 심선경
    • 한국사회복지학
    • /
    • 제61권1호
    • /
    • pp.239-262
    • /
    • 2009
  • 본 연구는 고용관련 조직간 연계 활성화에 필요한 정책적 실천적 지침을 마련하기 위한 것이다. 이를 위해 전국 38개 고용지원센터 상담직원의 조직연계 상황을 실증분석 하였고, 이러한 조직연계에 대한 조직요인, 관리자요인, 개인요인의 영향을 위계적 회귀분석 방법으로 분석하였다. 분석결과를 통해서 고용관련조직과 연계를 강화하고 특히 지역에 따라 차이를 보이는 민간조직들과의 연계 활성화를 위해서는 구조적 혁신과 더불어 담당자들의 전문능력 향상, 자기 업무에 대한 이해를 높이기 위한 조치들이 필요함을 알 수 있다.

  • PDF

Acute effect of self-myofascial release using a foam roller on the plantar fascia on hamstring and lumbar spine superficial back line flexibility

  • Do, Kwangsun;Kim, Jaeeun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권1호
    • /
    • pp.35-40
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the immediate effect of applying self-myofascial release (SMR) to the plantar fascia using a foam roller on hamstring and lumbar spine superficial back line (SBL). Design: Randomized controlled trial. Methods: Thirty-one healthy adults agreed to the method and purpose of the study. Selection and exclusion criteria were screened, and baseline measurements for the Toe Touch test and passive straight leg raise (PSLR) test were obtained. The participants were then randomly assigned to the SMR group or the sham group. After group assignment, the SMR group rolled the surface of the foot from the heel to the metatarsal head using a foam roller for 5 minutes. The sham group received passive mobilization of the ankle joint in the supine position. Afterwards, the Toe Touch test and the passive straight leg-raise test were re-assessed. Results: In the SMR group, the Toe Touch test results showed significant improvement (p<0.05). Left and right PSLR test results showed a significant increase (p<0.05). In the sham group, there was no significant difference between pre and post-test results. The SMR group showed a significant difference in the PSLR test and Toe Touch test compared to the sham group (p<0.05). Conclusions: The results of this study showed that SMR on the plantar fascia was immediately effective for improving the flexibility of the SBL of the lumbar spine and hamstring.